| 1 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor ncluding removing rubbish within a ead of 75 m as directed. |
| 2 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.Tor steel/Mild Steelground floor |
| 3 | 1st floor |
| 4 | 2nd floor |
| 5 | 3rd floor |
| 6 | 4th floor |
| 7 | Welding in M.S. structural work with gas or electric. Tack weld |
| 8 | Supplying and application of chemicalfor rebar anchoring by using ETA approved/Or seismic criteriain rebarconnection, Including drilling hole to the required depth by rotary hammer drill,cleaning with brush& jet of clean air, IPlllng resin and hardener using serrated nozzle to eliminate mixing error and In a voldlessmanner Includingchargesfor all tools & plants. Applicationto be \\"0: designedfor rebars as per ECZ/TR023or relevant tested and accepted design IS guidelinesand the design document to be furnished by the manufacturer.The chemicalshould have ETAapprovalfor seismic criteriaof rebarfixing which should be furnished by manu/Octurer. The installation and the setting instructionsshould be strictly followed as per manufacturer'sspecificationsas approved by EICprior to drilling. The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement inCost Of rebar with rebar chemical for 16mm dia per cm of depth |
| 9 | Guniting concrete surface with cement mortar (25 mm nominal thick) applied with compressor after cleaning surface and spraying with epoxy complete as per Technical specification. |
| 10 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy. |
| 11 | Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1. |
| 12 | Applying epoxy mortar ( 10 mm nominal thick) over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical specification |
| 13 | Removing corroded worn out portion of reinforcement (when the area of bar is damaged by more than 25%) by cutting and replacing the same by a new plain round bar of requisite diameter by binding with required lap / welding with old bar, including cost of reinforcement, complete in all respect including removing unserviceable materials from site as per direction of the Engineer - in - charge. Note : Payment on weight (Kg.) of new reinforcement. |
| 14 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in -Charge. |
| 15 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymei based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification]. |
| 16 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface) |
| 17 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar15 mm thick plasterGr. Floor |
| 18 | 1st floor |
| 19 | 2nd floor |
| 20 | 3rd floor |
| 21 | 4th floor |
| 22 | 5th floor |
| 23 | With 1:6 cement mortar20 mm thick plasterground floor |
| 24 | 1st floor |
| 25 | 2nd floor |
| 26 | 3rd floor |
| 27 | 4th floor |
| 28 | 5th floor |
| 29 | With 1:4 cement mortar10 mm thick plasterground floor |
| 30 | 1st floor |
| 31 | 2nd floor |
| 32 | 3rd floor |
| 33 | 4th floor |
| 34 | 5th floor |
| 35 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.Grill weighing above 16 Kg./sq.mtr and above |
| 36 | 1st floor |
| 37 | 2nd floor |
| 38 | 3rd floor |
| 39 | 4th floor |
| 40 | 5th floor |
| 41 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour chargesfor fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge.10-12 Micron thickness Annodizing filmNatural white |
| 42 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.5mm thick coloured / tinted / smoke glass. |
| 43 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC.Two CoatIn Ground floor: |
| 44 | 1st floor |
| 45 | 2nd floor |
| 46 | 3rd floor |
| 47 | 4th floor |
| 48 | 5th floor |
| 49 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat)b) Premium 100% Acrylic Emulsion |
| 50 | 1st floor |
| 51 | 2nd floor |
| 52 | 3rd floor |
| 53 | 4th floor |
| 54 | 5th floor |
| 55 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 56 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 57 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. pn the surface, if necessary :On timber or plastered surface :With super gloss (hi-gloss)iv)Two coats (with any shade except white) |
| 58 | On steel or other metal surface:With other than hi-gloss of approved quality- Two coats (with any shade except white) |
| 59 | Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand. (1.5mm thick) |
| 60 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC.One CoatWater based interior grade Acrylic Primer |
| 61 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two CoatsLuxary coat |
| 62 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 63 | 1st floor |
| 64 | 2nd floor |
| 65 | 3rd floor |
| 66 | 4th floor |
| 67 | 5th floor |
| 68 | Dismantling all types of plain cement concrete works, stackingserviceablematerialsat site and removing rubbish as directed withina lead of 75m.In ground floor including roof.above 150 mm. Thick |
| 69 | 1st floor |
| 70 | 2nd floor |
| 71 | 3rd floor |
| 72 | 4th floor |
| 73 | 5th floor |
| 74 | Applying 2 coats of Acrylic Polymer Modified Paint (Equivalent to MASTER CRETE M-81 of Choksey or similar specified product) having water proofing cum bonding properties for specific use of terrace ,toilet block,swiming pool,water tank ,basement,over prepared surfce (surfce preparation cost to be paid separately) to prevent leakage underneath by mixing in proportion (1 litre liquid compound : 2 kg cement) as per Manufacturer's specification complete in all respect including materials & labour as per direction of E-I-C.ground floor |
| 75 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(I) Pakur VarietyGr. Floor |
| 76 | 1st floor |
| 77 | 2nd floor |
| 78 | 3rd floor |
| 79 | 4th floor |
| 80 | 5th floor |
| 81 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall :- With Sand Cement Mortar (1:3) 15mmthick&2mm thick cement slurry at back side of tiles using [email protected] Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Area of each tile above 0.09 Sq.mColoured decorative |
| 82 | 1st floor |
| 83 | 2nd floor |
| 84 | 3rd floor |
| 85 | 4th floor |
| 86 | 5th floor |
| 87 | Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick) |
| 88 | 1st floor |
| 89 | 2nd floor |
| 90 | 3rd floor |
| 91 | 4th floor |
| 92 | 5th floor |
| 93 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps.Sal : MalayasianGr. Floor |
| 94 | 1st floor |
| 95 | 2nd floor |
| 96 | 3rd floor |
| 97 | 4th floor |
| 98 | 5th floor |
| 99 | Providing and fixing factory made door frame (single rebate) made of single piece extruded solid PVC profile with homogenous fine cellular structure having smooth outer integral skin having 62mm width x 32 mm thickness (the door frame is to be made with single piece extruded solid pvc profile whereas no sheet pasted profile shall be applied for door frame fabrication) and shall be fixed to wall as per instructions of Engineer – in – charge using 100 x 8 sheet metal CSK screws. |
| 100 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)40mm X 6mm, 250mm Length. |
| 101 | 40mm X 6mm, 200mm Length |
| 102 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and 1 bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and interna lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges anc other fittings in ground floor. 35mm thick shutter (single leaf).Gr. floor |
| 103 | 1st floor |
| 104 | 2nd floor |
| 105 | 3rd floor |
| 106 | 4th floor |
| 107 | 5th floor |
| 108 | Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in- Charge.32 mm thickGround Floor |
| 109 | 1st floor |
| 110 | 2nd floor |
| 111 | 3rd floor |
| 112 | 4th floor |
| 113 | 5th floor |
| 114 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:125 x 63 x 3.2mm. |
| 115 | iv) 75 x 63 x 3.2mm. |
| 116 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:With continuous plate base (Hexagonal / Round rod)150 mm grip x 12 mm dia rod. |
| 117 | 25 mm grip x 10 mm dia rod. |
| 118 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:x) 300mm long x 12mm dia. bolt. |
| 119 | iv) 150mm long x 10mm dia. bolt. |
| 120 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.300mm long |
| 121 | Removal of rubbish.earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 122 | Supply, preparing and placement of ready mix non-shrink, cementitious micro-concrete having no metalic aggregate or chlorides for reparing and of damaged RCC members. The micro-concrete should achieve a compressive strength of not less than 10 MPa after 24 hours, 40MPa after 7 days and 50 MPa after 28 days at 300C. It should have unrestrained expansion in between 1 - 4%. The flexural strength shall not be less than 5N/mm2 @ 28 days. The micro-concrete shall have a coefficient of tharmal expansion similar to that of the host concrete. |
| 123 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be madeon area of finished work). In Roof:- With 0.5 mm thick sheet |
| 124 | M.S. structural works with hollow sections (TATA make square or rectangular shape) conforming to IS: 806-1957 & IS:1161-1958) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814-1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour required for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a night of erection 8 m./ 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part there of.For roof truss works Span up to 12 Mtr (5th floor) |
| 125 | Supplying, fitting and fixing of false ceiling framework with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins/ soffit all complete as per the drawing & directions of Engineer-in-charge |
| 126 | Supplying, fitting & fixing High Pressure steam Cured Non Asbestos fibre cement designer ceiling board (Density > 1300Kg per Cu.m. ) of size595mm X595mm conforming IS 14862 and type B, catagory III of ISO 8336, tested as per AS-1530 Part 3 and BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a false ceiling all complete as per drawing & direction of Engineer - in- Charge.False ceiling with 6mm thick Fibre Cement Designer ceiling board. |
| 127 | Dismantling carefully terraced floor only (including floor finish if any) or lime terracing in ground floor roof and removing rubbish as directed within a lead of 75 m. Gr.floor |
| 128 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.Pakur Variety1st Floor |
| 129 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt, specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film/Mineral on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth, clean dry surface prepared wherever required. Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials, labour and applicable taxes. (Payment shall be made on the basis of finished surface area).Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) |
| 130 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damage complete. |
| 131 | M.S.gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.5th Floor |
| 132 | Providing and fixing exterior quality Aluminium Composit Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel ( Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials ( but including the cost of silicon sealant), labour, scaffolding and all other incidental charges e.g. VAT, Labour cess etc complete in all respect as per specification and direction of Engineer-in-charge. ( Mode of payment is on finished surface area of ACP) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating |
| 133 | Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete.Area of each Granite slab above 1.00 Square meter. Ground Floor |
| 134 | Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with Polymerized Adhesive and Epoxy Grout Pointing including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete.[Using cement slurry at back side of tiles@ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]Source of Granite: Available outside West Bengal.Physical Properties of Granite shall confirm to IS 142239(Part 1):2023 [ This item of work shall be taken up with prior permission of Senior Superintending Engineer / Superintending Engineer]Area of each slab upto 0.2 Sq.m |
| 135 | Polishing only of old marble or terrazo work with oxalic acid powder using 33 gms/ sq.m. by manual labour / machine where necessary. |
| 136 | Extra cost for filling joints (3 mm wide X 7 mm deep) of floor and wall (Granite/Marble/ Tiles etc.) with 100% stain free, chemical and emperature resistant, anti-bacterial and anti- fungal epoxy grout in place of white cement grout with approved manufacturer to match the colour of floor/wall including the cost of materials, Labour and all other ncidental charges complete true to the manufacturer's specification and direction of Engineer-in- Charge |
| 137 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. UPVC Pipes:160 mm. Dia. |
| 138 | UPVC fittings plain tee 160 mm dia |
| 139 | Shoe160 mm dia |
| 140 | S& P works Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989/ 2009 and I.S. 1729/2002 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the centre line of the total pipe line in fitted condition including specials, payment for specials & Painting will however be paid separately).With valamoid joints including sealing with sand cement mortar (4:1) upto quarter depth.100 mm dia. (internal) |
| 141 | Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately).With valamoid joints including sealing the top with cement mortar (4:1) 100 mm dia |
| 142 | Supplying, fitting & fixing H.C.I. bend without door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (PaymentofPaintingwillhoweverbe paid seperately). With valamoid joints including sealing the top with cement mortar (4:1)100 mm dia |
| 143 | Supplying,fitting and fixing cast iron 'P' or 'S' trap conformimg to I.S. 3989/ 2009 and 1729/ 2002 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately).'P' Trap 100 mm |
| 144 | Supplying, fitting and fixing cast iron extension pipes for using in Traps only (connector) conforming to I.S.3989/2009 and 1729/2002 including lead caulked joints complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). 100 mm X 450 mm |
| 145 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.With 'P' trap (with vent) |
| 146 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.Anglo IndianPlastic (hallow type) black |
| 147 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.550 mm X 400 mm size |
| 148 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)For Exposed WorkPVC Pipes20 mm |
| 149 | 25 mm |
| 150 | 50 mm |
| 151 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings(tested to 21 kg per sq. cm.).20mm dia |
| 152 | 50 mm dia |
| 153 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(iv) 750 mm long |
| 154 | Supplying, fitting and fixing bib cock or stop cock.Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 155 | Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 156 | Supplying, fitting and fixing shower of approved brand and make.Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 157 | Chromium plated Hand shower 70mm dia Round Shape Single flow with Flexible Tube & fittings (Equivalent to Code No. ESH-5512 & Model - Tropical / Sumthing Special of ESSCO or similar). |
| 158 | Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.450 mm X 300 mm |
| 159 | Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 450 mm long |
| 160 | Supplying G.I. tank with Galvanised iron sheet with 450 mm dia C.I. raised approved type locking cover and 50 mm cleaning flange and plug.With 2 mm thick G.I. sheet1812 litre. Capacity |
| 161 | Sub-Total |
| 162 | GST @ 18% |
| 163 | Cess @ 1% Please Enable Macros to View BoQ information |