| 1 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work20 mm dia nominal bore |
| 2 | 25 mm dia nominal bore metre |
| 3 | 32 mm dia nominal bore |
| 4 | 40 mm dia nominal bore |
| 5 | 50 mm dia nominal bore |
| 6 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 7 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required:20 mm nominal bore each |
| 8 | 25 mm nominal bore each |
| 9 | 32 mm nominal bore each |
| 10 | 40 mm nominal bore each |
| 11 | 50 mm nominal bore each |
| 12 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 13 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - chargeNominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 14 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M20 grade with minimum cement content of 270 kg /cum |
| 15 | Total Cost Including GST factor & Cost Index @ 3% |
| 16 | Gate Valve CPVC 20 mm Dia |
| 17 | Gate Valve CPVC 25 mm Dia |
| 18 | Gate Valve CPVC 50 mm Dia |
| 19 | Elbow CPVC20mm/20mm |
| 20 | Elbow CPVC50mm/20mm |
| 21 | Elbow CPVC25mm/25mm |
| 22 | Elbow CPVC40mm/40mm |
| 23 | Socket CPVC50mm Dia |
| 24 | Tee CPVC40mm/20mm |
| 25 | Tee CPVC25mm/25mm |
| 26 | Tee CPVC32mm/32mm |
| 27 | Tee CPVC40mm/40mm |
| 28 | Union CPVC32mm Dia |
| 29 | Reducer CPVC40mm/50mm |
| 30 | 40mm/25mm CPVC Plain Bush |
| 31 | Male Threade Tee CPVC Plain & Brass Threaded20mm/20mm |
| 32 | Male Threade Tee CPVC Plain & Brass Threaded25mm/20mm |
| 33 | Hex Nipple GI50mm |
| 34 | Hex Nipple GI40mm |
| 35 | Hex Nipple GI32mm |
| 36 | Hex Nipple GI25mm |
| 37 | Plug 40mm GI |
| 38 | Providing and fixing Brass gate valve25 mm nominal bore each |
| 39 | Providing and fixing Brass gate valve20 mm nominal bore each |
| 40 | Providing and fixing Brass gate valve40 mm nominal bore each |
| 41 | Providing and fixing Brass gate valve50 mm nominal bore each |
| 42 | Providing and fixing Brass gate valve65 mm nominal bore each |
| 43 | Providing and fixing Brass NRV25 mm nominal boreHorizontal |
| 44 | Providing and fixing Brass NRV50 mm nominal boreHorizontal |
| 45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work20 mm nominal dia Pipes |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work40 mm nominal dia Pipes |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work50 mm nominal dia Pipes |
| 48 | Supplying and spreading of sand in Lawn area, including watering, mixing and dressing complete. |
| 49 | Total Cost Including GST factor & Cost Index @ 3% |
| 50 | Gate Valve CPVC20mm Dia |
| 51 | Gate Valve CPVC40mm Dia |
| 52 | Tee CPVC40mm/20mm |
| 53 | Excavating, Laying, Jointing & Commissioning PVC pipes from 40mm OD including fitting. Trench size minimum 600mm deep for submain line, backfilling with compaction & removing excess soil upto 50m lead from site. Include installation and commissioning of all irrigation hardwares like PVC Pipe 40mm, Valves, Filter Unit, ARV, PRV Pressure Guage, Flush Valve & Inline brown color Polytube with dual-layer black from Inside and brown from outside with 16mm dia. , 0.30 meter spacing of dripper, 2Lph discharge with pressure rating 0.8 to 6 bar, wall thickness 1.1mm With All Necessory fittings Like Take off , Gromet , connector, tees, elbows, end caps & Lateral Stake etc. as Excavating, Laying, Jointing & Commissioning PVC pipes from 40mm OD including fitting. Trench size minimum 600mm deep for submain line, backfilling with compaction & removing excess soil upto 50m lead from site. Include installation and commissioning of all irrigation hardwares like PVC Pipe 40mm, Valves, Filter Unit, ARV, PRV Pressure Guage, Flush Valve & Inline brown color Polytube with dual-layer black from Inside and brown from foutside with 16mm dia. , 0.30-centimeter meter spacing of dripper, 2Lph discharge with pressure rating 0.8 to 6 bar, wall thickness 1.1mm With All Necessory fittings Like Take off , Gromet , connector, tees, elbows, end caps & Lateral Stake etc. as required. Complete as per drawing, specifications, instruction & directions of the engineer-in -charge. |
| 54 | SITC of Irrigation controller with Electric Control Valve which shall be normally closed 11VDC 50/60 cycle solenoid actuated globe/angle pattern design with Bluetooth battery operated single Valve Controller having a DC Latching Solenoid in a plastic adopter that hand-screws onto solenoid valve, one programming Knob to access all the liinction, 7 run times, standby liinction which prevents an unncessary irrigation during raining weather, resin - encased electronic components, silicone filled cavities, & waterproof battery compartment allow operation even in flooded valve boxes, removable programming knob to prevent tempering with all accessories like wire, dvr connectors, battery etc. |
| 55 | Supply, Installation, Testing & Commissioning of Pipe line PVC Pipe conforming to IS:4985:2000 with all fittings and accessories, e.g. couplings, tees, bends, reducers, end plugs etc., jointing by solvent cement method as per manufacturers recommendations all complete including excavation in all kind of soil and back filling. Excavation depth of main line 600mm & section line 450mm.UPVC Pipe - Supreme / FinolexPVC Pipe 63mm 10KG |
| 56 | Supply, Installation, Testing & Commissioning of Pipe line PVC Pipe conforming to IS:4985:2000 with all fittings and accessories, e.g. couplings, tees, bends, reducers, end plugs etc., jointing by solvent cement method as per manufacturers recommendations all complete including excavation in all kind of soil and back filling. Excavation depth of main line 600mm & section line 450mm.UPVC Pipe - Supreme / FinolexPVC Pipe 50mm 10KG |
| 57 | Conduit Pipe 2mm wall thickness OD 3/4\\" |
| 58 | SITC of The sprinkler shall be of the gear-driven, rotary type, capable of covering a 43 - 77 foot (13 - 23.5 m) radius at 40 - 90 PSI (2.8 - 6.2 bar) with a precipitation rate of 0.48 - 1.3 inches per hour. The sprinkler shall be available in a high speed (14053) or low speed (14003) rotation. Each sprinkler shall be available with six (6) color-coded nozzles with a trajectory of 26° discharging from 5.1– 32.5 GPM (19.3-123.1 l/m) which incorporates three (3) discharge ports per individual nozzle. |
| 59 | SITC of Swing Joint 1”. Its Flexible Swing Arm And Joints allow easy adjustment of head to grade. It Reduce Potential for leaks with flexible Parts that wont break or crack under stress like rigid fittings. It has Operating Pressure upto 6kg/cm² and Surge Pressure upto 10kg/cm² and having temperature upto 60°C. It has maximum flow 1800 litre per hour. |
| 60 | SITC of PP Service Saddle- (50mm - 63mm) X 1\\" |
| 61 | SITC of 1\\" Brass Quick coupling valve |
| 62 | SITC of 1\\" Brass Quick coupling key |
| 63 | SITC of Brass Swivel Hose Elbow 3/4\\" * 3/4\\" |
| 64 | SITC of Valve box 7\\" Rectangular Valve Box with cover. The valveboxes shall be high strength, high density polyethylene constructed material. It should be UV stabilizer with anti-oxidants, resistant to moisture. - |
| 65 | SITC of PP Service Saddle 75mm X 1\\" |
| 66 | SITC of Main Line Isolation Ball Valve 75mm |
| 67 | SITC of PVC double Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechancal, ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 63mm. with pressure rating PN 16 |
| 68 | SITC of Valve box 12\\" rectangluar Valve Box with cover. The valveboxes shall be high strength, high density polyethylene constructed material. It should be UV stabilizer with anti-oxidants, resistant to moisture. |
| 69 | SITC of Disc Filter 2\\" (25 m³/hr)With the excellent disc technology T type disc filter have micron - precise, high efficiency and large volume filteration advantage. The well-designed diagonally grooved structured provide |
| 70 | SITC of back mounted Connection Pressure Gauze (glycerin filled)- |
| 71 | SITC of a double acting Continuous Air release valve 2\\". The Continuous Air release valve shall be capable of both releasing and admitting air from and into the line during system operation. |
| 72 | SITC of Pressure Relief valve 2\\" with bypass outlet. |
| 73 | SITC of Openwell Booster Pump 25HP. |
| 74 | SITC of UPVC / ASTM fittings for pump Suction (2\\"), Delivery Header Pipe(2\\") |
| 75 | SITC of Brass Non Return Valve 2.5\\". |
| 76 | SITC of 2\\" Solenoid Valve. The valve shall be a normally closed, electronically actuated, diaphragm-operated, remote control zone valve. The valve shall be capable of operating between 20 and 150 PSI (0.7 bars 10.3 bars) with a flow range of between 5 and 120 GPM (19 L/M and 454 L/M). The valve body shall be constructed of heavy duty, corrosion and UV Resistant PVC, rated to 150 PSI (10.3 bars). |
| 77 | SITC of The Pro-LC having 12 Station is an affordable, conventional controller with many of the features of the reliable and robust Pro Ex 2.0 controller .Available in fixed 4, 8 or 12 stations, and as indooror outdoor models, these compact controllers offer an array of user-friendly features including easy to follow programming; a full program screen display listing watering days, number of start times, numberof stations and special programming; large LCD display; rain/freeze sensor compatibility; seasonaladjust for water conservation; a buried valve locator for easy maintenance and more. K-Rain (USA) |
| 78 | SITC of 18 AWG Double insulated Single Core Copper Conductor White Cable . |
| 79 | SITC of 18 AWG Double Insulated Single Core Copper Conductor Red Cable. |
| 80 | SITC of DBR Connectors. It shall be pre filled, low voltage, dry splice, Direct Bury, water proof wire connector that protect electrical connection from corrosion and moisture. Each splice Kit contains Two wire nuts, water proof, Gel- filled housing and 1 dual splice organizer . |
| 81 | SITC of Rain Sensor. |
| 82 | Supplying and laying of bermuda grass including spreading, ramming/compaction using the specified heavy wieght rollar, watering and dressing complete as per the direction of Engineer-In-Charge. |
| 83 | Supplying, Installation, Testing and Commissioning of three phase openwell ISI Marked submersible pump set of 7.5 H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compatible for operations on dynamic variable frequency / speed having IP 68 Protection including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. and making of flexible IP68 cable connections including removal of old pump etc. complete as required. |
| 84 | Supplying, Installation, Testing and Commissioning of three phase open well ISI Marked submersible pumpset of 1.5H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compatible for operations on dynamic variable frequency / speed having IP 68 Protection including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. and making of flexible IP68 cable connections etc. complete of suitable head and discharge including removal of old pump etc. complete as required. |
| 85 | Supplying, Installation, Testing and Commissioning of three phase openwell ISI Marked submersible pump set of 10 H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compatible for operations on dynamic variable frequency / speed having IP 68 Protection including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. and making of flexible IP68 cable connections including removal of old pump etc. complete as required. |
| 86 | Supplying, Installation, Testing and Commissioning of three phase openwell ISI Marked submersible pump set of 5.5 H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compatible for operations on dynamic variable frequency / speed having IP 68 Protection including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. and making of flexible IP68 cable connections including removal of old pump etc. complete as required. |
| 87 | Welder flange 50mm |
| 88 | Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 89 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal ofunserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 90 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 91 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 92 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 93 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 300 mm |
| 94 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 95 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work,including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100 mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc including cost of cartage, all leads & lift, handling at site etc.all complete as per direction of Engineer-in-Charge. |
| 96 | Providing and fixing in position pre-cast R.C.C. manhole cover and frameof required shape and approved quality H D - 20 Circular shape 560 mm internal diameter |
| 97 | Cleaning of underground sump, including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) Carrying out minor patch repairs wherever required.Cleaning of the inlet and outlet pipelines, including chambers along the flow path.as per direction of Engineer-in-Charge. |
| 98 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 99 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work,including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100 mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc including cost of cartage, all leads & lift, handling at site etc.all complete as per direction of Engineer-in-Charge. |
| 100 | Supplying and stacking at siteGood earth |
| 101 | Un-skilled labour |
| 102 | Sewermen |
| 103 | Beldar |
| 104 | Hire and running charges of tipper |
| 105 | Hire and running charges of loader |
| 106 | Total Cost Including GST factor & Cost Index @ 3% Please Enable Macros to View BoQ information |