| 1 | Farm Machinery Hub |
| 2 | PART-A ( CIVIL ) |
| 3 | Foundation excavation in Earth work in hard soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department etc. complete.etc. complete as per direction of Engg-in-Charge . |
| 4 | Filling foundation and plinth with sand and well watered and rammed including cost, conveyance and royalty etc complete as per direction of Engg.-in-Charge. |
| 5 | Cement Concrete (1:4:8) by using 40 mm size hard granite crusher broken stone metal of approved quality and from approved quarry including lowering laying concrete, watering and curing etc. complete for required levels laid in layers including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work etc. complete as per the direction of the EIC. |
| 6 | Plain cement concrete (1:2:4) using 12 mm size hard granite crusher broken chips of approved quality and from approved quarry including lowering laying concrete, watering and curing etc. complete for required levels laid in layers including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work etc. complete as per the direction of the EIC. |
| 7 | Fly Ash Brick masonry in c.m. 1:6 in F & P including cost,conveyance and royalty of materials curing etc. complete. as per the direction of the Engineer-in-charge. |
| 8 | Ist class Fly Ash brick masonry work in superstructure thoroughly soaked in water, with cement mortar (1:6) including scaffoldings ,racking out joints, curing etc complete as per specification/drawing and as per the direction of the Engineer-in-charge. |
| 9 | Ground Floor |
| 10 | Providing and Laying reinforcement Cement concrete (M-20) with 20 mm and down graded chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement & Centering, shuttering) as per direction of Engineer-in-charge. |
| 11 | Column Base |
| 12 | Ground Floor |
| 13 | Plinth Beam |
| 14 | Ground |
| 15 | Beam & Column |
| 16 | Ground Floor |
| 17 | Sun shade and Chajja |
| 18 | Ground Floor |
| 19 | Lintel |
| 20 | Ground Floor |
| 21 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete in proper position including cost of binding wire 18 to 20 gauge as per direction of Engg.-in-Charge. |
| 22 | Ground Floor |
| 23 | 12mm cement plaster in cement mortar (1:6)including necessary scaffolding curing etc. as per direction of Engg.-in-Charge. |
| 24 | Ground Floor |
| 25 | 16mm thick cement plaster in cement mortar (1:6) including necessary scaffolding curing etc. as per direction of Engg.-in-Charge. |
| 26 | Ground Floor |
| 27 | Fixing colour Vitrified tiles in floors (Printed Series) of size 600mm x600 mm of approved make conforming IS:13755 laid on 20 mm thick cement mortar (1:4)and filling joints with white cement of approved quality including cost of all materials, labour T&P etc rrequired for the work all completeas per direction of Engineer-in-charge. |
| 28 | Ground Floor |
| 29 | Fixing Vitrified tiles in dados (Printed Series) skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing complete as per direction of Engineer-in-charge. |
| 30 | Ground Floor |
| 31 | Cement washing one coats with cost of all labour & materials etc. complete as per direction of Engg-in-Charge . |
| 32 | Ground Floor |
| 33 | Wall painting two coats on new work with Distemper of approved shade etc. complete as per direction of Engg-in-Charge . |
| 34 | Ground Floor |
| 35 | Wall painting two coats on new work with Weather coat paint of approved shade as per direction of Engg.-in-Charge. |
| 36 | Ground Floor |
| 37 | Supplying and fixing of steel M.S. grill with all fitting and fixtures including cost of cutting holes in the brick masonry and R.C.C. columns and making good to damage etc, as per direction of Engineer -in -charge. |
| 38 | Ground |
| 39 | Painting two coats with approved paint on new iron work complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 40 | Ground Floor |
| 41 | Supply fitting and fixing of 0.450mm thick of size 1072mm x 3050mm Corogatted Sheet in in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. including cost of fitting as per direction of Engineer-incharge. |
| 42 | Ground Floor |
| 43 | Supply Fitting and fixing of Strusses made up of M.S hallow section pipe for rafters and perlins for fixing GCI sheet.including priming & painted with enamel paint etc. complete as per direction of Engineer-incharge. etc. complete as per direction of Engineer in charge. |
| 44 | Ground Floor |
| 45 | Iron work wrought and put up in trusses and record racks (labour only) |
| 46 | Hoisting stanchions, trusses and purlins and placing in position (labour only) |
| 47 | Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. [Group-C] |
| 48 | Light point |
| 49 | Farm machinery Hub |
| 50 | Sub Total |
| 51 | Fan point |
| 52 | Office |
| 53 | Sub Total |
| 54 | Grand Total |
| 55 | Providing, Supplying and fixing of metal box of 150 mm x 75 mm x 60 mm (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc as required. (For light plugs to be used in non residential buildings) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. |
| 56 | Farm machinery Hub |
| 57 | Total |
| 58 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick alongwith 1 x1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex/ L&T/Anchor /Havels /V Guard) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. |
| 59 | Providing & Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. |
| 60 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. |
| 61 | Providing & Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. |
| 62 | Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. |
| 63 | Supply and fixing of 5 amp to 32 amp rating 240 V \\"B\\" series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. |
| 64 | Supply, Installation, Testing, and Commissioning of 32 Amp DP Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. Make- SEIMENS /HPL /ANCHOR /L&T /HAVELS /C & S/ RK |
| 65 | Supply, Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. |
| 66 | Supply, Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, Labour welfare cess@1% etc. complete as per the direction for the EIC. Please Enable Macros to View BoQ information |