| 1 | SUB-HEAD -1-DISTRIBUTION WIRINGistribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm)single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl.175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 2 | Average run 8 Mtr |
| 3 | Average run 10 Mtr |
| 4 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish |
| 5 | Average run 8 mtr |
| 6 | Average run 9 mtr |
| 7 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish |
| 8 | On Board |
| 9 | Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. |
| 10 | 19 mm dia 3 mm thick |
| 11 | 25mm dia 3 mm thick |
| 12 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy.connection as. (Make - Finolex/Polycab/Havells) |
| 13 | 2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [for SPNDB to (6+6A)plug] |
| 14 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [for SPNDB to Computer points & , 16 A plug] |
| 15 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [for circuit wiring from TPNDB to AC circuit ] |
| 16 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [for TPNDB to SPNDB] |
| 17 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as per GS. |
| 18 | 1.5sqmm |
| 19 | 2.5sqmm |
| 20 | 4 sqmm |
| 21 | 6 sqmm |
| 22 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS |
| 23 | a)200 x 150 x 65 |
| 24 | b)240 x 200 x 65 |
| 25 | c)240 x 200 x 65 |
| 26 | SUB-HEAD -2-PLUGS & SOCKETSS&F 240V, 2 nos. 6A, 3 pin Modular type plug socket (Brand approved by EIC) with 2 nos. 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Legrand- Arteor /Myrius /Honeywell Mk-Wraparound/Anchor-Roma) [6A+6A Combo Baord Plug].As per direction of EIC. |
| 27 | Supply & Fixing 240 V, 16A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Legrand- Arteor /Myrius /Honeywell Mk-Wraparound/Anchor-Roma) [Sep 16A Plug]. |
| 28 | S&F 240V, 3nos. 6 Amp, 3 pin Modular type plug socket with 3nos. 6A Modular type switch, 1no. 16A 3pin Modular type socket & switch, 1no.C16 SP type modular MCB & 1no. indicator (Brand approved by EIC) without plug top on 18 Module GI Modular type switch board 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Legrand- Arteor /Myrius /Honeywell Mk-Wraparound/Anchor-Roma) [Computer Plug]. As per direction of EIC. |
| 29 | Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Legrand- Arteor /Myrius /Honeywell Mk-Wraparound/Anchor-Roma) |
| 30 | SUB-HEAD -3-BDB,PDB,VTPN ETCSupplying and fixing 6 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, concelled in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [415V, 160A, 35 kA, FP MCCB with adjustable thermal & fixed magnetic setting as incomer - 1 no. & 415V, 63A, 10 kA C-curve, TP MCB as outgoing - 6 nos.] (Make - L&T/Legrand/ Siemens). |
| 31 | Supplying and fixing double door sheet steel(16SWG), powder coated cable end box for vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the amages to original finish with nuts bolts etc incl. provision for earthing attachment.6 Way |
| 32 | Supplying and fixing 8 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, concelled in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [415V, 160A, 35 kA, FP MCCB with adjustable thermal & fixed magnetic setting as incomer - 1 no. & 415V, 63A, 10 kA C-curve, TP MCB as outgoing - 8 nos.] (Make - L&T/Legrand/ Siemens) (For new court building) |
| 33 | Supplying and fixing double door sheet steel(16SWG), powder coated cable end box for vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the amages to original finish with nuts bolts etc incl. provision for earthing attachment.8 Way |
| 34 | Supply & fixing 415 Volt 16 - 32 Amp per way 6way HTPN MCB DB with SS enclosure double door with IP-42/43 protection with 63 Amp. 4P MCB Isolater as incomer and 18 nos. 6-32 A SP MCB ('C' Curve, 10 KA) as outgoing concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size Cu. wire and neutral link & provision for earthing attachment as to G.S. (Make - L&T/Legrand/ Siemens). |
| 35 | Supply & fixing 415 Volt 16 - 32 Amp per way 8 way HTPN MCB DB with SS enclosure double door with IP-42/43 protection with 63 Amp. 4P MCB Isolater as incomer and 24 nos. 6-32 A SP MCB ('C' Curve, 10 KA) as outgoing concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size Cu. wire and neutral link & provision for earthing attachment as to G.S. (Make - L&T/Legrand/ Siemens). |
| 36 | Supply & Fixing 2+8 way, 250V, 6-10A per way, SPN MCB DB with SS enclouser(A9HSND06) double door with IP- 42/43 protection with 40A DP MCB Isolator as incomer and 8 nos 6-32 A SPMCB ('C' Curve, 10KA) as outgoing concealed in wall after cutting the wall and mending the good damages to original finish incl. inter connection with suitable size Cu wire and neutral link & provision for earthing attachment as to G.S. (Make - L&T/Legrand/ Siemens). |
| 37 | Supply & Fixing 2+10way, 250V, 6-10A per way, SPN MCB DB with SS enclouser(A9HSND06) double door with IP- 42/43 protection with 40A DP MCB Isolator as incomer and 10 nos 6-32 A SPMCB ('C' Curve, 10KA) as outgoing concealed in wall after cutting the wall and mending the good damages to original finish incl. inter connection with suitable size Cu wire and neutral link & provision for earthing attachment as to G.S. (Make - L&T/Legrand/ Siemens). |
| 38 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD SpecificationBook – May 1991 |
| 39 | 4 bars,415 V, 415 A,Dimension of Aluminium. Bars [400mm long]4 x 65x13mm&Dimension of Sheet Metal Box,600x500mm |
| 40 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Make- Siemens / L&T / as per direction of EIC] 350 A |
| 41 | Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [Make- Siemens / L&T/ as per direction of EIC].350A |
| 42 | LT PANEL FOR RAW POWERSupply and installation of L.T. cubical type fully confirming to IEC 60439 upto date ammendments compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each compartment with 40x40x6 mm angle iron). The base of panel should be made with 75mm x 40mm x 6mm M.S. channel. Each compartment will be providing with hylam board at back side. The panel should have cable alley at both side of panel. |
| 43 | A : INCOMING ARRANGEMENT |
| 44 | S&F 415V, 920 Amps TPN switch disconnector fuse with 3 nos 320A HRC fuse –1 No. (Make Siemens/ABB/L& T) S&F 415V, 320 Amps TPN changeover switch disconnector fuse with 3 nos 300A HRC fuse –1 No. (Make Siemens/ABB/L& T) |
| 45 | B : BUS SECTION |
| 46 | 415 Volts, 415 Amp capacity Copper bus bar(4 bar) [size of flat (4x 20 x 5 mm) / Equivalent size] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification-1 Set |
| 47 | C : OUTGOING ARRANGEMENT |
| 48 | a) 415V, 250A TPN Switch Disconnector Fuse unit with 3 nos. HRC Fuse (Make–L&T/ABB/Siemens-Front handle) - 4 Nos.b) 415V, 200 A TPN Switch Disconnector Fuse unit with 3 nos. HRC Fuse (Make–L&T/ABB/Siemens-Front handle) - 1 Nos.c) 415V, 63A TPN Switch Disconnector Fuse unit with 3 nos. HRC Fuse (Make–L&T/ABB/Siemens-Front handle) - 2 Nos. d) E.I. Danger Board of suitable size -1No. |
| 49 | D : METERING PANEL |
| 50 | A digital multifunction meter. (Make L&T Cat No.- MFM 4405 LED meter CI 1) |
| 51 | i) 0-999 V Digital voltmeter(AE make) with selector switch (Kayee make)--- 1 set |
| 52 | ii) 0-999 A Digital ammeter(AE make) with selector switch (Kayee make)--- 1 set |
| 53 | iii) 200/5 Amp ratio C.T (Kappa) --- 3 nos. |
| 54 | iv) sliding fuse –3nos |
| 55 | v) 230V RYB. LED indicator lamp (Siemens/L&T)-- 3 nos incl. interconnection |
| 56 | E : INTER - CONNECTION |
| 57 | All interconnection from incoming main switch To BBC & BBC to All outgoing main switch shall be made with suitable sizes (50 x 5) of copper strip / suitable size single core copper wire having marked ferrule for indication with rapping with proper ampere tape or heat sink tape and also colour indicated per phase by pvc tape. |
| 58 | F : CABLLING DIAGRAM |
| 59 | Cable allay arrangement will be provided in the cubicle panel in horizontal position with 400 Amp Capacity bakelite 4 way AC / DC Make connector indicating 3 phase & neutral for each outgoing main switches cable & also incoming. |
| 60 | G : PAINTING |
| 61 | The complete panel board shall be painted podwer coating paint, colour siemens gray. |
| 62 | H : EARTHING |
| 63 | A separate continuous GI earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the panel board. All electrical equipment are to be properly earthed with suitable size G.I. wire |
| 64 | I : CONSTRUCTIONAL DETAILS |
| 65 | All Incoming & Outgoing Panel mounted cubicle switch disconnector fuse shall be housed in respective compartment with hinged and gas keted door at front. The rear panel shall have gaketted wire net guard for ventilation and arrangement shall be made for easy accissibility to each compartment by providing rear panel door with locking system. The panel shall be properly gasketed to prevent ingress of dust and moisture and vermin. All horizontal bus bar chamber shall be properly arrange and all electrical switches and bus bar shall be fixed by M.S. nuts & bolts on angle / flat iron frame base. The outgoing feeder connection from respective switch shall be made at rear side of panel with proper identification as per direction of E.I.C. The complete panel board is to be installed on suitable brick padestal incl. net cement finish as directed by the E.I.C. |
| 66 | J : T&C |
| 67 | Vendor have to submit four (4) set for each of GA drawing & Control circuit wiring dragam. |
| 68 | SUB-HEAD 3-- SUPPLY & LAYING OF CABLES Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Fort Gloster/polycab/KEI/RR Kable] |
| 69 | 4 Core 25 Sq. mm (from VTPN to HTPH DB ) |
| 70 | 4Core 70 Sq. mm ( from Pannel to VTPN ) |
| 71 | 4 Core150 Sq. mm ( From Busbar to Pannel & Pannel to DGPannel) |
| 72 | Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. |
| 73 | 200x50x1.25mm (18SWG) |
| 74 | 300x50x1.25mm (18SWG) |
| 75 | Laying of cable as below, on existing Cable Tray and binding withsuitable size GI wire. |
| 76 | Up to 50 sqmm |
| 77 | From 70sqmm to 150sqmm |
| 78 | Laying of cable upto 4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 79 | Laying of cable From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. after cutting floor/pavement/wall/ andmaking holes incl., embedding the cable with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wireat an average depth as below and mending good the damages to original finish incl. removing the rubbish |
| 80 | Laying of cable 4 core 70 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 81 | Laying of cable Above 35 sqmm to 95 sqmm at an average depth of 100 mm in after cutting floor/pavement/wall/ and making holes incl., embedding the cable with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wireat an average depth as below and mending good the damages to original finish incl. removing the rubbish |
| 82 | Laying of cable of 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and paintin |
| 83 | Laying of one No. cable of 4 core 25 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
| 84 | Laying of one No. cable of 70 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed . |
| 85 | Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable 4 Core as per GS. |
| 86 | 4 Core 25 Sq. mm |
| 87 | 4Core 70 Sq. mm |
| 88 | 4Core 150 Sq. mm |
| 89 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS. 40mm dia. |
| 90 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS. 100 mm dia. |
| 91 | SUB-HEAD 4 -SUPPLY & FIXING OF LIGHT FITTINGSSupply & Delivery of 4 feet single commercial LED type fluorescent light fittings complete with all accessories similar to Philips make cat No. TMC 502 P1 x T - LED 22 W P3 241 with Master LED Tube lamp of 1200 mm , 18W 865 T 81- 2100 ln corresponding to Philips / Magic / Crompton/ Havells/PWD approved. As per direction of EIC. |
| 92 | Supply & Delivery of 4 feet twin commercial LED type fluorescent light fittings complete with all accessories similar to Philips make cat No. TMC 502 P2 x T - LED 22 W P3 241 with Master LED Tube lamp of 1200 mm , 18W 865 T 81- 2100 ln corresponding to Philips / Magic / Crompton/ Havells/PWD approved. As per direction of EIC. |
| 93 | Supplying & Fixing angular holder (Anchor) on 3\\" wooden double round block incl. S&F 9 Watt LED lamp (Make Philips / Wipro / Bajaj / Crompton/ Havells / PWD Approved ) as per direction of EIC. |
| 94 | Supplying & fixing pressure die cast housing 220V 10W LED bulkhead with IP66 protection and IK09 impact resistance suitable (cat no- WT202W LED 10S CW PSU S3 PC) (Make Philips / Magic/ Havells/PWD approved. As per direction of EIC. |
| 95 | Fixing only single/twin fluorescent light fitting in the ceiling fixed with “L” type MS clamp incl 2nos 20mm Dia EI Conduit |
| 96 | Fixing only florescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl 2 nos 20mm dia EI Conduit (14 SWG) |
| 97 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS . |
| 98 | Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling With HW Block & Suitavble MC Fastener Ceiling Plate required |
| 99 | SUB-HEAD 5 -- SUPPLY & FIXING OF FANSSupply & delivary of AC 240V 50 Hz 48\\" sweep (1200 mm) ceiling fan complete with down rod , Canopy, fork , Sefty wire incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor (supplied at the time of delivered the fans ) etc. with out regulator, (Make- Usha (Striker PWD 1 Star) / Crompton Greaves (AURA Prime Anti Dust 1 star)As per direction of EIC as per direction of EIC. |
| 100 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per direction of EIC as per direction of EIC. |
| 101 | Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by after making housing for regulator by cutting bakelite top cover incl. making necy. connections etc. as per G.S. . |
| 102 | Supply & Delivery of 230 V, 50 Hz, following sizes metal body heavy duty exhaust fan. Make: EPC / Usha Fans(cat no. 230 MMAEROCLEAN PLUS DBB GBD/30O MMAEROCLEAN PLUS DBB GBD)/ Crompton(225mm TRANSAIR(Double ball bearing)/300mm TRANSAIR(Double ball bearing)) or any approved and recognised brand by EIC.. |
| 103 | 9\\" (230mm/225mm) 1370 RPM |
| 104 | 12\\"( 300mm ) Speed 1370 RPM |
| 105 | Supply & fixing of Wall Bracket Fan fans complete with all accessories having the following Model / Cat No. ( Make O-rient/Crompton Greaves/Usha ) |
| 106 | 450 mm (18\\") Make Orient( Model:Tornado wall II |
| 107 | Fixing only exhaust fan after making hole in wall and making gooddamages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 108 | 9\\" (230mm) 1370 RPM |
| 109 | 12\\"( 300mm ) Speed 1370 RPM |
| 110 | Supply & Fixing AL louver shutter on wall with necy. bolts & nuts (6mm dia x 62 mm long) |
| 111 | 230 cm Exhaust fan (9\\") |
| 112 | 30 0cm Exhaust fan (12\\") |
| 113 | Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil . |
| 114 | SUB-HEAD 7 -- EARTHING Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below With TATA-Medium GI pipe as per GS. |
| 115 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 116 | Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS. 4 SWG |
| 117 | SSupplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 118 | SUB-HEAD 8 -- MISCELLANEOUSDismantling the existing damage , defective & non functioning Electrical accessories by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC. and the agency have to submit the dismantled Electrical Installations at theHospital Authority by their own arrangements with full list of items by 3 nos Semi Skilled person & 06 nos Unskilled Person. |
| 119 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS. |
| 120 | S & F 240V 21A OLP - 30 Electrronic motor starter in 175mm X 100mm X 65 mm depth 16 SWG MS Box coneled in wall with bakelite top cover incl. Necy. Conncetion as per direction of EIC for AC Machines |
| 121 | S&F sheet metal 2 module Anodised box in conceal in wall incl S & Fbase & top incl S & F 25A capacity 5 pin base & Top North Make and earthing attachment as per G.S.. |
| 122 | Shifting of 2Tr split type AC from one place to another place with all necesery equipment and filling wall hole with cement and sand mixture, as per direction of EIC. (Dismantaling and reinstallation charge are included). |
| 123 | Providing masonary platform for placement of pannel, size L=250mm, W=66 mm, Height=70 mm(Above GL) rectangular shaped to be made with 5\\" Brick soling, 10 brick wall in 4 four sides, sand filling the chamber and 5\\" RCC top single layer (M20 grade) with 3 mm thick neatly finished cement plaster all round as per G.S. |
| 124 | Timer Panel:Supplying and fixing (2+12)way Legrand DB enclosure for housing the following A) One no.single dial digital timer (Legrand) B)One no. FP pole, conctractor 40 AMP,(LEGRAND) C) One no. FP 32A TP MCB (Legrand) D) One no. auto/manual Toggel Switch and other required material The complete arrangement must be wiring by PVC insulated Cu wire as per GS |
| 125 | AQUICKBROWNFOXJUMPSRIGHTOVERTHELEASYDOG Please Enable Macros to View BoQ information |