| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/l (vide classification of soil item-B) |
| 3 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 4 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 5 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 6 | Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 7 | Providing designation 125 mm thick reinforced designation 75 A brick work in C.M (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials , scafolding, raking out joints to 15 mm depth, curing, taxes and royalty ( but excluding the cost of reinforcement) all complete as per building specification and direction of E/l. |
| 8 | Extra brick work for each consecutive floor above first floor including watering and scaffolding all compleat as per direction of E/I |
| 9 | Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 10 | Providing 112mm thick reinforced designation 100A brickwork fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:4) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including the cost of screening carriage of material scaffolfing raking out joint to 15mm depth curing taxes and royalty (but excluding the cost of reinforcement ) all complete as per building specification and direction of E/I. |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 12 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 13 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 14 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 15 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 16 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 17 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 18 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 21 | Foundations, footings, bases of columns, etc. for mass concrete |
| 22 | Suspended floors, roofs, landings, balconies and access platform |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ) |
| 24 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 25 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 26 | Stairs, (excluding landings) |
| 27 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 28 | Weather shade, Chajjas, corbels etc., including edge |
| 29 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 30 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l. |
| 31 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL). |
| 32 | Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. |
| 33 | (a) 10mm TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL). |
| 34 | (b) 12mm TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL). |
| 35 | (c) 16mm TMT Fe 500 ( Only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd.. Bokaro, and Vizag (RINL). |
| 36 | Providing Tor steel reinforcement of 20mm. 25mm. 28 mm, 32mm dia. bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. : 20/25/28/32mm TMT bar Fe 500 (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) |
| 37 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 38 | Supplying , fitting and fixing collapsible gate of apporoved size and make properly fabricated with vertical double channels 20x10x2 mm. at 100mm. Centres and braced with M.S flat diagonals 20 x 3 mm,with top and bottom rails of T. iron 40x40x6 mm with 38 mm dia steel pulleys complete with bolts nuts, locking arrangements stoppers, handles, including applying a primer coat of led paint carriage hosting and taxes all complete as per building specification and direction of E/I. |
| 39 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 40 | Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less then 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement:4 Coarse sand0, jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with wite cement and matching pigments etc, complete Size of tiles 600 x 600 mm. |
| 41 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 42 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 43 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 44 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l. |
| 45 | Extra for plaster work exteriour surface for each consecutive floor above first floor including cost of scaffolding ect all complete as per directiopn of E/I |
| 46 | Making 6x6mm grooves in plaster surface over walls truely horizontal or verical as specified at regular intervals, at all heights including cleaning, finishing scaffoding and curing with all leads and lifts of water all complete as per building specification and direction of E/l. |
| 47 | Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I. |
| 48 | Supplying, fitting and fixing 30mm thick solid core type decorative single leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l. |
| 49 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification) |
| 50 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 51 | Providing 150 mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 150mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l. |
| 52 | Water proofing for old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flextble material brush, roller or spray for water proofing coating per manufacturer Specifications with following steps :-(a)surface preparation .-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing (loose paint / coating, and cement laitance by cleaning with compressed air water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage leakage. On identification of seepage cement grouting to be done with non shrink expanding admixture of Sika India Pvt.L.td.) MYK Schomberg / Dr Fixiti/ Fosroc or equivallent. Providing and reparing of all Corner and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150Mrn X 150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic pc?' lymer of Sika/ Fosroc/MYK Schomberg/Dr 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent.,Befor 'Chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar-including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)lst Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitiot.is material on surface saturated dry roof and inside wall of Parapet.Wall upto 600 mm by brush or roller . After 1st coat of application , 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat shOUld be applied @1.50 kg/Sqmt/coat. For the purpose of measurer-11609-1'e entire treated surface will be measured.\\" (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified read to use, flexible cementtiOus material right angle to the 1st. coat over the glass fibre laid surface: 2nd coat-,should be applied @ 0.7 Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:- Sika Topseal 109hi / Fosroc Brushbond RFXI Dr. Fixit Pidiffin 2K / MYK Aquafin TG . Product Performance - Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder - Density 1.6 kg/I (mixed density) at +27°C Tensile Strength -2 Nimm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Siren th -2 f\l/mm2 concrete failure Accordin' to ISO4624) Slant-Shear Bond Strength -4 Nimm2 (According to FIP 5.15) Elongation at Break -35% Without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) )Protection of treated surface with PCG :- The treated surface should be covered with 25mm/50mm F'CC of M-20 grade (1.1.5:3). with proper slope ( 1:120) towards the rain outlets in alternate panels of 2 mt x 2 mt keeping 6 rnm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 co of 100 ml per bag of of cement to be added in the screed concreie(paid separately.for this items).All corners shall be chamfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed prorSeqswith ridti:corict'ete and the peripheral mouth to be sealed with,moisture insensitive epoxy putty of. Sika India .Pvt.Ltd. / MYK Schornbefg /Dr Fixit/Fosroc .For the purpose of measurement the entire treated surface will be measured.\\" (e)Groove of PCC surface should be filled with POlysulphide Sealant.(Paid Separately). Be d - Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc . Warranty for five years. |
| 53 | Covering of treated surface with PCC :-providing 25 mm thick Cement Concrete M20 (1:1:5:3) maintaining slope in alternate 2 mt x 2mt panels With approved quality of stone chips of 20mm to 6 mm size graded and Cleaned sand of F.M.2.5 to 3 including screening, shuttering, and mixing Cement concrete in mixer with admixture of integral water proofing and Placing in position, striking curing, taxes and royalty all complete as per Building specification and direction of E/I. Panels that has been left should Be casted next day. There should be 6 mm gap between panels .brand- Sika _ plastocrate plus, MYK proof WP 10, Fosroc- Conplast X 421 ic Dr Fixit Pidiproof LM+ |
| 54 | Providing and mixing liquid integral water proffing compound in conctrete of plaster as manufacturer specification and as per direction of engineer in charge. Brand. Sika plastocrate plus, MYK proff WP 10, Fosroc-Conplast x 4211C, Dr.Fixit, Pidiproff LW+ or Equivalent |
| 55 | Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysuiphide Sealant (Porin.g Grade)as per drawings and technical specificationsi6nd direction of E in Charge. (with 18% GST) B rand Sika Polysulphide, Fosrpc-Thioflex 600 Dr. Fixit Pidiseal PS(42P. MY K Seal PS or Euivalent. |
| 56 | HYDT of Driling 200mm x 165mm x 125 meter.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressure and equipments as well as fuel, lubricants and cost of transportation of rig machine annd other vehical up to Site.(Basic rates) |
| 57 | (a) From 0.00 to 50.00 meter |
| 58 | (b) From 51 - 125 meter |
| 59 | Supplying submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 metre submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP |
| 60 | Supplying Fully automatic star delta starter to operate induction motor working on 415v,3phase,50 hz with no volt coil, Overload element, ON-OFF push buttons, with necessary materialsand connected to supply, etc complete starter with original sheet steel encloser |
| 61 | Supply fitting and fixing GI pipe 50 mm Dia (TATA or equivalent make) Medium Quaility as per IS:1239 ( part 01 ) 2004 |
| 62 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 63 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 64 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm |
| 65 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm |
| 66 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 67 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge. |
| 68 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer- n-charge, manufacturer’s specification & drawing. 30 mm thick pre laminated PVC door shutters |
| 69 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:Profile C Fixing with adjustable lugs with split end tail to each jamb |
| 70 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 71 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use ofchequered plate wherever required, all complete. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 72 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 73 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 74 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 75 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 76 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 77 | 75 mm diameter |
| 78 | 110 mm diameter |
| 79 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 80 | Coupler 75 mm |
| 81 | Coupler 110 mm each |
| 82 | Single pushfit Coupler 75 mm |
| 83 | Single pushfit Coupler 110 mm |
| 84 | Single tee with door 75x75x75 mm |
| 85 | Single tee with door 110x110x110 mm |
| 86 | Single tee without door 75x75x75 mm |
| 87 | Single tee without doo 110x110x110 mm |
| 88 | Bend 87.5° 75 mm bend |
| 89 | Bend 87.5° 110 mm bend |
| 90 | Shoe (Plain) 75 mm Shoe each |
| 91 | Shoe (Plain) 110 mm Shoe |
| 92 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 93 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 94 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 95 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 96 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 97 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 98 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 99 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia |
| 100 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 101 | Providing and placing on terrace (at all floo levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and marking necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank. |
| 102 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 103 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 104 | Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings. |
| 105 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 106 | Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole |
| 107 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gm |
| 108 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 109 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length |
| 110 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 gms |
| 111 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc |
| 112 | 15 mm nominal dia Pipes |
| 113 | 20 mm nominal dia Pipes |
| 114 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 115 | 25 mm nominal dia Pipes |
| 116 | 32 mm nominal dia Pipes |
| 117 | 40 mm nominal dia Pipes |
| 118 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 119 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 120 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 121 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 122 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 123 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 124 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 125 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 126 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 127 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia |
| 128 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp |
| 129 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 130 | Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I |
| 131 | Sand-(8 KM) |
| 132 | Aggregate -(22 KM) |
| 133 | Brick-(1+7)km |
| 134 | Fly Ash Brick |
| 135 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \\"p\\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.(A) 580 mm long (c) with 10.0 lit. low level P.V.C. cistern |
| 136 | Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \\"p\\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With \\"P\\" trap (b)10 lit. low level P.V.C. cistern |
| 137 | Supplylng, fitting and fixing the following items complete with all materials as per specification and direction of E/I.C.P.brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. |
| 138 | Supplying, materrials and labour for constructing inspection chamber of designation class 75B brick size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 139 | Point wiring in PVC conduit, with modular type switch:-Wiring for light poinVfan poinUexhaust fan point/call bell point v/ith 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular sw'itch, modular plate suitable GI box etc as required: Group-A |
| 140 | Power Plug Wiring in PVC conduit (2x4 sq. mm): Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 141 | Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 142 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 143 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire |
| 144 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 145 | 4x6 Sqmm + 2x6 sqmm earth wire |
| 146 | Wirilg in existing conduit :-Supplying and drawing following sizes of FR PVC insulated copperconductor single core cable in existing surface / recessed steel / PVC conduit including dismantling as required. 2x4 sq.mm |
| 147 | TV cable in Existing Conduit: Supplying and drawing co-axial cable RG-6 grade copper conductor, PE insulated with PVC sheath in the existing surface/ recessed PVC conduit as required. |
| 148 | Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/ recess including cutting the wall and making good the same as required.: 20 mm |
| 149 | Supply and fixing of following size PVC/G.I. box on surface /recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. : 75 mm x 75mm x 50mm deep/ (4\\" x 4\\") |
| 150 | S/F Piano type switch/ socket :-Suppying and fxing of following piano type switch / socket on the existing switch box / cover including connections etc. as requted. |
| 151 | 5/6 amps, one way switch |
| 152 | 4 3 pin 5/6 amps, socket outlet |
| 153 | TV antenna socket outlet |
| 154 | Electronic step fan regulaior, mini |
| 155 | S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required . (For light plugs to be used in non residential buildings) |
| 156 | S/F power plug point with Modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface of in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required. (For light plugs to be used in non residential buildings) |
| 157 | S/F Ceiling Rose: Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 158 | Batten holder: Supplying and fixing batten/ angle holder including connection etc as required. |
| 159 | S/F Dingdong Call bell :-SupplyIng and fixing Ding-Dong sound call bell single phase. 230 volt,complete as required |
| 160 | ITC fluorescent fitting directly on surface :-Installation testing and commissioning of pre-wired, fluorescent fitting ./ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly / wall. including connection with 1.5 aq.mm FR PVC insulated . copper conductor single core cable and earthing etc. as required. |
| 161 | ITC fluorescent fitting with down rods :- installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, including supplying and fixing ball and socket arrangement 2 nos down rods of 20cm diax1.6mm thick steel conduit/ GI pipe upto 30cm length, painting and wiring the down rod and connection with 1.5 Sq. mm. FR PVC insulated, copper conductor. |
| 162 | ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required. |
| 163 | S/F four pole MCB isolator :-Supplying and fixing following rating four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 164 | 40 amps |
| 165 | 63 amp |
| 166 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required.( but without MCB/RCCB/ Isolator). : 8 way , Double door |
| 167 | Supplying and fixing the follwing way Three Pole pole and Neutral Sheet steel M.C.B distribution board, 415 volts in recess, completed with tinned copper busbar, neutral bus bar, earth bus bar, din bar, hinged front acrylic cover from MCB Knob detachable gland plate, interconnection including earthing etc. as required(without MCB/RCCB/Isolator). |
| 168 | 4 way(4+12) Double door Horizontal type |
| 169 | 6 way(4+18) Double door Horizontal type |
| 170 | S/F 'C' series SP MCB: Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 171 | 6/32 amps, Single pole |
| 172 | 40 amps, DP |
| 173 | 50/63 amps, DP |
| 174 | 50/63 amps, TPN |
| 175 | Earthing with copper earth plate 600mrn x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt)as required. |
| 176 | Supply and laying 6 SWG C.I. wire at 0.50 metre below ground level for couductor earth electrodc, including solding etc. as reqrrired. |
| 177 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from Earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 178 | P/F G.I. lightning condutor finial :-Providing and fixing of lighting conductor finial , made of 25mm dia 300mm long , G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required. |
| 179 | P/F G.I. lightning conductor tape in horizontal run :-Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required.( for Horizontal run ). |
| 180 | P/F G.I. lightning conductor tape in Vertical run :-Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required.( for Vertical run ). |
| 181 | Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 185 sq mm but not exceeding 400 sq. mm in the existing RCC/HUME/STONEWARE/METAL pipe as required. |
| 182 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. : 3½ X 35 sq. mm (32mm) |
| 183 | S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC,50Hz. Luminarie shall be confirm to IS: 10322 partsection-3 and sha-ll be complete with all neccssary accessories as required:90/100W LED Street light |
| 184 | Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of standard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire suitable for 230V 50H2, single phase supply etc. complete as required:1200mm (48\\") Ceiling Fan |
| 185 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required.-20/22W LED Tube light |
| 186 | Supplying of PVC/XLPE insulated PVC sheathedheavy duty, armoured electrical cable with aluminiumconductor forworking voltage up to and including 1100 volts. (Conforms to IS:1554,part-1):35 sq. mm,3.5 core |
| 187 | Supply of Exhaust metal Fan 230mm(9\\"): Supply and fitting of 230mm(9\\"), 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required. |
| 188 | Supply of Exhaust metal Fan(15\\") for Kitchen: Supply and fitting of 380mm(15\\"), 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required |
| 189 | LED Bulb 9W/10W : Supplying and fixing of LED 9W /10W bulb and accessories as required. |
| 190 | 3 core PVC insulated PVC sheathed copper conductor flat submersible cable. Supplying , Flat flexible submersible cable with ,copper conductor , PVC insulated and PVC sheathed as IS:70983 Core 4 Sq mm. Copper wire |
| 191 | Add 18 % GST |
| 192 | Add 1% Labour Cess Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail