| 1 | Hostel Repair Work |
| 2 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 3 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 4 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 5 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 7 | 12 mm cement plaster :1:6 (1 cement : 6 coarse sand) |
| 8 | M.S Z section window |
| 9 | Dismentaling of old Damage Angle Door |
| 10 | M.S. Angle Door |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 12 | Providing and fixing Oxidized door fittings |
| 13 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 25mm to40 mm |
| 14 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 15 | vProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15mmø nominal bore |
| 16 | vProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20mmø nominal bore |
| 17 | vProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 25mmø nominal bore |
| 18 | Dismenting of wash hand basin i/c fitting . |
| 19 | Dismenting of WC.Pan i/c fitting . |
| 20 | supply & fitting of wash hand basin i/c fitting . |
| 21 | supply & fitting of WC.Pan i/c fitting . |
| 22 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern. |
| 23 | supply & fitting of Bib cock,piller cock , angle cock i/c fitting . L. Boddy bib cock |
| 24 | supply & fitting of Bib cock,piller cock , angle cock i/c fitting . S. Boddy bib cock |
| 25 | Angle Cock |
| 26 | Piller Cock |
| 27 | Nhani trap 75mm to 100mm |
| 28 | uPVC blind pipe 100 mm dia as per IS |
| 29 | Supply and fixing of 6mm thick china white Glazed tile 200X100mm in dado/skirting laid in 1:3 cement : sand mortar finished with cement slurry jointing 7 polishing complete including Supply of all materials labour and T&P etc. required for proper completion of the work. |
| 30 | Providing and laying of Mat finished tile flooring over 25mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid jointed with white cement slurry including rubbing and polishing complete. |
| 31 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm |
| 32 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 33 | Cleaning Of Saptik tank , main hole chamber & Sunkan portion |
| 34 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. coupler 110mm |
| 35 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5 degree |
| 36 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door |
| 37 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without door |
| 38 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 40 mm dia |
| 39 | Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within50 metres lead. |
| 40 | Providing & fixing fly proof wire gauze to windows, clerestory windows &doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wireand 1.4 mm aperture on both sides |
| 41 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 42 | Cynder Filling |
| 43 | Disposal of malba |
| 44 | Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 45 | Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. |
| 46 | Locker For Almari Cop board |
| 47 | Hole fastener For Almari G.I sheet Cop board |
| 48 | providing and laying in cemrmt concrete 1:4:8 (1 cement 4 coarse sand 4 graded stone aggregate 40 mm nominal size) and curing complete, inlcuding cost if form-work . In foundation and floors. |
| 49 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 50 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 51 | Dismaintiling of exisitng brick work G.F & F.F Wall WC & Bath |
| 52 | R.C.C work in 1:1½3 in C:C/S:S/G over door lintel |
| 53 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.White Agaria Marble Stone |
| 54 | Providing and laying \\"brick coba\\" 120 mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. |
| 55 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shapewherever required. |
| 56 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 57 | Construction of Boundry Wall |
| 58 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 60 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 61 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 62 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessarybolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 63 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge |
| 64 | Construction of Guard Room |
| 65 | Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per technical specification clause 201 |
| 66 | Providing Layout & centerline for building i/c all labour T&P complete |
| 67 | Excavation in foundation in ordinary soil (loamclay or sand) including lift up to 1.5m and lead up to 30m. and including filling watering and ramming of excavated earth into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth ad directed by the Engineer in charge up to a distance of 30m. from the foundation trenches including all T&P phowarah and basket etc. complete. |
| 68 | Cement concrete with 4 cm gauge approved stone ballast, approved coarse sand and cement in the proportion 8:4:1 including supply of all materials, labour and T & P etc. required for proper completion of the work. |
| 69 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete |
| 70 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km.(5 miles) from the site of work and including watering, dressing etc. Rate to include cost of alt materials, labour and T&P etc. required for proper completion of the work. (Analysis Rate) |
| 71 | M-150 Brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all material, labour and tools and plants ect. Require for proper completion of work. (303+3 |
| 72 | M-150 Brick work in 1:6 cement and coarse sand mortar in super structure all material, labour and tools and plants ect. Require for proper completion of work. |
| 73 | for Parapet and 4.5\\" wall 1:4 cement abd coarse sand |
| 74 | R.C.C work with cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding its fixing and binding the same with 24 B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including supply of all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. Plinth bend |
| 75 | R.C.C work with cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding its fixing and binding the same with 24 B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including supply of all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. Lintel bend |
| 76 | R.C.C work with cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding its fixing and binding the same with 24 B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including supply of all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. Sunshade |
| 77 | R.C.C work with cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding its fixing and binding the same with 24 B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including supply of all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. Slab |
| 78 | Providing & fixing of MS sheet door shutter with chaukhat size 1.05x2.10mtr |
| 79 | Providing & fixing of MS Z-section window with MS sheet shutter & grill of 10mm sqbar size 1.20x1.20 mtr & for ventilation of size 0.60x0.45 |
| 80 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastege. bend hooks and authorized.(504) for beam |
| 81 | 2cm (3/4\\") thick cement plaster in dedo or skirting in 1:2 consisting of one part of cement and 2 parts of approved coarse sand laid in panels, finished with 3 mm (1/8\\") floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials, labour and T&P etc. required for proper completion of the work. (597) |
| 82 | 12mm. thick plaster with cement mortar consisting of 1 part cement and 6 part of approved coarse sand. minimum thickness not to be less than 10mm including supply of all material, labour and T&P etc. required for proper completion of the work. (583) |
| 83 | 12/15mm thick inside wall plaster 1:6 cement : coarse sand mortar (584 + 596) |
| 84 | 40mm thick without base CC floor 1:2:4 cement,coarse sand&20mm stone grit |
| 85 | Finishing walls with acrylic smooth exterior paint of required shade (13.111) |
| 86 | Distempering with 1st quality acrylic distemper (read made) having VOC content less than 50 gm per ltr of approved manufacture and of required shade and colour complete as per manufacture's specification. (13.108) |
| 87 | Painting with synthetic enamal paint of approved brand and manufacture of required colour to give an shade (13.92) i/c one coat primer |
| 88 | Construction of Boundary Wall with Concertina coil fencing |
| 89 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m |
| 90 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 91 | providing and laying in cemrmt concrete 1:4:8 (1 cement 4 coarse sand 4 graded stone aggregate 40 mm nominal size) and curing complete, inlcuding cost if form-work . In foundation and floors. |
| 92 | R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all materials, labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work. |
| 93 | R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all materials, labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work. |
| 94 | Mild steel or iron in plain work such as reinforced concrete wrought to required same as necessary including bending for proper completion of the work. |
| 95 | Coursed rubble masonry (first sort) with hard stone in foundation andplinth with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 96 | M 150 brick work in 1:6 cement and Coarse sand of mortor in s/s in one brick thick wall including supply of all materials , labours and T&P etc. required for proper completion of the work. |
| 97 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources |
| 98 | M 150 brick work in 1:6 cement and Coarse sand of mortor in s/s in one brick thick wall including supply of all materials , labours and T&P etc. required for proper completion of the work. |
| 99 | 15 mm thick wall plaster in 1:6 cement c/sand mortar with n.c.f.including all material labour t&p and scaffolding |
| 100 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 101 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 102 | Centering and shuttering including strutting, propping etc. and removalof form for Foundations, footings, bases of columns, etc. for mass concrete |
| 103 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 104 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of nserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 105 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Please Enable Macros to View BoQ information |