| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(a) In ordinary soil |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 3 | P.C.C. and SOLING WORK : Providing brick soling in foundation and under floor Modular common burnt clay bricks of class designation 7.5, sand packed and laid to level and in panel after preparing the sub-grade as directed including all labour and materials, and if necessary dewatering, |
| 4 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from naturalsources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources) In prop. 1 cement :3 sand : 6 coarse aggregate by volume. |
| 5 | R.C.C. WORK : Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) c) M20 grade concrete |
| 7 | DPC WORK: Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) |
| 8 | BRICK WORK :Brick work with common burnt clay modular bricks of class designation7.5 in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand) |
| 9 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 10 | SHUTTERING AND FORM WORK :Centering and shuttering including strutting, propping etc. and removalof form forFoundations, footings, bases of columns, etc. for massconcrete |
| 11 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 12 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 13 | Suspended floors, roofs, landings, balconies and accessplatform |
| 14 | FLOORING :VITRIFIED TILES:52 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate 6 mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacturer'sspecifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete |
| 15 | Glazed vitrified floor tiles polished finish of size 1200x1200 |
| 16 | ANTISKID TLES: Providing and laying Vitrified tiles in floor in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm includinggrouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gentlyand easilyGlazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.5 Size of Tile 1200 x 1200 mm |
| 17 | WALL TILES:Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigmentsetc. complete 11.46.4 Size of Tile 1000x1000 mm |
| 18 | MARBLE FLOORING:Marble stone flooring with 18 mm thick marble stone, as per sampleof marble approved by Engineer-in-charge, over 20 mm (average) thickbase of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith grey cement slurry, including rubbing and polishing completewith Makrana white second quality |
| 19 | Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).08-05-202611.20.1 Light shade pigment using white cement |
| 20 | PLASTERING :15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) |
| 21 | 12 mm cement plaster of mix ::\\"1:4 (1 cement: 4 fine sand) |
| 22 | Door and Window Frame WORK08-05-2026Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle thresholdof mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge:10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb |
| 23 | Aluminium Window:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 24 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 25 | DOOR and WINDOW WORKS:Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid forseparately, all complete as per direction of Engineer-in-charge. (Note:-Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock wood 35 mm thick shutters for doors |
| 26 | 25 mm thick PVC flush door shutters made out of a one pieceMulti chamber extruded PVC section of the size of 762 mm X25 mm or less as per requirement with an average wallthickness of 1 mm (± 0.3 mm). PVC foam end cap of size23x10 mm are provided on both vertical edges to ensure theoverall thickness of 25 mm. M.S. tube having dimensions 19mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along thehinge side of the door. Core of the door shutter should be filledwith High Density Polyurethane foam. The Top & Bottom edgesof the shutter are covered with an end-cap of the size 25 mmX 11 mm. Door shutter shall be reinforced with specialpolymeric reinforcements as per manufacturer’s specificationand direction of Engineer-in-charge to take up necessaryhardware and fixtures. Stickers indicating the locations ofhardware will be pasted at appropriate places |
| 27 | M.S GRILLS Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete (a) Fixed to wooden frames |
| 28 | S.S RAILING Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 29 | PUTTY Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete |
| 30 | PAINTING (i).PrimingApplying priming coats with primer of approved brand andmanufacture, having low VOC (Volatile Organic Compound ) content. coat with alkali resistant primer. With water thinnable cement primer on wall surfacehaving VOC content less than 50 grams/litre Two coats |
| 31 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Two coats |
| 32 | Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50grams/ litre of approved brand and manufacture, including applyingadditional coats wherever required to achieve even shade and colour. Two coats |
| 33 | Applying priming coat: With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/steel works |
| 34 | Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete On steel work |
| 35 | Applying priming coat: With ready mixed pink or Grey primer of approved brandand manufacture on wood work (hard and soft wood) |
| 36 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint ofrequired shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture |
| 37 | IRON AND STEEL WORK: Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 38 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level. |
| 39 | HARDWARE FITTINGS : Providing and fixing bright finished brass tower bolts (barrel type) withnecessary screws etc. complete ii) 250mm x 10mm |
| 40 | Providing and fixing bright finished brass handles with screws etc.complete: iii) 125mm |
| 41 | Providing and fixing bright finished brass hanging type floor doorstopper with necessary screws, etc. complete. |
| 42 | Providing and fixing chromium plated brass 100 mm mortice latch andlock with 6 levers and a pair of lever handles of approved quality withnecessary screws etc. complete |
| 43 | Hinges:Providing and fixing ISI marked oxidised M.S. pressed butt hinges withnecessary screws etc. complete.iii) 100mm x 58mm x 1.90mm |
| 44 | PLINTH PROTECTION: Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth. |
| 45 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 46 | Making side drain along with apron for drainage and plinth protect work |
| 47 | FLOORING:VITRIFIED TILES:Providing and laying Vitrified tiles in floor in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm includinggrouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gentlyand easilyDouble charge vitrified tile polished finish of size Size of Tile 600 x 600 mm |
| 48 | Providing and laying Vitrified tiles in floor in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm includinggrouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gentlyand easily. Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 49 | WALL TILES:Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigmentsetc. complete. Size of Tile 500x500 mm |
| 50 | MARBLE FLOORING:Marble stone flooring with 18 mm thick marble stone, as per sampleof marble approved by Engineer-in-charge, over 20 mm (average) thickbase of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith grey cement slurry, including rubbing and polishing completewith Agaria White |
| 51 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 52 | SANITARY Wash Basin Providing and fixing wash basin with C.I. brackets, 15 mm dia CP (White Vitreous China Wash basin size 550x400 mm with a15 mm CP Brass single hole basin mixerBrass single hole basin mixer of approved quality and make, includingpainting of fittings and brackets, cutting and making good the wallswherever required |
| 53 | Towel Ring Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with minimum distances of 37 mm from wall face withconcealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. |
| 54 | Soap Dish Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. |
| 55 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washerscomplete.d. |
| 56 | Pillar Cock Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms 15 mm nominal bore |
| 57 | Bib Cock Providing and fixing C.P. brass bib cock of approved quality conforming15 mm nominal boreto IS:8931 |
| 58 | C.I.GRATING Providing and fixing 100 mm sand cast Iron grating for gully trap 100mm dia |
| 59 | Stop Cock:Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to IS:8931. |
| 60 | EUROPEAN TYPE WATER CLOSET:Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I. brackets,40 mm flush bend, overflow arrangement with specials of standardmake and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lid |
| 61 | FLUSHING CISTERN:Providing and fixing controlled flush, low level cistern made of vitreouschina with all fittings complete10 litre (full flush) capacity-white |
| 62 | VALVE:Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 25 mm dia. |
| 63 | VALVE:Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 20 mm dia. |
| 64 | Piping:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.(i) In internal wall - exposed on wall(c)25 mm OD |
| 65 | Piping:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.(i) In internal wall - exposed on wall(d)32 mm OD |
| 66 | Piping:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.(i) In internal wall - exposed on wall(e) 40 mm OD |
| 67 | Piping:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.Concealed work, including cutting chases and making good the wallsetc. . 25 mm nominal dia Pipes |
| 68 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.:Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.a) In exposed surfaces or in trenches. 110mm dia. |
| 69 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.:Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.a) In exposed surfaces or in trenches. 75mm dia. |
| 70 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°(ii) 110mm dia. |
| 71 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°(iv) 75mm dia. |
| 72 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Shoe Plain or 45 degree(ii) 110mm dia. |
| 73 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Shoe Plain or 45 degree(iv) 75mm dia. |
| 74 | TEE Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door (ii) 110mm dia. |
| 75 | TEE Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door (iv) 75mm dia. |
| 76 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion Coupler (i) 110 mm dia |
| 77 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Single pushfit Coupler (iv) 110 mm x 75mm |
| 78 | WATER TANK:Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 79 | SEPTIC TANK:Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed.50 Users |
| 80 | SOAK PIT AND INSPECTION CHAMBER:Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm drybrick honey comb shaft with bricks and S.W. drain pipe 100 mmdiameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 81 | MAN HOLE COVER:Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weightof the cover to be not less than 23 kg |
| 82 | DEEP TUBE WELL:Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collectingsamples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer -in-charge, beyond 90 metre & upto 150 metre depthbelow ground level.All types of soil 300 mm dia |
| 83 | Supplying, assembling, lowering and fixing in vertical position in borewell, ERW (Electric Resistance Welded) FE 410 plain slotted (havingslot of size 1.6/3.2 mm) mild steel threaded and socketed/ plainbevel ended pipe (type A) of required dia, conforming to IS: 8110, ofreputed and approved make, having wall thickness not less than5.40 mm, including painted with outside surface with two coats ofanticorrosive bitumestic paint of approved brand and manufacture,including hire & labour charges, fittings & accessories, all complete,for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge. 40 mm nominal dia Pipes |
| 85 | Providing and placing in position filters of 40 mm diameter G.I. pipewith brass strainer of approved quality |
| 86 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well is fullydeveloped, measuring yield of well by \\"V\\" notch method or any otherapproved method, measuring static level & draw down etc. by stepdraw down method, collecting water samples & getting tested inapproved laboratory, i/c disinfection of tubewell, all complete, includinghire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge |
| 87 | RCC WORK Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 88 | BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 89 | PAINTING :Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 90 | MS ANGLE : Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. |
| 91 | BARBED WIRE: Fencing with angle iron post placed at required distance embeddedin cement concrete blocks, every 15th post, last but one end postand corner post shall be strutted on both sides and end post on oneside only and provided with horizontal lines and two diagonalsinterwoven with horizontal wires, of barbed wire weighing 9.38 kg per100 m (minimum), between the two posts fitted and fixed with G.I.staples, turn buckles etc. complete. (Cost of posts, struts, earthwork and concrete work to be paid for separately). Payment to bemade per metre cost of total length of barbed wire used. With G.I. barbed wire |
| 92 | EARTH WORK : Excavating, supplying and filling of local earth (including royalty) bymechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. Complete |
| 93 | Preparation and consolidation of sub grade with power road roller of8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road rollerincluding making good the undulations etc. and re-rolling the subgrade and disposal of surplus earthwith lead upto 50 metres. |
| 94 | Laying water bound macadam sub-base with brick aggregate andbinding material, earth etc. including screening, sorting and spreadingto template and consolidation with light power road-roller etc.complete.(payment for brick aggregate and moorum etc. to be madeseparately)Over burnt (Jhama) brick aggregate 120 mm to 40 mm |
| 95 | FLOORING: Providing and laying 60mm thick faciory made cement concreteinterlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved size, design& shape, laid in required colour and pattern over and including 50mmthick compacted bed of coarse sand, filling the joints with line sandetc. all complete as per the direction of Engineer-in-charge. |
| 96 | WATER BOUND MACADAM Laying, spreading and compacting stone aggregate of specified sizesto WBM specifications in uniform thickness, hand picking, rollingwith 3 wheeled road/vibratory roller 8-10 tonne capacity in stages toproper grade and camber, applying and brooming requisite type ofscreening / binding material to fill up interstices of coarse aggregate,watering and compacting to the required density . |
| 97 | PCC Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :PCC GRADE M20 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 98 | Site development work including levelling |
| 99 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 100 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 101 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 102 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 103 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 104 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4X 16 sq. mm + 2 X 10 sq. mm earth wire |
| 105 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 106 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 107 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 108 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch |
| 109 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch |
| 110 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 111 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet |
| 112 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet |
| 113 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push |
| 114 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 115 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 116 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) |
| 117 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) |
| 118 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm) |
| 119 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) |
| 120 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm) |
| 121 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 122 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 6 way, Double door |
| 123 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 124 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door |
| 125 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door |
| 126 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 127 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 128 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 129 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral |
| 130 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply .earthing etc. complete as required |
| 131 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 132 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 133 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 134 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 135 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 Amp, 36KA, FPMCCB |
| 136 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 Amp, 36KA, FPMCCB |
| 137 | Above 95 sq. mm and upto 185 sq. mm |
| 138 | DIESEL GENERATING SETSSupplying installation testing and commissioning of silent type D.G. Set, AMF Panel, Bus Trunking /cables from DG Set to essential panel, control cable, Earthing of DG Set and AMF Panel, DG set exhaust piping as per CPCB norms and minor allied works. Including Extra for synchronizing panels wherever required. |
| 139 | PASSENGER LIFT The lifts shall be with power operated centre opening/side opening doors and AC variable voltage & variable frequency controls, Car safety & Governor, Guides, guide rails, ropes, car platform, cabin finishes (stainless steel), car & landing doors (stainless steel), hoist motors, braking system, Automatic Rescue Device (ARD) etc. complete as per the CPWD Specifications and related IS standards upto date.(Lifts can be with Machine room or Machine room less depending upon site requirement) Provision of lifts will be made as per National Building Code-2016 / relevant BIS amended upto date) considering no of floors, height of the building and speed of elevators;At least one lift in each block be made compliant to barrier free and accessibility requirements as per CPWD specifications & capacity to be minimum 13 passengers for barrier free lift;One lift in each tower should be goods / bed lift, with size and capacity of lift car to be designed accordingly. Provision of fire lifts shall also be ensured as per local fire authorities requirements/bye laws.PASSENGER LIFT CAPACITY: 8 PASSENGER LIFT,Travel speed :1 m/s,travel height :G+4(max) |
| 140 | Supplying with fitting fixing of surface & wall mounted LED luminaries complete with all accessories including driver directly on wall / ceiling including connection with 1.5 sq mm P.V.C. insulated S.C.copper conductor as required and as directed by the department. (Crompton/PHILIPS/ BAJAJ/ Havells or equivalent considering the mother items rate and specification) 18W 4ft LED Batten |
| 141 | Supplying and commissioning of the following indoor recessed Type Round Luminairs complete with all accessories including driver in the false ceiling/surface mounted with necessary support and connection with 1.5sqmm PVC insulated SC copper conductor as required and as directed by the deptt. (Crompton or equivalent make) |
| 142 | Supplying and commissioning of the following indoor LED Wall decorative LIGHTcomplete with all accessories including driver in the false ceiling ( Armstrong / Gypsum or similar type) mounted with necessary support and connection with 1.5sqmm PVC insulated SC copper conductor as required and as directed by the deptt.( wipro or equivalent make) |
| 143 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. (hevells /bajaj or equivelent make). 250mm sweep non metttalic |
| 144 | Supply of following size PVC/XLPE insulated and PVC sheathed 1.1KV gd Solid Aluminum conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape innersheathed, Armour (Aluminium wire for single core up to 70 sqmm, balance Aluminium strip, Glavanised wire for cables upto 2x10 sqmm,, 3x10 sqmm,,4x6 sqmm, & balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable as specified and directed by the deptt. ( Havells or equivelent make). 120.00Sqmm 3.5core |
| 145 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoordoor type floor mounting compartmentalize LT MAIN PANNEL BOARD of made of 16 SWG (1.66 mm) thick C.R. sheet and required size angle having 4 nos legs at the bottom complete neatly wiring done with provision for 160a 4P MCCB one no as incomer and out going as specified and directed by the deptt. confirming to IP 65 protection comprising of the following electrical items. |
| 146 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail