| 1 | M & L for preparation of old plastered surface of wall and applying one coat of white wash complete all as specified and directed. |
| 2 | M & L for preparation of old plastered surface of wall and applying two coat of white wash complete all as specified and directed. |
| 3 | M & L for preparation of old plastered surface of wall and applying one coat of cement base paint complete all as specified and directed. |
| 4 | M & L for complete removal of existing treatment of old plastered surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and directed. |
| 5 | M & L for preparation of old plastered surface of wall and applying one coat of oil emulsion distemper complete all as specified and directed. |
| 6 | M & L for preparation of old plastered surface of wall and applying two coat of oil emulsion distemper complete all as specified and directed. |
| 7 | M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed. |
| 8 | M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint (first quality) complete all as specified and directed. |
| 9 | M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed. |
| 10 | M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint (first quality) complete all as specified and directed. |
| 11 | M & L for writing building Nos, letters or figures (Block,Roman, Italic or Indian) on wall n exc. 30 cm height with synthetic enamel paint complete all as specified and directed . |
| 12 | Demolition of precast concrete block walling built in cement morter complete all as directed. |
| 13 | M&L for precast cement concrete block masonary walling type C-I 1:3:6 using 20mm graded aggregate with solid blocks, exc. 10 cm in width and setting in CM 1:6 complete. |
| 14 | M/L for PCC 1:2:4 type B1, using 20mm graded stone aggregated as in plinth band, lintel band, roof band , lintel bands ,copings and other similar bands etc all as directed by Engr-in-Charge at site. |
| 15 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 16 | M & L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 ,and finished even and smooth without using extra cement complete all as specified and directed. |
| 17 | M & L for rendering 15mm thick in cement plaster 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finishing even and smooth without using extra cement complete all as specified and directed. |
| 18 | M & L for preparation of New plastered surface of wall and applying two coat of oil emulsion distemper complete all as specified and directed. |
| 19 | M & L for complete removal of existing treatment of New plastered surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and directed. |
| 20 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for. |
| 21 | M &L for 25 mm thick PCC 1:4:8 type D2 (Using 12.5 mm graded stone aggregate) as in sub base in floors complete all as specified and directed by Engr-in-charge |
| 22 | M&L screed bed or bedding layer of morter 15 mm thick cement plaster 1:6 for laying floor finished to receive floor tiles/granite. |
| 23 | M & L for Virified Ceramic tiles Light shed 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 24 | M & L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed . |
| 25 | M & L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed . |
| 26 | M & L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed . |
| 27 | M&L for machine cut kota stone slab flooring 20-25mm thick mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 28 | M&L for machine Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed over 10 mm thick rendering in CM 1:6, complete all as specified and as directed. |
| 29 | Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges |
| 30 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises |
| 31 | M&L coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 350 x7mm / 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles on rendering 10mm thick in cement plaster 1:6 on concrete surface/block masonary/stone masonary or other surfaces complete all as specified and as directed.. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 32 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings |
| 33 | S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with coach screws and washers, in roof ,walls etc with grade of zinc coating 275. complete all as specified and as directed. |
| 34 | S&F 0.63 mm thick Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) |
| 35 | Ditto as per above item but except sheet |
| 36 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 37 | S&F Pre- painted galvatume aluminum zinc coating GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 38 | Ditto as per above item but except sheet |
| 39 | Taking down door chowkhat with shutter area n-exc 1.5 Sqm each(without taking off shutters from the frame) complete all as specified & directed. |
| 40 | Taking down chowkhats or frames with shutters exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutters from the frame) complete all as specified & directed. |
| 41 | Taking down shutters of any description n. exc 1 sqm each complete all as specified & directed. |
| 42 | Taking down shutters of any description area exc 1 sqm and n exc 2 sqm each complete all as specified & directed. |
| 43 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, size 140 mm, complete,all as specified and directed. |
| 44 | S&F door closers of aluminium die cast body hydraulically regulated designation No 3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kgs and fixed, complete,all as specified and directed. |
| 45 | S&F power coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified |
| 46 | S&F power coated aluminium window & ventilator shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified |
| 47 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 48 | S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. complete all as specified |
| 49 | M&L for galvanised M S Wire cloth of 0.56 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple complete all as specified & directed. |
| 50 | M&L for 5.5mm thick sheet glass in squares exceeding .50 Sqm in each pane with oil putty in complete all as specified & directed. |
| 51 | Hacking out old broken glass (any thickness, size quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads complete all as specified & directed. |
| 52 | S&F 3mm thick glass sheet any size oridinary qlty in steel or wooden frames complete with fixing materials such as putty glazing pins wooden beads etc. |
| 53 | Cutting holes in brick walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required |
| 54 | S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 55 | S and F Steel windows for industrial buildings, fixed type, with glazing bars complete all as specified |
| 56 | S & F in repairs 20 mm dia Aluminium alloy anodised curtain rails with brackets and bullab fixed, complete all as specified and directed. |
| 57 | Schedule of Credit Please Enable Macros to View BoQ information |