Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5.10.7 |
| 2 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.5.7.3 |
| 3 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. B.C.D 5.7.6 |
| 4 | Providing one coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. 5..8.19 |
| 5 | Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) 13.47.1 D.S.R |
| 6 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.5.10.10 |
| 7 | Supplying, fitting and fixing 38mm , thick good quality well dressed and well seasoned wood fully paneled shutters( frame made of sal wood and panelsof sisum wood) in doors and window with 25mm, thick panels with one side plain and other side chamfered with aluminium fittings such as hinges, sliding door, bolts, tower bolts, handled or rings, hooks and eyes, cleats, sand blocks as per schedule, taxes and royalty all complete as per building specification and direction of E/I. 5.4.13 |
| 8 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. B.C.D 5.8.45 |
| 9 | Providing two coats of painting with ready mixed paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. 5.8.28 |
| 10 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 12.41.2 D.S.R |
| 11 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.4.2 DSR |
| 12 | Single tee with door 12.42.3.2 110x110x110 mm 12.42.3.2 |
| 13 | Bend 87.5° 110 mm bend 12.42.5.2 |
| 14 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.5.5.29 |
| 15 | sand lead 20km (p) |
| 16 | cement lead 3 km (p) |
| 17 | Wiring for light/point/Exhaust fan point/call bell point with 1.5 sq.mm FRPVC insulated copper conductor cable in surface/recessed PVC conducit as required. With piano type switch phenolic laminated sheet MS Box earthing the point PVC insulated copper 1.5 Sq.mm FR PVC insulated copper conductor single core cable etc. at required. 1.13 |
| 18 | 95Sq. mm 3.5 core cable |
| 19 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface/racessed PVC conduit as required. M739 |
| 20 | 1.7.5 :- 2x10 sqmm+1x10 sqmm earth wire |
| 21 | 1.7.12 :- 4x16 sqmm+2x6 sqmm earth wire |
| 22 | Supplying and fixing suitable size GI box/PVC do………do…… all complete job |
| 23 | 1.22.8 :- 170x221x48mm |
| 24 | 1.22.1 :- 75x75x50mm |
| 25 | Modular base & cover plate for 6 module |
| 26 | Modular base & cover plate for 8 module |
| 27 | Modular base & cover plate for 12 module |
| 28 | Supplying and fixing of following way single pole & neutral, sheet steel , MCB distribution board 240 volts, on surface /recess , complete with tinned copper bushbars ,neutral busbar, earth bar , din bar ,detachable gland plate , interconnections ,phosphatized and powder painted including earthing etc. as requried. (but without MCB/RCCB/ISOLATOR) M533 |
| 29 | Supplying and Fixing- C series MCB 6/32/Amps TPN do……do……. All complete job M534 |
| 30 | Supplying and Fixing- C series MCB 6/32/Amps SPN do……do……. All complete job M535 |
| 31 | Supplying and fixing following rating four pole 415 volts Isolator in the existing MCB DB complete with connections testing and commissioning etc as required |
| 32 | ITC ceiling fan installation |
| 33 | ITC exhaust fan upto 450mm sweep installation |
| 34 | Supplying Installation ,testing and commissioning of following size ceing fan 3 blades conforming to IS : 374:2019 including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm FR PVC insulated ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required. 1200 mm (48'') Ceiling fan |
| 35 | Supplying 300 mm exhust Fan 12'' (300 mm) |
| 36 | Supplying LED 15/16 Watt |
| 37 | LED flood LIGHT 200 W |
| 38 | S/F Batten Holder -Do - -do- |
| 39 | Providing & Fixing 100 Amp 4 Pole on off Changeover Switch |
| 40 | Supplying and fixing suitable size GI/ pvc box of 121 mmx 173 mmx 48 mm on surfae or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 amps socket outlret and 15/16 amps piano type switch.connection etc. required |
| 41 | supplying and fixing following piano type switch/socket on the exiting box/ cover including connections etc as required 3 pin 5/6 A socket outlet Each |
| 42 | 5/6 amps switch |
| 43 | Double LED tubelight fitting made of Die cast aluminium housing 2 x20 watt bettal tubelight suitable for surface mounted |
| 44 | Steel circular hollow pole of standard specification for street lighting to mount light at 9m height above road level including foundation with pcc |
| 45 | Single Arm 1 m long |
| 46 | LED STREET light (90/100 W) |
| 47 | Supplying fitting and fixing viterous shite glazed earthen ware I.W.C. of parry hindustan or any other I.S.S approved make with 100 mm H.C.I. \\"p\\" trap 15 litres C.I.. Or C. pull and let go flushing clstern of name or other I.S.S equivalent make, complete with all fitting,C.i.. or C.C brackets 32 mm alkathene/P.V.C telescopoc flush,pipe about 2 M long with one brass coupling and clamps G.I chain pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I body brass spindle stop cock of weigth not less than 50 grms. 15mm P.V.C connection pipe 450 mm long and the exposed pipe amd cistern with two coats of approved paint over a coat of red oxide primer etc all complete as per specification and direction of E/I. (C) 450 mm long I.W.C (b)with 12.5lit. low level C.I cistern |
| 48 | Providing fitting and fixing vitreous white glazed earthen ware Wash hand basinof parry hindustan or any other I.S.S approved make supported on painted C.I or R.S brackets with 32mm C.I,15mm dia C.I body brass spindle stop cock of approved quality of weight not less than ,350 grams ,32 mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc.all complete as per specification and direction of E/I. |
| 49 | Providing and fixing male ended 15 mm dia brass bib cock of approved quality (wt. not less than 350 gms) with extra socket all complete as per specification and direction of E/I. |
| 50 | Supplying fitting and fixing (b) mirror of 6mm thick glass bevelled edge mirror including C.P brass revolving fitting 3mm ply wood board and C.P hinges to fix with mirror. Complete with all materials as per specification and direction of E/I. (i) 600mm x450mm size |
| 51 | (C) (i)C. P brass towel rail 20mm x 600mm with bracket container |
| 52 | Providing and fixing CPVC pipes all complete job. Exposed on Wall20 mm nominal outer dia Pipes |
| 53 | 32 mm nominal outer dia Pipes |
| 54 | Conselled 15mm dia |
| 55 | Polythene water storage tank of mark with cover and suitable lcocking system in double layer confirming to Is 12701-1996 with ;atest revision |
| 56 | For gateDismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5.10.1 |
| 57 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. 5.2.14 |
| 58 | Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees,Extra for earthwork in hard soil as per specification and direction of E/I. 5.1.1+5.1.2 |
| 59 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building 5.1.10 |
| 60 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.5.6.3 |
| 61 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) 5.3.2.3 |
| 62 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centring and shuttering ,finishing and reinforcement-all work upto plinth level:1:1.5:3 (1 cement : 1.5 coarse sand (zone III) : 3 graded stone aggregates 20 mm nominal size) 5.3.9.1 |
| 63 | Reinforced cement concrete work in walls(any thickness),including attached pilaster,buttresses,plinth and string courses ,fillets ,columns,pillars,piers,abutments,posts and struts etc above plinth level upto floor five level,excluding cost of centring ,shuttring,finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (zone III) : 3 graded stone aggregates 20 mm nominal size) 5.3.10 |
| 64 | Centering and shuttering including strutting,propping etc and removal of from for columns, pillars, piers,abutment,posts and struts 5.3.17.6 |
| 65 | Reinforced cement concrete work in beams , suspended floors, roofs having slope up to 15 degree landings, balconies , shelves, chajjas , lintels , bands , plain window sills , staircases and spiral stair cases above plinth level up to floor five level , excluding the cost of centering , shuttering finishing and reinforcement , with 1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 5.3.11 |
| 66 | Centering and shuttering including strutting,propping etc and removal of from for lintels, beams, plinth beams, girders, bressumers and cantilevers 5.3.17.5 |
| 67 | Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I 5.7.2 |
| 68 | Providing Tor steel reinforcement of rods as per approved design and drawing including carriage of Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust,-do- 5.5.5 |
| 69 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all complete as per specification and direction of E/I and Providing primer one coat or red lead paint of approved makeover new steel surface -do-- 5.8.41 +5.8.43 |
| 70 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent 11.55.1 dsr |
| 71 | Providing two coat snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper. Scaffolding, curing and taxes all complete as pr building specification and direction of E/I. 5.8.24 |
| 72 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. 16.18 |
| 73 | i. Cement + Steel |
| 74 | i. Sand |
| 75 | iii Stone Chips |
| 76 | iv stone metal |
| 77 | (V) bricks |
| 78 | First floor hallDismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5.10.1 |
| 79 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5.10.3 |
| 80 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) 5.3.10 |
| 81 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).5.3.11 |
| 82 | Centering and Shutering including strutting propping etc.and remove all Column, pillers, piers and abutment etc 5.3.17.6 |
| 83 | Lintels, Beams, Plinth Beam and Girders etc 5.3.17.5 |
| 84 | Suspended floors roofs landing balconies and access platform 5.3.17.3 |
| 85 | Providing designation 75A brick work in C.M. (1:6) in superstructure with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. 5.2.11 |
| 86 | Providing tor steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved deign and drawing as per building specification and direction of E/I (a) 10mm (TMT coil Fe 500) (only valid for TATA(Tucson), SAIL, JSPL, Elcetrosteel Ltd. Bokaro and Vizag(RINL) (b) 12mm (TMT coil Fe 500) (only valid for TATA(Tiscon), SAIL, JSPL, Elcetrosteel Ltd. Bokaro and Vizag(RINL) (c) 16mm (TMT coil Fe 500) (only valid for TATA(Tiscon), SAIL, JSPL, Elcetrosteel Ltd. Bokaro and Vizag(RINL) 5.5.4 |
| 87 | Providing 12mm thick cement plaster (1:6) as per building specification and direction of E/I 5.7.3 |
| 88 | Providing 6mm. Thick cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 as per building specification and direction of E/I 5.7.6 |
| 89 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 13.26 |
| 90 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. 5.8.21 |
| 91 | Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 13.47.1 |
| 92 | Three track three panels sliding window with two glazed & one wire mesh panels with aluminium channel for roller track, wool pile, nylon rollers with SS 304 body 9.147.A4.1 D.S.R |
| 93 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I 5.5.12 |
| 94 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. 5.8.45 |
| 95 | Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer-in-charge. 9.145 dsr |
| 96 | Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and 9.146 dsr |
| 97 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . 5.6.28 |
| 98 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. 5.6.23 |
| 99 | Sand (Lead 18 Km.(P)) |
| 100 | Brick (Lead 12 Km.(P)) |
| 101 | Stone Chips (Lead 16Km.(P)) |
| 102 | Cement + rod (Lead 11Km.(P)) |
| 103 | Paver blockEarth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.5/5.1.1 |
| 104 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) 5.1.8 |
| 105 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) 5.1.10 |
| 106 | Providing designation 75B one Brick flat soling as per building specification and direction of E/I 5.6.3 |
| 107 | Providing designation 75B brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. 5.2.6 |
| 108 | Provinding and laying 60 mm thick factory made cement concrete interlocking paver block of m-30 grade by blocking compaction and pattern over and including 50 mm thick compaction of approved size and design and shape laid in required colour and pattern and bed of coarse sand filling the joints with fine 16.68 dsr |
| 109 | Providing Plain cement concrete in open foundation complete as per drawing and technical specifications p.c.c m-15(1:2:4)do-do- E/I 5.3.1.2 |
| 110 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 111 | Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 13.47.1 |
| 112 | s/chips |
| 113 | Cement |
| 114 | PlatformProviding designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. 5.2.3 |
| 115 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) 5.1.8 |
| 116 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) 5.1.10 |
| 117 | Providing designation 75-B one brick flat soling joint filled by local sand all complete as per building specification & direction of E.I 5.6.3 |
| 118 | Providing Plain cement concrete in open foundation complete as per drawing and technical specifications p.c.c m-15(1:2:4)do-do- E/I 5.3.1.2 |
| 119 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.5.7.3+5.7.11 |
| 120 | sand(AVG LEAD 20 km(p) |
| 121 | s/chips( AVG LEAD 15 km(P)) |
| 122 | bricks(AVG LEAD 15 km(P)) |
| 123 | Cement (Lead 03 Km.(P)) |
| 124 | Kitchen roomEarthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance up to 50 M including all lifts levelling ramming the foundation trenches removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I. 5.1.1 |
| 125 | Extra for earthwork in hard soil as per. Specification and direction of E/I (Vide classification of Soil item _B) 5.1.2 |
| 126 | Filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) 5.1.7 |
| 127 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per buy lading specification and direction of E/I (Mode of measurement compacted volume). 5.1.10 |
| 128 | Providing designation 75B one Brick flat soling as per building specification and direction of E/I 5.6.3 |
| 129 | Providing P.C.C M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 excluding screening shuttering mixing cement concrete in mixer and placing in position, vibrating, striking, curing taxes and royalty all complete as per building specification and direction of E/I 5.3.1.2 |
| 130 | Providing R.C.C M-200 with nominal mix of (1:1.5:3) in column and plinth with approved quality of Stone as per building specification and direction of E/I 5.3.14 |
| 131 | Centering and Shutering including strutting propping etc.and remove allFoundation, Footing bases of Column etc for mass concrete 5.3.17.1 |
| 132 | Column, pillers, piers and abutment etc 5.3.17.6 |
| 133 | Lintels, Beams, Plinth Beam and Girders etc 5.3.17.5 |
| 134 | Suspended floors roofs landing balconies and access platform 5.3.17.3 |
| 135 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. 5.2.48 |
| 136 | Providing 50mm thick damp proof course with cement concrete M-15 with nominal mix of (1:2:4) with approved as per building specification and direction of E/I 5.3.5 |
| 137 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.5.2.52 |
| 138 | Providing and fixing fan hook of 16mm dia M.S bar 1 metre long bent to required size and shape placed in position and fixed in R.C.C slab/beam at the time of casting all complete as per building specification and direction of E/I5.5.13 |
| 139 | Providing tor steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved deign and drawing as per building specification and direction of E/I (a) 10mm (TMT coil Fe 500) (only valid for TATA(Tucson), SAIL, JSPL, Elcetrosteel Ltd. Bokaro and Vizag(RINL) (b) 12mm (TMT coil Fe 500) (only valid for TATA(Tiscon), SAIL, JSPL, Elcetrosteel Ltd. Bokaro and Vizag(RINL) (c) 16mm (TMT coil Fe 500) (only valid for TATA(Tiscon), SAIL, JSPL, Elcetrosteel Ltd. Bokaro and Vizag(RINL) 5.5.4 |
| 140 | Providing 12mm thick cement plaster (1:6) as per building specification and direction of E/I 5.7.3 |
| 141 | Providing 6mm. Thick cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 as per building specification and direction of E/I 5.7.6 |
| 142 | Supplying fitting and fixing M.S grill made of 20x60mm M.S. flat as per approved design and drawing properly fabricated with joints continuous fillet welded and finished smooth carriage of grill to work site hoisting as per building specification and direction of E/I 5.5.12 |
| 143 | Supplying fitting and fixing 20 gauge G.C.I. Sheet gate fitted on M.S. Angle frame of size 60x60x6mm. Including cost of fabrication providing necessary locking arrangement with Haskell and downy duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction E/I. 5.5.29 |
| 144 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface all complete as per building specification and direction of E/I. 5.8.45 |
| 145 | Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. 5.8.20 |
| 146 | Providing 50mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. 5.6.9 |
| 147 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . 5.6.28 |
| 148 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. 5.6.23 |
| 149 | White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 17.7.3 |
| 150 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 18.49 dsr |
| 151 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15 mm nominal dia Pipes DSR18.7.1 |
| 152 | 20 mm nominal dia Pipes 18.7.2 dsr |
| 153 | 32 mm nominal Outer dia Pipes 18.8.4 dsr |
| 154 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent for kitchen slab 11.55.1 |
| 155 | S/F/F Vitreous white glazed earthen ware wash Kitchen Sink 600 x450 x250 mm 3.2.6 (i) |
| 156 | Brick |
| 157 | Stone Chips |
| 158 | Cement + rod |
| 159 | NON SCHEDULE ITEMGeM Portal GODREJ INTERIO 2 - Tier bunk beds(Fixed) for Adult (1910mm965mm) Each bed Rs.42952.00 x 20 Nos = |
| 160 | Goods & Service Tax (G.S.T.) - |
| 161 | Labour Cess - Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy