| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed.Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 2 | M&L for Rendering 15 mm thick in cement mortar 1:4 , mixed with water proofing compound, on brick or concrete surfaces, trowelled to even and fair finish without using extra cement (WPC to be measured separately) complete all as specified.Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 3 | Supply only liquid Water proofing compound complete. |
| 4 | M&L for Rendering 15 mm thick in cement mortar 1:6, on brick or concrete surfaces, trowelled to even and fair finish without using extra cement complete all as specified.Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 5 | Rendering 5 mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and smooth without using extra cement all as specified. |
| 6 | M&L for preparation of new plastered surfaces of walls and applying two coat of interior emulsion paint by using roller to wall surfaces over and including a coat of acrylic wall care putty of 0.5mm to 1mm thick ( in 1/2 coats as required) complete all as specified. Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. 2. The second coat will be done after 1st coat checked by Engr-in-ChargeMake : Asian Paints/Berger/Nerolac (Ist Quality) |
| 7 | M&L for preparation of new plastered surfaces of walls and applying two coat of oil bound distemper including 0.5 to 1 mm thick white wall care putty (in 1/2 coats as required) complete all as specified and directed.Note: The second coat will be done after 1st coat checked by Engr-in-ChargeNote:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. 2. The second coat will be done after 1st coat checked by Engr-in-ChargeMake : Asian Paints/Berger/Nerolac (Ist Quality) |
| 8 | M&L for preparation of new plastered surfaces on walls and applying three coat of white wash complete all as specified and directed. |
| 9 | M&L for preparation of new plastered surfaces to external walls/RCC surfaces/soffits of chajjas/roof projections /cantilevers /balcony etc surfaces and applying two coats of exterior emulsion paint by using roller over and including wall care putty of 0.5mm to 1mm thick ( in 1/2 coats as required) complete all as specified.Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. 2. The second coat will be done after 1st coat checked by Engr-in-ChargeMake : Asian Paints/Berger/Nerolac (Ist Quality) |
| 10 | M&L for prepartion of new plastered surfaces of walls and applying two coat of cement based paint on external walls complete all as specified and directed.Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. 2. The second coat will be done after 1st coat checked by Engr-in-ChargeMake : Asian Paints/Berger/Nerolac (Ist Quality) |
| 11 | M&L for preparation of new plastered surfaces of ceiling and applying three coat of white wash complete all as specified |
| 12 | M&L for preparation of old plastered /treated surface of walls (plastered/unplastered ) including cornices, Pilasters etc by brooming down or steel wire brushing, scraping down smoke , soot moulds , moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash, leaving premises clean and tidy all as specified and directed by the Engineer-in Charge.Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. 2. The second coat will be done after 1st coat checked by Engr-in-Charge |
| 13 | All as per item No 12 above but one coat of white wash on ceilings. |
| 14 | All as per item No 12 above but one coat of oil bound distemper on walls. |
| 15 | All as per item No 12 above but one coat of cement based paint on walls. |
| 16 | All as per item No 12 above but one coat of interior emulsion paint by using roller to wall surfaces. |
| 17 | All as per item No 12 above but one coat of exterior acrylic emulsion paint by using roller to wall surfaces. |
| 18 | Preparation of old plastered/treated surfaces of steel/asbestos sheet (wall/roof) and applying one coat of synthetic enamel paint as in camouflaging pattern having percentage of colour as 40% olive green, 40% dark brown and 20% sand stone at height n.exc 15mtr as per sample/pattern approved by GE complete all as specified and directed by Engr-in-Charge. Note :- 1. The %age of the three colours may change without any financial effect by the approval of GE. 2. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. 3. The second coat will be done after 1st coat checked by Engr-in-ChargeMake : Asian Paints/Berger/Nerolac (Ist Quality) |
| 19 | Preparation of old treated/plastered surfaces and applying one coat of exterior emulsion paint in camouflaging pattern having percentage of colour as 40% olive green, 40% dark brown and 20% sand stone as per sample/pattern approved by GE complete all as specified and directed by Engr-in-Charge. Note : 1. The %age of the three colours may change without any financial effect by the approval of GE. 2. The second coat will be done after 1st coat checked by Engr-in-ChargeMake : Asian Paints/Berger/Nerolac (Ist Quality) |
| 20 | Preparation of old steel and iron surfaces of any description exc 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. 2. The second coat will be done after 1st coat checked by Engr-in-ChargeMake : Asian Paints/Berger/Nerolac (Ist Quality) |
| 21 | M&L for preparation of old painted wooden surface of any description in any position and location not otherwise described over 10 cms width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engr-in-Charge . |
| 22 | Dismantling Asbestos Cement (corrugated, semi-corrugated,etc.) sheet in roof coverings complete.Note : The rates includes rates of scaffolding to work at a height of 10-15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 23 | S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws,complete, all as sepcified and directed.Note : The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 24 | S&F pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete, all as sepcified and directed.Note : The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 25 | Dismantling wrought iron or mild steel work of any description not otherwise provided for purlins, runners etcNote : The rates includes rates of scaffolding to work at a height of 10-15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 26 | Demolition of brick work built in cement mortar complete all as specified and directed. |
| 27 | M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 all as specified. |
| 28 | S&F steel work in square pipe/tubular/angle as in post, rafter, purlins, including special shaped washer etc, complete using ERW or induction butt welded tubes including distances pieces, base plates, nut bolts etc including complete all as specified and directed. |
| 29 | M&L for preparation of new surfaces of steel of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete. |
| 30 | S&F in repair amluminium door closer (extruded section) hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 Kg complete. |
| 31 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified. |
| 32 | Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified. |
| 33 | S&F factory made Flush shutters 30mm solid core construction, with block board core and plywood face panels, commercial type on both sides |
| 34 | S&F 2nd class hard wood factory made plain framed panelled door shutters 35mm thick (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both sides. The size of rail and stiles as per IS:1003 (Part I), Klin seasoned and chemically pressure treated complete all as specified and directed. |
| 35 | S & F factory made pressed steel frames size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified. |
| 36 | S & F factory made pressed steel frames size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified. |
| 37 | M & L for providing PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in filling pressed steel frame |
| 38 | S&F factory made solid PVC door, cup board shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded both side prelaminated PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & prelaminated PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail, lock rail & bottom rail panelling of prelaminated PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specification & diagram/product drawing shown on ser page No 156 of SSR Part II complete all as specified and directed. |
| 39 | S&F factory made solid PVC door, cup board frame size 50mmx47mm made out of 5mm Prelaminated PVC sheet reinforced with MS square tube all as per specification and as per drawing shown on ser page No 150 of SSR Part II (for item 884) complete all as specified and directed. |
| 40 | S&F Stainless steel butt hinges medium weight 100mm long complete all as specified and directed. |
| 41 | S & F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete |
| 42 | M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed. |
| 43 | S&F Aluminium anodised barrel tower bolt of extruded section 150 mm size complete all as specified and directed. |
| 44 | S&F aluminium alloy anodised sliding door bolt with hasp and stapple ( bolt type) and fixing clips of sheet cast or extruded section with fixing bolts and sliding bolt of extruded section 300mm length & dia not less than 12mm with & including 6 Nos of bolts complete all as specified and directed. |
| 45 | M&L for Powder coated (Minimum thickness of powder coating 50 micron) Anodised aluminium frames and shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F 12mm thick high density fibre board pre-laminated on both sides (water proof) below & above middle/lock rail in powder coated aluminium doors and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc aluminium beads 20 mm size with and complete all as specified and directed by Engr-In- Charge |
| 47 | S&F 4.80 mm thick glass for aluminium windows including EPDM gasket to render the glazing, air and water tight etc and power coated aluminium beeds 20 mm size complete. |
| 48 | S&F stainless steel wire gauge 0.36 mm nominal dia of wire and average width of aperture 1.40mm to be fixed in Powder coated aluminium windows/ ventilators etc complete. |
| 49 | S&F stainless steel (304 grade) powder coated butt hinges 100mm complete all as specified and directed. |
| 50 | S&F powder coated aluiminium tower bolt 150mm long complete. |
| 51 | S&F powder coated aluminium handles(American type) 150mm complete. |
| 52 | S&F powder coated aluminium hook and eye of suitabel length adjustable to aluminium window shutters compelte. |
| 53 | S&F integrated lock for aluminium doors with 2 keys, complele all as specified and directed.. |
| 54 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beadsNote:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 55 | M&L for Sheet glas 4mm thick ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each paneNote:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 56 | S&F in repair 75 mm bore PVC (SWR ) PIPE in any length fixed to walls and floor with and including rubber ring joint and MS clamps .. |
| 57 | S&F in repairs 110 mm bore PVC (SWR ) PIPE in any length fixed to walls and floor with and including rubber ring joint and MS clamps made of 40x3mm FI of required size .Note:- 1. The rates includes rates of scaffolding to work up to a height of 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 58 | M&L PVC(SWR) bends 75 mm(any radius), diminishing pieces or tapers(larger bore measured) fixed in repairs |
| 59 | M&L PVC(SWR) bends 110 mm(any radius), diminishing pieces or tapers(larger bore measured) fixed in repairs |
| 60 | M&L for repair of rolling shutter of hangers without taking down of existing shutter including replacement of roller/slider/any parts(roller/slider/any parts will be measured and paid separately) of shutter as well as greasing/oilin of shutter to make it function smooth, area of hangers exc 20Sqm complete all as specified and directed. |
| 61 | S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming Fe-290(Gde E 165) |
| 62 | Dismantling wall and ceiling boarding of any description, thickness including cover fillets complete al as specified and directed. |
| 63 | M&L for prelaminated HDHMR board, exterior grade 18/19 mm thick phenol formaldehyde bonded, flat pressed and having choice lamination on one side and balancing white lamination on other side or both side white lamination fixed with screws, solvent cement/ adhesive to make kitchen/bed rooms cabinet sides top and bottom and shelves inside the cabinets complete as per manufacturer’s specifications complete all as specified and directed. |
| 64 | S&F hollow PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet used instead of plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing etc all as recommended by manufacturer all as specified. |
| 65 | Providing & Fixing semi perfoarted 12mm thick micro tegular edge false ceiling at all height with GRG (Glass fibre Reinforced Gypsum) false cell of size 595x595 mm of approved texture , design and patterns having moisture content less than 2% , humidity resistance of 99% ,NRC 0.50 to 0.75 as per IS 8225/1987 , Non combustible as per BS 476 Part 4, 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm incl both sides) comprising of main T runners of size 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 3000 mm , cross of T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm, suspended form ceiling using galvanized mild steel hanger rod (galvanized @ 80 grams per sqm )i.e minimum 50 mm long, 8 mm outer diameter M-6 dash fasteners , 6 mm fully threaded hanger rod up to 1000 minimum length as per length required at site for desired height and L-shape level adjust of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of 40 mm long SS screws with plastic raw plugs at 450 mm long SS screws with plastic raw plugs at 450 mm centre to centre , with semi perforated 12 mm thick micro tegular edged GRG false ceiling , complete all as specified and directed. |
| 66 | Taking up or down existing steel tubing and connections, 15mm bore complete all as specified. |
| 67 | S&F 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor ctc complete all as specified. |
| 68 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc 10 cm girth on brick walls complete all as specified and directed |
| 69 | Taking up or down existing steel tubing and connections, 20mm bore complete all as specified. |
| 70 | S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified. |
| 71 | Dismantling of water tanks exc 250 & n exc 500 ltr capacity & removing to store all as directed by the Engr-in-Charge. |
| 72 | Rotational moulded polythene water storage tank cylindrical vertical with closed top 500ltr capacity hoisted and fixed in position, connecting to inlet or outlet and washout including disconnecting and demolition of existing tanks of any description. |
| 73 | S & F in repairs Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 74 | S&F in repairs Vitreous china squatting pan of Orissa patten size 580 x 440 white with (C I P trap long size) joint run and lead front or back inlet with integral footrest including connection to trap and to flushing pipe,anti- syphonage pipe, etc, fixed in repair complete and making good to floor in CM 1:3 all as directed and specified.Cera or equivalent from Parryware/Hindware as approved by AO |
| 75 | S&F in repair vitreous china premium/1st quality wash down water closet pan floor mounting (pedestal pattern/EWC) S/P trap white/ivory including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe CP 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm S/P trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors G.F.and taking down existing of any description/size complete in all respect all as specified. |
| 76 | S&F in repairs low level flushing cistern of PVC 10 ltr capicity incl 45cm long PVC connection with brass nut at both ends, PVC flush pipe 32 mm bore and fixing as per manufacturers instruction incl taking down HL/LL flushing cistern and making good the disturbed surfaces in CM 1:3 complete all as specified and directed. |
| 77 | Supply & Fix Vitreous China Urinal, half stall type, white including flat back ,white (min) with grating and union for discharge pipe including waste pipe etc. complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed. |
| 78 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimumweight 60gms) |
| 79 | S&F in repair Vitreous china wash hand basin white flat back size 550 x 400 mm including PVC waste pipe 32 mm bore and CP Waste coupling with and incl a pair of suitable mild steel brackets, complete all as specified . |
| 80 | S&F in repair health faucet (ABS Body) with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 81 | S&F in repair PVC connection 600mm long of dia 15mm complete complete all as specified and directed. |
| 82 | S&F in repair stop cock /Angle cock 15mm cast copper alloy,screwed down, with chromium plated fancy type high pressure screwed both ends for iron pipe or for union complete all as specified and directed. |
| 83 | S&F in repair 15mm bore stop cock fancy type, chromium plated with long shank and cup (concealed type) screwed down, fancy type high pressure screwed both ends for iron pipe or for union complete all as specified and directed. |
| 84 | S&F in repair stainless steel grating 150x150 mm size square shaped with cockroach trap for floor trap fixed in position complete all as specified . |
| 85 | S&F in repair bib taps (long body) 15mm bore of cast copper alloy chromium plated fancy type, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed. |
| 86 | S&F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe 15 mm bore complete all as specified.Make : Jaguar, Marc/Cera as approved by AO |
| 87 | S & F central hole basin mixer with popup waste system and 450 mm long braided hoses, fancy type, cast copper alloy, with capstan heads, chrmium plated screwed down, high pressure with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe complete all as specified and directed by Engr-in-Charge. |
| 88 | S&F in repair stainless steel soap dish, complete all as specified and directed. |
| 89 | S&F in repair 125mm size brass chromium plated shower rose fixing with 15mm dia pipe complete all as specified and directed. |
| 90 | S&F in repair 6mm thick looking mirror fixed to wall with stainless steel plugs/connecter/spacers/screws etc. chrome finish without any beading, including ends/edges of the mirror to be tapered etched smooth finish etc.complete fixed in position all as specified and directed. |
| 91 | S&F in repair 650mmX400mm size bevelled edge mirror of selected quality glass 5mm to 5.5mm thick mounted on 6mm AC building board or commercial ply wood and plastic framing fixed to plugs with CP brass screws and cup wahsers complete all as specified and directed. |
| 92 | S&F in repair tubular towel rail 20mm dia D type and 60cm long ,brass chromium plated complete all as specified and directed. |
| 93 | Dismantling, floor, hearth or wall tiling including CM (bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed |
| 94 | M&L for Virified Ceramic tiles light shade premium quality coloured tiles 600 X 600 mm and 8-10 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, set and pointed in white or coloured cement to match, in floors etc. over & including 15 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 95 | All as per Item No 94 above but on vertical surfaces such as in skirting/dado etc and including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 96 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 15 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 97 | All as per Item No 96 above but on vertical surfaces such as in skirting/dado etc and including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 98 | M&L for ceramic glossy finish, joint free premium quality coloured tiles 600 X 300 mm and 8-9 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 99 | M&L for anti-skid ceramic joint free premium quality coloured tiles 400 X 400 mm and 6-7 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. over & including 15 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 100 | Demolition of cement concrete of any description and in any position not otherwise specially provided for |
| 101 | M&L PCC type C-1 Mix 1:3:6 (20mm graded stone aggregate), 50mm thick in plinth protection/path finishing the top surface even and smooth without using extra cement and joints filled with bituminous sealing compound grade 'A‘ complete all as specified and directed. |
| 102 | M&L hardcore of guage n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick using broken stone complete all as specified and directed. |
| 103 | M&L for 25mm thick cement concrete type B- 0 1:2:4 (12.5mm graded agg ) as in flooring complete all as specified and directed. |
| 104 | M&L machine cut Kota stone slab 18 to 20 mm thick as in flooring or trades of step incl half round moulding over and including screed bed 15 mm thick in CM (1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified. |
| 105 | M&L machine cut Kota stone slab 18 to 20 mm thick as in riser to step including 10 mm thick rendring in CM (1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified. |
| 106 | M&L for grinding and Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete. |
| 107 | M&L Baroda Green 15-17 mm thick (Table rubbed and polished) laid and jointed with grey cement slurry incl rubbing and polishing with granite finish over and including 15 mm thick CM 1:4 screed bed complete all as specified and directed.(Note: All exposed side of stone slab to be rounding) |
| 108 | ML for 18- 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 10mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 109 | M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in Sub base finished even and rough complete all as specified and directed. |
| 110 | M&L factory made rubber moulded coloured chequered tiles 30cm x 30cm x 22mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry as in floor including 15 mm thick screed bed in 1:4 complete all as specified and directed. |
| 111 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;. |
| 112 | M&L for providing and Laying Premium (1st) quality straight edge, ceramic tiles WA value between 3% to 6% , flexural strength greater than 22N/mm², scratch resistance on mohs scale greater than 4 and crazing resistance of 2 cycles in area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor, 8 to 10 mm thick in floors etc. in any shade and design/pattern of light & dark tiles etc as approved matching with wall tiles, set & jointed in neat cement slurry & pointed in matching colored polymer cement based grout to match including 15mm thick screed bed of CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 113 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete |
| 114 | Dismantling of brick or terracing tiles of single layers on roofs incl cleaning of bricks/tiles and removal of unusable bricks/tiles and removal from site, complete all as specified and as directed |
| 115 | Removing of Mud in roofs, any thickness, including plastering and leeping (whether full thicknes removed or only a part thereof) |
| 116 | Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified. |
| 117 | M&L for cement concrete 1:3:6 type C1 using 20 mm graded aggregate as in padding over roof, minimum thickness at khurra as 25 mm to maintain a slop of 1:100 complete all as specified and directed. |
| 118 | M&L for 10 mm thick rendering on top of roof in CM 1:3 incl mixed with WPC(WPC shall be paid separately) |
| 119 | M&L for wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc. complete all as specified. |
| 120 | M&L for APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3.6 Kg/Sqm black finish reinforced with non-woven polyster matt wt not less than 150 gms/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm torching over laps with a propane or a butan gas torch with a over lap of 75 mm at the side and 100 mm at the ends and sealing including applying a coat of cold emulsion bituminious primer all as per manufacturers instructions incl preparation of surface complete all as specified and directed. |
| 121 | S&F laying factory made, un-reinforced precast cement concrete tiles of size 250mm x 250mmx 22mm, machine pressed, as on roof surface, confirming to IS : 1237-1980, laid over and including 15mm thick screed bed in Cm 1:4, set jointed and pointed with grey cement slurry complete all as specified and directed. |
| 122 | Demolition of Concrete is reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for. |
| 123 | M&L for providing factory made precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in landings, perforated cover slabs(for manholes etc.,) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 all as specified and directed |
| 124 | Dismantling of Barbed wire fencing of any description and in any position complete. |
| 125 | Dismantling posts or struts (wood, steel or RCC) any section incl taking out embedded portion and making good disturbed ground (post embedded in PCC) |
| 126 | Excavation in post hole for similar holes each n exc 0.50Cum getting out returning filling in and ramming earth around in layers nexc 25 cm watering and removed surplus soil to a distance nexc 50m and making good surface in soft/loose soil. |
| 127 | M & L for cement concrete 1:3:6 type C2 using (40mm graded stone aggregate) as in foundation filling mass concrete complete all as specified |
| 128 | S&F mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh/welded steel wire fabric etc) including all necessary drilling, bolting or riveting etc, and similar work conforming to Fe-290 Gde E-165 |
| 129 | Supply only chainlink fencing any size any type etc complete all as specified and directed. |
| 130 | Fixing only chain link fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire. complete all as specified and directed. |
| 131 | S & F of mild steel screw bolt (machine made with hexagonal or square head at one end and screwed the other or screwed both ends each screw and to be fitted with washer and one hexagonal or square nut length of bolt n exc 5cm and dia of shank 5 to 10 cm complete |
| 132 | S & F 10 mm dia & over mild steel round or square bars Fe-410-W (Gde.E-250) quality-A orFe 290 (Gde -E-165)fixed behind chain link fencing as straining bars etc and similar articles complete as specified. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail