| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in levelling course for slope correction of existing RCC roof surfaces including cleaning the roof surfaces amd removing existing APP based membrane removing all foreign materials by wire brushes/brooms/water jet complete all as specified and directed. |
| 3 | M & L for water proofing treatment on existing cleaned RCC roof with following specification and manufacturer Instruction complete all as specified as directed.(a) Applying bitumen primer confirming to IS-3384-1986 over the cleaned plaster surfaces as per IS-3067-1966.(b) Applying a layer of APP based polymeric membrane 3.0mm thick (minimum) weighing 3.0 Kilogram per sqm (reinforced with polyster non oven fabric weighing not less than 160 Gmss per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction.(c) applying one coat of aluminium paint @ 0.10 Litre per Sqm Over APP based Polymeric membrane.(d) Sealing of all angles & abutments upstands with extra care to ensure perfect bondage. Sealing of edges well into grooves & protect the seal with a polysulphide/polyurethane sealant.Note:- water proofing treatment work must be carried out by an authorized applicator or as per direction of GE. |
| 4 | S&F in repair 110mm bore PVC (SWR) soil, waste and vent pipe, in any length, with rubber joints, laid in trenches or in floors complete all as specified and directed. |
| 5 | S&F in repair PVC (SWR) 110mm dia bend and double T equal or unequal at junctions of any radius complete all as specified and directed. |
| 6 | Taking up or down steel tubing 15mm bore and connections, including removing or removal to store complete all as specified and directed. |
| 7 | Taking up or down steel tubing 20mm bore and connections, including removing or removal to store complete all as specified and directed. |
| 8 | S&F 15mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 9 | S&F 20mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 10 | Taking down cement plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key complete all as specified and as directed |
| 11 | M&L for rendering 15mm thick plaster first layer in 10mm thick in CM (1:6) and subsequent 5mm thick layer in CM (1:4) on brick/block wall or concrete surfaces finished even & fair complete all as specified and as directed. |
| 12 | M&L for rendering 15mm thick plaster in CM (1:6) on brick/block or concrete surfaces finished even & smooth complete all as specified and as directed. |
| 13 | M&L for rendering 10mm thick plaster in CM (1:3) on brick/block or concrete surfaces finished even and smooth complete all as specified and as directed. |
| 14 | Taking out existing unserviceable plaster, loose unsound weaken cement concrete of any description and in any position from existing surface of RCC roof slab/ RCC facia/ beams/ columns/ RCC chajja, average depth 20 mm (approximate 10 mtrs height from natural GL) with power driven pneumatic chiesel and removal of debries upto a distence 500 mtrs out side MD land including saw cutting of all edges, making square shoulders of cavaties and roughening of smooth surface, scraping out and removing corrosion and all loose scales, rust etc. from the visible reinforcement and cleaning the steel reinforecement properly providing NIT zink primer, Zink primer on visible reinforcement surface to form a contineous film and preparing the surface to recive concrete of epoxy grouting mortar etc. including providing necessary scaffolding complete all as specified and as directed. |
| 15 | M&L for applying bonding coat of modified styrene butadene emulsion in proportion 1 part (bonding agent) : 1 part (water) : 3 part (OP cement) by volume with the brushes etc. to bind new cement plaster/ polymer modified plaster/ concrete/ screed concrete with oldsurface including removal of loose/ distengrated old concrete/ plaster including preparation of surface etc. complete all as specified and as directed. |
| 16 | S&F wire netting 1.23mm dia size of mesh 20mm of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples. (approximate 10 mtrs height from natural GL) complete all as specified and directed. |
| 17 | M&L for rendering 25mm thick plaster in CM (1:4) on brick/block or concrete surfaces in two layers 15mm thick and 10mm thick (approximate 10 mtrs height from natural GL) finished even and smooth complete all as specified and as directed. |
| 18 | Material and Labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltr/10sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10sqm over new surfaces |
| 19 | M&L for applying two coats of oil bound distemper over a coat of primer on newly plastered surface of wall including preparation of surface, complete all as specified and as directed |
| 20 | M&L for applying two coats of oil bound distemper over a coat of primer on newly plastered surface of ceiling including preparation of surface, complete all as specified and as directed |
| 21 | M&L for complete removal of existing treatment of wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed. |
| 22 | Dismantling water tanks and exc. 250 but n. exc. 500 litre capacity complete all as specified and as directed. |
| 23 | Supply, hoisting and fixing rotational moulded water storage tank 500 ltr capacity triple layer (cylindrical vertical with closed top) white colour hoisted and fixed in position complete all as specified and as directed. |
| 24 | S&F 15mm PTMT ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 25 | Dismantling water tanks, cleaning and removing all scale and dirt, etc from tanks and room mouths of circulating pipe and refixing to same place complete all as specified and as directed. |
| 26 | S&F in repairs 20mm bore PTMT ball valve with polythene float and fly nut complete all as specified and as directed. |
| 27 | M&L for PCC 1:3:6 type C2 (40mm graded stone aggregate) in flooring/hard standing/Path/Plinth Protection and similar works finished even and fair complete all as specified and as directed. |
| 28 | S&F in repair cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete with fittings Please Enable Macros to View BoQ information |