| 1 | Repair, maint and making the continuity of supply after rectifying the minor defects of the electrical fitting/ accessories such as switches, sockets, distribution boards, MCB (light/power), lamp holders , bel, push button, ceiling rose lamp, plug top and other similar electrical items/fittings etc. including providing of small pieces of electrical wire copper conductor of size 1.5 sqmm to 10 sqmm single core and length not exceding 0.50 mtrs where required and all types of screws, nuts, bolts & washers if required at site complete all as specified and directed. Note :- (i) Any accessories found unserviceable that shall be supply and paid under respective items of this BOQ (ii) Contractor/ superviser of contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectify on next day morning (iii) Complaint slip book, registers as per sample will be provided by the contractor. (iv) Wire/ cable more than 0.5 Mtr if required will be paid under respective of BOQ. |
| 2 | Supply only cable PVC insulated unsheathed with flexible multistranded copper conductor single core of size 0.75 Sqmm. |
| 3 | All as per item No 2 above but size 1.5 Sqmm. |
| 4 | All as per item No 2 above but size 2.5 Sqmm. |
| 5 | All as per item No 2 above but size 4 Sqmm. |
| 6 | All as per item No 2 above but size 6 Sqmm. |
| 7 | All as per item No 2 above but size 10 Sqmm. |
| 8 | Supply only cord flexible PVC insulated and over all sheathed, 3 core, flexible copper conductor of size 0.75 sqmm, cut to size all as required at site. |
| 9 | All as per item No-8 above but size 1.5 sqmm. |
| 10 | Supply only for switch piano flush button single pole one way 5 amps 240 volts. |
| 11 | Supply only for switch piano flush button single pole one way 15 amps 230 Volts. |
| 12 | Supply only for switch piano flush button single pole two way 5 amps 240 volts. |
| 13 | Supply only for bell push flush button single pole one way 5 amps 240 volts. |
| 14 | Supply only for socket 5 amps 5 pin flush type, 230 volts. |
| 15 | Supply only for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts. |
| 16 | Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. all as specified and directed. |
| 17 | Supply only stepped type electronic fan regulator for BLDC fan flush on the existing phenolic laminated sheet etc. all as specified and directed |
| 18 | Supply only for ceiling rose surface bakelite 3 terminals. |
| 19 | Supply only Lamp holder insulated body with back plate for dome batten fittings. |
| 20 | Supply only for bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified and directed. |
| 21 | Supply only PVC round junction box cover of size up to 6\\" dia, 0.3cm thick incl fixing with suitable size of machine screw complete all as specified and directed. |
| 22 | Supply only LED lamp 12 Watt suitable for fixing in lamp holder all as specified and directed. |
| 23 | Supply only LED lamp 15 Watt suitable for fixing in lamp holder all as specified and directed. |
| 24 | Supply only LED lamp 9/12 Watt suitable for fixing in fency light fitting all as specified and directed. |
| 25 | Supply only for switch modular type single pole one way 1 module 6 amps 240 volts. |
| 26 | Supply only for Switch modular type one way 1 module 16 amps 230 Volts. |
| 27 | Supply only for Switch modular type two way 1 module 10 amps 230 Volts. |
| 28 | Supply only for bell push modular type 1 module one way 6 amps 240 volts. |
| 29 | Supply only for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts. |
| 30 | Supply only for socket modular type , 2/3 pin, 6/16 amps combined 2 module, 230 volts. |
| 31 | S&F in replacement fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 1/2 module (as per site reqmt) including necessary connections as per sample all as specified and directed. |
| 32 | S&F in replacement modular white cover plate with frame 3 module all as specified and directed. |
| 33 | S&F in replacement modular white cover plate with frame 4 module all as specified and directed. |
| 34 | S&F in replacement modular white cover plate with frame 6 module all as specified and directed. |
| 35 | S&F in replacement modular white cover plate with frame 8 module all as specified and directed. |
| 36 | S&F in replacement modular white cover plate with frame 12 module all as specified and directed. |
| 37 | S&F for GI/MS sunken box not less than 1.2 mm thickness of size upto 3 Module incl cutting chases on wall , flush mounting sunken box and making good the disturbed surface complete all as specified and directed. |
| 38 | All as per srl item No 37 here in before but for size 4 module. |
| 39 | All as per srl item No 37 here in before but for size 6 module. |
| 40 | All as per srl item No 37 here in before but for size 8 module. |
| 41 | All as per srl item No 37 here in before but for size 12 module. |
| 42 | Supply and fixing plastic laminated top sheet cover 3 mm thick of size 7\\"x4\\" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box. |
| 43 | All as per item No 42 above but of size 8\\"x5\\". |
| 44 | All as per item No 42 above but of size 11\\"x9\\". |
| 45 | All as per item No 42 above but of size 4\\"x4\\". |
| 46 | S&F in repair sunken box size 8\\"x5\\" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed. |
| 47 | S&F in repair sunken box size 7\\"x4\\" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed. |
| 48 | S&F in repair sunken box size 4\\"x4\\" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed. |
| 49 | Supply only plug top 3 pin 16 amps AC 240 Volts all as specified and directed. |
| 50 | Supply only plug top 3 pin 6 amps AC 240 Volts all as specified and directed. |
| 51 | M&L for opening the cover of meter box any type and cleaning the electric meter single/three phase and making sealing (up to 4 Nos seals as per site requirement) of meters with high grade tranparent polycarbonate material and galvanized steel wire of suitable length complete including marking qtr No with paint on electric meter and closing the meter box all as specified and directed. |
| 52 | M&L for replacement the cover of meter box any type all as specified and directed. |
| 53 | S&F in replacement of AC single phase electric energy meter Accuracy class 1.0, 240 Volts, 50 Hz, with backlit LCD display, of rating 10-40 Amps (measures & displays KWH, V, I, KW ,PF, last month history of KWH & MD in KW) with special features like TOD, Temper logging, Optical communication port & display in absence of power and incl making sealing of meters with high grade tranparent polycarbonate material all as spfd. |
| 54 | Disconneting & taking down geyser any type/capacity complete. Refixing to the same location with all connected accessories after cleaning replacing anchor bolts complete all as required and directed. |
| 55 | S&F of thermostat as per sample for geyser of capacity upto 50Ltrs with temperature range adjustable from 25 to 75 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply complete all as specified and directed. |
| 56 | S&F of glass lined incoloy heating element ISI Marked of rating 2.0 KW of size and type as per site requirement incl rubber washers suitable for water heater storage of size 25/50Ltrs complete all as specified . |
| 57 | Disconneting & taking down ceiling fan up to 1400 mm sweep / exhaust fan up to 450mm sweep and handed over to user for repair from MES workshop all as spfd and directed. |
| 58 | Refixing of ceiling fan up to 1400 mm sweep / exhaust fan up to 450mm sweep and making electric connections all as spfd and directed. |
| 59 | Disconneting & taking down ceiling fan up to 1400 mm sweep and repair, replacement of driver card as per sample and refixing to the same/other location after cleaning all as spfd and directed. |
| 60 | S&F fan capacitor AC 440 volts 2.5 mfd 50/60Hz incl PVC clamp complete and all as specified. |
| 61 | All as per srl item No 60 here-in-before but 3.15 mfd. |
| 62 | All as per srl item No 60 here-in-before but 4.0 mfd. |
| 63 | Disconnecting electrically, dismentling and taking out old light fittings any type/size and keeping in safe custody for reusing serviceable light fittings complete all as specified and directed. |
| 64 | Fixing only light fittings (retrieved under ser item number 64) and making electric connections complete all as specified and directed. |
| 65 | Supply and fixing in replacement 20W surface / wall mounted box type batten LED fitting having polycarbonate housing and diffuser and integrated electronic driver complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 66 | All as per ser item No 65 here in before but for 10 W LED batten fitting 2 feet long. |
| 67 | Supply and fixing in replacement surface mounted, bulk head LED luminaire 10 W with and integrated electronic driver, IP 65 protection complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. |
| 68 | Supply and fixing in replacement LED 2'x2' slim panel 36 W, 220 V AC recessed/surface type having white powder coated CRCA housing and high quality diffuser for glare free light with driver and mounting clips suitable for POP/gypsum ceiling and connecting up suitable size flexible copper conductor cable incl making good the disturbed POP surface complete all as specified. |
| 69 | Supply and fixing modular MCB 20 Amps with modular socket fitted with 3 module frames (inner & outer), complete all as specified and directed. |
| 70 | Supply and fixing in replacement round/square shaped LED 12Watt recessed type panel, 220 volts AC with Polycarbobnate housing and high efficiency diffuse for glare free light complete with drivers, mounting clips suitable for roof ceiling including connecting up suitabel size flexible copper conductor cable complete all as specified and directed. |
| 71 | All as per Ser item No 70 here in before but for 18Watt. |
| 72 | Supply and fixing in replacement LED 18 watt surface mounted round/square shaped rimless downlight panel having polycarbonate housing, high quality PC diffuser for glare free light with inbuilt driver and mounting arrangement suitable for surface/roof mounting including connecting up suitable size flexible copper conductor cable complte all as specified and directed. |
| 73 | Supply and fixing in replacement fancy type wall/surface mounted decorative light fitting with brushed nickle finish fixture and opal glass decorative diffuser, B-22 type lamp holder and wall mounting arrangment including 9W LED lamp and connecting up with suitable size flexible copper conductor complete all as specified and directed. |
| 74 | Supply and fixing in replacement decorative wall mounting LED bed side light 2 watt 3000K fitting having flexible neck and mounting clips incl connecting up with suitable size flexible copper conductor cable complete all as specified and directed. |
| 75 | S & F in replacement of LED post top lantern 35/40 Watt warm white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection including fixing of GI pipe of suitable dia dia, 300 mm long light grade, partly embedded on column of gate with fixing arrangement complete and making electrical connection complete all as specified and directed. |
| 76 | S&F in replacement LED wall security lights of 35 Watt having pressure die cast aluminium housing, IP65 protection, IK07 rating, inbuilt electronic driver incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable complete all as specified and directed. |
| 77 | S&F of chromium plated flexible copper connection with two brass adopter as per existing sample suitable for carrying hot/ cold water, fixed one end at geyser inlet/outlet and other to inlet/outlet water supply point not less than 45 cm long complete all as specified and directed. |
| 78 | Supply only plug top and socket of metal plug, 20 Amps, 240 Volts complete all as specified and directed. |
| 79 | S & F in replacement distribution board iron clad, double door with IP-43 1K-09 protection 4 way with MCCB as incommer and MCB as outgoing (MCB Shall be measured and paid under respective items), complete with appropriate size copper bus bar and neutral link, with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed. |
| 80 | All as per Srl item No 79 here in above but for 8 way DB with MCCB 100 Amps 16KA. |
| 81 | S&F for SPN MCB DB 8 way sheet metal enclosures double door 230V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar, neautral bar, earth bar and cable ties for cable management including polyuthrene gasket complete fixed flush in wall including cutting chases on wall for taking out old DB and fixing of new DB and making good disturbed surface of wall with cement mortar and finishes to match exisiting surface complete all as specified and directed. |
| 82 | All as per Ser item No 81 here in above but for size 4 way DB. |
| 83 | All as per Ser item No 81 here in above but for size 12 way DB. |
| 84 | Supply and fixing in replacement MCB SP 240V, 50Hz of rating 6 to 32 Amp, 'B' curve using suitable size copper thimbles complete all as specified and directed. |
| 85 | All as per Ser item No 84 here in before but for size 32 Amps MCB SPN. |
| 86 | All as per Ser item No 84 here in before but for size 40-63 Amps MCB SPN. |
| 87 | Supply and fixing in replacement of MCCB 100 Amps 3Pole 415Volts, 16kA breaking cap with fixed thermal and fixed magnetic setting and fixing in exisiting DB and making connection with cable by means of suitable size of thimbles complete all as specified and directed. |
| 88 | All as per item No 87 above but of size 63 Amps. |
| 89 | All as per item No 87 above but of size 125 Amps. |
| 90 | S & F for sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 Sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including suitable size concealed rigid medium grade PVC conduit not less than 20mm dia 1.5mm thick with all accessories incl cutting chases on wall and making good to the disturbed surface of wall/floor with cement mortar 1:4 and finishes to match existing surface complete all as specified and directed. |
| 91 | Deduct : Total amount of SCH 'A' SEC-II (SCH OF CREDIT)Rs. 45000.00 to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum. Please Enable Macros to View BoQ information |