| 1 | Total Amount |
| 2 | Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 of approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge.for leaf width upto 1100mm |
| 3 | Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in- Charge fitted and fixed complete including all incidental charges. |
| 4 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer |
| 5 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats)ii) Luxury Quality |
| 6 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.9th Floor |
| 7 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. I) For structural members of specified sections weighing less than 22.5 Kg./mGround Floor and 1st Floor |
| 8 | 2nd Floor |
| 9 | 3rd Floor |
| 10 | 4th Floor |
| 11 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 12 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss)(iv) Two coats (with any shade except white) |
| 13 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In ground floor including roof.(a) upto 150 mm. thick |
| 14 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 15 | Cement concrete with graded jhama khoa (30 mm size) excluding shutteringIn ground floor and foundation.(a) 1:3:6 proportion |
| 16 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 17 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL |
| 18 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 19 | Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(iii) 25 mm dia.(c) 750 mm long |
| 20 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth |
| 21 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) inground floor.Ground Floor |
| 22 | 1st Floor |
| 23 | 2nd Floor |
| 24 | 3rd Floor |
| 25 | 4th Floor |
| 26 | 5th Floor |
| 27 | 6th Floor |
| 28 | 7th Floor |
| 29 | 8th Floor |
| 30 | 9th Floor |
| 31 | 10th Floor |
| 32 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar(b) 20 mm thick plasterGround Floor |
| 33 | 1st Floor |
| 34 | 2nd Floor |
| 35 | 3rd Floor |
| 36 | 4th Floor |
| 37 | 5th Floor |
| 38 | 6th Floor |
| 39 | 7th Floor |
| 40 | 8th Floor |
| 41 | 9th Floor |
| 42 | 10th Floor |
| 43 | Suppling, , fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT (Base Metal Thickness) (0.50mm TCT (Total coated thickness excluding paint), G550 (min 550 yield strength, of Zincalume metallic coating (1S15965) with high Solar Reflectance Index (SRI) value for better colling as per thermatech technology,1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg. The steel sheet shall be fastened with 40 micron zinc coated or 25 micron zinc-tin alloy coated, hex head, self -drilling screw as per IS 3566-2002 Class 3 fastener. The base steel shall be coated with zinc-aluminium alloy Zincalume (AZ150) (i.e. 55% Al, 43.4% Zinc, 1.6% Si) minimum of 150 g/m2 coating total on both sides, pre- painted with colorbond XRW (xterior roofing, walling) paint system of 35 micron Super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material.(i) in Roof (a) 0.5mm thick Sheet. |
| 44 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping) |
| 45 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge Total |
| 46 | Add GST @ 18% Total |
| 47 | Add Labour Welfare Cess @ 1% |
| 48 | FIRE DOOR AND RELATED ITEMSSealing of Electrical Shaft, ELV, Plumbing, Fire duct floor opening by supply & application of 50 mm thick FISCHER Fire Stop Mortar or equivalent specially formulated gypsum based compound (Consumption @ 40 kg/Sqm dry weight) over Mineral Wool backing surface which when mixed with water can be trowelled or poured around service penetrations in either vertical or horizontal applications. Tested to BS 476-20, IS 12458 standard, NBC2016 FFSC can provide 2 hours integrity and insulation. it has been design to set within 30-45 Min depending on ambient temperature, and is capable of accommodating foot traffic within 72 hours. Formulated to be halogen and asbestos free the FFSC exhibits excellent load bearing capacity and can be help to maintain the sound reduction index of a structure. All peripherial contact of pipes, cables, HVAC ducts shall be sealed with a joint filler FiAM intumescent sealant (For metal pipes, upto 25 mm PVC pipes, Cables)/ (FiGM/UFS310) intumescent sealant (For insulated HVAC Duct)/FiPWE2 intumescent graphite based synthetic wrap strip (For above 50 mm dia PVC pipes) (Cost of sealent & pipe wrap to be paid seperately). To be installed in accordance with the detailed instructions or the approved system at all level & floor inclusive of all materials, labour, tool & tackles, and backing arrangements etc all complete as per direction of Enginer-in-Charge. (Load Bearing Solution for floor upto 200 Kg/opening)Backing materials details are as follows-8mm Dia ISI TMT Bar (spacing @ 200mm c/c) with Anti Corrosive Paint (Red oxide) (including charges of drilling, fixing in position, painting, grouting but excluding cost of renforcing bar), Consumption of reinforcement - 5.3 kg/Sqm.GI Welded wire net of 30 sqmm Mesh should placed over Rebar structure.Mineral Wool of 64 Kg/cum density, 50 mm thick to be placed over GI welded wire net. |
| 49 | Supply & Application of FISCHER FiAM or equivalent Intumescent Firestop Sealant around metallic Services periphery of MS Pipes / GI duct / PVC Conduit upto 25mm passing through floor to provide up to 2 hours insulation and integrity in accordance to UL EU, IS 12458 standard. Application thickness 6 mm with annular space 15mm. PVC Conduit upto 25mm dia / GI Duct / Metallic Pipe upto 250mm - As per UL EU Standard.To be applied in accordance with the detailed instructions or the approved system at all level & floor inclusive of all materials, labour, tool & tackles, and backing arrangements etc all complete as per direction of Enginer-in-Charge.Length of Intumescent Firestop Sealant around metallic Services periphery of MS Pipes / GI duct / PVC ConduitQuantity = 143 x 3.142 x 0.075 x 6 = 202.19 |
| 50 | Supply & Application of intumescent graphite- based synthetic wrap (i.e. FiPW E2 of Fischer make or equivalent other make) around periphery of PVC pipe or non-metallic pipe services passing through floor/wall to provide up to 2 hours insulation and integrity in accordance to UL EU, IS 12458 standard to ensure 100% fire & smoke seal arround perimeter of pipe. To be applied in accordance with the detailed instructions or the approved system at all level & floor inclusive of all materials, labour, tool & tackles, and backing arrangements etc. all complete as per direction of Enginer-in-Charge.From 50 mm to 75 mm dia |
| 51 | Above 110 mm to 160 mm dia |
| 52 | Supplying, fitting & fixing Partially insulated fire resistant door frame of 120 minutes fire rating (FD 120 PI - 120 min integrity , 30 min insulation) conforming to IS:3614-2021 (Amendment no -1, July,2023) tested in accordance with the procedures laid down in IS 17518 (Part-I), of section 140 x 65 mm having built in rebate made out of 1.6 mm (16 gauge) G.I. sheet (zinc coating not less than 120 gm/sqm. total on both sides conforming to IS 513 part-1 & 2 or IS: 277) finished with suitable powder coating duly filled with vermiculite based concrete mix/proprietary material, suitable for mounting 120 minutes fire rated door shutters (FD 120 PI). The frame is fitted with intumescent fire seal strip and EPDM smoke seal all-round the frame as standard component of door assembly and 3 mm thick support plate to provided to receive hardware and ironmongery. Rate should include supply and installation complete as per direction of Engineer-in-charge (Door frame should be compatible to fix hardware but excluding cost of hardwares like hinges, door closer, Bolt, lock etc.).Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplied door are to be submitted by manufacturer. Ground Floor |
| 53 | 1st Floor |
| 54 | 2nd Floor |
| 55 | 3rd Floor |
| 56 | 4th Floor |
| 57 | 5th Floor |
| 58 | 6th Floor |
| 59 | 7th Floor |
| 60 | 8th Floor |
| 61 | 9th Floor |
| 62 | 10th Floor |
| 63 | Supplying, fitting & fixing Partially insulated fire resistant Door leaf of 50 mm thick fully flush double skin door shutters (with vision lite not exceeding 0.06 sqm.) of 120 minutes fire rating (FD 120 PI - 120 min integrity , 30 min insulation) conforming to IS:3614 -2021 (Amendment no -1, July,2023) tested in accordance with the procedures laid down in IS 17518 (Part-I), tested with suitable mounting on door frame, made out of 1.2 mm (18 gauge) G.I. sheet (zinc coating not less than 120 gm/sqm. total of both sides conforming to IS 513 part-1 & 2 or IS: 277) finished with suitable powder coating duly filled heat-resistant mineral wool/Ceramic wool/proprietary material satisfies the requirement of fire door ratings and fixing with necessary stainless steel ball bearing hinges of approved make. Vision lite should be provided with a bedding and screw from inside. The glass in vision lite should be clear fire rated of relevant rating. Shutter shall have pre-drilled support plates with hinge guard covers, concealed lock/latch box with lock fitting brackets and pre-tapped holes. Rate should include supply and installation complete as per direction of Engineer-in-charge. (Door shutters should be compatible to fix all hardwares but excluding cost of all hardwares like hinges, vision panel, bolt, door closer, door lock, panic bar, handle etc.) Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplied door are to be submitted by manufacturer. The label shall be affixed on door leaf containing information as- i) Name of manufacturer ii) Type of fire door iii) Fire rating classification iv) Serial no of door v) Year of manufacture and vi) Certificate reference number.Single leaf - upto 1250 mm width.Double leaf- exceeding 1250 mm width with intumescent fire seal strip on meeting style and astragals has to be provided on meeting style for both active and inactive leaf. Ground Floor |
| 64 | 1st Floor |
| 65 | 2nd Floor |
| 66 | 3rd Floor |
| 67 | 4th Floor |
| 68 | 5th Floor |
| 69 | 6th Floor |
| 70 | 7th Floor |
| 71 | 8th Floor |
| 72 | 9th Floor |
| 73 | 10th Floor |
| 74 | Supplying, fitting & fixing fire rated Stainless Steel ball bearing hinges with Grade SS 304 of approved quality fitted and fixed with Stainless steel screws. Rate should include supply and installation complete as per direction of Engineer-in-charge.Size: 100mm. X 75mm. X 3.0 mm thick. |
| 75 | Supplying, fitting & fixing 120 minutes Fire rated Dead Lock of approved quality fitted and fixed complete. Rate should include supply and installation complete as per direction of Engineer-in-charge.Individual or Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplied door are to be submitted by manufacturer. |
| 76 | Supplying, fitting & fixing 120 minutes Fire rated Concealed Flush Bolt (For DBL Leaf) of approved quality fitted and fixed with Stainless steel screws. Rate should include supply and installation complete as per direction of Engineer-in-charge. Individual or Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplied door are to be submitted by manufacturer. |
| 77 | Supplying, fitting & fixing fire rated Allen Key Lock/ Shaft Lock (For Shaft Door) of approved quality fitted and fixed with Stainless steel screws. Rate should include supply and installation complete as per direction of Engineer-in-charge. |
| 78 | Supplying, fitting & fixing fire rated Concealed Handle (For Shaft Door) of approved quality fitted and fixed complete. Rate should include supply and installation complete as per direction of Engineer-in-charge. |
| 79 | Supplying, fitting & fixing 120 minutes Fire rated Clear Vision Pane (Size 200 mm width x 300 mm height) should be provided with a bedding and screw from inside. Rate should include supply and installation complete as per direction of Engineer-in-charge.Individual or Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplied door are to be submitted by manufacturer. |
| 80 | SIGNAGESSupply and installation in position the \\"FIRE EXIT\\" Sign with luminicent colour having size 300 x 100 mm. |
| 81 | Supply and fixing in position the signages \\" FIRE ORDER\\" contain the following matter on 3 mm thick \\"Opaque\\" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of size 600 x 400 mm. ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION.EVACUATE THE OCCUPANTS BY USING FIRE EXIT AND EMERGENCY EXITS ONLY AND ASSEMBLE AT ASSEMBLY POINTS.BE CALM AND DO NOT GET PANIC, WALK DO NOT RUN.IF POSSIBLE TRY TO EXTINGUISH FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. |
| 82 | Supply and fixing signage with printed \\" IN CASE OF FIRE, DO NOT USE LIFT. USE STAIRS ONLY\\" OF 1.5 cm height letters in red with white background. The size of the board shall be 300 x 250 mm and shaall be fixed at the height of 2 mtrs.from finished floor near Manual Call Point. |
| 83 | Supplying, fitting & fixing of Fire Escape Route Floor Plan of size 450X600mm as per design and drawing approved by the Engineer-in-Charge made of Photoluminescent Vinyl Sheet pasted on 4mm thick ACP sheet covered with 4mm thick toughened glass to be fixed on wall with necessary studs complete in all respect. Please Enable Macros to View BoQ information |