| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required (DSR 1.8) |
| 2 | Group C (DSR 1.8.3) |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required (DSR 1.15) |
| 4 | Group C (DSR 1.15.3) |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (DSR 1.17) |
| 6 | 3 x 2.5 sq. mm (DSR 1.17.12) |
| 7 | 3 x 4 sq. mm (DSR 1.17.21) |
| 8 | 3 x 6 sq. mm (DSR 1.17.30) |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in urface/recess including cutting the wall and making good the same in case of recessed conduit as required (DSR 1.21) |
| 10 | 25mm (DSR 1.21.2) |
| 11 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required (DSR 1.22) |
| 12 | 75 mm X 75 mm X 60 mm deep (DSR 1.22.1) |
| 13 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (DSR 1.23) |
| 14 | 5/6 A switch (DSR 1.23.1) |
| 15 | 3 pin 5/6 A socket outlet (DSR 1.23.4) |
| 16 | 6 pin 15/16 A socket outlet (DSR 1.23.5) |
| 17 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required (DSR 1.29) |
| 18 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required (DSR 1.30) |
| 19 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required (DSR 1.55) |
| 20 | Group C (DSR 1.55.3) |
| 21 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (DSR 2.3) |
| 22 | 6 way , Double door (DSR 2.3.1) |
| 23 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (DSR 2.4) |
| 24 | 6 way (4 + 18), Double door (DSR 2.4.2) |
| 25 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR 2.10) |
| 26 | Single pole (DSR 2.10.1) |
| 27 | Double pole (DSR 2.10.3) |
| 28 | Triple Pole (DSR 2.10.4) |
| 29 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. (DSR 2.16) |
| 30 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (DSR 4.1) |
| 31 | 100 mm width X 50 mm depth X 1.6 mm thickness (DSR 4.1.1) |
| 32 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required (DSR 5.4) |
| 33 | Providing and fixing 6 SWG dia G.I. wire on surface or in recessbfor loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required (DSR 5.18) |
| 34 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) (DSR 8.7) |
| 35 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byE.I.C as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 36 | 36 watt (DSR 8.7.4) |
| 37 | Supplying, drawing, Installation, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA- 568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL. (DSR 39.18) |
| 38 | 1 run of cable (DSR 39.18.1) |
| 39 | Providing, fixing, testing & commissioning of 63 amp MCB TPN, 10kA, 'C' curve in the existing distribution board, complete in all respect to the entire satisfaction of engineer in-charge. (Ref N.S.) |
| 40 | Supply and laying of XLPE insulated PVC inner sheathed aluminum conductor Un-Armoured (3.5 core) cable of size 25 sqmm on the existing cable tray complete in all respect to the entire satisfaction of theE.I.C (Ref N.S.) |
| 41 | Fabrication and Installation of Adopter box made out of M.S Sheet duly painted with powdered coated paint after applying a priming coat of approved steel primer including cutting, hoisting, fixing in position of in any height including lead & lift complete in all respect to the entire satisfaction of theE.I.C. (Ref N.S.) |
| 42 | Providing, Installation, Testing and Commissioning of 1200 mm sweep, BEE 1 star rated (min), ceiling fan, double ball bearing, 100% copper wound motor with 3 nos. blades, down rod as per site requirement, 2 nos. canopies, shackle kit, safety rope, Power Factor not less than 0.9, Air delivery minimum 210 Cum/Min, THD less than 10%, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Ref N.S.) |
| 43 | Supplying and fixing 100W socket type 5 step fan regulator on existing plate with all petty materials complete in all respect to the entire satisfaction of theE.I.C. (Ref N.S.) |
| 44 | Dismantling and re-installation of Split Airconditioner. The job includes dismantling the air-conditioner's indoor and outdoor units after making necessary arrangement for restoration of gas and re-installation of same including all petty material. The job also includes testing of air-condioner after re-installation complete the job in all respect to the entire satisfaction of the E.I.C. (Ref N.S.) |
| 45 | Providing, fixing, testing & commissioning of 22 Guage soft hard copper piping 1/2\\" & 1/4\\" or as per original manufacture of AC Size for flare connection (liquid line & gas pipe) between indoor & outdoor units alongwith 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall, RCC wall & repairing of original condition as per site requirement, the rate per metre includes cost of 1 metre each of both 1/2\\" & 1/4\\" with insulation and other works etc. (Ref N.S.) |
| 46 | Supply and Installation of PVC rigid drain of 3/4\\" including cost of clamping and chasing through walls and making good the same in original condition complete in all respects from indoor unit to disposal point as directed by E.I.C. (Ref N.S.) |
| 47 | Fabrication and Erection of \\"D\\" Type Fan Hook. The Fan Hook should be fabricated with M.S bar 1/2\\" mounted on M.S Clamp having provision of 4 Nos Fasteners. The fan hook should be painted white in color after applying primer and should be installed at site with 4 Nos fastners complete in all respect to the entire satisfaction of theE.I.C. (Ref N.S.) |
| 48 | Shifting of UPS and battery bank including dismantling of battery bank, leads etc and reinstalling the same after shifting, testing, commissioning complete in all repect to the entire satisfaction of the E.I.C (Ref N.S.) |
| 49 | Supply and Installation of UPVC Trunking system 100mm x 50mm including petty material complete in all respect to the entire satisfaction of theE.I.C. (Ref N.S.) Please Enable Macros to View BoQ information |