| 1 | SITC of outdoor type (Hooded) feeder pillar box (Double Door) all cover dimension (5'5\\"×4'6\\"×3') approx/suitable size to accomodate the following accessories having the body of the piller box made of 3.15 mm (10SWG) thick M.S. sheet and upper portion (hood) with 5 mm thick M.S. plate and continuously welded having vent at the top and upper side of P.B. with 4 Nos. leg by 50 x 50 x 6mm with two Nos. earthing arrangement. Inside pillar box should be provided with 1\\" thick wooden plank of suitable size of 50mm × 50mm × 6mm welded inside the wall of the P.B. with railway type locking arrangement with provision of handle and S&F 7(seven) lever Godrej pad lock with duplicate keys. Provision should be made for incoming and outgoing cables incl. 2 coats of alluminium painting the P.B. with two coats of R.O. primer (Inside also) as per direction of E.I.C.The pillar Box should be provided with cubicle type LT panel board having the following accessories: |
| 2 | Supply and Installation of L.T. cubical type fully compartmentalized distribution panel boars, having rigid and self supporting structure fabricated with 14 SWG CRC sheet with M.S. angle iron frame (main frame with 50 x 50 x 6mm angle and each compartment with 40 x40x 6 mm angle iron ). The base of panel should be made with 75 mm x 40mm x 4.4 mm M.S. channel . Each compartment will be providing with hylam board at back side. |
| 3 | INCOMING:a) 415V, 250A TPN SFU with 3 Nos. DIN type HRC fuse (Make- L&T/ ABB/ Siemens) ---1 Setb) 415V, 250A TPN on load front operated Changeover cum swith necessary arrangement as per direction of EIC. (Make- L&T/ ABB/ Siemens) ---1 Set. |
| 4 | BUSBAR: 415V, 415Amp 4 nos 4 x 50 x 5 mm (Dimension of Sheet Metal Box copper bus-bar with necessary nos of holes and different colour insulating tape on epoxy bus support.- 01 set |
| 5 | OUTGOING:1. 415V 125A TPN SFU with 3 Nos. DIN type HRC fuse (Make- L&T/ ABB/ Siemens) ---2 Nos 2. 415V 63A TPN SFU with 3 Nos. DIN type HRC fuse (Make- L&T/ ABB/ Siemens)---2 Nos. |
| 6 | METERING:(i) 0-500 V digital volt metre (AE or L&T make) with inbuilt selector switch.- 01 set(ii) 0-250 Amp Digital Ammeter (AE or L&T make) with inbuilt selector switch and 3nos 250/5 amp CT(Cl-1, 5VA) (Make- cuppa)- 01 set(iii) RYB indicating lamp (Siemens or L&T make) complete with sliding fuse- 03 Nos(iv) EI danger board (6\\"x4\\") - 02 Nos(v) 6A Sliding lock fuse 6 nos. for meter & indication lamp protection. |
| 7 | PAINTING: The complete panel board is to be spray painted after required surface treatment with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating. |
| 8 | INSTALLATION:The feeder piller is to be installed after digging out required soil with necessary C.C. muffing to be made arround 4 legs. A guard wall of 10\\" thick to be constructed around the periphery of the piller box and bottom of the piller to 2'6\\" above Gr. Level the brick wall must be plasterd with net cement funish as per direction EIC. |
| 9 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.i) 415V, 160A Bus, 6 Way VTPN DB - 1 no.ii) I/C - 415V, 125A, 25kA/35kA FP MCCB (adjustable thermal and fixed magnetic setting) -1 no.iii) O/G - 415V, 63A, 10kA TP MCB ('C' Curve) - 6 nos.[Make - Siemens/ Legrand/ Schneider] |
| 10 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for 6way TPN DB Vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. [Make - Siemens/ Legrand/ Schneider] |
| 11 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmenti) 6 way HTPN DB - 1 no.ii) I/C - 415V, 63A FP MCB type Isolator -1 no.iii) O/G - 240V, 6-32A SP MCB (C-Curve) -18 nos.[Make - Siemens/ Legrand/ Schneider] |
| 12 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.i) 2+12 way SPN DB - 1 no.ii) I/C - 240V, 40A DP MCB type Isolator - 1 no.iii) O/G - 240V, 6-16A SP MCB - 12 nos. [Make - Siemens/ Legrand/ Schneider] |
| 13 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper barincl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages tooriginal finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 14 | a) Average run 8 mtr. |
| 15 | b) Average run 10 mtr. |
| 16 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.On Board |
| 17 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.19 mm dia 3 mm thick polythene pipe without earth continuity wire. |
| 18 | Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.25 mm dia 3 mm thick polythene pipe without earth continuity wire. |
| 19 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. |
| 20 | a) 2×36/0.3 (2.5 mm²) + 1×22/0.3 (1.5 mm²) as ECC [For 1×16A & 2×16A Power Socket] |
| 21 | b) 2×56/0.3 (4.0 mm²) + 1×36/0.3 (2.5 mm²) as ECC [For AC] |
| 22 | c) 2×84/0.3 (6.0 mm²) + 1×56/0.3 (4.0 mm²) as ECC [Walk-in-Cooler & Lift] |
| 23 | d) 4×126/0.4 (16 mm²) + 2×80/0.4 (10 mm²) as ECC [VTPNDB to HTPN DB] |
| 24 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 25 | a) 2×2.5 + 1×1.5 mm² |
| 26 | b) 2×4.0 + 1×2.5 mm² |
| 27 | c) 2×6.0 + 1×4.0 mm² |
| 28 | d) 4×16 + 2×10 mm² |
| 29 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 30 | Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S&F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 31 | Supply & Fixing 240V, 25A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [AC Socket] |
| 32 | Supply & Fixing 240V, 25A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 33 | Supply and delivery of Single LED Fitting with all accessories (Make- Philips, Cat No.- TMC 502 1xT-LED 22W/ Wipro) and 1 nos LED Tube, 105 ≤ Luminious efficacy < 120 Lumen/watt. The LED Luminaries & accessories should have BEE certification. (Make- Philips, Cat No- Mas LEDTube 1200mm 18W 865 T8I-2100lm/ Wipro/ Crompton) |
| 34 | Supply and delivery of Twin LED Fitting with all accessories (Make- Philips, Cat No.- TMC 502 2xT-LED 22W/ Wipro) and 2 nos LED Tube, 105 ≤ Luminious efficacy < 120 Lumen/watt. The LED Luminaries & accessories should have BEE certification. (Make- Philips, Cat No- Mas LEDTube 1200mm 18W 865 T8I-2100lm/ Wipro/ Crompton) |
| 35 | Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required. |
| 36 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 37 | Extra for suspension exceeding 25 cm with S&F additional 2 nos. 20 mm dia E.I. Conduit (14 SWG) support as per G.S & necy. PVC insulated copper wire and painting etc, as per required. |
| 38 | Supply & delivery of 1200 mm sweep 230 volt AC Ceiling fan incl. Blades, canopy etc. With 18\\" down rod(14SWG), Fork (10SWG), Heavy type insulator, 3/8th inch bolt with nut, heavy type split pin etc.with safety wire & PS2 type capacitor, as directed by EIC. (Make- Orient- New breeze/ Crompton- High Speed(HS)/Usha Striker PWD(1STAR) |
| 39 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. |
| 40 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. As per GS |
| 41 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) |
| 42 | Supply of 230V , 50Hz , 450 mm sweep heavy duty full metal body wall bracket fan (Cabin fan) complete with all accessories. ( Make -Orient Model No. - toranto wall -II Gun Metal /Eqiuvalent model of crompton & Usha ) |
| 43 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. |
| 44 | Supply and delivery of 230V 300mm (12\\") Exhaust fan with all necessary accessories, as directed by EIC.[Make: EPC Heavy Duty] |
| 45 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 46 | b) 30 cm (12\\") |
| 47 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 48 | b) For 30 cm (12\\") Exhaust fan |
| 49 | S & F of 240V double door AC Timer DB [equivalent of 2+14 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCB, 2 no. 25A SPMCB ('C' curve 10KA), 1no. Programmable Digital time switch-24 hrs with minimum switching of 15 minutes, and 2 no. 25A 2-Pole power contractor with inner-outer plate & internal wiring by 4sq mm. cu. wire incl. 2 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. 2 nos. LED indication light for running condition of both AC with mechanical locking arrangement, as directed by EIC.(For AC) [Make-ABB/ L&T/ Crabtree] |
| 50 | Supply & Delivery 1.1KV grade Al/XLPE/STA/PVC multi starnding cable as per choice of EIC. (Make - Polycab / Havells / RR Kabel / Gloster / KEI) |
| 51 | a) 4 core 70 mm² (From New Feeder piler to VTPN) |
| 52 | b) 4 core 120 mm² (From Panel to New Feeder Piler) |
| 53 | Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 54 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. |
| 55 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: |
| 56 | a) 4 core 70 mm² |
| 57 | b) 4 core 120 mm² |
| 58 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 59 | a) 4 core 70 mm² |
| 60 | b) 4 core 120 mm² |
| 61 | Earthing with 50mm dia GI pipe (ISI-M) 3.64mm thick x 3.04 Mts. long and 1x4 SWG GI (Hot Dip) wire (4 Mts. long), 13mm dia x 80mm long GI bolts, double nuts, double washers incl. S&F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under-ground level and partly above-ground level driven to an average depth of 3.65 Mts. below the ground, as per GS. |
| 62 | Excavation of soil for installation of Earth Electrode and filling & ramming, for morrum Soil, as per GS. |
| 63 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia. holes on the GI pipe |
| 64 | S&F earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd., as per GS. |
| 65 | Connecting the equipments to earth busbar incl. S&F 2x8 SWG GI (Hot Dip) wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as reqd. & mending good damages as per GS. |
| 66 | Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 67 | Supply & Delivery of Concealed split Room Air Conditioner 2.0 Ton capacity having the following specification : Compressor Type: Rotary, Rated Cooling Capacity (Watts): 6600, EER-3.14, Rated Power supply: 230V, Rated powe input: 2100W, 50Hz, Air volume for indoor unit(CFM): (618-953), Nano Platium filter, powerful cool and wide & long airflow Air Sleep Cooling Technology, LCD remote control, Electronic metal housing box, 12 hour on and off timer, auto restart, Refrigerant-R32. (Make: Mitsubishi Electric India Pvt Ltd., Model No- PE-M24JAK-DA+PU-M24VAK-DA/ O-General/ Mitsubishi Heavy Industries) |
| 68 | Installation testing & commissioning of above AC machines at 1st floor by fixing the indoor with two number 1.0 mt long MS \\"C\\" channel of sizes 65mm × 32mm × 6mm with minimum 6nos. 10mm × 75mm anchor fastner bolt drilled into the ceiling. The indoor unit suspended from this \\"C\\" section support with 4 nos. 10mm full threaded suspender bolt with double nut & spring washer. (Out door unit will be fixed on pre fabricated MS platfrom on 2nd floor height.) [All MS Structure should be painted with one Coat of good Quality red oxide paint and 2 Coat of enamel Paint and all nut,bolt and washer should be stainless steel grade] |
| 69 | Supply & Fixing of Refrigerant Copper pipe of following diameter for connecting of Indoor to Outdoor unit, along with drip resistant nitrile rubber insulation with double insulating wrapping tape to avoid dripping of condensate water:- |
| 70 | Discharge Line 6.35mm dia, min. thickness 0.8mm with 9mm thick nitrile insulation. (Make : Rajco / Mandev). |
| 71 | Suction Line 15.88mm dia, min. thickness 0.99mm with 9mm thick nitrile insulation. (Make : Rajco / Mandev). |
| 72 | Supply & Laying of PVC insulated unarmoured 1.1 KV grade 4 Core 2.5 mm² copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells) |
| 73 | Wrapping the both copper pipe with insulation & electric cable by wrapping tape as per direction of EIC |
| 74 | Supply & Fixing drain Water piping work with 32 mm dia Schedule 40 PVC / UPVC hard pipes (Finolex / Ashirbad / Supreme) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. insulated with 9mm. thick nitrile rubber tube insulation. |
| 75 | S & F flexible canvas connection for indoor to duct/ air terminal for a) 7KW indoor |
| 76 | SITC of Powder Coated Al. Grill without VCD suitable size (Make:Systemair / Primier) |
| 77 | Supply & Fixing drop ceiling to cover the indoor units & supply air duct including the cost of 3mm thick ACP sheet as per manufacturer's specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm × 25mm (2mm thick) & duly suspended by Aluminium hollow rectangular section of size 50mm × 38mm (2mm thick) and silicon sealent complete in all respect including making trap door arrangement as per direction of EIC. (Make:Aludecor/Pratapbond) |
| 78 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.I) For structural members of specified sections weighing less than 22.5 Kg./m (Necessary Fabricated ladder, Red oxide and enamel Painting, Brick Wall cutting, Grouting and Masionary work for making AC outdoor unit platfrom) |
| 79 | Add GST @ 18% on Item no 1 to 51 |
| 80 | Add CESS @ 1% on Item no 1 to 52 Please Enable Macros to View BoQ information |