| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All Kind of soil |
| 2 | 1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works up to plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg/cum |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. DSR 2023 Item No. 10.25.2 |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. |
| 9 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. |
| 10 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 11 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate |
| 12 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 13 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 14 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 15 | INTERNAL ELECTRICAL WORKS |
| 16 | Wiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. |
| 17 | Same as item No.(1) but for 5 amp plug point with piano type switch and socket etc. |
| 18 | Same as item No.(1) but for call bell in PVC conduit with 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earthwire drawn in side the condute. |
| 19 | Same as item No.(1) but for light duty exhaust fan. |
| 20 | Same as item No.(1) but for fan and wall fan. |
| 21 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FR PVC insulated 1100 V grade single core multistrands copper conductor cable in 20 mm dia heavyrigid steel conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete and T & P etc. required for proper completion of the work as directed by Engineer in charge. |
| 22 | Supply and laying of 25mm dia heavy guage 16 SWG (1.5 mm thick) PVC conduit complete with bends and other acessories as required and 14 SWG fish steel wire etc. in slab alongwith reinforcement before concreting and plastering but heavy duty (2mm thick) PVC conduit of 25 mm etc, complete in all respect. |
| 23 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 24 | Supply and wiring of submain 2 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 25 | S/fixing of Hexagonal fan box 16 SWG, including phenolic fan sheet. |
| 26 | Supply and Fixing of recess\ Surface \ Pendent mounting round 6 watt LED Down Ligher having Powder coated die cast aluminium housing with hest sink diffuser / Reflector and driver set complete in all respect (CAT-A) |
| 27 | S/F of surface/flush mounting 4 ways TPN distribution board without MCB with additional metal door complete in all respect and as directed at site. CAT-AAA |
| 28 | S/F & 5Amp./6/… 32Amp. MCB 9 K.A. / 10 K.A. CAT-A |
| 29 | Making of joints in GI strip i/c fixing with GI nut & bolt and soldering |
| 30 | S/F of fan step regulator socket type |
| 31 | Supply and fixing of power plug with 15A/240 V flush type switch and 6 pin 20A/10A 250 V flush type universal socket complete with GI box modular tyepe inluding supply of all material, labour T&P etc. required for proper completion of work |
| 32 | Erection and testing of exhaust fan on the existing hole with suitable size |
| 33 | supply and fixing of call bell of approved make |
| 34 | Erection and testing of ceiling fan and regulator etc excluding supply of downrod |
| 35 | Supply and fixng of 1200 mm sweep Ceiling fan ISI marked complete with fan down rod of required size |
| 36 | Supply and fixing of 300 mm sweep 900 RPM exhaust fan heavy duty with the help of MS fasteners, including making connections, making of hole in wall fixing of MS drum & MS louvers of required size |
| 37 | 18% GST Please Enable Macros to View BoQ information |