| 1 | Supplying and fixing following size modules GI box along with modular base and cover plate for modular switches in recess etc as reqd |
| 2 | 1 or 2 Module |
| 3 | 3 Module |
| 4 | 4 Module |
| 5 | 6 Module |
| 6 | 8 Module |
| 7 | 12 Module |
| 8 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group B |
| 9 | Group B |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box i/c connections but excluding modular plate etc. as reqd |
| 11 | 5 amp switch |
| 12 | 5 amp socket |
| 13 | 15 amp switch |
| 14 | 15 amps socket |
| 15 | Bell Push |
| 16 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 17 | Suppling and fixing suitable sie GI Box modular Plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connection etc. as reqd |
| 18 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group B |
| 19 | Supplying and fixing Brass batten/angle holder including connection etc as reqd |
| 20 | Supplying and fixing 3 pin . 5 amp ceiling rose on the existing junction box/wooden block including connections etc as reqd |
| 21 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 22 | 1x1.5 sqmm |
| 23 | 2x1.5 sqmm |
| 24 | 2x4 sqmm |
| 25 | 2x6 sqmm |
| 26 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 27 | Supplying and fixing call bell/buzzer suitable for single phase , 230 Volts complete as reqd |
| 28 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required |
| 29 | Supplying and fixing following way, horizontal type three pole andneutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 30 | 6 way (4 + 18), Double door |
| 31 | 8 way (4 + 24), Double door |
| 32 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 33 | Single Pole |
| 34 | Double pole |
| 35 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 36 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required |
| 37 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 100 A |
| 38 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 39 | 4X10 sq.mm + 2 X 6 sq. mm earth wire |
| 40 | Supply, Instalation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover desig, T waty |2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.3 Sq.mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1X1-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18w 865 T81-2100lm |
| 41 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I2100lm |
| 42 | Replacement of condenser of 2.5/3.15 mfd for ceiling fan including making necessary connections etc. complete as required |
| 43 | Supply, installation, testing and commissioning of 7.5 HP, Direct on line starter with sheet steel enclosures suitable for 3-phase, 440V, complete set with contractor & OLR, start, stop push button with indicator lamps, voltmeter, ammeter, including mounting arrangement of starter with all accessories etc. as required. Make havells URJA-DOL submersible pump controller (standard) - 3 phase, CatNo.IHSDOAL1*A or equivalent model of Crompton / BCH Electric Limited |
| 44 | Supply, installation, testing and commissioning of Monoblock pump set, cast Iron body, bronze Impellor, having minimum head (6-40) meter, discharge (9-4) LPS, 3 phase, 440V, 50 Hz making of cable termination etc completed as required,, Make Kirloskar, Cat.No. KDS 538+ or equivalent model of KSB/ Grundfos/ Mody/ Crompton/ CRI/ Beacon/ ABB/ Xylem |
| 45 | Supply, Installation,testing and comissioning of 12 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required |
| 46 | Supply, Installation,testing and comissioning of 15 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connectionetc. as required |
| 47 | Supply, Installation,testing and comissioning of 18 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connectionetc. as required Please Enable Macros to View BoQ information |