| 1 | Supply and laying of Cable (2/3/4 Core FRLS Cable) Fire Resistant Cable including dismentling the existing foulty cable of KEI/Apar Industries/ Polycab/ Havells/ Finolex only | Supply and laying of Cable (2/3/4 Core FRLS Cable) Fire Resistant Cable including dismentling the existing foulty cable of KEI/Apar Industries/ Polycab/ Havells/ Finolex only |
| 2 | Supply and Installation of Smoke Detectors of ULFM Approved and NFPA Certified brands (any one of the Edward, Honeywell, Notifire, Bosch, Johnson Control make only) compatible with EST3 | Supply and Installation of Smoke Detectors of ULFM Approved and NFPA Certified brands (any one of the Edward, Honeywell, Notifire, Bosch, Johnson Control make only) compatible with EST3 |
| 3 | Supply and Installation of Manual Call Point ULFM Approved and NFPA Certified brands (any one of the Edward, Honeywell, Notifire, Bosch, Johnson Control make only) compatible with EST3 | Supply and Installation of Manual Call Point ULFM Approved and NFPA Certified brands (any one of the Edward, Honeywell, Notifire, Bosch, Johnson Control make only) compatible with EST3 |
| 4 | Supply and Installation of Hooter/Siren of ULFM Approved and NFPA Certified brands (any one of the Edward, Honeywell, Notifire, Bosch, Johnson Control make only) compatible for EST 3 as approved by Engineer-in- charge | Supply and Installation of Hooter/Siren of ULFM Approved and NFPA Certified brands (any one of the Edward, Honeywell, Notifire, Bosch, Johnson Control make only) compatible for EST 3 as approved by Engineer-in- charge |
| 5 | Supply and installation of Power Supply Unit, (any one of the Edward, Honeywell, Notifire, Bosch, Johnson Control make only) compatible for EST 3 as approved by Engineer-in- charge | Supply and installation of Power Supply Unit, (any one of the Edward, Honeywell, Notifire, Bosch, Johnson Control make only) compatible for EST 3 as approved by Engineer-in- charge |
| 6 | Supply and Installation of module of ULFM Approved and NFPA Certified brands compatible with Notifier, Morley and EST3 | Supply and Installation of module of ULFM Approved and NFPA Certified brands compatible with Notifier, Morley and EST3 |
| 7 | Supply and Installation of Dual loop card of ULFM Approved and NFPA Certified brands compatible with Notifier, Morley and EST3 | Supply and Installation of Dual loop card of ULFM Approved and NFPA Certified brands compatible with Notifier, Morley and EST3 |
| 8 | Supply and Installation of daughter card of ULFM Approved and NFPA Certified brands compatible with Notifier, Morley and EST3 | Supply and Installation of daughter card of ULFM Approved and NFPA Certified brands compatible with Notifier, Morley and EST3 |
| 9 | Dismentling of existing foulty or unused fire Cable (2/3/4 Core FRLS Cable) | Dismentling of existing foulty or unused fire Cable (2/3/4 Core FRLS Cable) |
| 10 | Comprehensive maintanence on monthly basis of fire detection/alarm systems including engineer visit, inspection, complete cleaning of smoke detector, identify the defect or fault, fault rectification, programming of existing conrol panel (if required) of fire alarm system complete. A fitness certicate must be issued every month after comprehensive maintanence (Required replacement items will be provided by the department) (W.e.f. July 2026 to March 2027) | Comprehensive maintanence on monthly basis of fire detection/alarm systems including engineer visit, inspection, complete cleaning of smoke detector, identify the defect or fault, fault rectification, programming of existing conrol panel (if required) of fire alarm system complete. A fitness certicate must be issued every month after comprehensive maintanence (Required replacement items will be provided by the department) (W.e.f. July 2026 to March 2027) |
| 11 | Repair and Servicing of 62.5 KVA DG set including filters (Fuil and Air), gasket, M-Oil, and coolent etc complete Make kirlosker, speed 1500rpm | Repair and Servicing of 62.5 KVA DG set including filters (Fuil and Air), gasket, M-Oil, and coolent etc complete Make kirlosker, speed 1500rpm |
| 12 | Rectification, servicing, cleaning, lubrication and functional testing of fire hydrant butterfly valves and landing valves, Y-type strainer including inspection, cleaning and leak testing after reinstallation. | Rectification, servicing, cleaning, lubrication and functional testing of fire hydrant butterfly valves and landing valves, Y-type strainer including inspection, cleaning and leak testing after reinstallation. |
| 13 | Providing and Replacement of MS 'C' Class pipe of dia 100 mm including cutting, hoisting, fixing in position and welding all complete. | Providing and Replacement of MS 'C' Class pipe of dia 100 mm including cutting, hoisting, fixing in position and welding all complete. |
| 14 | Providing and Replacement of MS 'C' Class pipe of dia 150 mm including cutting, hoisting, fixing in position and welding all complete. | Providing and Replacement of MS 'C' Class pipe of dia 150 mm including cutting, hoisting, fixing in position and welding all complete. |
| 15 | Providing and Replacement of MS 'C' Class pipe of dia 200 mm including cutting, hoisting, fixing in position and welding all complete. | Providing and Replacement of MS 'C' Class pipe of dia 200 mm including cutting, hoisting, fixing in position and welding all complete. |
| 16 | Supply, Installation & Testing of Wall mounted Hose reel Drum With Hose reel Pipe including making connection with existing pipe. | Supply, Installation & Testing of Wall mounted Hose reel Drum With Hose reel Pipe including making connection with existing pipe. |
| 17 | Supplying and replacing existing foulty Hydrant Valve | Supplying and replacing existing foulty Hydrant Valve |
| 18 | Supply, Installation of RRL Hose Pipe X 15mtr | Supply, Installation of RRL Hose Pipe X 15mtr |
| 19 | Supply and Installation of FRP Double Door Hose Box of Size 30\\"x24\\"x10\\" | Supply and Installation of FRP Double Door Hose Box of Size 30\\"x24\\"x10\\" |
| 20 | Supply, Installation & Testing of 80MM Butterfly Valve | Supply, Installation & Testing of 80MM Butterfly Valve |
| 21 | Supply, Installation & Testing of 100MM Butterfly Valve | Supply, Installation & Testing of 100MM Butterfly Valve |
| 22 | Supply, Installation & Testing of 150MM Butterfly Valve | Supply, Installation & Testing of 150MM Butterfly Valve |
| 23 | Comprehensive maintanence on monthly basis of fire fighting / fire suppression systems including engineer visit, inspection, identify the defect or fault, fault rectification, which also include serviving greasing and maintanece of existing componenet i.e pumps, Generator set, valves,electric panel, hose reel drum, pipes etc fire fighting system, sprinklers etc complete. A fitness certicate must be issued every month after comprehensive maintanence (Required replacement items will be provided by the department) (W.e.f. July 2026 ot March 2027) | Comprehensive maintanence on monthly basis of fire fighting / fire suppression systems including engineer visit, inspection, identify the defect or fault, fault rectification, which also include serviving greasing and maintanece of existing componenet i.e pumps, Generator set, valves,electric panel, hose reel drum, pipes etc fire fighting system, sprinklers etc complete. A fitness certicate must be issued every month after comprehensive maintanence (Required replacement items will be provided by the department) (W.e.f. July 2026 ot March 2027) |