| 1 | Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately).(a) Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr. |
| 2 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof. |
| 3 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof. |
| 4 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof. |
| 5 | Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.andstacking the material at site as directed.(Payment to be made on measurement of portion of roof or wall removed.) |
| 6 | Taking out wind-tie from roof including cutting out rustedbolts, nuts etc. and removing materials to any distance within the compound and stacking. |
| 7 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 8 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately)(a) Upto area 2.5 Sq.m |
| 9 | Labour for taking out steel door and window frame for repairs and re-fixing the same (or replacement by new one) including mending good damages (excluding the cost of repair of damages) andapplying a protective coat of paint. |
| 10 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor(A) [Pakur Variety](a) 1:3:6 proportion |
| 11 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 12 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel : II. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL |
| 13 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(f) 25 mm to 30 mm shuttering without staging in foundation |
| 14 | (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shutteringin any concrete work |
| 15 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth |
| 16 | Brick work on G.C.I shed |
| 17 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.In Ground Floor |
| 18 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(e) Sal : Malayasian |
| 19 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made)(iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.In Ground Floor |
| 20 | Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor:(i) For 25mm. Thick shutter.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.In Ground Floor |
| 21 | Panel (made of single plank) of door and window shutters to design as directed:In Ground Floor(Payment to be made on area of exposed new work). (In case of non-supply of single plank penal rate of reduction to a maximum of 30% will be made).(ii) 19mm thick panel of 30cm to 45cm width(c) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.In Ground Floor |
| 22 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(a) 40mm X 6mm, 250mm Length |
| 23 | (c) 40mm X 6mm, 125mm Length |
| 24 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(iv) 75 x 63 x 3.2mm. |
| 25 | (v) 100 x 63 x 3.2mm. |
| 26 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.(iii) 300mm x 16mm dia. bolt. |
| 27 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: |
| 28 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: |
| 29 | Reparing collapsible gate by cutting out all rivets as necessary reassambling all members including welding pieces of channels, sraightening bent bars and rivetting with new rivets and fitting inposition and painting two coats.In Ground Floor |
| 30 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.In Ground Floor |
| 31 | (ii) Grill weighing above 16 Kg./sq.mtr and above |
| 32 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. |
| 33 | (iv) Two point nose steel handle including fitting and fixing. |
| 34 | (vi) steel peg stay 300 mm long including fitting and fixing. |
| 35 | Supplying fitting and fixing I.R.C. fabric mesh with covering battens including cost of screws etc complete (excluding the cost of battens).In ground floor.(i) 25mm x 25mm x 2.7mm x 2.7mm. |
| 36 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 37 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge.a) 3.90 metre heightTotal nos. for replacing glass panes |
| 38 | b) Extra for additional 3.6 height or part thereof |
| 39 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall)(ii) 4 mm thick |
| 40 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department] |
| 41 | Labour for Chipping of concrete surface before taking upPlastering work. |
| 42 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur varietyIn 1st floor |
| 43 | Application of priming coat for standard bituminouswaterproofing treatment over flat roof with Bitumen primer of approved brand fufilling the provision of I.S. 1346 - 1991 & 3384 - 1986 applied @ 0.27 Liters /Sq.m. over clean and prepared roof surface complete as per satisfaction of the Engineer - in - Charge.All Floor - |
| 44 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.).Membrane Property: Softening Point > 150 deg C, ColdFlexibility < -6 deg C, Tensile Strength, N/cm : 600(longitudinal), 450 (transverse), Tearing Strength, N:300 (longitudinal), 200 (transverse) |
| 45 | Preparation of drainage spout on roof for bituminouswaterproofing treatment after required grading and shaping of the under bed with Cement Concrete (1:2:4) or Cement Mortar (1:4) as directed, Chamfering and moulding the parapet wall to form a bell mouth entry, if required and providing full course treatment with bituminous felt to facilitate quick and smooth drainage of watwr into the down pipes complete including cost of all materials and labouraccording to satisfaction of the Engineer - in - Charge.All floor |
| 46 | Cutting chase upto 125 x 150 mm. and subsequentmending of damages.(a) in brick wall [Cement-3.6 Kg/Mtr] |
| 47 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 48 | Ceiling of commercial ply as per design fitted and fixed complete (excluding the supporting framework but including necessary wood battens of size 40mm x 20mm ).In ground floor(a) Sal Local(ii) 6mm thick |
| 49 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:- |
| 50 | Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping).(A) 300 mm lapping each way(a) With 0.71 mm sheet |
| 51 | Galvanised or painted wind-tie made of M.S. flats, fitted and fixed complete including cost of necessary fittings.(b) Made with 50 mm. X 6 mm. flats |
| 52 | Asbestos corrugated (Trafford or similar approved quality)sheet (6 mm thick) work (excluding the supporting framework) fitted and fixed with 9.5mm. dia. J or L hook-bolt and nuts, limpet and bitumen washers and putty with 150 mm end lap & one corrugation minimum side lap complete. (Payment should be made on area of finished work)(a) In Roof |
| 53 | Asbestos ridging (with standard lap) fitted and fixed withnecessary hook, bolts, nuts, washers, etc. complete.(a) Close fitting adjustable type |
| 54 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. |
| 55 | Polishing only of old marble or terrazo work with oxalic acid powder using 33 gms/ sq.m. by manual labour / machinewhere necessary. |
| 56 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). |
| 57 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall beconsidered for payment] |
| 58 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge.b) 25 mm thick |
| 59 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excludingcost of chipping over concrete surface]i) With 1:6 cement mortar |
| 60 | (c) 15 mm thick plaster |
| 61 | (ii) With 1:4 cement mortar |
| 62 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.mOutside dado |
| 63 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.In Ground Floor: |
| 64 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. |
| 65 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two Coats |
| 66 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 67 | (b) Priming one coat on timber or plastered surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 68 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : |
| 69 | (b) On steel or other metal surface : |
| 70 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes: |
| 71 | B) UPVC Fittings: |
| 72 | d) Shoe |
| 73 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately)(A) For Exposed Work(a)(ii) 15 mm dia. medium quality |
| 74 | (c)(ii) 25 mm dia. medium quality |
| 75 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).(vii) 25 mm dia |
| 76 | Cleaning silt of inspection pit. |
| 77 | Supplying, fitting and fixing soap holder.(a) PTMT (Prayag or equivalent) |
| 78 | Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass(iii) 25 mm dia. and 750 mm long |
| 79 | Supplying, fitting and fixing bib cock or stop cock.(a) (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 80 | (b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 81 | (d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). |
| 82 | (g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm.(i) 15 mm |
| 83 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(v) 900 mm long |
| 84 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992A) (i) Single Socketed 3 Meter Length(b) 110 mm |
| 85 | (B) Fittings(ii) Plain Tee(b) 110 mm |
| 86 | (iii) Door Tee(b) 110 mm |
| 87 | x) Bend 87.5º(b) 110 mm |
| 88 | xi) Door Bend (T.S.)(b) 110 mm |
| 89 | xv) Vent Cowl(b) 110 mm |
| 90 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the totalpipeline including specials.(A) Above ground(ii) 110 mm dia. |
| 91 | Add GST (SGST @ 9% + CGST @9%) |
| 92 | Add Labour Welfare Cess @ 1% Please Enable Macros to View BoQ information |