| 1 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion from hardcore, concrete work or masonry work, complete all as specified and as directed. |
| 2 | Excavation in Post holes each, not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 metres and making good surface in soft/disintegrated rock complete all as specified and as directed. |
| 3 | Material and Labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description and in any position not otherwise specifically provided for (framed/ unframed work) complete all as specified and directed. |
| 5 | Supply and Fixing of steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS- 1161:1979 grade St-240 including painting one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor's workshop before fabrication complete all as specified and directed. |
| 6 | Material and Labour for dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings or any other description as specified and directed. |
| 7 | Material And Labour for pre painted galvalume aluminium zinc Gl based corrugated steel sheet 0.50 mm thick of any colour and of any pattern having tensile strength of 550 Mpa as in roof covering fixed with J or L hooks or self-tapping screws with washers complete all as specified and directed. |
| 8 | Supply and Fixing of 1.25 mm thick Mild steel sheet eaves gutters of dia 150 mm, galvanised class 3, half round with rounded edges complete all as specified. |
| 9 | Supply and Fixing of 1.25 mm thick Mild steel sheet and of dia 150 mm, drop ends for spigot or socket ends or nozzles complete all as specified and directed. |
| 10 | Supply and Fixing of 1.25 mm thick Mild steel sheet and of dia 150 mm, stop ends for spigot or socket ends or nozzles complete all as specified and directed. |
| 11 | Supply and Fixing of 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 12 | Supply and Fixing of 110 mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 13 | Excavation in trenches not exceeding 1.5 metres wide & not exceeding 1.5 metres in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5 metres in depth and getting out in in Soft/Disintegrated rock complete all as specified and directed. |
| 14 | Material and Labour for PCC 1:4:8 type D2 (40 mm graded aggregate) in foundation filling and mass concrete etc; complete all as specified and directed. |
| 15 | Material and Labour for Machine cut laterite stone masonry exceeding 10 cm in width square rubble, regular 5 coursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. |
| 16 | Material and Labour for rendering 15 mm thick in cement mortar 1:4 over stone masonry, concrete surfaces, finished even and smooth without using extra cement, all as specified and as directed. |
| 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each layer in soft/disintegrated rock all as specified and directed. |
| 18 | Removing excavated soil not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metres above the starting point all as specified and directed. |
| 19 | Demolition of cement concrete in ground floor not exceeding 15 cm thickness below or above ground level including floor finishes and removing debris from the site, complete all as specified and directed. |
| 20 | Material and Labour for 75mm thick PCC 1:4:8 type D-2, 40mm graded stone aggregate as in sub floor, sub bases, floor and paving etc; complete all as specified and directed. |
| 21 | Material and Labour for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete etc of approved make all as specified and directed. |
| 22 | Material and Labour for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves thickness of joints except at sharp curve shall not to more than 5 mm, including making drainage opening wherever required, complete all as specified and directed. |
| 23 | Material and Labour for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified and directed. |
| 24 | Material and Labour for preparing new plastered surfaces of walls and for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance, dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/prepared surfaces. complete all as specified and directed.Note- Primer and emulsion to be carried out through air less spray machine |
| 25 | Material and Labour for preparation of new steel surfaces and applying twocoats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 26 | Taking down existing unserviceable copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and removable of unserviceable material out of site and making good disturbed surfaces of walls, floors, etc. so as to match with the existing finishes, complete all as specified and directed. |
| 27 | Taking down the existing unserviceable main switch/ cut outs/ DBs any type/capacity description as per existing at site including making good disturbed surfaces of wall to match with existing surfaces, complete all as specified and directed. |
| 28 | Material and Labour for point wiring with PVC insulated unsheathed FRLS stranded copper conductor cable of size 1.5 Sq mm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm stranded for earth continuity wire, to be drawn in and including, PVC casing caping/PVC medium grade with suitable size surface in walls/roof/shed with PVC box suitable for modular switches/sockets and Modular plate and brass screws with cup washers for One light point controlled by one way switch complete all as directed and specified.Note: (1) Rate is inclusive of Modular plate & Modular box |
| 29 | All as per Serial Item No 28 above but for One 3 pin 5-amp socket out point on the same board with other switches complete. |
| 30 | All as per Serial Item No 28 above but for One 3 pin 5 amps socket out let point on independent board complete. |
| 31 | All as per Serial Item No 28 above but for One socket outlet 15/16 Amps on independent board with 2.5 Sqmm cable and 2.5 Sqmm earth wire complete.Note: Rate is inclusive of Cutting/chases of wall/floor/ceiling. |
| 32 | Supply and Fixing in replacement of Modular switch 1-way 10Amps,1 module complete all as specified and as directed. |
| 33 | Supply and Fixing in in replacement of Modular switch 1-way 16 Amps,1 module complete all as specified and as directed. |
| 34 | Supply and Fixing in in replacement of Socket, 5/6 Amps - 2/3 pin combined 2 module complete all as specified and as directed. |
| 35 | Supply and Fixing in in replacement of Socket 6/16 Amps - 2/3 pin combined 2 module complete all as specified and as directed. |
| 36 | Supply and Fixing in Surface Modular Box of 6 way along with 6 way Modular plate and 2 Nos of 16 Amps Switches and 6/16Amps multipurpose Sockets with connected internal wiring complete all as specified and directed. Note: Modular Plate, Switches & Sockets are inclusive of the rate quoted complete. |
| 37 | Supply and fixing in replacement of Ceiling rose, surface bakelite 65x50 mm three terminal 3 phase/PVC/ polycarbonate, isolated body complete all as specified and as directed. |
| 38 | Supply and fixing in replacement of LED lights fitting 1x18Watts/20 Watts, 220 Volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 39 | Supply and fixing in replacement of LED Security light fitting 25/35-Watt 230 Volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 40 | Supply and fixing of GI pipe bracket 32 mm dia 0.60 metre length fixed on wall/shed with suitable flat iron clamps and nut bolts complete all as specified & directed. |
| 41 | Supply and fixing of MCB DB made of sheet steel, powder painted with NUTRAL bus bar with suitable rating, neutral link, earth bar and Din rail ,240 Volts SPN with 8 way Double door, IP-43-IK09 protection grade. complete all as specified and directed.Note: Plywood to be provide for proper fixing of SPN DB at parking shed. |
| 42 | Supply and fixing in replacement of of MCB SPN 40 Amps 240 Volts, 'C' series, breaking capacity 10 KA complete all as specified and directed. |
| 43 | Supply and fixing in replacement of MCB SP 10 Amps, 240 Volts, 'C' series, breaking capacity 10 KA complete all as specified and directed. |
| 44 | Supply and fixing in replacement of MCB SP 20 Amps, 240 Volts, 'C' series, breaking capacity 10 KA complete all as specified and directed. |
| 45 | Supply and fixing of astronomical timer swich of supply voltage 110-240 Volt, AC frequency 50/60Hz, trigger modes sunrise, sunset, IP 20 For terminal, IP 40 for encloser complete all as specified and directed. |
| 46 | Supply and Fixing in replacement of Sub main wiring power/circuit using PVC insulated unsheathed FRLS, stranded copper conductor cable 2 Single core of size 1.5 Sqmm, earth continuity conductor of size 1.5 Sqmm to be drawn through in and including PVC conduit in walls/roof/floors complete all as specified and directed.Notes:-3 wires of 1.5 sqmm and PVC conduit shall be measured as one unit. |
| 47 | Supply and fixing of flexible PVC conduit of 25 mm dia size complete all as specified and as directed. |
| 48 | Supply and installation of fast earth electrode 3.0 metre length size model F84, having two Mild Steel pipe one inside the other with proper not deep galvanised outer dia 88 mm and inner dia 48 mm and the cavity between the rod pipes is filled with ground resistance improment powder, sealed with both end the outer pipe of electrode should be zinc coated, the electrode should buried directly in the ground by making boring of diameter 10'' with boring machine highly conductive non-magnetic and non-corrosives is to be connected with including GI wire 4mm dia facilitate further connection to earth dolly and provision of earthing chamber in bricks wall size 45x45x15 cm an having PCC cover of required size as per IS 3034 (1981) complete all as specified and as directed.Note:-GI wire to be measured and paid separately. |
| 49 | Supply and Fixing of Earth continuity conductor or main earthing lead of size 4 mm dia galvanised iron wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and as directed. |
| 50 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sqmm 2 core complete all as specified and directed.Note - Rate is inclusive of cable gland & cable lugs. |
| 51 | Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mm conforming IS 16205 (Part 24) for protection of electric cable complete all as specified and directed. |
| 52 | Material and Labour for road cutting and repairing the same with road patch material width up to 75cm for laying 50mm dia GI pipe complete all as specified and directed. |
| 53 | Material and Labour for steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles of size 50 mm dia completed all as specified and directed. |
| 54 | Credit Amount shall be deducted to arrive the Contract Sum. Please Enable Macros to View BoQ information |