| 1 | 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 2 | 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 4 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 5 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 7 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 9 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 10 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 13 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 14 | 5.9.7 Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 15 | 2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 16 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 17 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 18 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 19 | 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 Sal wood |
| 20 | 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters |
| 21 | 9.145 Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineerin-charge. |
| 22 | 9.144 Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer's specification and direction of Engineer-in-charge. |
| 23 | 11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 24 | 13.1 12 mm cement plaster of mix :13.1.1 1:4 (1 cement: 4 fine sand) |
| 25 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 26 | 13.3 20 mm cement plaster of mix :13.3.1 1:4 (1 cement: 4 fine sand) |
| 27 | 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.1 Fixed to steel windows by welding |
| 28 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 29 | 13.50 Applying priming coat:13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 30 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 31 | 13.50 Applying priming coat:13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 32 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 33 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 34 | 13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :13.43.1 Water thinnable cement primer |
| 35 | 13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 36 | 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :9.96.1 300x16 mm |
| 37 | 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.97.1 300x10 mm |
| 38 | 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :9.100.1 125 mm |
| 39 | 9.107 Providing and fixing PTMT Butt hinges with necessary screws etc. complete.9.107.1 75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 34 gms |
| 40 | ELECTRIFICATIONSub Head-I (Wiring)1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(a) Grou A |
| 41 | 1.2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit 2 way modular switch, modular plate suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 42 | 1.3 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq, mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 43 | 1.4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(a) 2 X 1.5 sq mm + 1 X 1.5 sq. mm earth wire |
| 44 | (b) 2 X 6 sq.mm + 1 X 6 sq, mm earth wire |
| 45 | (c) 4 X 16 sq.mm + 2 X 6 sq.mm earth wire |
| 46 | 1.5 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a) 3 x 1.5 sq.mm |
| 47 | (b) 6 x 1.5 sq. mm |
| 48 | (c) 6x4 sq.mm |
| 49 | 1.6 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wail and making good the same in case of recessed conduit as required. a) 20 mm |
| 50 | b) 25 mm |
| 51 | 1.8 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required (For light plugs to be used in non residential buildings). |
| 52 | 1.9 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc, as required |
| 53 | 1.12 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 25 A socket outlet |
| 54 | Sub Head-II (MCB & DB's)2.2 Supplying and fixing following way, horizontal type three pole and neutral sheet steel, MCB distribution board, 215 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)a) 4 way (4+12), Double door |
| 55 | b) 8 way (4+24) Double door |
| 56 | 2.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole |
| 57 | 2.5 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 amps |
| 58 | 2.6 Supplying and fixing following rating, four pole 415 volts isolator in the existing MCB DB complete With connections, testing and commissioning etc. as required. a) 63 amps |
| 59 | 2.8 Supplying and fixing following rating, 415 V. 10 kA, \\"C\\" curve miniature circuit breaker suitable for inductive load of following poles in the-existing MCB DB complete with connections, testing and commissioning etc. as required.a) 40/63 A TP |
| 60 | Sub Head-III (Fan, Fittings and Fixtures)3.2 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 61 | 3.3 Supplying, of 1200 mm sweep, BEE five star rated ceiling fan with Brush Less Direct Current (BLDC motor) not less than 32W class of insulation B. 3 Nos blade, 30 cm long down road, 2 Nos of canopies, shackle kit safety rope, copper winding power factor not less than 0.9 service value. (CMM/W) minimum 6.85 air delivery minimum 215cmm 350 rpm (Tolerance as per 15374-2019), THD less than 10% remote or electronic regulator for speed control and all remaining accessories i/c safety pin, nut bolts washer, temperature rise=75 degree C(max). insulation resistance more than 2mega ohm, suitable for 230V, 50 Hz AC supply, earthing etc. complete as required. |
| 62 | 3.7 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) Upto 450mm sweep |
| 63 | 3.11 Supplying, Installation, testing and commissioning of surface mounted square/round shape LED downlighter having suitable housing Lumen efficacy ≥100 lm/watt, System Lumen output ≥1200 lm, CRI ≥80, Power factor ≥0.9 having suitable diffuser and CCT in between 4000K to 6500 K (i/c both Limits) complete with all accessories etc. directly on ceiling/wall including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc, as required, |
| 64 | Sub Head-IV (Service Connection)4.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required, a) Upto 35 sq.mm |
| 65 | b) Above 35 ssq.mm and upto 95 sq.mm |
| 66 | 4.2 Supplying of one number XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade with ISI marked (IS 7098 (Part - l) / 1988 with amendment up to date) following sizes. a) 3½ X 35 sq.mm |
| 67 | b) 3½ X 95 sq.mm |
| 68 | 4.3 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 x 35 sq.mm (32 mm) |
| 69 | b) 3½ X 95 sq.mm (45mm) |
| 70 | 4.4 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 71 | 4.5 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required |
| 72 | 4.6 Supplying and fixing ot light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 73 | Sub Head-V (Lighting Conductor and earthing)5.1 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I base plate including holes etc, complete as required. |
| 74 | 5.2 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 75 | 5.3 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required, (For vertical run) |
| 76 | 5.4 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strips 125 mm long, with 4 nos. of G.I. bolts, nuts chuck nuts and spring washers etc. com fete as required |
| 77 | 5.6 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 78 | 5.7 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
| 79 | 5.8 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 80 | 5.9 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with C.I. thimble excavation and re-filling as required |
| 81 | 5.10 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 82 | SANITARY INSTALLATION & WATER SUPPLY17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :17.2.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 83 | 17.4 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.4.2 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
| 84 | 17.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern |
| 85 | 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.8 White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers |
| 86 | 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.17.28.1 Semi rigid pipe17.28.1.2 40 mm dia |
| 87 | 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 88 | 17.34 Providing and fixing toilet paper holder :17.34.2 Vitreous china |
| 89 | 17.35 Providing and fixing soil, waste and vent pipes :17.35.1 100 mm dia17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 |
| 90 | 17.60 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :17.60.1 100 mm inlet and 100 mm outlet 17.60.1.1 Sand cast iron S&S as per IS: 3989 |
| 91 | 17.61 Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :17.61.1 100 mm dia |
| 92 | 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 93 | 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 94 | 18.15 Providing and fixing brass bib cock of approved quality :18.15.2 20 mm nominal bore |
| 95 | 18.16 Providing and fixing brass stop cock of approved quality :18.16.2 20 mm nominal bore |
| 96 | 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work18.9.1 15 mm nominal outer dia Pipes |
| 97 | 18.9.2 20 mm nominal outer dia Pipes |
| 98 | 18.9.3 25 mm nominal outer dia Pipes |
| 99 | 18.9.4 32 mm nominal outer dia Pipes |
| 100 | 18.9.5 40 mm nominal outer dia Pipes |
| 101 | 18.10 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall18.10.1 15 mm dia nominal bore |
| 102 | 18.12 Providing and fixing G.I. pipes complete with G.I. fittings Internal work- Exposed on wall18.12.2 20mm dia nominal bore |
| 103 | 18.12.4 32mm dia nominal bore |
| 104 | 18.13 Providing and fixing gun metal non-return valve of approved quality (screwed end):18.13.1 20 to 40 mm nominal bore |
| 105 | 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :18.17.1A 20 mm nominal bore |
| 106 | 18.17.2 32 mm nominal bore. |
| 107 | 18.17.3 40 mm nominal bore |
| 108 | 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) :18.19.3 40 mm nominal bore18.19.3.1 Horizontal |
| 109 | 18.19.3.2 Vertical |
| 110 | 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions :18.21.1 30 cm length18.21.1.1 15 mm nominal bore |
| 111 | 18.21.1.2 20 mm nominal bore |
| 112 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 113 | SEPTIC TANK2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 114 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 115 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 116 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 117 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 118 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 119 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 120 | 5.9.13 Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 121 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 122 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 123 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 124 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 125 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick Please Enable Macros to View BoQ information |