| 1 | Dismantling loose/unsound weaken cement concrete of any description from existing roof chajjas etc, (upto maximum height of 10 metres from natural ground level) with power driven pneumatic chisel and including removal of debris away from site and washing down with water to remove dust, foreign items complete all as specified and directed. |
| 2 | M&L for 25 mm thick average PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in padding concrete on roof all as directed by Engineer- in-Charge. |
| 3 | M&L PCC(1:2:4) type B-0 (using 20mm graded aggregate) as in roof kerbs or mud stop rounded complete all as specified and directed. |
| 4 | M&L for rendering 5mm thick on fair faces on roof surfaces of concrete in Cement Mortar 1:4 finished even and smooth without using extra cement and WPC complete all as specified and directed. Note :- WPC will measuered and paid separatly under relevant item of schedule. |
| 5 | M & L for providing water proofing treatment with a layer of APP based polymeric membrane, 3 mm thick (minimum), weighing not less than 3.60 kg/Sqm reinforced with polymer non woven fabric (weighing not less than 160 gm/ Sqm) shall be applied over one coat of cold bituminious primer @ 0.40 ltr/ Sqm ( membrane shall be laid using butane torch and sealing all joints etc, complete all as specified and directed .( Note: The overlaps shall be of minimum 75 mm on longitudinal direction and 100 mm on transverse direction) complete all as specified and directed. |
| 6 | M&L for one coat of aluminium paint over APP membrane at roof surfaces complete all as specified and directed. |
| 7 | Dismaltaling of plain or corrugated steel sheeting , any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and directed. |
| 8 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed. |
| 9 | All as per ser item No 8.00 here-in-before but except sheeting complete all as specified and directed. (any thickness). Note:- Sericeable galvalume sheets obtained from dismantling shall be reused after proepr cleaning and molulding. |
| 10 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified any height Mtr height including all necessary scaffolding and safety measures complete all as specified and directed. |
| 11 | All as per ser item No 10.00 here-in-above but except sheeting (any thickness). Note:- Sericeable galvalume sheets obtained from dismantling shall be reused after proepr cleaning and molulding. |
| 12 | M&L for under/ over deck leaking arrests to PUF/steel sheet roofs by using 5mm thick bituminous sheet (exc 29 sqcm and n exc 40 sqcm of each piece) including filling silicon sealand adhesive materials in holes, MS screws, washers etc where required at leakages of roof sheets all as specified and as directed. |
| 13 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete as directed. |
| 14 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails andfastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde-E-250) quality-B complete all as spd and directed. |
| 15 | S & F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as spd and directed. |
| 16 | Dismantling wall and ceiling board of any description complete all as specified and directed. |
| 17 | S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long complete all as specified. |
| 18 | S&F anodised aluminium snap grid of size 605 x 605 mm frame work for false ceiling complete all as sprcified and as directed. |
| 19 | S&F in repair for 6mm thick non asbestos fibre cement designer building boards fixed or laid on aluminium frame/grid with screws, complete all as specified and directed. |
| 20 | All as per item No 19.00 here-in-before but fixing only. Note: Serviceable ceiling boards shall be re-used obtained from dismantling. |
| 21 | M&L old size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius build in CM 1:6 including demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc completet all as specified as directed. |
| 22 | Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc complete all as directed. |
| 23 | M&L Rendering 15 mm thick cement plaster in CM 1:6 on fair faces of brick/concrete work surfaces finished fair and even complete all as specified and directed. |
| 24 | M&L for Rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete surfaces finished fair and even, mixed wth water proofing compound admixture (if directed) as per manufacturer's instruction, complete all as specified and directed.Note :- WPC will measuered and paid separatly under relevant item of schedule. |
| 25 | M&L for rendering 5mm thick on fair faces of ceiling / chajja concrete surfaces in cement mortar 1:3 finished fair and even complete all as specified and directed. |
| 26 | Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. over and including a coat of primer over plastered surfaces of walls complete all as specified. |
| 27 | M&L for prepration of new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 28 | M&L for prepartion of newly plastered ceiling surfaces and applying three coat of white wash complete all as specified and directed. |
| 29 | M & L for (a) providing and laying water proofing treatment of sunken portion of WCs, bathroom etc by applying cement slurry with acrylic based modified cementitaous composite compound coating of make as approved in technical instruction 5/2003 (b) First layer of slurry of cement @ 0.5 Kg/Sqm mixed with acrylic based polymer modified cementatious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cure for 4 hours. (c) second slurry of cement @ 0.500 Kg/Sqm mixed with acrylic based polymer modified cementatious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (d) 200 micron thick polythene film pasted with the help of bituminous adhesive shall be provided over treatment. |
| 30 | Taking down steel tubing having bore of pipe 15 mm and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 31 | Taking down steel tubing having bore of pipe 20 mm and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 32 | Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good, cutting n. exc. 10cm girth. |
| 33 | S&F 16 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 34 | Fixing only 15mm dia bore old steel tubing after necessary cleaning, with and including all new tube fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc and necessary connections in old position (Walls, ceiling, floors, etc.) complete all as specified and as directed |
| 35 | S&F 20 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 36 | Fixing only 20mm dia bore old steel tubing after necessary cleaning, with and including all new tube fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc and necessary connections in old position (Walls, ceiling, floors, etc.) complete all as specified and as directed |
| 37 | Disconnecting existing tanks(Exc 250 & n exc 500), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as spd and directed by Engr-in-Charge. |
| 38 | S & F rotational moulded polyethylene ISI marked (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position with and including Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 20/25mm bore dia iron pipe, provision of 20 mm /25 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. |
| 39 | Supply and fix in repair bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed. |
| 40 | S&F in repair 15mm bore fancy type stop valve, chromium plated concealed type cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 41 | Supply and fixing in repair stack clamps made out of 50mm x 5MM Flat iron and 16 mm round iron stay incl bolts and nuts and securing ends stays to wall or roof includding taking down the existing clamps for rain water pipe or CI pipe 100mm bore at any height complete all as specified and directed. |
| 42 | S&F PVC SWR pipes 150 mm bore single socketed in any length with rubber ring joint fixed to wall with PVC clamps for rain water pipes including taking down old PVC/CI pipe all as specified and directed . Make : Supreme/ Finolex. |
| 43 | S&F PVC SWR bends of 150 mm bore complete all as specified and directed. |
| 44 | S&F PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to wall with steel clamps all as specified and directed . Make : Supreme/ Finolex. |
| 45 | S&F PVC SWR bends of 110 mm bore complete all as specified and directed. |
| 46 | S&F PVC (SWR) junction single (single T) equal or unequal provided with access door of 110 mm dia complete all as specified and directed. |
| 47 | S&F as in repair grating square 150mm size of PTMT(minimum 100 gms) complete all as specified and directed. |
| 48 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing to low lying area and rubbish off the premises complete all as specified and directed. |
| 49 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tiles exc. 0.06 sqm but n. exc 0.11 sqm of approved colour as in floors etc set and joined in neat cement slurry over 15mm thick sreed bed of cement mortar (1:6) complete all as specified and directed. |
| 50 | M&L for Glazed ceramic tiles Coloured 350 x 250mm/450 x 350mm 7 to 8 mm thick in wall/dado etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match rendering over 10 mm thick in CM 1:4 on stone masonry surfaces or surfaces other than fair face of brick work/ concrete surfaces complete all as specified and directed. |
| 51 | S & F in repairs vitreous china squatting pan, 'Orissa\\" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing , connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 52 | S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 53 | S&F in repairs 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete (with brackets). |
| 54 | Supply and fix in repair for Gun metal gate valve,15 mm bore, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and as directed. |
| 55 | Supply and fix in repair for Gun metal gate valve, 20 mm bore, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and as directed. |
| 56 | Demolition of cement Concrete of any description and in any position not otherwise specifically provided for, complete all as directed. |
| 57 | M&L for 100mm thick Cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in floors, fisnished even and smooth without using extra cement complete all as specified. |
| 58 | Supply only Liquid water proofing compound complete all as specified and directed. Please Enable Macros to View BoQ information |