| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF), Air Force Station, Phalodi Name of Work :PROVN /ADDN AND ALTERATION OF CERTAIN MW AT DIFFERENT LOCATIONS OF AF STATION PHALODI. Contract No: GE (AF) PHALODI/ OF 2026-27 Serial Page No. Bidder Name : SCHEDULE 'A'(BOQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT TEXT # NUMBER TEXT NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER NUMBER # TEXT Srl.No. Item Description Item Code / Make Approx No of Units reqd Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 3 | M&L for 25mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate ) as in floor finishes and leveling course complete all as specified and directed. |
| 4 | M&L for vitrified ceramic tiles light shade 10mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed in CM (1:6) complete all as specified and directed. |
| 5 | M&L for joint free (edge cut) coloured glazed ceramic tiles 450x300x7mm/ 350x250x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to the match tiles on vertical surface over and including 10mm thick plaster in CM (1:3) complete all as specified and as directed. |
| 6 | S&F 605X605mm anodised aluminium snap grid frame work for false ceiling using main tee of size 25x35x1.5mm & cross tee of size 25x35x1.5mm, aluminium anodised angle section 25x25x1.5mm including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 7 | S&F Providing and fixing Gypsum false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed. |
| 8 | M&L for providing 100mm thick, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of floors and pavings etc complete all as specified and as directed. |
| 9 | Dismantling & reuse of old retrived Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment over sand filling under floors including spearding and levelling in layers n exc. 25 mm thick, watering and consolidation. all as specified and directed.Note: sand filling will be measured and paid seprately under respective items. |
| 10 | M&L for sand filling under floors including spearding and levelling in layers n exc. 25 cm thick complete all as specified and directed. |
| 11 | M&L Precast cement concrete type C1 (1:3:6) using 20mm graded stone aggregate block masonry with solid blocks exc. 10 cm in width and setting in cement mortar (1:6) complete all as specified and directed. |
| 12 | M&L for Rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished surface fair and even complete all as specified and directed. |
| 13 | S&F for printed /etching 12mm thick toughened glass door with all necessary hydraulic floor spring incl top patch, bottom patch and 30cm long stainless steel handle set and central stainless steel lock complete all as specified and as directed. |
| 14 | S&F 12mm Toughned glass with etching and digitally printing names and logos of size 12 to 15 cm in english & Hindi letters as per user requirement, as in partitions for doors/windows and similar work including cutting to shape, drilling holes required including necessary joining cleats, glazing clips, rubber packing,etc gaps filling with silicon complete all as directed. |
| 15 | S&F anodised powder coating of any colour aluminium partition fixed type made from 101.60x44.45x1.5mm thick section fully glazed incl all necessary jointing cleat, glazing plate and clips, rubber, gasket packing, snap beading with 3.00mm thick ACP board laminated sheet complete all as specified and as directed |
| 16 | Excavation over areas n.exc 1.50 m deep and getting out soft/loose soil complete all as specified and directed. |
| 17 | Returning and filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and as directed. |
| 18 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified & directed. |
| 19 | M&L for PCC (1:4:8) type D2 using 40 mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 20 | Use and waste Formwork to Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses,etc.; vertical or to batter complete all as specified and as directed. |
| 21 | M&L for RCC M-30 design mix as in Walls, retaining walls,basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed. |
| 22 | M&L for RCC M-30 design mix as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 23 | M&L Mild steel bars TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 24 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. all as directed. |
| 25 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and directed. |
| 26 | S&F mild steel roof trusses (framed), trussed, purlins, crane, gantries, rails and fastening and heavy bracket framing (beam, tee, angle, channel or flat sections) incl distance pieces, cleats and micro jacketing work to RCC columns, beams etc. conforming to Fe 410-0 (Gde E-250) quality 'A' complete all as specified and directed. |
| 27 | S&F S&F mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde- E- 250) quality-A complete all as specified and directed. |
| 28 | S&F Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30 cm long of diameter of neck 20 mm complete all as specified and directed. |
| 29 | M&L for preperation of new steel surfaces over 10 cm in width or girth and applying two coat of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed. |
| 30 | Excavating post holes (or similar holes) each n exc 0.5 cu m, getting out hard/ dense soil including cutting of PCC floor & removing surplus soil and debris to a distance n exc 50m and making good surface complete all as specified and directed. |
| 31 | M&L for PCC 1:2:4, type B2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 32 | M&L for anodised aluminium powder coated of any colour frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 33 | S&F for anodised aluminium powder coating window and ventilator shutters, side hung/sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 34 | S&F for anodised aluminium powder coating of any colour (Thickness or powder coating not less than 50 micron) door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 35 | S&F door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed with Aluminium (extruded section body) complete all as specified and directed. |
| 36 | S&F Sheet glass 5.50 mm thick ordinary quality and glazing with beading in squares exc 0.5 Sq.m in each pane complete all as specified and directed |
| 37 | M&L for Preparation of new plastered surfaces and applying two coat of oil bound distemper over a coat of primer with 3mm thick wall putty on internal surfaces of walls complete all as specified and directed. |
| 38 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 39 | Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 40 | Taking down chowkats or frames with shutters (without taking off shutters from frames) exc. 1.5 sqm but n. exc 4 sqm each complete all as specified and directed. |
| 41 | Taking down chowkats or frames with shutters (without taking off shutters from frames) not exc. 1.5 sqm each complete all as specified and directed. |
| 42 | Excavation in trench n.exc 1.5 m deep and nexc 1.5 m width in soft/loose soil complete all as specified and directed. |
| 43 | Returning filling in with approved excated soil including spreading, levelling in layers not exc 25cm thick complete all as specified and directed. |
| 44 | Removing excavated material (soil) to a distance exc. 1.50 km but n exc. 5 km and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 45 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 46 | Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Rough finished surfaces of concrete flat complete all as specified and directed. |
| 47 | Formwork to sides of pillars, posts, struts, piers,columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal compete all as specified and directed. |
| 48 | Use and waste of formwork to sides and soffits of floor or roof beams , lintels, cintilevers, shelves for flat surfaces complete all as specified and directed. |
| 49 | M&L for TMT MS bars of 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to lengh bent to shape reqd incl cranking bending spirally for hooking for column and binding with MS annealed wire not less than 0.9mm dia complete all as specified and directed |
| 50 | M&L RCC (nominal mix) in type B-1 (1:2:4) using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 51 | M&L RCC (nominal mix) in type B-1 (1:2:4) using 20 mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 52 | M&L for RCC (nominal mix) in type B-1 (1:2:4) (20mm graded stone aggregate) as in Beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and directed. |
| 53 | S&F for printed /etching 12mm thick toughened glass door with all necessary hydraulic floor spring incl top patch, bottom patch and 30cm long stainless steel handle set and central stainless steel lock complete all as specified and as directed. |
| 54 | S&F for printed /etching 12mm Toughned glass as in partitions for doors/windows and similar work including cutting to shape, drilling holes required including necessary joining cleats, glazing clips, rubber packing,etc gaps filling with silicon complete all as specified and directed. |
| 55 | Excavation in over areas not exc 1.5 m depth , and for foundation, shafts,wells,manholes, cesspits etc in any type of soil & getting out, complete all as specified and directed. |
| 56 | M&L for Reinforced cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) as in walls, ballast walls and the like, any thickness; above top of footings; including attached pilaster and buttressesment wall etc , complete all as specified and directed. |
| 57 | M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for manholes/soakage well and similar works supported on walls set in cement mortar 1:6 complete all as specified and directed.Note:- Reinforcement steel will be measured & paid separately. |
| 58 | Removing excavated hard/ dense soil material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 59 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter of rough finishes , complete all as specified and directed |
| 60 | M&L for 10 mm thick rendering in cement sand mortar 1:3 with water proofing compound @ 3% weight of cement on fair faces of brick work/ block massonary or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.Note: Water proofing compound shall be paid for separetly . |
| 61 | Supply only integral Water proofing compound complete all as specified and directed. |
| 62 | M&L for 150 mm bore reinforced concrete pipe, class NP2 laid & jointed complete with collars Coomplete all as specified & directed. |
| 63 | M&L for Plain cement concrete 1:4:8 type D2 (Using 40mm graded crushed stone aggregates) as in bed to pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150mm bore complete all as specified and directed. |
| 64 | S &F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 65 | S&F of 1 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 66 | M&L for 10mm thick cement plaster in CM 1:3 mixed with liquid water proofing admixture as per manufacture's instruction on roof surfaces and finishing even and fair to receive APP membrane complete all as specified. (Note : LWPA shall be measured and paid separately ) |
| 67 | M&L for glazed ceramic coloured joint free tiles in vertical surfaces 450X 350X 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement complete all as specified and directed |
| 68 | M& L for Squared rubble walling, Jodhpur type, laid dry, brought to course and well bonded complete all as specified and directed. |
| 69 | S & F Dholpur stone type elevation tiles in vertical surface suniform colour of each stone tiles size exceeding 0.09 sqm area and not exceeding 0.5 sqm set and jointed in neat cement slurry and pointed in white or coloured cement, incl backing coat of 10 mm thick in CM 1:3 complete all as specified and as directed. |
| 70 | Supply and fixing of Flame proof 48\\" ceiling fans with flame proof regulator, designed for hazardous areas (Zones 1, 2, 21, 22), typically utilizing die-cast aluminum (LM6), certified (CIMFR/PESO, BIS) to prevent ignition of exlosive atmosphere. Explosion proof (Ex-d) as per IS/IEC 60079-1:2014, die cast aluminium bodies, T6 temperature classification, 1200mm sweep, IP-65 weather protection, blades shall be of M.S. powder coatedor aluminium, voltage and power: 230V AC single phase, 50 Hz, 400 RPM. Cable entries(M20/2\\" NPT / Equivalent), Insulation Class F, Epoxy powde coated complete all as specified and directed.Note: Rates for Supply and fixing of weather/ flameproof SS flexible conduit, and SS glands for connection shall be included in the quoted rate. |
| 71 | Supply and fixing of Flame proof 12\\" exhaust fan designed for hazardous areas (Zones 1, 2, 21, 22), typically utilizing die-cast aluminum (LM6), certified (CIMFR/PESO/CCOE) to prevent ignition of exlosive atmosphere. Explosion proof (Ex-d) as per IS:2148-2004/ IEC 60079-1, Motor power: 230V AC50 Hz, 1440 RPM, cast iron body, aluminium alloy blades and heavy duty casing, IP65/66 (dust and water protected), tempertaure class T6, neoprene gasket, detached glavanised iron (GI) mesh guard, epoxy grey painiting, complete all as specified and directed.Note: Rates for Supply and fixing of weather/ flameproof SS flexible conduit, and SS glands for connection shall be included in the quoted rate. |
| 72 | Material and labour for One 3 pin 5 amps socket out let point on independent board Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable FRLSH of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC casing capping not less then 20 mm width including all necessary wall cutting and making good disturbed surfacecomplete all as specified and directed. |
| 73 | Material and labour for Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 4.0 Sqmm, with PVC insulated unsheathed stranded copper conductor cable FRLSH of size 4.0 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC conduit not less then 20 mm width including all necessary wall cutting and making good disturbed surface all as directed and specified. |
| 74 | S&F of Modular AC Box With 20A SP MCB, Metal Enclosure& Unbreakable Heavy Duty With ISI Plug Top complete all as specified and directed. |
| 75 | Supply and fixing of 3 Module plastic surface box to accommodate modular plate and switch & socket complete all as sepcified and directed. |
| 76 | S&F modular White cover plate with frame 3 module complete all as specified and directed. |
| 77 | S&F modular Switch one way 6 Amps, 1 module 240 V complete all as specified and directed. |
| 78 | S&F for modular socket 3 pin 5 Amps 240 V, combined 2 module flush type complete all as specified and as directed. complete all as specified and directed. |
| 79 | Supply and fix wall mounted fan 400 mm sweep made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, 100% Copper winding motor, induction motor complete all as specified and directed. |
| 80 | M&L for One light point controlled by one, one way switch, Concealed Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable FRLS of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC conduit not less then 20 mm dia with metal sunken boxes including all necessary wall cutting and making good disturbed surface all as directed and specified . Note Cutting chases, plastering and making good to match with the adjoining surface shall be included in the unit rate. |
| 81 | M&L for One ceiling /exhaust fan point controlled by one switch, Note : - Rate shall be included for connection of ceiling rose to fan by using 3 core flexible copper wire in white colour, Concealed Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable FRLS of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC conduit not less then 20 mm dia with metal sunken boxes including all necessary wall cutting and making good disturbed surface all as directed and specified . Note Cutting chases, plastering and making good to match with the adjoining surface shall be included in the unit rate. |
| 82 | M&L for One 3 pin 5 amp socket out point on the same board with other switches, Concealed Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable FRLS of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC conduit not less then 20 mm dia with metal sunken boxes including all necessary wall cutting and making good disturbed surface all as directed and specified . Note Cutting chases, plastering and making good to match with the adjoining surface shall be included in the unit rate. |
| 83 | M&L for One3 pin 5 amps socket out let point on independent board, Concealed Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable FRLS of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC conduit not less then 20 mm dia with metal sunken boxes including all necessary wall cutting and making good disturbed surface all as directed and specified . Note Cutting chases, plastering and making good to match with the adjoining surface shall be included in the unit rate. |
| 84 | All as per same in item No 79 above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire complete all as specified and directed. |
| 85 | Material and labour of Concealed sub main wiring power/circuit using FRLSH PVC insulated unsheathed, stranded copper conductor cable 2 runs of size 4.00 Sqmm, earth continuity conductor of size 4.00 Sqmm to be drawn through and including PVC conduit 20 mm dia concealed in walls/roof/floors all as directed.Notes:- (i)Two wires of 4.00 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit. |
| 86 | S&F of modular White cover plate with frame 6 module complete all as specified and directed. |
| 87 | S&F of modular White cover plate with frame 3 module complete all as specified and directed. |
| 88 | S&F of Modular AC Box With 20A SP MCB, Metal Enclosure & breakable Heavy Duty With ISI Plug Top complete all as specified and directed |
| 89 | S&F of modular Switch one way 16 Amps, 1 module 240 V complete all as specified and as directed. |
| 90 | S&F of Modular socket 6 pin 15 Amps 240 V, 2 module flush type complete all as specified and as directed. |
| 91 | S & F Modular Fan step regulator, 120W - 2 module complete all as specified and as directed. |
| 92 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 93 | S&F of triple pole & neutral DB, 4 way (double door), conforming to IEC 61439- 3, suitable for flush mounting with 100 A insulated & shrouded copper busbar for each phase, 2 fully insulated & shrouded neutral bar, 2 earth bar, wire set and cable ties for cable management, IP 43 & IK 09 protection with reversible metal door with provision for 4 Pole MCB as incomer and TP/SP MCBs as outgoing, all complete as specified and directed. NOTES: (i) MCBs & MCCBs shall be measured and paid in separate items. |
| 94 | Supply and fixing MCB TPN 440 Volts, 'B' series, breaking capacity 10 KA of rating 63-100 Amps complete all as specified and as directed. |
| 95 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Double poles (DP) and current carrying capacity 25 Amps in the MCB DB complete with connection testing and commissioning. complete all as specified and as directed. |
| 96 | Supply & Laying XLPE insulated armoured PVC Sheathed LT (1100 Volts grade) cable with aluminium conductor of size 35 Sqmm 3.5 core in trench, on wall/roof or passing through GI pipes including all fixing arrangements complete all as specified and as directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 97 | Excavation in trenches n.exc 1.50m wide and n exc 1.50m in depth for foundation etc n.exc 10 sqm on plan and getting out in soft & loose soil complete all as specified and as directed. |
| 98 | Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed.Note : Measurement will be done after punning |
| 99 | M & L for brick sub class ‘B’ old size to be laid over dry sand cushioning in trenches as protection to cable complete all as specified and directed. |
| 100 | Supply and lay /fixed on walls GI pipe 40 mm dia light grade for protection of LT Cable complete all as specified and as directed. |
| 101 | M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level) connected to galvanized earth lead wire of 4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 40 mm dia light grade GI tubing for protection of earth lead, MS sheet m etal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt necessary excavation, earth work, in soil/loose soil and disposal of soil to a distance not exc 15 Mtr and necessary connection and testing complete all as specified and as directed. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |