Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-06-2026 | Minutes of Pre-Bid Meeting | Other | 09-06-2026 |
| Sl. No. | Item Description |
| 1 | Civil Demolishing Work |
| 2 | Dismantling of all types of toilet fittings in a single toilet (C.I/PVC/Vitrous China) including stacking of useful materials near the site and disposal of unserviceable materials. |
| 3 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 5 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm |
| 7 | Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge. |
| 8 | Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below |
| 9 | Core Cutting of RCC slabs(max 20cm thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) |
| 10 | Cutting of RCC slab to form openings of required size, shape, line, and level using approved mechanical methods (diamond saw/wall saw/floor saw or equivalent), including cutting of reinforcement, complete in all respects, as directed by Engineer-in-Charge; cutting to be controlled with minimal vibration (no impact tools), ensuring no damage to remaining structure, with dimensional tolerance of ±5 mm and neat, true, perpendicular edges, complying with safety standards. |
| 11 | Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 12 | Cutting branches of trees overhanging above any structures of girth between 40cm to 60cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. |
| 13 | Cutting branches of trees overhanging above any structures of girth between 60cm to 90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete |
| 14 | Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge |
| 15 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 16 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 17 | Cleaning of septic tank & inspection chamber including removal of sludge by suction and disposal at a safe place to be free from any nuisance or health hazard by cesspool machine, Suction Pipe and All Necessary equipment. Cutting edges of concrete cover/lid and re fixing the same. Manual cleaning of inlet pipe, Choked Sewer Lines. as per instruction of engineer in charge. |
| 18 | Cleaning & clearing of expansion joint by removing debris & waste particles including all required as per the direction of engineer in charge. |
| 19 | Floor rectification and lift base construction |
| 20 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 21 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 22 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock |
| 23 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 24 | Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. |
| 25 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 26 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 27 | Providing & applying a coat of residual petroleum bitumen of grade of VG-30 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 28 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 29 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 30 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 31 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 32 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 33 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 34 | Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion): Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 35 | ACP cladding work with aluminium framework: Designing, fabricating, testing, installing and fixing in position Aluminium Composite Panel Cladding System over Aluminium rectangular hollow section of suitable size, but not less than 50x25x2 mm, designed based on structural calculations and wind load requirements, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick Aluminium Composite Panel consisting of FR grade mineral core sandwiched between two aluminium skins of 0.5 mm thickness each. The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of MS brackets hot dip galvanised with minimum 80 micron zinc coating with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics including all required complete including EPDM gasket, weather seal, pressure equalisation arrangement and necessary flashing wherever required , FR grade ACP conforming to relevant fire safety requirements and NBC provisions. as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. Note: For payment, only the visible external surface area of ACP cladding including grooves shall be measured in square metres, with no separate payment for framework, stiffeners, brackets, fasteners, sealants, bends, cut-outs, overlaps, scaffolding, testing or wastages. |
| 36 | Diluting, spraying or injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Along the building expansion joint using chemical emulsion @ 1 litres per linear metre With Chlorpyriphosl Lindane E.C.20% with 1% concentration |
| 37 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20% |
| 38 | Partitions & Finishing Work |
| 39 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. |
| 40 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete |
| 41 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 150mm/230mm/300 mm thick with Grade- I AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 42 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 43 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 44 | 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 45 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 46 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 47 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 49 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 50 | Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Powder coated aluminium sheet 2.5 mm thick ( minimum thickness of powder coating 50 micron) |
| 51 | Providing and fixing partition wall made of twin-layer construction using 12 mm thick commercial plywood conforming to IS: 1328 (BWR type) / ISI IS:303 Grade, of approved make, with decorative lamination on the exposed face and balancing lamination on the other face, using minimum 1.0 mm thick laminate hot-press bonded with approved adhesive (3M / Henkel or equivalent) in approved colour and pattern, complete. The minimum overall width of the twin-layer partition shall be 75 mm, including internal framework made of 18 mm thick BWR grade plywood, with fixing arrangement as per design. The top and side edges of the partition shall be finished with minimum 80 mm wide border using 16 mm thick BWR grade plywood on face edges with white laminate, with the top exposed surface finished in high-gloss laminate, and all exposed edges sealed with minimum 1.3 mm thick matching glossy PVC edge band, complete. Necessary decorative grooves shall be provided at all joints in laminate. The partition shall be firmly fixed to floor and adjoining walls, true to line, level and plumb, complete as directed by the Engineer-in-Charge.Measurement shall be in elevation, and only the front elevation area shall be measured for payment. (Approved makes: Plywood: Century / Greenply; Laminate: Century / Merino / Greenlam or equivalent.) |
| 52 | Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge. |
| 53 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) |
| 54 | Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self-adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. |
| 55 | Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete |
| 56 | Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete |
| 57 | Fluted Panels- Supply, installation, and finishing of Fluted panels for interior wall and ceiling applications. Fluted panels with high acoustic performance and fire rating compliance. Compliance: Conforming to ASTM E84 for fire rating and ISO 354 for acoustic performance.MATERIAL & FINISH: Core Material: Medium-Density Fiberboard (MDF) with high moisture resistance (HMR) or Fire-Rated MDF (FR-MDF) as per project requirements with PU coating. Groove Design: Precision-machined linear grooves with custom spacing as per acoustic requirements. Perforation: Back perforated with acoustical fleece backing for enhanced sound absorption.PERFORMANCE CHARACTERISTICS: Acoustic Performance:Noise Reduction Coefficient (NRC): 0.65 - 0.85 (dependent on panel thickness and backing material).Sound Absorption Class: Class B or higher per ISO 11654. Fire Rating: Class A per ASTM E84 for fire spread and smoke development. BS 476 Part 7 (Class 1) or EN 13501-1 (B-s1, d0) compliance. 3.3. Dimensional Stability: Thickness 18mm (±0.5mm tolerance).INSTALLATION REQUIREMENTS Mounting System: Aluminum T-grid framework or wooden batten system. Concealed fixing with clips and screws. Joint Treatment: Tongue and groove interlocking for seamless joints. End trims and edge profiles as required.APPROVAL & INSPECTION Sample Approval: Mock-up panel to be submitted for approval prior to bulk procurement. Site Inspection: Installed panels to be checked for alignment, finish consistency, and acoustic performance validation.Make: Amstrong, Hunter Douglas or similar |
| 58 | Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm |
| 59 | Joinery |
| 60 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 61 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick Fixing with hinges of required size and necessary screws(Note: Hinges and necessary screws hall be paid separately) |
| 62 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 63 | Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. |
| 64 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/-0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). |
| 65 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/-0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm , & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm). |
| 66 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 67 | Zebra Blinds: Providing and Fixing Zebra blinds for windows with approved colours as per Indian standards with following Specification Head Rail, Bottom Rail: Made of extruded aluminium powder-coated with high mechanical strength, UV-resistant, and anti-fogging polyester powders, it is expressly made for accessories to set inside IG units. Ladder tape and cords are provided with 100% polyester, excellent dimensional stability, and high mechanical & UV resistance. Modular and durable chain for vertical movement. |
| 68 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 69 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm |
| 70 | Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. |
| 71 | Providing and fixing chromium plated brass handles with necessary screws etc. complete:200 mm |
| 72 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. |
| 73 | Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1500X2250 mm. |
| 74 | Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame: Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. |
| 75 | Providing and fixing Partially insulated fire rated door Single leaf GI Sheet doors of size 1000X2250mm conforming to FD 120-PI classification of IS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accessories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating. The test evidence from CBRI-Roorkee should not be older than 5 years . Due to ISI marking and guidelines of IS code there will not be any need of fresh testing within the above mentioned timeline. There should be a separate test evidence for both single leaf doors and double leaf door .The Door frame shall be single rebate grooved profile of size minimum 125mm x 75mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembled with bolting system. Frames to have inbuilt groove to accommodate Intumescent fire seal strip of size 10x4mm. The frame should also be provided with EPDM seal to limit the spread of smoke vide clause no. 7.2.6 of IS code. All provisions should be mortised & provided with necessary inbuilt reinforcement to receive appropriate hardware. Frames should be provided with back plate bracket for anchor fastener with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves(Payable in extra item) for installation of frame in finished plastered masonry wall opening. Note :- For grouting of Steel frames in masonry installations ;cement slurry of 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be used except head member(Frame filling Payable in extra item).Door leaf should be minimum 60mm thick fully flush double skin door. Door leaf must be manufactured from minimum 1.2mm(18gauge) thick galvanised steel sheet. The infill material shall be mineral wool of minimum density 96 kg/cum. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x 75x3 mm along with all suitable hardware (Payable in extra item).Vision lite size 200x300 mm or (max area 0.06sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clip-on arrangement. The glass will be provided with fire rated ceramic tape of min. 2 mm thickness around on either face. Every Glass pane must carry a permanent marking of its glass manufacturer mentioning its details. S S BALL BEARING HINGES -100X75X3MM DOOR CLOSER - BLC 604 Triple Point Panic bar - SBL 990+995 External trim -011 KE NEW KNOB TYPE INTUMESCENT SEAL- 10x4mm Smoke seal - IS1212 6MM THICK 200X300MM VISION PANEL FIRE CLEAR GLASS -220X320MM FASTENER - M10X80MM |
| 76 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece |
| 77 | Sanitary and CP Fittings |
| 78 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 79 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 80 | Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 81 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern |
| 82 | Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade |
| 83 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap |
| 84 | Providing and fixing white vitreous china counter top wash basin of minimum size 485 × 310 × 130 mm, conforming to relevant IS standards, including fixing on C.I. brackets painted with two coats of synthetic enamel paint over a coat of primer, complete with 15 mm dia C.P. brass long/extended pillar taps, 32 mm dia C.P. brass waste of standard pattern, including all necessary fittings, fixtures, supports, cutting and making good the walls wherever required, and connection to inlet and outlet pipes, complete as directed by Engineer-in-Charge. |
| 85 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm,with swan neck faucet with pipe in let and drain provision, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm |
| 86 | Providing and fixing uplasticised PVC connection pipe with brass unions: 30 cm length15 mm nominal bore |
| 87 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia |
| 88 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 89 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter |
| 90 | Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore |
| 91 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 92 | Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 93 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. |
| 94 | Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. |
| 95 | Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. |
| 96 | Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . |
| 97 | Plumbing |
| 98 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal dia pipes |
| 99 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal dia pipes |
| 100 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal dia pipes |
| 101 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes |
| 102 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes |
| 103 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 104 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 105 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 106 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 107 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall |
| 108 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall |
| 109 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 110 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow |
| 111 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 112 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer |
| 113 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 |
| 114 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 |
| 115 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 116 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend |
| 117 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee |
| 118 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 119 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap |
| 120 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 121 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 122 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 123 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 124 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 125 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap |
| 126 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 127 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer |
| 128 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 129 | Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P typeWith common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 130 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 131 | Providing & Fixing GI pipes complete with GI fittings and clamps including making good the walls etc. concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall:20 mm dia nominal bore |
| 132 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 133 | Providing and fixing a 50 mm dia. GI puddle flange for outlet in all types of water tanks is complete. |
| 134 | Yard Plumbing |
| 135 | Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 |
| 136 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 137 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 |
| 138 | Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm |
| 139 | Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° 110 mm bend |
| 140 | Tile work |
| 141 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints (Payment for grouting of joints to be made separately). The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 1200 mm (Note:Rate of tile should not be less than 100/sqft) |
| 142 | Providing and laying Glazed vitrified tiles matt/polished finish of size 600 x 1200 mm in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).(Note:Rate of tile should not be less than 100/sqft) |
| 143 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm (Note:Rate of tile should not be less than 100/sqft) |
| 144 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1200x600 mm (Note:Rate of tile should not be less than 100/sqft) |
| 145 | Providing and laying premium vitrified bathroom wall tile size 600 x 1200 mm (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting of joints (Payment for grouting of joints to be made separately). (Note:Rate of tile should not be less than 100/sqft) |
| 146 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm |
| 147 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 1200x600mm |
| 148 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm |
| 149 | Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work |
| 150 | Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 151 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 152 | Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm |
| 153 | Providing and fixing SS 304 grade stainless steel double coat hook of approved make and design with satin/mirror finish, fixed to wall or wooden door using with necessary stainless steel screws, rawl plugs, accessories etc complete as required. The hook shall be properly aligned, firmly fixed and free from sharp edges or defects.Approved makes: Jaguar, Hindware or equivalent make. |
| 154 | Structural steel |
| 155 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 156 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 157 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 158 | Providing & fixing Poly carbonate multi wall plain sheet 6 mm thick both side UV coated as approved by the Engineer in charge and should be supplied in a single length of 12m or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/self tapping screw of size (5.5x55mm) with accessories such as aluminium skylighting profiles, top and bottom sealant, screws complete upto any pitch in horizontal/vertical curved surfaces, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. |
| 159 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 160 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 161 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 162 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 163 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminum extruded section shall be taken for purpose of payment |
| 164 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a)Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. |
| 165 | Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 170251. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml |
| 166 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement |
| 167 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 - point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. |
| 168 | Providing,fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non- combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5mm and nominal mass not less than 60 gm/ sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts,bolts, washers etc complete. |
| 169 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of relevent item*). ?(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 170 | False ceiling |
| 171 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board. |
| 172 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. |
| 173 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 174 | Extra for sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous) ceiling. |
| 175 | Rainwater Harvesting ,Fire Tank,Septic Tank |
| 176 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock |
| 177 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/ Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 178 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm |
| 179 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. |
| 180 | Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg |
| 181 | Supplying and installing ready made M30 Reinforced Concrete Ring of 1000mm dia and 50mm thick wall for Soak pit including the cost of carriage, placing at the level below ground level as specified as per the direction of engineer in charge. Excavation shall be paid extra. |
| 182 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 183 | Providing and placing on terrace (at all floor levels) Stainless Steel 304 as per IS 5522:1992 of capacity 5000 Litres with suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 184 | Road Work |
| 185 | Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 |
| 186 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 187 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) |
| 188 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 189 | Providing and laying C.C pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge ( The panel shuttering work shall be paid for separately)(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). |
| 190 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 191 | Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.) |
| 192 | Water proofing |
| 193 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 194 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) |
| 195 | Signage |
| 196 | Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. |
| 197 | Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. |
| 198 | Furniture |
| 199 | Supply and installation of 22-inch-wide auditorium chairs with writing pads, designed for durability, comfort, and functionality. Chairs feature a sliding and push-back mechanism for ease of use and optimal space utilization.Materials and Finish: Frame: Powder-coated mild steel (MS) for enhanced strength and corrosion resistance.Seat and Backrest: High-density polyurethane (PU) foam upholstered with premium fabric or leatherette, ensuring long-lasting comfort and durability. Backrest includes a plywood backply for structural support.Writing Pad: Foldable/flip-up type, crafted from high-quality wood or engineered board with a laminate finish, offering a smooth writing surface.Armrest: PU-coated armrests with options for wooden box or PU handles for aesthetic appeal and durability.Features: Sliding and Push-Back Mechanism: Ensures easy seat adjustment for occupant comfort and efficient use of space.Ergonomic Design: Provides proper lumbar support for extended seating periods. Fixing Mechanism: Chairs to be securely fixed to the existing flooring using rust-resistant heavy-duty anchor bolts, ensuring stability and safety. Installation: Installation includes alignment, anchoring, and testing to ensure proper functionality and durability. Installation team to adhere to site safety protocols and complete the work within the agreed timeline.The chairs meet standard auditorium seating quality and safety requirements. Materials used comply with relevant fire, wear, and environmental standards. |
| 200 | 3 seater Sofa for visitors: - Supply and placing finished 3 seater sofa with Fabric of approved shade & pattern, supported on wooden/ metal legs and frame. Contemporary design of elegance and comfortable, Covered with top-quality Imported faux leatherette/Fabric upholstery as per approved colour/patterns. Sponge: high quality polymeric urethane foam 40 minimum density as the difference part, seat and back. Spring: imported spring for strong support. Minimum dimension-one sofa W x H x D: 210 cm x80cm x 75cm/45cm and seat height of 450mm etc. Complete as per the direction of Engineer-in-charge. |
| 201 | 2 seater Sofa for visitors: - Supply and placing of single seater sofa finished with Fabric of approved shade & pattern, supported on wooden legs and frame. Contemporary design of elegance and comfortable, Covered with top-quality Imported faux leatherette/Fabric upholstery as per approved colour/patterns. Sponge: high quality polymeric urethane foam 40 minimum density as the difference part, seat and back. Spring: imported spring for strong support. Minimum dimension-one sofa W x H x D: 147 cm x 76 cm x 76 cm. |
| 202 | Work Station- Providing and fixing Linear workstation table unit of size 1200 × 600 × 750 mm (L×W×H) without pedestal. All sufficient frameworks are to be made up of powder-coated MS steel tubes of size 40x40x2 mm and side panelled vertical supports and backside partition are to be made with 1.5 mm thick perforated MS sheet panels. Table top should be made with 25 mm thick prelaminated MDF and all edges to be fixed with 2mm thick edge beadings. All workstation should have a 8 module flip boxes and with 3 nos universal type power 6A socket controlled by One switch, 2 data points one for network and other for IP PBX , separate power and data cable raceways also to be provided. Table top sides to be fixed with 10 mm thick frosted toughened glass panels having 400mm ht at sides and 400mm fabric-covered magnetic middle panel made with 12mm thick MDF to be fixed in the backside of table top and including all as per the drawings and instruction of Engineer In Charge. |
| 203 | Work station-L type workstation ((1500 x600)+(900x450))*750 mm, all frames made with powder coated MS steel tubes of size 40x40x2mm with level adjusting screws.Table Top using 25mm thick MDF with 1 mm thick lamination of selected colour and back side 0.8mm thick white or off-white lamination finish. 8 Module Flip Boxes with Supply Box having min 3 nos universal type power 6A socket controlled by One switch, 2 data points one for network and other for IP PBX on table top including divided power and control cable & wire ways from end to end should be provided. Front and sides vertical cover panel with powder coated perforated steel sheet of thick 1.5mm in all vertical leg supports. |
| 204 | Work station-L type workstation ((1650 x600)+(900x450))*750 mm, all frames made with powder coated MS steel tubes of size 40x40x2mm with level adjusting screws.Table Top using 25mm thick MDF with 1 mm thick lamination of selected colour and back side 0.8mm thick white or off-white lamination finish. 8 Module Flip Boxes with Supply Box having min 3 nos universal type power 6A socket controlled by One switch, 2 data points one for network and other for IP PBX on table top including divided power and control cable & wire ways from end to end should be provided. Front and sides vertical cover panel with powder coated perforated steel sheet of thick 1.5mm in all vertical leg supports. |
| 205 | Work station -L type workstation ((1200 x600)+(900x450))X 750 mm, all frames made with powder coated MS steel tubes of size 40x40x2mm with level adjusting screws.Table Top using 25mm thick MDF with 1 mm thick lamination of selected colour and back side 0.8mm thick white or off-white lamination finish. 8 Module Flip Boxes with Supply Box having min 3 nos universal type power 6A socket controlled by One switch, 2 data points one for network and other for IP PBX on table top including divided power and control cable & wire ways from end to end should be provided. Front and sides vertical cover panel with powder coated perforated steel sheet of thick 1.5mm in all vertical leg supports. |
| 206 | Pedestal-Providing and fixing pedestal storage unit of size 450 × 450 × 650 mm (W × D × H) with three (3) drawers, made out of 18 mm thick pre-laminated medium density fibre board (MDF) conforming to IS:14587:1998, using Grade-I (exterior grade) boards, finished with decorative laminate on one side and balancing laminate on the other side, complete with drawer channels, individual locks, and handles, and all fittings wherever required; all exposed edges sealed with 2.0 mm thick PVC edge banding tape of approved brand; complete including fabrication, fixing, installation, transportation, loading, and unloading, executed in all respects as per drawings and directions of the Engineer-in-Charge. |
| 207 | Supply of wooden circular teapoy of 600 mm dia |
| 208 | Supply of woodenside table of size 450 X 450X 450 mm |
| 209 | Executive Table 2100mm X 750mm X 750 mm, made of 19 mm Thick BWR Ply with 1mm Laminate on one side and .08mm thick laminate on inside. Supported with all frames made with powder coated MS steel tubes of size 60x60x2mm with level adjusting screws. All sides covered with fluted panel of approved shade till the table height of 750mm. Tyhe table top to be placed raised supported on SS supports of suitable size. 8 Module Flip Boxes with Supply Box having min 3 nos universal type power socket controlled by One switch, 1 data points on table top including divided power and control cable & wire ways from end to end should be provided.Storage Unit to be provided as fixed on the Table. Storage unit of 600mm X 750mm X650mm made of 19 mmm thick BWR ply with 1mm thick laminate on visible sides and 0.8mm thick laminate on inside areas all complete with lock, handles, channels and all necessary fixing arrangemnts and fittings all complete. The storage unit comprises of 3 drawers. All Edges finished with 2mm thick edge band of approve shade and colour. All as per designa dn instructions of the Architect/ Engineer in charge. |
| 210 | Executive Table 3000mm X 750mm X 750 mm, made of 19 mm Thick BWR Ply with 1mm Laminate on one side and .08mm thick laminate on inside. Supported with all frames made with powder coated MS steel tubes of size 60x60x2mm with level adjusting screws. All sides covered with fluted panel of approved shade till the table height of 750mm. Tyhe table top to be placed raised supported on SS supports of suitable size. 8 Module Flip Boxes with Supply Box having min 3 nos universal type power socket controlled by One switch, 1 data points on table top including divided power and control cable & wire ways from end to end should be provided. Storage Unit to be provided as fixed on the Table. Storage unit of 600mm X 750mm X 650mm made of 19 mmm thick BWR ply with 1mm thick laminate on visible sides and 0.8mm thick laminate on inside areas all complete with lock, handles, channels and all necessary fixing arrangemnts and fittings all complete. The storage unit comprises of 3 drawers. All Edges finished with 2mm thick edge band of approve shade and colour. All as per designa dn instructions of the Architect/ Engineer in charge. |
| 211 | Conference Table having size as per drawing round at the corners, top made of 19mm thick BWR ply board, pressed with 1mm thick laminate on top side and 0.8mm thick laminate on inside. The table shall have under structure with verticals made of 19mm thick BWR ply board & modesty made of 19mm thick BWR ply board. Table shall also have shelf below made of 19mm thick BWR ply board. The Round corner piece shall be made up of 38mm thick bwr ply board pressed with pressed with 1mm thick laminate on top side and 0.8mm thick laminate on inside and supported with post of 65mm dia, made of CRCA sheet duly powder coated as per salient technical features. The table should be only in one approved colour. The table shall also have 6 Nos Flip box for Supply Box with min 2 nos universal type power socket, 2 data points, HDMI port on table top including divided power and control cable & wire ways from end to end. 20 Seater Capacity |
| 212 | Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. |
| 213 | Providing and fixing unit wise modular type OA Table of 900mm(L) x 600mm(W) x 750mm, all frames made with powder coated MS steel tubes of size 50x25x2mm and vertical leg supports at 600mm centre to centre with level adjusting screws and horizontal supports at 500mm centre to centre on both direction and top fixed with Top using 25mm thick MDF with 1 mm thick lamination of selected colour and back side 0.8mm thick white or off-white lamination finish. . Sides vertical cover panel with powder coated perforated steel sheet of thick 1.5mm in all vertical leg supports. |
| 214 | Executive Chair : High back chair,adjustable head rest assembly , meshback(Grey color) with lumbar support , 3D arm rest ,automatic weight sensing mechanism with multi position locking and seat slider ,PU molded cushion seat ,Class 4 gaslift, Aluminium polished base with PU castors.chair tested as per BIFMA X5.1 standards/, 05 years replacement warranty. |
| 215 | Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK |
| 216 | Supply and installation of visitors chair Medium Back, Mesh Back with fixed supports made of 304 Stainless Steel/ powder coated MS of approved colour or shade as per the instruction of the engineer in charge |
| 217 | Providing Dining table of size 900 mm × 900 mm with 12 mm thick toughened glass top having decorative coloured film finish in two layers, fixed over suitable backing/support arrangement. Table frame and legs shall be made of MS tubular sections finished with powder coating of approved shade and quality. The table shall be rigid, stable, corrosion resistant and suitable for cafeteria/dining use. Approximate table height shall be 750–800 mm. All edges of glass shall be machine polished and corners rounded for safety. Complete including all fittings, hardware, labour, transportation and placing in position as directed by Engineer-in-Charge. |
| 218 | Providing Dining table of size 800 mm × 800 mm with 12 mm thick toughened glass top having decorative coloured film finish in two layers, fixed over suitable backing/support arrangement. Table frame and legs shall be made of MS tubular sections finished with powder coating of approved shade and quality. The table shall be rigid, stable, corrosion resistant and suitable for cafeteria/dining use. Approximate table height shall be 750–800 mm. All edges of glass shall be machine polished and corners rounded for safety. Complete including all fittings, hardware, labour, transportation and placing in position as directed by Engineer-in-Charge. |
| 219 | Providing cafeteria chair made of high-impact injection moulded polypropylene/polymer with ergonomic seat and backrest, sturdy and stable construction, suitable for commercial/institutional use. Chair shall be stackable type, weather resistant and easy to maintain, complete with non-marking anti-skid buffers. Approximate dimensions: Seat height 450–460 mm, seat depth 430–450 mm, overall height 800–850 mm. Minimum load bearing capacity shall be 120 kg. Complete including all materials, labour, transportation and placing in position as directed by Engineer-in-Charge. |
| 220 | Cabinet/Wardrobe: Providing and errection of Cabinet/Wardrobe unit made with 18 mm thick prelaminated MDF board of one side decorative lamination and other side balancing lamination having total unit dimension of 900mm,L x 450mm,Dx 2400mm,H and all edges to be sealed with PVC edge beeding of 2.00 mm thick including all fittings such as autoclose hinges,chromium plated brass individual locks & handles ,tower bolts etc all required. All shelves to be fix with proper support and bracket holders at a spacing of 400 mm centre to centre and all as per the drawings and instruction of Engineer in charge. board make : Greenlam/ Merino / Century/ equivalent . Only front elevation will be measured. |
| 221 | Overhead Storage: - Providing and fixing overhead storage unit with minimum 18 mm thick pre-laminated medium density fiber board exterior grade (Grade-I) IS: 14587:1998 marked with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Only Front Elevation will be measured. |
| 222 | Drainage |
| 223 | Cleaning of chocked sewer line and other drainage system including storm water drain by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth. |
| 224 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.For pipes 250 to 300 mm diameter |
| 225 | Sub Station |
| 226 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 227 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 228 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/ Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 229 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/ Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 230 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification . |
| 231 | Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 232 | Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 233 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 234 | 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 235 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 236 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.One coat |
| 237 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 238 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows,clerestory windows all complete with :4.0 mm thick glass panes |
| 239 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge. |
| 240 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 241 | Providing and fixing ball bearing for rolling shutters. |
| 242 | Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area |
| 243 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured). |
| 244 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 245 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 246 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 247 | Security cabin with restroom |
| 248 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 249 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 250 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 251 | Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 252 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 253 | 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 254 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 255 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 256 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 257 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 258 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Anodized (AC 15) aluminium tubular handle bar |
| 259 | Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality ) for aluminum doors including necessary cutting and making good etc. complete |
| 260 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in-Charge.With stainless steel cover plate minimum 1.25 mm thickness |
| 261 | Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete. |
| 262 | Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 263 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/-0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). |
| 264 | Modular lab furniture |
| 265 | Pass Material Box:Free standing self supported Pass box with electrical interlock and made out of 100mm thick structural insulated sandwiched panels made with CFC free fire retardant self extinguishing quality, EPS as core ,sandwiched between 0.6 mm stainless steel sheet SS 304 -2B. panels all round. This shall include a pair of single leaf hinged door made with 25mm thick structural insulated sandwiched panels and 1.2 mm frame work of above specification with 100 x 150 mm double float toughened safety glass flush at both sides view glass, automatic door closer with speed adjuster and magnetic door lock with electrical interlock associated control wiring, UV light for disinfection, push button etc all complete as per URS. Size (CLEAR) :- Length - 1000mm, Width - 700mm, Door opening size clear 600x600 mm. |
| 266 | Supply And Installation of Lab Workbench Material of Construction: GI as per IS277, Min thickness- 1mm or more (as required based on the design) Finish: Complete module and framework shall be powder coated and provided with suitable finish for maximum corrosion resistance (Colour as per the instruction from the HLL Engineer in charge) Minimum Dimension of Module: 900 mm (Width) x 900 mm (Height). Every one meter of the module shall be designed with min 2 drawers (with SS 304 telescopic channels and lockable drawing mechanism) and a single cabinet (With 2 shutters, SS304 hinges for easy and noiseless opening and closing mechanism), SS304 locks and dual keys arrangement, handles, screws etc Common Raceways (Powder coated GI with cover) for cabling electrical, network, voice connections with provision for fixing sockets, switch boxes etc. Raceway should be 3 run type.The workbench shall be portable and suitable for fixing granite table top as per specification ( granite slab shall be paid separately) The item should be in compliance with IS 4209 (2013), NABL, WHO etc. Measurement will be taken in length only. |
| 267 | Supply And Installation of Lab Workbench Material of Construction: GI as per IS277, Min thickness- 1mm or more (as required based on the design) Finish: Complete module and framework shall be powder coated and provided with suitable finish for maximum corrosion resistance (Colour as per the instruction from the HLL Engineer in charge) Minimum Dimension of Module: 750 mm (Width) x 900 mm (Height) Every one meter of the module shall be designed with min 2 drawers (with SS 304 telescopic channels and lockable drawing mechanism) and a single cabinet (With 2 shutters, SS304 hinges for easy and noiseless opening and closing mechanism), SS304 locks and dual keys arrangement, handles, screws etc Common Raceways (Powder coated GI with cover) for cabling electrical, network, voice connections with provision for fixing sockets, switch boxes etc. Raceway should be 3 run type.The workbench shall be portable and suitable for fixing granite table top as per specification ( granite slab shall be paid separately) The item should be in compliance with IS 4209 (2013), NABL, WHO etc. Measurement will be taken in length only. |
| 268 | Supply and Installation of Sink Module with Sink Each sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism ). This module should include a sink made of SS 304 (Matte finish). Minimum Dimension of the sink: 600 mm (L) x 450 mm (W) x 250 mm (H) . Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc.The sink module shall be portable and suitable for fixing granite table top (with cut out for providing sink) as per specification (granite slab shall be paid separately). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. |
| 269 | Land scapping |
| 270 | Providing & fixing of White River (Stone) Pables size of \\"2 to 2.50\\" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. |
| 271 | Providing and laying natural buffalo grass turf on prepared ground including dressing, leveling, supplying and spreading good earth/manure, watering, rolling and maintenance for 30 days or till the lawn forms a thick green carpet free from weeds and fit for mowing complete as per direction of Engineer-in-Charge. |
| 272 | Providing, supplying and planting of approved Ornamental specimen medium trees of 1200mm height (Ornamental specimen medium trees of 1200 mm height (Eagles Ford Aralia Plant, Afflorance Hedge Plant,Pandanus Variegated (Golden) - Plant) etc of healthy condition having well-developed root system and average growth suitable for planting at site, including excavation of pits of required size, refilling with good earth mixed with manure, watering, staking if required, maintenance during establishment period and removal of unserviceable materials complete as per direction of Engineer-in-Charge. |
| 273 | Providing, supplying and planting of approved Red Palm of average 3mtr growth of healthy condition having well-developed root system and average growth suitable for planting at site, including excavation of pits of required size, refilling with good earth mixed with manure, watering, staking if required, maintenance during establishment period and removal of unserviceable materials complete as per direction of Engineer-in-Charge. |
| 274 | Providing, supplying and planting approved flowering shrub species such as Heliconia St. Vincent Red, Ixora Bush, Canna etc. of healthy condition having well-developed root system and average growth suitable for planting at site, including excavation of pits of required size, refilling with good earth mixed with manure, watering, staking if required, maintenance during establishment period and removal of unserviceable materials complete as per direction of Engineer-in-Charge. |
| 275 | Three-layer decorative cascade fountain: Providing, supplying, installation, testing and commissioning of a three-layer decorative cascade fountain within an overall area of approximately 10.0 m × 5.0 m complete with RCC cascade tanks, waterproofing, SS spillway arrangement, recirculating water system, submersible pumps, piping, underwater LED lighting, electrical control panel and exterior slate stone cladding finish including all allied civil, plumbing and electrical works as required as per approved architectural drawing and approval of engineer in charge.Fountain Configuration Upper Cascade Tank: Size: 3.6 m × 1.5 m and 0.75 m height from middle cascade top level, RCC M25 minimum 100 mm thick construction with waterproofing and pool tile, SS 304 spillway (L shaped) edge for smooth water curtain effectIntermediate Cascade Tank: Size: 10 m × 2.5 m and 0.55 m height from bottom cascade top level. minimum wall thickness 120 mm of M25 RCC construction with waterproof plaster Finished with pool tile and coating . Cascade overflow arrangement from upper chamber and front length side to bottom unit.Bottom Collection Basin: Integrated within overall fountain size of 10.0 m × 2.5 m and height 150mm from ground. M25 RCC construction with waterproof finish, Finished with pool tile. Provision for water recirculation and drainage with sufficient depth shall be provided Finishing: Exterior visible surfaces shall be finished with natural slate stone cladding of approved shade and texture. Slate stone shall be machine cut, properly aligned and fixed with suitable adhesive/mortar. Joints shall be neatly finished and water resistant. Internal water-contact surfaces shall receive waterproof smooth finish.Cascade System: Water shall flow continuously through all three cascade levels creating sheet-flow appearance. Spillways shall be SS 304 minimum 2 mm thick with concealed water distribution arrangement as per approved Architectural drawing. Pump & Plumbing: Heavy-duty submersible fountain pumps suitable for required head and discharge. Approximate discharge: 6000?12000 LPH. Piping shall be medium class UPVC/CPVC pipes as approved. Pipe joints shall be leakproof. Isolation valves and unions shall be provided for maintenance. Pipe supports and clamps shall be corrosion resistant.Lighting: IP68 underwater LED lights, 6W-18W, RGB or warm white type. Electrical System: Weatherproof control panel with MCB, timer, contactor, ELCB and earthing. FRLS copper wiring complete. Measurement: The complete cascade fountain unit including RCC work, waterproofing, slate stone finish, pumps, lighting, piping and commissioning etc complete as per direction of Engineer in charge and as per approved Architectural design and shall be measured as one complete job. |
| 276 | Providing and fixing semi-automatic lawn sprinkler irrigation system for landscaped lawn areas consisting of underground HDPE/PVC pipe network, pop-up sprinkler heads, manual isolation valves and electrically operated solenoid valves for zone control, including necessary fittings, excavation, laying, jointing, testing, refilling and commissioning complete as required. The system shall be operated through electrical solenoid valves controlled by a simple timer/switch (basic controller) or manual ON/OFF operation, without full programmable automation. Sprinkler heads shall provide uniform coverage and shall be installed flush with finished ground level. The work shall include pump integration (if required), filtration unit, wiring for valves, valve chambers, and complete functional testing of each zone. |
| 277 | Front Boundary Wall Facade |
| 278 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 279 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 280 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 281 | Providing and fixing dry cladding upto 10 metre heights with 16mm thick terracotta brick cladding of uniform colour and size fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). |
| 282 | Natural Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. Exterior natural stone cladding wall tiles of seamless texture as per manufacture specification and the direction of Engineer in charge |
| 283 | 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 284 | Wiring |
| 285 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C |
| 286 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 287 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 288 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 289 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 290 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire |
| 291 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 292 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 293 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 294 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 295 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 296 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 297 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 298 | Supply and installation of ceiling fan hook complete as required |
| 299 | Fixtures |
| 300 | Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. |
| 301 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 302 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 303 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 304 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 305 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 306 | Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor 0.95 and THD. Make-Philips, Crompton, Wipro or equivalent |
| 307 | Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) |
| 308 | Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor 0.95 and THD. Make - Philips, Crompton, Wipro, Havells |
| 309 | Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor 0.95 and THD. Make-Philips, Crompton, Wipro |
| 310 | Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light and complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) |
| 311 | Supply, Installation, Testing and Commissioning of 900 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/Orient Electric/ Crompton or equivalent |
| 312 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent |
| 313 | Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Efficio/Crompton Brisk Air |
| 314 | Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina |
| 315 | Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required |
| 316 | SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. |
| 317 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 318 | Supplying and fixing 32 amps, 240 volts, DP industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 32 amps "C" curve, DP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.br |
| 319 | Supply, Installation, testing and commissioning of 20A to 32A metal clad power plug with 5 pin socket and TP MCB in metallic enclosure with epoxy coating, and all internal connection etc., complete. |
| 320 | Supply, Installation, testing and commissioning of 32A metal clad power plug with 3 pin socket and TP MCB in metallic enclosure with epoxy coating, and all internal connection etc., complete. |
| 321 | Lift System |
| 322 | Supply, installation, testing and Commissioning of minimum 13 passenger Lift Machine Room Less, Capacity/Weight 13 Passenger (884 Kg), Speed 1.0 MPS, electric traction type, Stainless steel (including freight and landing charges, applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V +/- 10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, infrared ray sensing door protection for full height, reverse phase relay on controller, firemans switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lift lighting accessories, braille buttons, audio announcement along with recorded message as approved by Engineer in Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door as complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. PMSM traction motor (having efficiency equivalent to IE3 or better as in IS 12615) of machine room less elevator shall be of gearless type as per technical specifications. Having Automatic center/side opening stainless steel doors, Matte finish stainless steel car enclosure provided with stainless steel Handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details 3 stops, 3 openings and entrance and exit at same side and suitable for travel height of minimum 10 meter approximate. (Minimum Shaft Size 2600mm (width) x 2400mm (depth)) with door opening of 1100 mm (width) and 2100 mm (height) The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications Test reports from NABL accredited testing labs for all constituent compounds shall be produced. Make: TK Elevators/Kone/Schindler/Johnson/Otis |
| 323 | 30 kVA Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier and inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be 96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. |
| 324 | Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware and software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 and 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging and Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j)Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 30KVA (Each Power module shall be 10 KVA) |
| 325 | Cable Trays |
| 326 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness |
| 327 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 328 | DB and switchgear |
| 329 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP42/43) |
| 330 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43) |
| 331 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43) |
| 332 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door |
| 333 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 334 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural |
| 335 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 336 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 337 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 338 | Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 339 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 340 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 341 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 342 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 343 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral |
| 344 | Earthing and Lightning Arrestor |
| 345 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required. |
| 346 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 347 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 348 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 349 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 350 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 351 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 352 | Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 353 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 354 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 355 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 356 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 357 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) |
| 358 | Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 359 | Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) |
| 360 | Street Lights |
| 361 | Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 362 | Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 363 | Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters |
| 364 | Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 150mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gearbox and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 6 nos fixed in existing RCC foundation and junction box etc, complete 16 Meters |
| 365 | Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 366 | Supply and Installation of LED Bollard 12W , Integral type bollard cylindrical/Conical Shape, Die cast aluminum Housing , Dome shape , Top cover fixed with , Cylindrical/ Conical Shape acrylic cover Opal White Poly Carbonate Diffuser. SMD LED of 1 to 3 Watt each assembled on single MCPCB, Led Lamp lumens output with efficacy 80 lm/W, Rated Current 0.050 A, Lumen Output 800 Lm, Approx. Weight 2.0Kg , Driver PF 0.95 Luminaire having color temp up to 6500K and 50,000 Burning Hours. Life with minimum @ L 70, The color rendering index of LED light should be more than 70. Luminaire, Conical Surface flux @ 120 Degree is 80 L/w, comprises of driver PF 0.95 and Surge Protection 3KV , IP65 Protection , Submission with Technical Data Sheet , LM80 Report, Warranty letter from Manufacturers,Connection Wire, Testing etc. to complete the job having base plate with holes for direct mounting. Bollard LED 12 Watt cylindrical shape height 600mm, Color Temp 3000-6000k 10%, Product Dimension Minimum- L- 815mm, D- 140mm ( 10% |
| 367 | Solar Photovoltaic System |
| 368 | Supply, Installation, Testing and Commissioning of 30KWp Ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 540 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730 Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/-2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 369 | LT Cabling and Termination |
| 370 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 371 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp |
| 372 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 373 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 374 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 375 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 240 sq mm |
| 376 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 35 sq mm |
| 377 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 50 sq mm |
| 378 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 70 sq mm |
| 379 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 95 sq mm |
| 380 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 120 sq mm |
| 381 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 150 sq mm |
| 382 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 240 sq mm |
| 383 | Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 95 sq mm |
| 384 | Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 120 sq mm |
| 385 | Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 150 sq mm |
| 386 | Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm |
| 387 | Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm |
| 388 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 389 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 390 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 16 sq mm with factory made clamp |
| 391 | Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench160/135 mm or nearest size |
| 392 | Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench175/147 mm or nearest size |
| 393 | Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench200/174 mm or nearest size |
| 394 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 395 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 396 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 397 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 398 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 399 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm) |
| 400 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 401 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) |
| 402 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm) |
| 403 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 404 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 405 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 16 sq mm |
| 406 | Supply and laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 400 sq mm |
| 407 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 400 sq mm |
| 408 | Supply and laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 400 sq mm |
| 409 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) |
| 410 | LT Panels |
| 411 | Supply, Installation, Testing and Commissioning of The Outdoor Lighting Panel, rated 100A TPN (Three Phase and Neutral), wall-mounted with IP54 enclosure (dust protected and splash-proof as per IS/IEC 60529 and aligned with National Electrical Code SP 30:2011 requirements for outdoor installations), shall incorporate a 100A MCCB as incomer for main overcurrent and short-circuit protection, 15 nos (or 16 way) 16A SP (Single Pole) outgoings via MCBs for individual or grouped street light circuits, and dedicated provision for timer and/or photocell control to enable automatic dusk-to-dawn or scheduled operation suitable for controlling up to 15 street lights in compliance with Kerala Electrical Inspectorate guidelines, CEA safety regulations, and relevant BIS standards for low-voltage outdoor distribution systems. |
| 412 | Supply, INstallation, Testing and Commissioning of Office Power Panel to160A TPN, IP54, floor-mounted (or wall-mounted if space-constrained, confirm with engineer), fabricated from 1.5 mm thick CRCA sheet steel throughout (no thinner material permitted anywhere, including doors, covers, gland plates, and partitions), complete with 160A aluminium busbars (E91E grade or better, 160A continuous rating), 1 No. 160A 4P MCCB incomer (36kA Icu/Ics at 415V, thermal-magnetic release), outgoings comprising: 1 Nos. 100A 4P MCCB and 7 Nos. 63A 4P MCCB (min. 16to36kA breaking capacity, thermal magnetic release suitable for general power distribution loads), FRLS PVC insulated stranded copper internal wiring (660/1100V grade, colour-coded, min. 2.5 mm2; for control circuits), detachable 3 mm thick gland plates top and bottom, double compression brass glands supplied loose, continuous GI/Al earth bus (min. 25.6 mm) with all metallic parts earthed via braided straps/copper wires, engraved/anodized SS/aluminium labels (min. 1.6 mm thick, no stickers/painted labels) for panel designation, voltage, rating, feeder names and phase identification, 7-tank pretreatment + powder coating (min. 80 microns DFT, RAL 7035 or approved equivalent), Form 4 separation (IEC 61439), fully type-tested assembly to latest IEC 61439-1 and 2 (submit valid NABL/CPRI/ERDA type test certificates for short-circuit withstand, temperature rise, IP54 and dielectric tests), routine factory tests (insulation resistance, 2.5kV HV for 1 min, functional/continuity), site testing and commissioning (IR &100 MΩ, breaker operation, phasing, earthing continuity), as-built drawings, OEM manual; no deviations allowed without prior written approval to any use of thinner sheet, non-FRLS wiring, undersized busbars, lower-rated breakers or non compliant components shall be rejected/replaced at contractors cost. |
| 413 | Supply, Installation, Testing and Commissioning of Lab Power Panel to 160A TPN, IP54, floor-mounted (or wall-mounted if space-constrained, confirm with engineer), fabricated from 1.5 mm thick CRCA sheet steel throughout (no thinner material permitted anywhere, including doors, covers, gland plates, and partitions), complete with 160A aluminium busbars (E91E grade or better, 160A continuous rating), 1 No. 160A 4P MCCB incomer (36kA Icu/Ics at 415V, thermal-magnetic release), outgoings comprising: 1 Nos. 100A 4P MCCB and 7 Nos. 63A 4P MCCB (min. 16to36kA breaking capacity, thermal magnetic release suitable for general power distribution loads), FRLS PVC insulated stranded copper internal wiring (660/1100V grade, colour-coded, min. 2.5 mm2; for control circuits), detachable 3 mm thick gland plates top and bottom, double compression brass glands supplied loose, continuous GI/Al earth bus (min. 25.6 mm) with all metallic parts earthed via braided straps/copper wires, engraved/anodized SS/aluminium labels (min. 1.6 mm thick, no stickers/painted labels) for panel designation, voltage, rating, feeder names and phase identification, 7-tank pretreatment + powder coating (min. 80 microns DFT, RAL 7035 or approved equivalent), Form 4 separation (IEC 61439), fully type-tested assembly to latest IEC 61439-1 and 2 (submit valid NABL/CPRI/ERDA type test certificates for short-circuit withstand, temperature rise, IP54 and dielectric tests), routine factory tests (insulation resistance, 2.5kV HV for 1 min, functional/continuity), site testing and commissioning (IR &100 MΩ breaker operation, phasing, earthing continuity), as-built drawings, OEM manual; no deviations allowed without prior written approval to any use of thinner sheet, non-FRLS wiring, undersized busbars, lower-rated breakers or non compliant components shall be rejected/replaced at contractors cost. |
| 414 | Supply, Installation, Testing and Commissioning of LT HVAC Panel to 400A TPN, IP54, floor-mounted, fabricated from 1.5 mm thick CRCA sheet steel throughout (no thinner material permitted anywhere), complete with 250A aluminium busbars (E91E grade, 250A continuous rating, current density 1.2 A/mm2), 1 No. 400A 4P MCCB incomer (36kA Icu/Ics at 415V, thermal-magnetic), motor duty rated outgoings comprising Outgoing 5 Nos. 125A 4P MCCB (both with adjustable motor protection releases, min. 25to36kA breaking capacity, Type-2 coordination compliant), FRLS PVC insulated stranded copper internal wiring (660/1100V grade, colour-coded, min. 2.5 mm2; for control), detachable 3 mm thick gland plates top and bottom, double compression brass glands supplied loose, continuous GI/Al earth bus (min. 25;6 mm) with all parts earthed, engraved/anodized SS/aluminium labels (no stickers/paint), 7-tank pretreatment + powder coating (min. 80 microns DFT, RAL 7035), Form 4 separation, fully type tested to IEC 61439 (submit NABL/CPRI/ERDA certificates for short-circuit withstand, temperature rise, IP54 and dielectric tests), routine factory tests (IR, HV 2.5kV/1min, functional), site testing and commissioning (IR;100 M Ω, primary/secondary injection, breaker operation, phasing, earthing continuity), as-built drawings, OEM manual ; no deviations allowed without written approval to any use of thinner sheet, non-FRLS wiring, undersized busbars, non-motor-duty MCCBs or lower ratings shall be rejected/replaced at contractors cost |
| 415 | Transformer |
| 416 | Supply, installation, testing and commissioning of following capacity (continuous loading) 400 kVA , 11/0.433 KV Delta/Star, step down, 3 Phase, 50 Hz, Dyn 11 vector group, Cast Resin / VPI (vacuum pressure impregnated) Dry Type, copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better) AN (air natural) cooled transformer suitable for indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) ( upto 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, insulation class F (minimum), suitable for environment conditions class E4, suitable for fire behaviour class F1,climate class C1, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade with necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers, bus trunking arrangement/MCCB/ACB arrangement on LV side whcihever is as per inspectorate norms, complete with all accessories and safety provisions as per relevant IS Code ,The transformer shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/trip protection, 3 nos. of Polymeric Zinc Oxide surge Arrestors on HV Side. Winding Temperature scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of suitable M.S. Channel with all accessories ,complete in all respects as required at site as per CPWD specifications . Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551/ NEMA Standard. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c) Thermometer pocket with cap; d) Lifting lugs for the complete transformer as well as for core and winding assembly; e) Bi-directional flat rollers (for transformers above 200 kVA); f) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); g) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. for transformers up to 200 kVA; h) Bird guard; i) Jacking pads (for transformer above 1600 kVA); j) Name Rating & Diagram Plate. k) Monogram Plate. i) Additional neutral separately brought out on bushing for earthing. 400 KVA (losses at 50% loading < 1150watt, losses at 100% loading < 3330watt) |
| 417 | HT Panel |
| 418 | Supply, installation, testing and commissioning of Indoor type Single HT VCB panel, floor mounted, fabricated with 2mm thick CRCA sheet suitably reinforced, powder coated, with segregated HT and LT compartment consisting of One no. 11 kV, 800A, TP, 350-500 MVA, VCB, with suitably interlocked earth switch, having horizontal draw out and isolation. The VCB shall be fitted with spring mechanism (manual) for closing, ON, OFF LED /mechanical indication lamp, emergency trip, Microprocessor based Protection relays (3 OC and 1 EF), high speed tripping relay, trip circuit supervision relay, safety shutter etc. The breaker shall be complete with closing coil, tripping coil and shunt trip. Providing necessary power pack (in built) also forms part of the scope. The panel shall be provided with the required no. of auxiliary contacts with 4NO+4NC spare contacts. Components in the panel shall also include, but not limited to the following items. 1 no. Trip neutral close (T-N-C) switch. 1 no. Digital voltmeter scaled 0-15KV with selector switch, 1 no. Digital ammeter scaled 0-100 A with selector switch, 1 set On, Off, Trip, Trip healthy, spring charge indication lamp, 1 set panel earth bus. 1 set Inbuilt Power pack of 110V AC input with DC output for control and indication, 1 set Draw out type 3 limb, 11 kV/110V, 50/100VA, class 0.2, epoxy cast resin potential transformer with necessary HT and LT fuses. 1 set Epoxy resin cast CT with suitable ratio as per demand load, with 15VA, class 0.2S for metering and 15VA class 5P10 for protection, 1 No. 3 phase 4 wire, HT TOD meter, class 0.2S including all accessories like test terminal block, control fuse, control cable etc as per the requirement of KSEB, 1 no Panel heater with a control switch and illumination lamp with door switch. 1 set Test terminal block. 1 set 800A, 26.2kA, TP copper bus having a current density of 1.2A per sqmm duly sleeved with all accessories and insulators complete as required. Necessary surge protectors as per requirement of KSEB shall be provided. Required Danger boards, signages, lettering etc. The panel shall be subjected to all routine tests as per IS/IEC standards. Type test certificate of identical panel shall be submitted. Seperate Metering Panel shall be incorporated for metering facility. The VCB and panel shall be provided with all necessary standard safety feature as per IS and door interlocks such as breaker cannot be drawn out when breaker is in ON position and similarly breaker cannot be closed unless it is fully in drawn in condition. In addition to the above, 11kV HT panel shall be with all requirements as per the guidelines by Local E.B authorities, Central Electricity Authority/Electrical inspectorate |
| 419 | Supply Installation Testing and Commissioning of of CTC 12 kV, 630 A, SF6 Ring Main Unit complete ( Extensible / Outdoor) ( 2 Isolators + 1 Breaker ) with Motorized + Battery Charger (cost should include Factory test reports, loading Unloading, local Union charges, Excavation and construction of RCC Pedestal (supply of steel and concrete included) for RMU Installation, Earth Pit, Earthing strips and included in scope. Testing fee to be paid by the Contractor shall be included. All work as per KSEB specification and standards Installation and commissioning. If Feeder Remote Terminal Unit (FRTU) is required by KSEB, this shall also be provided, and the price shall be inclusive of the same. Make: Schneider/ABB/Lucy or equivalent |
| 420 | MSB and APFC Panel |
| 421 | Design, manufacture, supply, erection, testing and commissioning of floor-mounted, dust and vermin proof, free standing cubicle type Main Switch Board (MSB) suitable for 415/433V, 3 phase, 4 wire, 50 Hz system, designed for a fault level of minimum 50 kA for 1 sec, conforming to IS 8623 (with latest amendments) / IS 61439-1 & 2 and relevant IEC standards, type tested assembly (TTA) from OEM with routine test certificates. The panel shall be Form-4b, fully compartmentalised, front and rear accessible, fabricated using minimum 2.0 mm thick CRCA sheet steel for doors and covers and 2.5 mm thick for load bearing members, totally enclosed, rigid welded construction, with gland plate of minimum 3 mm thickness. Angles/flats/slotted angles shall not be used. Panel shall be powder coated after 7-tank pretreatment process with minimum 60 - 80 micron epoxy polyester coating. Degree of protection shall be minimum IP 54. The panel shall have adequately sized aluminium TPN busbars of 630A rating (minimum 50 kA for 1 sec), with colour coded heat shrink sleeves, supported on SMC/DMC supports with proper phase segregation and short circuit withstand capability. Neutral bus shall be 100% rated and earth bus shall run throughout the panel. Busbars shall be sized for temperature rise as per standards and not merely current rating. Doors shall be earthed with braided copper conductor (minimum 4 sqmm). Adequate space shall be provided for termination of all incoming and outgoing cables with removable gland plates and shrouding. The panel shall consist of one no. 630A, 4P, 50kA MCCB incomer (Ics = 100% Icu) with adjustable overload (0.4 to 1.0 In), short circuit (1.5 to 8 Ir), instantaneous and ground fault protection, complete with extended rotary handle, spreader links, phase barriers and interlocks; one no. 630A AMF controller; one no. 630A 4P isolator; two nos. 630A 4P electrically operated contactors with mechanical interlocking for EB?DG changeover; 630/5A CTs (Class 1, 15VA) for metering and APFC; earth fault relay; AMF relay; two sets RYB LED indication lamps with control MCB/fuse; two nos. multifunction digital meters (accuracy class 1) with CTs and control protection for measuring V, I, F, PF, kW, kVA, kWh, kVAh, run hours etc. Complete necessary interlocking to prevent simultaneous closing of EB and DG supply (electrical and mechanical). Outgoing feeders shall comprise: 2 nos. 400A, 4P, 25kA MCCBs (Ics = 100% Icu), thermal magnetic type with adjustable overload (0.8 to 1.0 In) and short circuit In); 3 nos. 250A, 4P, 25kA MCCBs (Ics = 100% Icu), thermal magnetic type with adjustable overload (0.8 to 1.0 In) and short circuit In); 2 nos. 160A, 4P, 25kA MCCBs; 3 nos. 100A, 4P, 25kA MCCBs; all complete with extended rotary handles, spreader terminals, phase barriers, shrouding and proper cable termination facilities. All breakers shall be from same OEM as panel manufacturer to ensure coordination and discrimination. Panel shall include necessary wiring with FRLS copper control wiring, terminal blocks, ferruling, identification labels, danger boards, mimic diagram, earthing terminals, and space for 20% future expansion. The entire assembly shall be complete in all respects including internal wiring, busbar interconnections, supports, fasteners, testing, and commissioning at site, ready for operation |
| 422 | Automatic Power Factor Correction (APFC) System - Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5deg C to +40deg C, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework and covers, 3 mm thick for gland plate i/c cleaning and finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens Gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5 deg C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 and 2) APFC Panel shall be in compliance with IS :16636 and CPWD Specifications etc. as per below details. (A) IncomersSuitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B- LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating. (B) Instruments and Indications i) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100 KVAR and above) with Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CTs accuracy class 1, 15VA at incomer of PCC Panel for APFC relay. ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode. iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V and I, Frequency. iv) Suitable rating control transformer shall be provided for control and indication circuit. v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCBs. vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated multi stranded copper control wire. (C) Bus Bars 1.3 Amp per Sq.mm,TPN, Electrolytic grade Aluminium bus bar of capacity 1.25 times of incomer rating as per CPWD specification. (D) Outgoings (APFC Section) Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty contactor,the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections inter connections etc. and other features as per CPWD Specifications and relevant IS Code having following:(i) Capacitor bank ratings and stages shall be as per the technical specifications sheet of NIT.(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism.(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts. (iv) 14% Detuned Reactor of class H insulation and 150% linearity in series with Capacitor. (Note: Technical specifications sheet for selection of the capacitors combinations shall be provided by the NIT Approving Authority with due consideration of number of capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5 KVAR, 10 KVAR. for smooth correction). 150 KVAR |
| 423 | DG and AMF Panel |
| 424 | Supplying, Installation, Testing & Commissioning of Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. |
| 425 | (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9.Main supply failure monitor 10.Supply failure timer 11.Restoration timer 12.Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14.ON/OFF/Control circuit switch with indicator 15.Audio/Video annunciation for (i)High water temperature (ii)Low lubricating oil pressure (iii)Engine over speed (iv)Engine fails to start (v)Full load/maximum load warning 16.Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. 400 kVA DG Set |
| 426 | HT Cable |
| 427 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm |
| 428 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm |
| 429 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm |
| 430 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm |
| 431 | Cable Route Marker |
| 432 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 433 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 434 | CCTV System |
| 435 | Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent |
| 436 | Camera 2MP Bullet/Dome Camera: Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet/Dome Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt Smart IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range: WDR (120db or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable(Main 1080)@25/30 fps stream: Sub 2MP (1920 ×streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering,HTTPS, trusted upgrade, trusted boot. 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE, 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body, 19) Operating Condition:- Ambient Temperature:- ()05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS. 2 MP @ 25/30fps@1080P (1920×1080) Outdoor Dome/Bullet Camera with 2.8/ 3.6mm fixed lens |
| 437 | Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete |
| 438 | Supply Installation Testing and Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19" chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. |
| 439 | Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. |
| 440 | Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent |
| 441 | Supply and Installation of LED Color display of minimum 43 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. |
| 442 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 443 | 32 channel NVR : Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video compressions : H.265 or better, H.264, MJPEG. 3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions. 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 8 SATA Slotswith 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA 9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email and SMS Altert options: Option for SMS/Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web and Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5degreeC to 50degreeC, humidity 90% (max) (non-condensing) 16) The VMS application shall support all the features and functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF 22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page |
| 444 | 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence: NVR should have built-in AI :-- 2 Channel face detection and recognition, Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries and regions and state to each face image. 27) Face and Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 34) Analytics by NVR: Perimeter protection and face recognation. 32 Channel Network Video Recorder (NVR) having display split : Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 445 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 8 TB |
| 446 | Network Infrastructure |
| 447 | Supply and Installation of required cable managers and accessories complete |
| 448 | Supply and Installation of enterprise grade 24U floor standing Rack including power distribution box, doors, rails, accessories complete. Make:Rittal/Valrac |
| 449 | Supply and Installation of enterprise grade 42U floor standing Rack including power distribution box, doors, rails, accessories complete. Make: Rittal/Valrack |
| 450 | Supply and Installation of Fiber Patch Cord LC-LC SM. |
| 451 | Supply and Installation of CAT6 Patch Cord 1m. D-Link/Molex/Finolex |
| 452 | Supply and Installation of 24 Port CAT6 Patch Panel |
| 453 | Supply and installation of 12F/24F LIU with Splicing |
| 454 | Supply, Installation, Testing and Commissioning of Next Gen Firewall, 1 Gbps Throughput, VLAN Support, VPN, IPS, Web Filtering, 200 Users Capacity having perpetual license. Make: CISCO/Fortigate/Aruba/Ruckus/Commscope |
| 455 | Supply, Installation, Testing and Commissioning of 10G SFP+ Single Mode Transceiver, LC Connector, 10km Range. Compatible OEM |
| 456 | Supply, Installation, Testing and Commissioning of Managed Layer-2 Access Switch, 48×1G RJ45 PoE+, 4×SFP Uplink, PoE Budget 370W, VLAN, STP/RSTP, QoS, SNMP, Rack Mountable, having perpetual license. Make: CISCO/Fortigate/Aruba/Ruckus/Commscope |
| 457 | Supply, Installation, Testing and Commissioning of Layer-3 Core Switch, 24×1G RJ45, 4×10G SFP+, VLAN (4096), Static Routing, OSPF, ACL, QoS, SNMP, CLI, Switching Capacity 120 Gbps, Rack Mountable having perpetual license. Make: CISCO/Fortigate/Aruba/Ruckus/Commscope. Make: CISCO/Fortigate/Aruba/Ruckus/Commscope |
| 458 | Supply, termination, and installation of RJ45 connectors for data or voice network, including testing and labeling. |
| 459 | Supplying and fixing RJ45 Outlet including cover plate, Keystone Jack and Gang box supporting, connection etc. as required |
| 460 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 2 run of Cable |
| 461 | Supply, Installation, Testing and Commissioning of Indoor WiFi 6 Access Point, Dual Band (2.4GHz and 5GHz), 2;2 or 4;4 MIMO, MU-MIMO, OFDMA, Gigabit Ethernet Port, 802.3af/at PoE Powered, Ceiling Mountable, VLAN and WPA3 Support, Centralized or Standalone Management with perpetual license. Make: CISCO/Fortinet/Aruba/Commscope |
| 462 | VRF System |
| 463 | Supply of all materials and Installation of drain pipe between Indoor unit and drain point including U Trap. (slope of pipe is 1:100) Drain pipe for condensate drain to the nearest drain point with 25mm uPVC pipe insulated using 9mm thick Nitrile Rubber tubing as per Client/Engineers instruction. |
| 464 | Additional gas charging |
| 465 | Supply and Installation of PVC Insulated flexible control cable with saddles / supportes and PVC conduits to connect outdoor unit with Indoor unit (as per manaufacturars standard) |
| 466 | Design, Supplying, Installation, Testing and Commissioning of Modular Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50degreeC ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 deg C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity < 40 kWr ISEER 6.4, Capacity >= 40 and <70 ISEER 6.5, Capacity >= 70 ISEER 6.6 for ECSBC+ Building) For Cooling or Heating or Both. The no of VRF outdoor units shall be designed as per requirment |
| 467 | 3.6 TR 4 way Cassette Type Indoor VRF unit: Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a signal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. Thecooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of Outdoor). 3.6TR |
| 468 | 2.0 TR 4 way Cassette Type Indoor VRF unit: Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a signal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of Outdoor). 2.0TR |
| 469 | 1.6 TR 4 way Cassette Type Indoor VRF unit: Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a signal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of Outdoor). 1.6 TR |
| 470 | 1 TR 4 way Cassette Type Indoor VRF unit: Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a signal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of Outdoor). 1 TR |
| 471 | Copper piping 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm : Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 472 | Copper piping 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm : Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 473 | Copper piping 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm : Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 474 | Copper piping 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm : Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 475 | Copper piping 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm : Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 476 | Copper piping 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm : Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 477 | Copper piping 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm : Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 478 | Copper piping 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm : Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 479 | Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs. Outdoor Multijoint |
| 480 | Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs. Indoor Unit |
| 481 | 2 TR Low static ductable units : Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted low static ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) Low static ductable units (minimum 19 to 29 pascal external static pressure) |
| 482 | Supplying and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound in confirmation to SMACNA/IS and as per specifications complete etc. as required |
| 483 | Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 484 | Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume Controldampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 485 | Site fabricated Volume Control Dampers : Supply, installation, testing and commissioning of opposed/parallel blade type Volume Control Dampers fabricated from minimum 0.63 mm thick galvanized steel sheet matching the duct construction specification, complete with casing, aerofoil blades, operating linkage, shaft, bushes, locking quadrant, lever arrangement, gaskets, supports, nut bolts and all necessary accessories as required. Dampers shall be suitable for smooth airflow regulation with low leakage characteristics and shall be properly sealed, aligned and rigidly supported complete in all respects as per approved HVAC drawings and specifications. |
| 486 | Site fabricated GSS Thickness 0.63 mm sheet: Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. |
| 487 | Exhaust System for 3000 CFM AHU : Supply, installation, testing and commissioning of complete exhaust air system for AHU area of minimum 3000 CFM capacity comprising factory fabricated/site integrated exhaust arrangement including exhaust fan/blower assembly with dynamically balanced impeller, TEFC motor, vibration isolation arrangement, necessary supports, mounting frame, flexible connections, GSS ducting fabricated from minimum 0.63 mm thick galvanized steel sheet, dampers, grilles, hangers, gaskets, insulation wherever required, control wiring and all associated accessories complete as required for proper operation. The system shall be suitable for continuous low noise operation, proper air extraction and ventilation, complete with testing, balancing and commissioning in accordance with approved HVAC drawings and specifications. |
| 488 | 3000 CFM AHU : Supplying, Installation, testing and commissioning of Factory built ceiling suspended chilled water double skin type horizontal/vertical air handling units of following capacity, made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with Polyurethane Foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with Totally Enclosed Fan Cooled (TEFC) drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for Variable Frequency Drive (VFD) applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometres (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration Isolation arrangement, noise level shall not exceed 70 dB. AHU shall be AHRI/Eurovent certified, fan shall be AMCA certified etc. Complete as per CPWD specification/drawings and as directed by Engineer-in-Charge. (Total static pressure considered is 50 mm WG). 3000 CFM |
| 489 | Conference System |
| 490 | Supply and Installation of fixed projector screen having Screen Size: 15 x 8.5 Feet, Material : PVC, Aspect ratio :16:9, Support : Active 3D,4K. Frame: Fixed iron frame with 40mm galvanized square pipe etc complete. |
| 491 | Supply, Installation of 4K Projector, Dual Light, ISA 3.0, 2300 ISO Lumens, Optical Zoom - Projector with WiFi and bluetooth with accessories. Make: Sony/EPSON/BenQ |
| 492 | Supplying and fixing fibre optical HDMI cable of 15 mtr length, Data Transfer Rate:10.2 Gigabits Per Second, Support video Resalution: 4K@30fps, 1080p @ 60 fps etc complete |
| 493 | Supply, Installation, Testing and Commissioning of minimum 98 inch LED display, premium large-format 4K Smart TV not less than 98 inch with direct backlight technology (Mini-LED/Neo QLED/QNED), 3840×2160 resolution, high dynamic range support (including Dolby Vision or HDR10+), advanced image processing for natural color and motion clarity, wide viewing angles, and a robust smart platform; the unit shall include integrated high-quality speakers with support for immersive audio formats (e.g., Dolby Atmos), multiple HDMI 2.1/2.0 and USB inputs, network connectivity (Wi-Fi/LAN), and low latency for AV integration. The display shall be suitable for conference, presentation, and multimedia applications, with uniform brightness appropriate for ambient light conditions, a user-friendly OS (Google TV, webOS, or Tizen), and 3 year warranty support from the original manufacturer, each providing comparable picture quality, durability, and connectivity for shared seminar halls. Make: (Sony BRAVIA) or (LG evo AI QNED86 253 cm or Samsung QN80F Neo QLED 4K) |
| 494 | Supply, installation, testing & commissioning (SITC) of 2 Nos professional wireless microphone systems comprising dual-channel wireless receiver(s) and compatible handheld / bodypack transmitters as required, suitable for speech reinforcement, conferencing, and training applications. System shall operate in UHF digital or analog professional frequency band with stable RF performance, automatic frequency scanning and synchronization, minimum operating range of 30 meters (line of sight), low latency, and high signal-to-noise ratio. The receiver shall be rack-mountable, with balanced XLR outputs and unbalanced outputs, RF and audio level indicators, and secure frequency locking to prevent interference. The microphones shall feature high-quality components for clear voice reproduction, with minimum 5 hours battery operation per charge/use. The system shall include antennas, power adapters, rack-mount kit, audio interconnection cables, and integration with the DSP/amplification system. Make: Shure/Sennheiser/Sony |
| 495 | Supply, installation, testing & commissioning (SITC) of 2 Nos professional wired microphones suitable for speech, presentation, and conferencing applications. Microphones shall be dynamic or condenser type (as per application), with cardioid or super-cardioid polar pattern for effective feedback rejection and clear voice reproduction, frequency response optimized for speech intelligibility, and low handling noise. Each microphone shall include appropriate desktop stand / gooseneck base (if required), shock mount (where applicable), minimum 5–10 meter professional-grade balanced XLR cable, and necessary connectors with minimum 3 year onsite warranty. The system shall be fully compatible with the installed DSP/mixer and amplification system, with proper impedance matching and phantom power provision. Make: Shure/Sennheiser/Sony |
| 496 | Supply, Installation, Testing and Commissioning) of commercial-grade flush mounted in-ceiling loudspeakers suitable for speech reinforcement, conferencing, and background audio applications. Each speaker shall be passive type, wide dispersion (minimum 120degree nominal coverage), frequency response suitable for clear voice reproduction (approximately 80 Hzto18 kHz or better), and shall support 70V/100V line operation with multiple transformer taps up to minimum 16W and low-impedance bypass option. The system shall include necessary back cans, grilles, mounting accessories, safety supports, structured cabling, termination, integration with amplifier/DSP system, equalization, polarity testing, commissioning, and handover. Installation shall ensure uniform SPL distribution and high speech intelligibility across the designated coverage area with minimum 3-year onsite warranty. Make: JBL Control 14CT/Bose Freespace FS2C |
| 497 | Supply, installation, testing and commissioning of complete structured cabling infrastructure for the integrated Audio-Visual system, including supply and laying of high-quality HDMI (4K/HDBaseT where required), shielded Cat6/Cat6A data cables, balanced audio cables (2C/4C shielded), speaker cables (FRLS copper, appropriate gauge), USB extension cables, control cables, fiber optic cables (if required), and power cables (FRLS copper) as per system design. All cables shall be of reputed make, fire-retardant low-smoke (FRLS/LSZH where applicable), properly ferruled, labeled at both ends, and terminated using certified connectors and patch panels. Installation shall be through PVC conduits / GI trunking / cable trays with proper segregation of power and signal lines to avoid interference. Scope includes dressing, lacing, heat-shrink labeling, earthing, continuity testing, certification of data lines (Fluke test for Cat6/Cat6A), signal verification for AV lines, as-built documentation, and handover. Contractor shall ensure compliance with relevant IS/IEC standards, protection against EMI/RFI, and provision of service loops for maintenance. Work shall be executed in a neat, professional manner ensuring long-term reliability, system performance, and protection of client infrastructure with minimum 3-year onsite warranty. |
| 498 | Supply, installation, testing and commissioning of a professional audio processing and control engine for conferencing, room audio, and hybrid AV applications. The system shall include a compact, networked DSP processing unit with built-in acoustic echo cancellation (AEC), USB audio interfacing for soft codecs (minimum 8;8), balanced analog audio I/O, and support for networked audio transport (such as AES67/Dante/Q-LAN/AVB). The processor shall provide flexible routing, mixing, delay, EQ, automatic mic processing and system control logic for camera switching and conferencing workflows. The unit shall support distributed audio networking, integration with sip/soft codecs, and scalable expansion with additional I/O if required with minimum 3-year onsite warranty. . Make: Biamp TesiraFORTE/QSC Q-SYS Flex 8 |
| 499 | Supply, installation, testing and commissioning of rack-mount professional 100V line power amplifier, suitable for distributed ceiling loudspeaker systems. The amplifier shall provide minimum 300-500W continuous output power in 70V/100V constant voltage mode, with low distortion (<1% THD), high signal-to-noise ratio (>90 dB), balanced line inputs, thermal and short-circuit protection, and front panel level control. The amplifier shall be rack-mountable with forced or convection cooling and suitable for speech reinforcement and conferencing environments. Make: Harman / QSC / Yamaha |
| 500 | Supply, installation, testing, and commissioning of a floor-mounted digital multimedia podium with heavy-duty steel/aluminium construction and powder coated/brushed finish, mounted on four lockable caster wheels, with hinged lockable top and concealed cable management. Podium shall be equipped with minimum 19–22 capacitive touch screen display (minimum 1440×900 resolution, 300 cd/m² brightness, 1000:1 contrast ratio, wide viewing angle), integrated laptop interface module providing minimum 1×HDMI, 1×VGA, 2×USB, 1×RJ45 LAN, 1×Audio-in, 1×Audio-out and 1×230V AC power socket. Unit shall include one gooseneck microphone with ON/OFF control, built-in audio routing/amplification for external PA connection, internal power distribution unit rated minimum 3 kW with surge protection, 110–240V AC, 50/60Hz input, and provision for HDMI/VGA/audio pass through at rear/bottom panel. Podium shall have proper ventilation, lockable access panels, ergonomic writing surface, and internal wiring complying with relevant IS/IEC safety standards. Complete system to be supplied with all interconnections, accessories, installation, testing and commissioning, with minimum 3-year onsite warranty. Make: EISTouch ET-501XA/ PeopleLink ePodium Elite |
| 501 | IP PBX System |
| 502 | Supply and Installation of Network switch of 48 port suitable for IP PBX system |
| 503 | Supply and Installation of Business IP Phones. Make: Grandstream/Matrix/BPL |
| 504 | Supply, Installation, Testing and Commissioning of Core IP PBX Appliance suitable for minimum 300 users, minimum 300 concurrent calls. Make: Grandstream/Matrix/BPL |
| 505 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 1 run of Cable |
| 506 | Dismantling Works |
| 507 | Dismantling of existing internal electrical installations including point wiring, circuit wiring, sub-main wiring, power wiring, control wiring, PVC/metal conduits, casing and capping, batten wiring, switch boxes (flush/surface), modular/non-modular switches, socket outlets, fan regulators, ceiling roses, junction boxes, light fittings, fans, call bells, exhaust fans, MCB/isolator, SPN/TPN distribution boards with incoming and outgoing connections, earthing connections and all other associated accessories complete, after proper isolation of supply, carefully removing and stacking serviceable materials as directed and making good damages to the existing building surface, as required. |
| 508 | Dismantling of existing surface/ ceiling fixtures as per the direction of Engineer in charge |
| 509 | Dismantling of existing LT power/control cable of any core and size laid in existing cable trench, including careful removal of clamps, saddles, tags, cable ties, and other supporting accessories without causing damage to the cable or surrounding services. The work shall also include identification and labeling of reusable cables, coiling and stacking them at the designated location as directed by the Engineer-in-Charge. Unserviceable cable lengths and accessories shall be segregated and disposed of as per site instructions. All work shall be carried out manually or with appropriate tools ensuring safety and without disturbing other live cables or installations in the trench. The rate shall include all labour, tools, handling, and shifting of materials to the site store or disposal point. |
| 510 | Dismantling of the existing earthing system including excavation and removal of earth electrode (pipe/plate), charcoal, salt layers, inspection chamber, funnel with cover, and connecting earth strips/wires of any size and type (GI/CI/Copper/Aluminium), complete in all respects. This includes disconnecting the earth strips from equipment or main earthing network, carefully removing and stacking serviceable materials as directed, carting away unserviceable materials and debris from the site, and backfilling the excavated pits with excavated soil. The work shall be carried out in a neat and safe manner ensuring no damage to adjacent cables, equipment or structures, all as per the instructions of the Engineer-in-Charge. |
| 511 | First Aid Hose Reel & Down Comer system |
| 512 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.( for 30 m standared length) |
| 513 | Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal or stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel |
| 514 | Supplying and fixing single headed external yard hydrant valve with one no: 63 mm dia instantaneous FM Gun metal or stainless steel coupling and cast iron wheel, ISI marked ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel |
| 515 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure of the outlet to the level of 3.5kg/cm2 complete as required. |
| 516 | Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless steel (Grade 304) |
| 517 | Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304) |
| 518 | Supplying and fixing fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia M.S. Pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S.Pipe |
| 519 | supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required. |
| 520 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:25 mm dia |
| 521 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required: 80mm dia |
| 522 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia |
| 523 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers, ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 524 | Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia |
| 525 | Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.100 mm dia |
| 526 | Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock & key. |
| 527 | Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 9890, at required locations. 20 mm dia Make : Kartar/Audco/Zoloto |
| 528 | Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 9890, at required locations. 25 mm dia Make : Kartar/Audco/Zoloto |
| 529 | Supply and fixing of Air release valve SS body of 25 mm dia. |
| 530 | Supply and fixing of pressure guage, 4\\" dial, 0 - 200 psi range 3/8\\" BSP weather proof with stainless steel internals, siphon tube including fittings. |
| 531 | Providing and fixing of pressure switch in MS pipeline including connection etc as required: |
| 532 | Terrace Pump & panel |
| 533 | Supplying, installation, testing and commissioning of electric driven 900 lpm at 35m Head |
| 534 | Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm |
| 535 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 536 | Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm |
| 537 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 538 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.4 X 10 sq. mm |
| 539 | Supplying, Installation, Testing and Commissioning of Starter Panel, Fabricated for capable of Operation of 900LPM Terrace Pump or capable of start up to 12.5 HP pump and having provision for automatic starting by pressure switches, control mounting shall include necessary lamps indications, selector switch, auto/manual selector switch, voltmeter with selector switch controlling push button etc. The panel shall be duly painted with protective anticorrosive and shall be wall mounted type including all accessories. |
| 540 | Automatic Fire Detection & Alarm System |
| 541 | Supply, Installation, Testing & Commissioning of min 4 loops Addressable Fire Alarm Panel having a capacity of min 198 addressable devices per loop, with multi colour touch display, operates on 230V AC/ 24V DC PSU with battery for 24hour normal operation back-up, UL listed. The panel material should be powder coated MS in approved colour. |
| 542 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 543 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 544 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 545 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 546 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 547 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 548 | CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 549 | Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm |
| 550 | Supply and fixing 25 mm PVC casing capping as required. |
| 551 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of response indicator on surface/ recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 552 | Fire extinguishers & signages |
| 553 | Supply & installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent |
| 554 | Supply & installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent. |
| 555 | Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity - 5 kg Make : SAFEX/MINIMAX/CEASEFIRE or equivalent |
| 556 | Supply & Installation of photoluminescent signage in rigid sheet of standard size.(FIRE EXTINGUISHER/FIRE LIFT/STAIR CASE/ FIRE STAIR CASE/FIRE DUCT/ NO SMOKING/ FIRE ALARM CALL POINT/EXIT/FIRE EXIST) |
| 557 | Supplying & fixing in position \\"Assembly Point\\" sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building.\\"Assembly Point\\" |
| 558 | Supply and Fixing of Floor Evacuation Plan printed on high-quality acrylic sheet with a minimum thickness of 3mm, complying with releavant standards. The evacuation plan shall be of suitable size, with clear, color-coded floor layout, escape routes, emergency exits, firefighting equipment locations (fire extinguishers, hydrants, alarms), and assembly points as per approved fire safety guidelines. The plan shall have photo-luminescent/glow-in-the-dark features for visibility in low-light conditions. Fixing shall be done at eye level (1.5m from the floor) using stainless steel screws with nylon plugs or industrial-grade adhesive for firm mounting on walls. |
| 559 | General works |
| 560 | Preparation of all drawings, obtaining permits, approvals and No Objection Certificates (NOC) (initial & final) after submission to Fire Department. (Statutory fee on actual basis will be paid extra on submission of original receipt) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail