| Sl. No. | Item Description |
| 1 | Providing and laying in position ready mixed M25 grade concrete having compressive strength at 28 days test not lessthan 250kg/sq.cm for reinforced cement concrete work using cement content as per approved design mix etc including Rigid & smooth centering and shuttering. |
| 2 | R.C.C Beam & Coloum |
| 3 | First floor |
| 4 | Terrace Floor |
| 5 | Lintel |
| 6 | First floor |
| 7 | Terrace Floor |
| 8 | R.C.C Stair |
| 9 | First floor |
| 10 | Chaja |
| 11 | First floor |
| 12 | Roof slab, Landing, Balcony, |
| 13 | First floor |
| 14 | Terrace Floor |
| 15 | Cutting, straightening coiled or bend up HYSD/TMT Reinforcement bars welding or jointing if necessary, bending, tying the grills as required for R.C.C works etc winding wire extra |
| 16 | First floor |
| 17 | Terrace Floor |
| 18 | BRICK WORK |
| 19 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 23c.m x 11 c.m x 8 c.m in superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, stacking, loading, unloading, royalties , all taxes ,cost of all labour, Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 20 | First floor |
| 21 | Terrace Floor |
| 22 | PLASTERING & PAINTING |
| 23 | Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (along with providing grooves wherever necessary) including watering and curing, rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. as directed by the Engineer-in- charge. |
| 24 | First floor |
| 25 | Terrace floor |
| 26 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (along with providing grooves wherever necessary)including watering and curing, rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. as directed by the Engineer-in- charge. |
| 27 | First floor |
| 28 | Terrace floor |
| 29 | Finishing Wall Surface of wall with cement based wall putty two coats (water based )of approved and finished smooth and even surface to received painting including cost of scafolding, stagaing charges with cost of all material and takes labour T&P etc complete. |
| 30 | Ground Floor |
| 31 | First floor |
| 32 | Terrace floor |
| 33 | Providing and applying on New surface two coat of primer (water based) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging |
| 34 | Ground Floor |
| 35 | First floor |
| 36 | Terrace floor |
| 37 | Providing and applying 2 coats with 100% acrylic emulsion paint (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete. |
| 38 | Ground Floor |
| 39 | Supplying and painting of internal walls and ceiling with two or more coats of plastic emulsion paint on New surface which includes a coat of primer (water based) all complete. The shade and brand to be of approved brand & shade over the surfaces including preparation of surface, with cost of all materials, labour, conveyance taxes of all materials,scaffolding etc., as per the direction of the Engineer-in-charge. |
| 40 | Ground Floor |
| 41 | First floor |
| 42 | Terrace floor |
| 43 | Painting with synthetic enamel paint over a coat of primer of approved colour, shade and brand on New wood work /steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete. |
| 44 | First floor |
| 45 | FLOORING |
| 46 | Supplying, fitting and fixing vitrified tile in floors of size 600mm x 600mm of approved make conforming to I.S 13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 sand )and filling joints with white cement of approved quality including cost of all materials, labour T&P etc.required for the work all complete as per direction of engineer in charge. |
| 47 | First floor |
| 48 | Fixing vitrified tiles (600mm x 600mm) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per direction of engineer in charge. |
| 49 | First floor |
| 50 | Fixing Granite tiles (19MM thk) in floors treads or steps and landing on 25mm thick bed of cement mortar 1 :1 (1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades on the tiles etc. complete as per direction of engineer in charge. |
| 51 | First floor |
| 52 | DOOR & WINDOW |
| 53 | Supplying, fitting, fixing of factory made single leaf rigid F.R.P. composite door shutter of 32 mm thick, laminated with G.P.P. skins with wood grain finished etc as per direction of Engineer-in-charge. |
| 54 | Tata Pravesh General Steel Finish/ wood finish Doors:Supply and fixing of 46mm thick GI doors and frame conforming to IS 277 galvanised plain skin passed sheets of 0.8mm in shutter and 12mm in frame with minimum 120 gsm zinc coating with profile dimension of 100mm x 58mm. Frame filled with Polyurethane foam and shutter duly filled with Honeycomb and both coated with minimum 60 microns of RAL powder coating. Accessories will be provided with doors. |
| 55 | Supplying, fitting, fixing up window (sliding type) made up aluminum Section 9778 as windows frame, section No. 4095, 4096 and 9777, 3994 as shutter frame with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-in-charge. Total cost of Sliding Three Track Aluminum window with mosquitonet |
| 56 | STEEL WORK |
| 57 | Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing including cost, conveyance, loading, unloading, stacking, royalties and taxes of all materials, cost of all Labour, Labour cess ,Sundries, T&P required for the work etc. complete as per the direction of Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.) |
| 58 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr.C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification ,buffing, polishing etc with cost, conveyance,taxes of all materials, labour, T & P etc. required for the complete in all respect. |
| 59 | Grading plaster |
| 60 | 2.0 cm thick grading Plaster (1:4) on roof slab including all cost, conveyance, royalty & taxes etc.comp.to work site for new work as per the specification approved by the department & direction of E.I.C |
| 61 | Terrace Floor |
| 62 | Class lite , microlook M15, Armstrong false ceiling : Providing and fixing of CL-1 Exposed Tee Grid T-Bar Modular Ceiling 600x600mm.Armstrong ultimavector with peakform prelude 15/16\\"Installation shall be as per Manufacturers specifications(Armstrong).Comprises of 16 mm thk Texture of tile- Classiclite, edge oftile-Microlook, framing with suprafine M15 midrange Armstrong #main and cross tee T-32*15 *1.5 mm ( height*flange width of TEE*thickness)galvanized section ,exposed tee will be powder coated and with ARMSTRONG make suspension system i.e. Anchor fastener, vertical hanger, hook clip etcas described. To be laid at all heights cut to all shapes and sizes and in the required grid pattern with necessary support from the civil ceiling as per architects design, details and specifications. Including necessary light points / AC grills and other opening cuttings in the ceiling tiles with all necessary scaffolding labour and other materials complete. The work shall include wastages, labour, all lead and lifts atall levels, loading and un loading, transportation and other incidental charges etc., complete as directed by the Engineer-in-charge. |
| 63 | Design fabrication and installation this includes the structural frames and the installation the entire glazing system. |
| 64 | Supplying, fitting, fixing Texture Paint characterized by a partially smoothed and partially textured appearance. |
| 65 | Providing and Fixing GRC Jali of approved design and finished, the technical specification for density strength, and color ,including all necessary labor, materials and support for installation . |
| 66 | INTERNAL PH WORKS |
| 67 | Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain Indian Pan water closet of size 23\\" of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge. |
| 68 | Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain flat back urinal pan of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge including marble partition in between urinals. |
| 69 | Supplying all materials, labour, T&P and fixing standard sized shower (bath shower) of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 70 | Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain wash basin of size 450mm x 300mmof approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in- charge. |
| 71 | Supplying all materials, labour, T&P and fixing standard 15mm sized pillar cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 72 | Supplying all materials, labour, T&P and fixing standard sized Long body 15mm dia CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 73 | Supplying all materials, labour, T&P and fixing standard sized two way CP Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 74 | Supplying all materials, labour, T&P and fixing standard sized shower (Health Faucet) of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in- charge. |
| 75 | Supplying all materials, labour, T&P and fixing standard sized CP soap Dish holder of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 76 | Providing and fixing circular type stainless steel jalli (grating) with hole for floor /nahani trap etc complete as per PH specification and direction of the engineer in charge |
| 77 | Fixing 600x450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with Chromium Plated brass screws and washers complete as per specification and direction of the Engineer in charge |
| 78 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge |
| 79 | Supplying all materials, labour, T&P and fittings and fixing of Poly Propelene white double layer water storage Tank of approved make confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc including hoisting upto terrace level and placing the tank to the required position etc all complete as per PH specification and direction of Engineer-in-charge. (To provided with brick masonary guard walls which will be paid separately) |
| 80 | 2000 ltr |
| 81 | Supplying all materials, labours, T&P and fitting and fixing of the following size of CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge. |
| 82 | 15 mm dia |
| 83 | 20 mm dia |
| 84 | 25 mm dia |
| 85 | 32 mm dia |
| 86 | 40mm dia |
| 87 | 50 mm dia |
| 88 | Providing all materials, labour, Fitting & fixing of CPVC Ball Valve with CTS socket. Make : Prince) |
| 89 | 25mm Dia |
| 90 | 32mm Dia |
| 91 | 40mm dia |
| 92 | 50mm dia |
| 93 | Supplying all materials,labours,T&P for cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. |
| 94 | Supplying all materials,labours,T&P for cutting holes through existing RCC floors & roofs including making good the damages for taking GI pipes and fittings/PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. |
| 95 | Supplyng all materials, labour, T&P for construction of brick masonary Gulley trap chamber of size300mm x 300mm with CI gulley trap, by Fly ash brick masonry in CM (1:4), CP (1:6) with 150mm x 150mm CI grating including labour and materials for fitting and fixing 100mm dia square mouth CI gully trap with supply of all jointing materials and encasing the gully trap with a block of CC (1:4:8) with 25mm size hard stone metal all complete with providing and fixing of 250mm x 250mm precast RCC cover slab including cost, conveyance, taxes of all materials to site complete as per the PH specification and direction of Engineer-in-charge. |
| 96 | Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of all materials, curing, conveyance of all materials etc. all complete excluding GST as per specification & direction of Engineer-in-charge. |
| 97 | External PH |
| 98 | Supplying all materials, labour, T&P, fitting & fixing of 50mm dia brass / GM Full way Valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and as per the direction of the EIC. |
| 99 | Supplying all materials, labours, T&P and fitting and fixing of the following size of CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge. |
| 100 | 50mm dia |
| 101 | Supplying all materials & labour, T&P and constructing brick masonary chamber for water sluice valve, single air valve & non return valve with Fly ash brick masonary in cement mortar (1:4) as per approved drawing and specification CC (1:4:8) with 4cm size hard granite metal on the bed, 12mm cement plaster (1:6) to inside and cement flush pointing (1:6) to outside surface with 100mm thick RCC M20 cover slab with 20mm hg chips using required quantity of tor steel, centring and shuttering to the slab and dismantling it after 31 days of casting, filling the outside cavity with excavated materials, watering, curing including cost, conveyance, taxes of all materials, labour charges for cutting, bending, binding and tying the grills in proper position etc all complete as per drawing, design and direction of Engineer-in- charge. |
| 102 | Chamber (0.75x0.75x0.7mtr) |
| 103 | Supplying all materials, labour, T&P and fitting and fixing of double air valve of 50mm Dia confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge. |
| 104 | Supply, installation, testing and commisioning of automatic star delta control panel suitable for 2 HP pumpset including MS box fitted with main switch ,contactor, single phasing preventer, timer, selector switch, voltmetre, ammeter etc and connection with motor inside the sump with suitable cable etc complete as per the Direction of Engineer-in-charge. (Excluding power supply)(MR) |
| 105 | Septic Tank |
| 106 | Earth work in excavation in Hard rock by mechanical means (Hydraullic excavator)/ manual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) inculding disposal of excavated earth up to 50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, T & P required for the work complete as directed by the Engineer- in- charge. |
| 107 | Earth work excavation beyond 1.50mtr depth |
| 108 | Extra for every additional lift of 1.5 m or part there of in excavation / banking excavated or stacked materials. |
| 109 | Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 110 | Providing and laying P.C.C[1:3:6] using 4cm size metal etc in foundation and floors using cement , 40 mm size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting ,lowering and laying concrete to the required level, ramming ,watering and curing etc |
| 111 | Providing and laying in position ready mixed M25 grade concrete having compressive strength at 28 days test not lessthan 250kg/sq.cm for reinforced cement concrete work using cement content as per approved design mix etc |
| 112 | Foundation |
| 113 | RCC Wall |
| 114 | Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as etc |
| 115 | Providing 12mm. thick cement plaster with cement mortar of mix (1:6) in all floors cement and with screened and washed sharp sand for mortar with neat cement punning finished smooth to brick/RCC walls after racking out the joints including watering and curing complete with cost, etc |
| 116 | Providing & applying cement punning over cement plaster |
| 117 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 118 | Soak Pit |
| 119 | Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and taxes of all materials, cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge. |
| 120 | Providing & laying cement concrete of prop. (1:4:8) in foundation bed and floors using 40mm nominal size down graded, screened, washed hard black crusher broken granite metal of approved quality & from approved quarry including laying in the layers not exceeding 100 mm thick, etc |
| 121 | Providing and laying in position ready mixed M25 grade concrete having compressive strength at 28 days test not lessthan 250kg/sq.cm for reinforced cement concrete work using cement content as per approved design mix etc |
| 122 | Foundation |
| 123 | Providing 12mm. thick cement plaster with cement mortar of mix (1:4) in all floors cement and with screened and washed sharp sand for mortar with neat cement punning finished smooth to brick/RCC walls after racking out the joints including watering and curing complete with cost, etc |
| 124 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 125 | Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B)(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including transportation & scaffolding etc. all complete as per specification excluding GST & direction of the Engineer-in-charge. |
| 126 | Pipe 110mm dia |
| 127 | 110mmx110mm 'P' Trap (Make:Astral) |
| 128 | 110mmx87.5º Plain bend |
| 129 | 110mmx87.5º Door bend |
| 130 | 110mmx45º Plain bend |
| 131 | 110mm dia single 'Y' withoutdoor |
| 132 | 110mm WC connector/Bend with lip ring |
| 133 | 110mm Socket plug |
| 134 | 110mm Pushfit Coupler |
| 135 | Upvc Tee (150 x 150 x 150)mm |
| 136 | Upvc Elbow |
| 137 | Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 300 mm x 300 mm OR 600 mm x600 mm, confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp etc |
| 138 | First floor |
| 139 | Supplying, fitting and fixing of ceramic glazed wall Tiles in skirting dado,risers of step and wall using special plain / printed series Ceramic wall Tile of premium grade ( having minimum thickness 6.5 mm to 6.7 mm & size 300 mm x 300 mm OR 600mm x300 mm, |
| 140 | First floor |
| 141 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 142 | INTERNAL ELECTRIFICATION |
| 143 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/ HAVELLS/RR KABLE/KEI with 20 mm dia PVC non metallic heavy duty conduit FRLS type ISI marked Make-AKG/BEC/Precision/Norpack 6A modular type ( flame retradant type) switch ISI marked Make-Schneider (Zencelo) /legrand( Myrius) /Panasonic (vision)/Eq. and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider (Zencelo) / legrand( Myrius) / Panasonic (vision)/Eq. of suitable size, modular box with 1.5 sq. Mm FRLSH PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. |
| 144 | Group-A. |
| 145 | Group-B. |
| 146 | Group-C. |
| 147 | Subsequent point of group control |
| 148 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider (Zencelo) / legrand( Myrius) /Panasonic (vision)/Eq. (Maximum 02 nos point in one circuit). |
| 149 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) /Eq. (Maximum 02 nos point in one circuit). |
| 150 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision)/Eq. (For equipment power). |
| 151 | Recess wiring for circuit/submain wiring with the following mentioned size PVC FRLSH / LSZH insulated, copper conductor, single core cable Make- Finolex / Anchor / Polycab / HAVELLS / RR KABLE / KEI in recessed PVC conduit Heavy duty FRLS of mentioned size Make-AKG / BEC / Precision/Norpak as required as per direction of Engg.-in-Charge. |
| 152 | a) 2 x 2.5mm2 for inverter wiring |
| 153 | b) 2 x 1.5mm2 + 1 x 1.5mm2 |
| 154 | c) 2 x 2.5mm2 + 1 x 1.5mm2 |
| 155 | d) 2 x 4mm 2 + 1 x 1.5mm2 |
| 156 | e) 4 x 6mm2 + 2 x 2.5mm2 |
| 157 | f) 4 x 10mm2 + 2 x 4 mm2 |
| 158 | MAIN PANEL |
| 159 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge.In commer- 01 number of 100 Amps 4P MCCB,25KA with 100A 4P changeover switch (Icu=100%Ics) with shunt trip.with auxuliary Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator Out going- .(i) 63A FP MCCB 16KA- 06 Nos. (ii) 63A 4P MCB-03 Nos. (iii) 40A 2P MCB- 03 Nos Instrument- (i) 06 (03 main +03 DG) numbers phase indicating lamp with HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage, current, frequency,PF,THD indication (iii) 01 set of 40KA TYPE2+1 4P SPD along with 63A 4P MCB.Make of switchgear-Legrand / Schneider / Siemens / ABB / Havells / C&S / Hagar / L&T |
| 160 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FRLSHPVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. |
| 161 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(but with out MCB/ RCCB/ Isolator)(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) |
| 162 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 163 | Supplying and fixing 6-32Amps DP 240 volts, MCB Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 164 | Supplying and fixing 40Amps 4P 415 volts MCB Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 165 | Supplying and fixing 40Amps 4P 415 volts RCCB 30 mA Make-LEGRAND/ Siemens/ Schneider /Equievalant model of Havells/C& S/ ABB/Hagar/L&T in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 166 | Fitting & Fixtures |
| 167 | S/F. of Superior type Call bell with push & flexible cord. |
| 168 | S/F of BLDC Fan regulator.Make:Legrand / L&T / Havells / Anchor / Eq |
| 169 | S/F of 400 mm sweep wall Fan Make:Usha / Almonard / Crompton / Havells / Bajaj / Halonix |
| 170 | S/F. of 250mm Sweep Exhaust fans of ISI marked.(Make:-Havells Thrill Air DX / Usha / Crompton / Orient / Bajaj / Halonix/equivalent) |
| 171 | S/F. of 90Wt. With efficacy of 120lm/W Light emitting diode Street light fittings of Havells/ Crompton/ Bajaj/Philips/Halonix /Panasonic/ Wipro/LT |
| 172 | S/F. of 120Wt. With efficacy of 120lm/W Light emitting diode Street light fittings of Havells/ Crompton/ Bajaj/Philips/Halonix /Panasonic/ Wipro/LT |
| 173 | Ceiling mounted 15W LED of Recessed/Surface light. |
| 174 | Ceiling/ Wall mounted type BULK HEAD Luminaire with 10W LED Lamp. |
| 175 | Ceiling mounted 600mm X 600mm 36W Surface/recessed LED fixture |
| 176 | Supply and fixing 3 pin, 5A ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 177 | Lightning Protection |
| 178 | Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Cape |
| 179 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Cape |
| 180 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/Cape |
| 181 | Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Cape |
| 182 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO / Dehn / Cape |
| 183 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/Cape |
| 184 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/Cape |
| 185 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/Cape |
| 186 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO / Dehn / Cape |
| 187 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/Cape |
| 188 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/Cape |
| 189 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/Cape |
| 190 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO / Dehn / Cape |
| 191 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/Cape |
| 192 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO / Dehn / Cape |
| 193 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/Cape |
| 194 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO / Dehn / Cape |
| 195 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/Cape |
| 196 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 197 | CABLES |
| 198 | Providing,fixing and laying of 50 mm dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching (75 mm depth) and refilling as per direction of Engg.-in-Charge. |
| 199 | Supply of 35 sq.mm 3 & 1/2 core XLPE Al.Armoured Cable of ISI marked.(Make -Polycab / Havells / KEI / RR Kable / Finolex / Gloster) |
| 200 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
| 201 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required. |
| 202 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. (3.5C x 35 sq.mm) |
| 203 | S/F of special earthing complete with 3mtr long 40 m dia G.I pipe , 600x600x3.15mm thick copper plate , charcoal , salt including excavation of earth and filling of loose soil upto ground level including all connection and masonary work. |
| 204 | Supplying and laying 25 mm x 5 mm CU earth strip ISI marked on surface or in recess for connection etc as required. |
| 205 | Supply and installation of Rubber Mats 8 mm thick |
| 206 | Fire Extinguishers |
| 207 | Supplying installation testing and commissioning of ABC type fire extinguishers of 6 kg capacity confirming to IS:14609 & ABC powder confirming IS:13849 presurized with Nitrozen Gas marked.including cost of all material & labour for all floors & service building etc. all complete. Make-KANEX/FIRE SHILD /SAFEX or equivalent |
| 208 | Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket for all floors & service building etc. as per direction of Engineer-in-charge.Make-KANEX/FIRE SHILD /SAFEX or equivalentor equivalent |
| 209 | Supplying, installation, testing and commissioning of Mechanical Foam type 9 litre capacity Fire Extinguisher, ISI marked, IS: 10204, containing 540 ml AFFF liquid ISI marked, IS: 4989 Part II and a polyurethane coated CO2 Gas Cartridge, ISI marked, IS: 4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket as per direction of Engineer-in-charge. |
| 210 | MISCELLANEOUS WORK : |
| 211 | Sand Buket as per IS Specicification |
| 212 | Buket Stand to Store 10 nos of Buket also having Aluminium sheet above the to prevent the stand from rain/sunst. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail