| 1 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets, bell push, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match/finish new surface as the existing surface either by using same colour distemper, Putti or white/colour wash complete all as specified and directed. |
| 2 | M&L for concealed point wiring for one light/Fan/Bell point controlled by one switch 6/5 Amp one way single pole.in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with earth dolly and Bakelite laminated sheet ISI marked for fixing of switches/sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching/finishing of new surfaces either by means of plaster of peris/Putti or distemper/colour wash with same existing colour surfaces complete all as specified and directed. |
| 3 | All as per srl item No 02 above but one 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 4 | All as per srl item No 02 above but one 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 5 | All as per srl item No 02 above but one 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horizontal plane. |
| 6 | All as per srl item No 02 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 7 | All as per srl item No 02 above but for one 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horizontal plane. |
| 8 | M&L for concealed point wiring for one light/Fan/Bell point controlled by one switch 6/5 Amp one way single pole in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/fittings such as junction boxes, bends, tee, elbow etc alongwith modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching/finishing of new surfaces either by means of plaster of peris/Putti or distemper/colour wash with same existing colour surfaces complete all as specified and directed. |
| 9 | All as per srl item No 08 above but one 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 10 | All as per srl item No 08 above but one 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 11 | All as per srl item No 08 above but one 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horizontal plane. |
| 12 | All as per srl item No 08 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 13 | All as per srl item No 08 above but for one 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horizontal plane. |
| 14 | M&L for Surface point wiring for one light/Fan/Bell point controlled by one switch 6/5 Amp one way single poleon wall/ceilng with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia/PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with earth dolly and Bakelite laminated sheet ISI marked for fixing of switches/sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching/finishing of new surfaces either by means of plaster of peris/Putti or distemper/colour wash with same existing colour surfaces complete all as specified and directed. |
| 15 | All as per srl item No 14 above but one 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 16 | All as per srl item No 14 above but one 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 17 | All as per srl item No 14 above but one 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horizontal plane. |
| 18 | All as per srl item No 14 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 19 | All as per srl item No 14 above but for one 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horizontal plane. |
| 20 | M&L for Surface point wiring for one light/Fan/Bell point controlled by one switch 6/5 Amp one way single pole on wall/Ceiling with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia/PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/fittings such as junction boxes, bends, tee, elbow etc alongwith required size modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching/finishing of new surfaces either by means of plaster of peris/Putti or distemper/colour wash with same existing colour surfaces complete all as specified and directed. |
| 21 | All as per srl item No 20 above but one 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 22 | All as per srl item No 20 above but one 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 23 | All as per srl item No 20 above but one 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horizontal plane. |
| 24 | All as per srl item No 20 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 25 | All as per srl item No 20 above but for one 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horizontal plane. |
| 26 | Taking down old unserviceable/deteriorated point wiring aluminium/copper (excluding PVC conduit/casing & caping & GI/PVC switch box any type and size) from existing place for light light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets, bell push, ceiling rose, pendants, Holders sunken box, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match/finish new surface as the existing surface either by using same colour distemper, Putti or white/colour wash complete all as specified and directed. |
| 27 | M&L for drawing the wire in existing conduit steel/PVC casing & caping any type for one light/Fan/Bell point controlled by one switch 6/5 Amp one way single pole.and size complete with point wiring with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in old existing sunken terminal boxes pressed MS/GI/PVC boxes of any type and size for mounting switch, socket etc along with screw and cup washers with all accessories and making good to disturbed surface with cement mortar and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed. |
| 28 | All as per srl item No 27 above but for one 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 29 | All as per srl item No 27 above but for one 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 30 | All as per srl item No 27 above but for one 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horizontal plane. |
| 31 | All as per srl item No 27 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 32 | All as per srl item No 27 above but for one 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horizontal plane. |
| 33 | S&F in repair modular switch 6A SP one - way 230V white ivory finish complete all as specified and directed. |
| 34 | S&F in repair modular switch 16A SP one - way 230V white ivory finish complete all as specified and directed. |
| 35 | S&F in repair modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified and directed. |
| 36 | S&F in repair modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified and directed. |
| 37 | S&F in repair modular type stepped electronic fan regulator complete all as specified & directed. |
| 38 | M&L for replacement of modular bell push, single pole, one way, 6 Amp suitable for 1 module complete all as specified and directed. |
| 39 | S&F in repair modular switch 6A SP Two- way 230V white ivory finish complete all as specified and directed. |
| 40 | M&L for replacement of modular white cover plate with frame and flush box for 1 to 4 Module complete all as specified and directed. |
| 41 | M&L for replacement of modular white cover plate with frame and flush box for 6 to 12 module complete all as specified and directed. |
| 42 | S&F in replacement medium step type fan regulator 80 Watt, 240 Volt AC, socket size, medium step\\" ISI marked complete all as specified and directed. |
| 43 | S&F in replacement switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and directed. |
| 44 | S&F in replacement switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and directed. |
| 45 | S&F in replacement socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and directed. |
| 46 | S&F in replacement socket outlet, 2 in 1, 3/5 pin 6/16 Amp, piano flush type complete all as specified and directed. |
| 47 | S&F in replacement bell push 5/6 Amps SP flush type complete all as specified and directed. |
| 48 | S&F in replacement Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and directed. |
| 49 | S&F in replacement Angle lamp/batten holder fixed on wall/ceiling complete all as specified and directed. |
| 50 | S&F in replacement ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and directed. |
| 51 | S&F in in repair Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed. |
| 52 | M&L in repair for Sub main wiring complete with two single core 2.5 sqmm, 1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 2.5 sqmm in and including PVC conduit/Casing caping incl accessories complete all as specified and directed. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length.) |
| 53 | M&L in repair for Sub main wiring complete with two single core 4 sqmm, 1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 4 sqmm in and including PVC conduit/casing caping incl accessories complete all as specified and directed. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length.) |
| 54 | M&L in repair for Sub main wiring complete with Two single core 6 sqmm and one core of 6 sqmm earth wire, 1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC Conduit/casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims.(ii) 3 runs of 6 Sqmm conductor and one run of PVC conduig/casing caping shall be measured as one unit length.) |
| 55 | S&F in replacement of MCCB 63 Amps TP/FP16 KA with fixed thermal magnetic release frame F2 optim 1.0, 4 pole complete all as specified and directed. |
| 56 | S&F in replacement of 3 Pin Plug Top 16A, White/Black 240V/3 Pin Top complete all as spd and directed. |
| 57 | Material and labour for sub main wiring with two single core PVC FRLS insulated unsheathed copper conductor cable 1.5 sqmm drawing in and including PVC Casing/casing of suitable size on wall/surface on ceiling with one additional PVC wire of copper conductor of 1.5 sqmm for earth continuity conductor complete all as specified and directed. |
| 58 | S&F in repair LED Tube light fittings 18/20 W White/warm white Surface and wall mounted LED batten, 6500K colour temparature. Soft & uniform light, instant start electronic driver efficiency >85%, complete including all accessories internally pre-wired in and including connecting up with twisted flexible copper conductor cable of suitable size from ceiling rose to connector complete all as specified and directed. |
| 59 | Disconnecting and taking down and opening the ceiling fan of size 1200/1400 mm sweep/Exhaust fan up to 300 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution and replacing the split pin and unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, canopy, etc., assembling Ceiling fan and refixing in the original place or as per direction duly connection and testing complete along with replacement of Ball bearing, bushes, condenser, fan clamp with u clamp, rubber reel split pin, fan hook all as per existing size and shape complete with synthetic enamel paint by spray painting complete all as specified and directed. |
| 60 | S&F in replacement of surface/ceiling mounted with in-built driver, power factor > .9 operating voltage 230 V, round/square/rectangular shape 6 to 9 LED downlighter of white/neutral white/warm white color temperature, of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed. |
| 61 | Material and labour for disconnecting from the electric mains and Taking down opening and inspection of storage type water heater of size 25 ltrs/50 Ltrs capacity and descaling with dilute hydrochloric acid, checking for water tightness of the inner tank, cable continuity, thermostat of setting at 70 degree C checking fusible plug, base assembly, stop cock including replacement of indicator lamp, rubber PVC gasket washers reassembling, refixing and reconnection the electric connections at old place and replacing unserviceable bolts and nuts, cementing work including hydraulic pressure testing with hard operated hydraulic pump complete after repair including spray painting of one coat with paint of approved make after preparation of surface complete all as specified and directed.Note : (a) Labour charges for replacing the unsv spares, disconnection and reconnection of water and electric connections and items like heating element, Indicator lamps, thermostat, fusible plug, safety valve and fastnut any type and size shall be deemed to be included in unit rate quoted for this items . |
| 62 | S&F in repairs capacitor 2.5/3.15 MFD 230 Volt, AC supply complete all as specified and directed. |
| 63 | S&F in repair LED street/Building light with pressure die-cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP 65 protection 30 watt complete with all accessories and wall mounting bracket of suitable size including clamps, nut bolts etc. prewired 3 core flexible wire complete all as specified and directed. |
| 64 | S&F in replacement of LED light fitting surface and wall mounted LED batten with PVC housing & integrated electronic sensor complete in all respect of 10W cap complete all as specified and directed. |
| 65 | S&F in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way complete all as specified and directed. |
| 66 | S&F in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way complete all as specified and directed. |
| 67 | S&F in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way complete all as specified and directed. |
| 68 | S&F in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 2 way complete all as specified and directed. |
| 69 | S&F in replacement of MCCB 100 Amps TP/FP16 KA with fixed thermal magnetic release frame F2 optim 1.0, 4 pole all as specified and directed. |
| 70 | S&F in replacement MCB SPN, 5 to 40 Amps 240 volts, AC, 10 KA breaking capacity 'C' Series, complete all as specified and directed. |
| 71 | S&F in replacement MCB SP, 06 to 40 Amps 240 volts, AC, 10 KA breaking capacity 'C' Series, \\"ISI marked complete all as specified and directed. |
| 72 | M&L for Servicing/testing of Metering indoor building Panels, 03/01 Phase, 415/230 Voltscomplete all as specified and directed as per followings :-(i) Repair/replacement of damaged hinges and locks/latches of each compartment.(ii) Cleaning of existing bus bars with CTC applying with red solution, providing bus bar insulation and refixing with new nuts, bolts, washers etc.(iii) Replacement of damaged copper cable and fixing new copper cable for incoming and outgoing connections of each MCCB/MCBs switches alongwith lugs terminals to bus bars including connector.(iv) Replacement of damaged cable protection pipe and damaged/wornout cable insulation and lugs of any size for incoming & outgoing cables.(v) Replacement of neoprene gasket and transparent acrylic sheet 3 mm for all doors of panel board.(vi) Removing, cleaning and refixing/refixing of elctric meter including connection of concerned qtrs complete. Note : Replacement of unserviceable MCCB/MCBs shall be measured & Paid separately. |
| 73 | M&L in replacement for earthing with galvanised steel earth plate electrode 60cmx60cmx 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed. (NOTE:-GI earth wire and protection pipe beyond 7.5m will be measured and paid separately) |
| 74 | S&F in replacement of old sketch fitting/any type by decorative wall mounted LED lamp (white/warm) complete all as specified and directed. |
| 75 | S&F in replacement of decorative wall mounted LED lamp (white/warm) for main gate complete all as specified and directed.Note for all above :-(a) Contractor/his rep/his electrician will attend the complaint cell perodically all as directed by EIC, any ladder/eqpt/necessary electrical tools to check and troubleshoot electrical complaints for various location of AFMC is all inclusive .(b) Complaint related to no lights, replacing of switches, sockets, , replacing burnt MCB, short circuit, voltage fluctuation due to internal wiring, repair to faulty earthing etc will be attended withing 8 hour of raising complaint.(c) The complaint can be registered Telephonic/complaint slip, WhatsApp and any other mode of communication. Please Enable Macros to View BoQ information |