| 1 | Total Amount |
| 2 | Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor. |
| 3 | 1st Floor |
| 4 | 2nd Floor |
| 5 | 3rd Floor |
| 6 | 4th Floor |
| 7 | 5th Floor |
| 8 | 6th Floor |
| 9 | 7th Floor |
| 10 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.Ground Floor |
| 11 | 1st Floor |
| 12 | 2nd Floor |
| 13 | 3rd Floor |
| 14 | 4th Floor |
| 15 | 5th Floor |
| 16 | 6th Floor |
| 17 | 7th Floor |
| 18 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.Ground Floor |
| 19 | 1st Floor |
| 20 | 2nd Floor |
| 21 | 3rd Floor |
| 22 | 4th Floor |
| 23 | 5th Floor |
| 24 | 6th Floor |
| 25 | 7th Floor |
| 26 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar b) 20 mm thick plaster Ground Floor |
| 27 | 1st Floor |
| 28 | 2nd Floor |
| 29 | 3rd Floor |
| 30 | 4th Floor |
| 31 | 5th Floor |
| 32 | 6th Floor |
| 33 | 7th Floor |
| 34 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINLGround Floor |
| 35 | 1st Floor |
| 36 | 2nd Floor |
| 37 | 3rd Floor |
| 38 | 4th Floor |
| 39 | 5th Floor |
| 40 | 6th Floor |
| 41 | 7th Floor |
| 42 | Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 of approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge.for leaf width upto 1100mm |
| 43 | Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in- Charge fitted and fixed complete including all incidental charges. |
| 44 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 45 | Painting with ready mixed red lead paint of approved make and brand :(b) Two coats Total |
| 46 | Add GST @ 18% Total |
| 47 | Add Labour Welfare Cess @ 1% |
| 48 | Supplying,Installation of GM/ S.S. branch pipe with 20mm.Nozzel conforming to IS: 903 . |
| 49 | Supplying, & Installtion of 63 mm dia reinforced rubber line hose pipe in 15 m length including to IS.636 Type A ISI Marked with GM/SS Male and female instantaneous coupling conforming to IS 903 Wounded with 18 SWS Copper Wire. |
| 50 | Supplying, Insatattlation of automatic 25 NB Air Release Valve. |
| 51 | Supplying & installation of dial type Pressure gauge of suitable pressure range, fitted with dampner arrangement and isolation ball valve ass hown in respective drawing .The dlameter of dtal shall be 150 mm preferably filled up with glyserine. All other necessary fitting to be supplied to erect the gauge on top of the riser. |
| 52 | Supplying,Installation of Globe Valve in Bronze Construction to IS :778 with screwed ends 25 NB size. |
| 53 | Supplying,installation testing &commissioning of CI Butterfly valve as per BS: 5155.(Wafer type) With matching flanges ,nuts&bolts and gasket.150mm NB. |
| 54 | Supplying, installation of GM/SS oblique type single headed Hydrant valve 80 mm inlet and 63 mm outlet GM/SS Instantaneous male coupling with rubber cap and chain conforming to IS;5290 Including Matching Flanges ,Gasket ,nuts and bolts . |
| 55 | Supplying & installing of GM/SS 3 way fire Brigade inlet with 63mm dia instantaneous type coupling and 150 dia flanged outlet .Each inlet coupling shallbewith built in check valve The inlets shall comform IS 904. The inlet connection shall be mounted on external network. |
| 56 | Supplying & installing of Hose box ,fabricated from 16 SWGCRCA sheet double door with lockble arrangements to accommodate 2 RRL hose of 15 m lenth and one branch pipe painted white inside and red outside with one key (750x600x250 mm). |
| 57 | Supplying , installing ,testin & commissioning of CI Sluice valve as per IS: 14846 (PN 16), Rising Spindle type with matching flanges complete with nuts &bolts Size 150 mm NB. |
| 58 | Supplying, erection & fixing of heavy grade (class-C )pipes conforming to -IS 1239/IS-3589 including all fittings viz. tees,elbows, union,flanges, rubber gaskets, GI nuts bolts, washer and structural steels for pipe supports .Hanger support with anchor fasteners and clamps shall be supplied to fix the pipes on ceiling wall etc.including supporting/fixing the pipe on floor/wall /ceiling with clamps ,hangers (using anchor fastners )as per especification . cutting fioors ,walls etc. and making it good after erection of pipe shall be of vendors' scope.Necessary painting with (2)two coats of primmer and 2(two) coats of synthetic enamel paints to be done and supply of paints shall be with vendor's scope. (Make- TATA/JINDAL)200 mm NB X 6 mm . |
| 59 | 150 mm NB |
| 60 | 100 mm NB |
| 61 | 80 mm NB |
| 62 | 65 mm NB |
| 63 | 50 mm NB |
| 64 | 25 mm NB |
| 65 | Supplying, & installation of SS sprinkler head K-80, chrome finish.Pendent type. |
| 66 | Supplying, fixing and Testing of ABC dry powder (Stored Pressure) Fire Extinguisher ISI Marked, of 6 kg. Capacity consisting of Welded cylinder squeeze lever discharge valve fitted with pressure indicating gauge,internal discharge tube, discharge nozzle suspension bracket, with ISI Marked Mono Ammonium Phosphate base (50%) ABC Powder conforming to IS;4308:2019 (W.E.F.16.07.19.) and pressurized with Nitrogen Gas, suitable for operating between -30 degree C to +60 degree C minimum, Fire Rating Class -3A & 89B. The colour of the extinguisher body should be PO Red conforming to shade 538 of IS 5 with Blue Colour Sticker pasted to indicate Power type for easy recognition. The Complete Extinguisher should conform to IS: 15683 : 2018 & should be maintained as per IS:2190:2024 Code of Practice. Extinguishers to be Refilled / Hydro test for performance once in 5 years. A Polyester with 3D hologram label of OEM(Original Equipment Manufacturer) should be pasted on the body of the extinguisher showing:1. Supplied by: PWD2. Date of manufacture:3. Date of expiry / date of next filling:4. Serial No:5. Brand Name: (Minimax/Ceasefire/Safex/Fire Shield.) |
| 67 | Supplying, fixing and Testing of ISI Marked CO2 type (Conforming to IS:15222:2002) Fire Extinguisher 4.5 kg capacity conforming to ISI: 15683:2018 made from seamless cylinder confirming to IS: 7285 duly approved by Chief Controller of Explosive, Nagpur, fitted with ISI Marked Controlled Valve conforming to IS:3224, high pressure 1 mtr. long discharge hose and horn with shock proof rubber grip to prevent from frost bite while operating, complete with initial gas charged with carrying handle wall mounting bracket, suitable for operating between -30 degree C to 60 degree C minimum, Fire Rating Class-34B. The colour of the extinguisher body should be PO Red conforming to shade 538 of IS 5 with Black Colour Sticker pasted to indicate CO2 type for easy recognition. The Complete Extinguisher should conform to IS: 15683 : 2018 & should be maintained as per IS:2190:2024 Code of Practice. Extinguishers to be Refilled / Hydro test for performance once in 5 years.A Polyester with 3D hologram label of OEM (Original Equipment Manufacturer) should be pasted on the body of the extinguisher showing:1. Supplied by: PWD2. Date of manufacture:3. Date of expiry / date of next filling:4. Serial No:5. Brand Name:(Minimax/Ceasefire/Safex/Fire Shield.) |
| 68 | Refilling of Fire Extinguisher 6.0 kg ABC type in conformity with the IS 2190 : 2024 code of practice. It is mandatory to recharge the extinguisher by manufacturer or authorized agent of manufacturer of the existing fire extinguishers brand in conformity with IS 15683 : 2018. Note that the certificates for satisfactory refilling have to be furnished from the manufacturer or its authorized agent at the time of supplying of the refilled fire extinguishers. All other statutory markings/levelling have to be done as per IS-2190 : 2024 code of practice. Extingusihers to be refilled / hydro test for performance test once in 5 years.A Polyester with 3D hologram label should be pasted on the body of the extinguisher showing1. Supplied by: PWD2. Date of refilling:3. Date of expiry / date of next filling:4. Refill Identification No/Serial No5. Brand / rating of Fire Extinguisher to be refilled: Fire Shield/Ceasefire / as per the Existing brand. |
| 69 | Refilling of Fire Extinguisher 4.5 kg CO2 type in conformity with the IS 2190 : 2024 code of practice. It is mandatory to recharge the extinguisher by manufacturer or authorized agent of manufacturer of the existing fire extinguishers brand in conformity with IS 15683 : 2018. Note that the certificates for satisfactory refilling have to be furnished from the manufacturer or its authorized agent at the time of supplying of the refilled fire extinguishers. All other statutory markings/levelling have to be done as per IS-2190 : 2024 code of practice.Extingusihers to be refilled / hydro test for performance test once in 5 years.A Polyester with 3D hologram label should be pasted on the body of the extinguisher showing:1. Supplied by: PWD2. Date of refilling:3. Date of expiry / date of next filling:4. Refill Identification No/Serial No5. Brand / rating of Fire Extinguisher to be refilled: Fire Shield/Ceasefire / as per the Existing brand. |
| 70 | Supply & installation of hose drum reel fabricated from 16 SWG CRCA Sheets painted with red colour stove paint 2 coats over 1 coat of primer. The length of the hose shall be 30 m with 20 mm dia. working pressure shall be 18 kg/sq.The pipe shall be coupled with SS/GM self closing shut-off nozzle of 5mm outlet. |
| 71 | Supply & installation of MS panel with glass front for shaft covarage fabricated from 16 SWG CRCA sheet with lockable arrangements to accmmodate 2 RRL hose of 15m lenth and one branch pipe painted white inside and red outside with one key . |
| 72 | Supplying, fitting & fixing Partially insulated fire resistant door frame of 120 minutes fire rating (FD 120 PI - 120 min integrity , 30 min insulation) conforming to IS:3614-2021 (Amendment no -1, July,2023) tested in accordance with the procedures laid down in IS 17518 (Part-I), of section 140 x 65 mm having built in rebate made out of 1.6 mm (16 gauge) G.I. sheet (zinc coating not less than 120 gm/sqm. total on both sides conforming to IS 513 part-1 & 2 or IS: 277) finished with suitable powder coating duly filled with vermiculite based concrete mix/proprietary material, suitable for mounting 120 minutes fire rated door shutters (FD 120 Pl). The frame is fitted with intumescent fire seal strip and EPDM smoke seal all-round the frame as standard component of door assembly and 3 mm thick support plate to provided to receive hardware and ironmongery. Rate should include supply and installation complete as per direction of Engineer-in-charge (Door frame should be compatible to fix hardware but excluding cost of hardwares like hinges, door closer, Bolt, lock etc.).Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplied door are to be submitted by manufacturer.Ground Floor |
| 73 | 1st Floor |
| 74 | 2nd Floor |
| 75 | 3rd Floor |
| 76 | 4th Floor |
| 77 | 5th Floor |
| 78 | 6th Floor |
| 79 | 7th Floor |
| 80 | Supplying, fitting & fixing Partially insulated fire resistant door leaf of 50mm thick fully flush double skin door shutters (with vision lite not exceeding 0.06 sqm.) of 120 minutes fire rating (FD 120 PI - 120 min integrity , 30 min insulation) conforming to IS:3614 -2021 (Amendment no -1, July,2023) tested in accordance with the procedures laid down in IS 17518 (Part-I), tested with suitable mounting on door frame, made out of 1.2 mm (18 gauge) G.I. sheet (zinc coating not less than 120 gm/sqm. total of both sides conforming to IS 513 part-1 & 2 or IS: 277) finished with suitable powder coating duly filled heat-resistant mineral wool/Ceramic wool/proprietary material satisfies the requirement of fire door ratings and fixing with necessary stainless steel ball bearing hinges of approved make. Vision lite should be provided with a bedding and screw from inside. The glass in vision lite should be clear fire rated of relevant rating. Shutter shall have pre-drilled support plates with hinge guard covers, concealed lock/latch box with lock fitting brackets and pre-tapped holes. Rate should include supply and installation complete as per direction of Engineer-in-charge. (Door shutters should be compatible to fix all hardwares but excluding cost of all hardwares like hinges, vision panel, bolt, door closer, door lock, panic bar, handle etc.)Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years} of same door configuration of area equal or more than supplied door are to be submitted by manufacturer. The label shall be affixed on door leaf containing information as- i) Name of manufacturer ii) Type of fire door iii) Fire rating classification iv) Serial no of door v) Year of manufacture and vi) Certificate reference number.Single leaf - upto 1250 mm width.Double leaf- exceeding 1250 mm width with intumescent fire seal strip on meeting style and astragals has to be provided on meeting style for both active and inactive leaf.Ground Floor |
| 81 | 1st Floor |
| 82 | 2nd Floor |
| 83 | 3rd Floor |
| 84 | 4th Floor |
| 85 | 5th Floor |
| 86 | 6th Floor |
| 87 | 7th Floor |
| 88 | Supplying, fitting & fixing 120 minutes Fire rated Clear Vision Pane (Size 200 mm width x 300 lllm height) should be provided with a bedding and screw from inside. Rate should include supply and installation complete as per direction of Engineer-in-charge.Individual or Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplied door are to be submitted by manufacturer. |
| 89 | Supplying, fitting & fixing 120 minutes Fire rated Concealed Flush Bolt (For DBL Leaf) of approved quality fitted and fixed with Stainless steel screws. Rate should include supply and installation complete as Per direction of Engineer-in-charge.Individual or Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplied door are to be submitted by manufacturer. |
| 90 | Supplying, fitting & fixing 120 minutes Fire rated Dead Lock of approved quality fitted and fixed complete. Rate should include supply and installation complete as per direction of Engineer-in-charge.Individual or Complete representative door assembly test certificate of CBRI or NABL approved laboratory (not older than 5 years) of same door configuration of area equal or more than supplieddoor are to be submitted by manufacturer. |
| 91 | Supplying, fitting & fixing fire rated Stainless Steel ball bearing hinges with Grade SS 304 of approved quality fitted and fixed with Stainless steel screws. Rate should include supply and installation complete as per direction of Engineer-in-charge.Size: 100mm. X 75mm. X 3.0 mm thick. |
| 92 | Sealing of Electrical Shaft, ELV, Plumbing, Fire duct floor opening by supply & application of 50 mm thick FISCHER Fire Stop Mortar or equivalent specially formulated gypsum based compound (Consumption @ 40 kg/Sqm dry weight) over Mineral Wool backing surface which when mixed with water can be trowelled or poured around service penetrations in either vertical or horizontal applications. Tested to BS 476-20, IS 12458 standard, NBC2016 FFSC can provide 2 hours integrity and insulation. it has been design to set within 30-45 Min depending on ambient temperature, and is capable of accommodating foot traffic within 72 hours. Formulated to be halogen and asbestos free the FFSC exhibits excellent load bearing capacity and can be help to maintain the sound reduction index of a structure. All peripherial contact of pipes, cables, HVAC ducts shall be sealed with a joint filler FiAM intumescent sealant (For metal pipes, upto 25 mm PVC pipes, Cables)/ (FiGM/UFS310) intumescent sealant (For insulated HVAC Duct)/FiPWE2 intumescent graphite based synthetic wrap strip (For above 50 mm dia PVC pipes) (Cost of sealent & pipe wrap to be paid seperately). To be installed in accordance with the detailed instructions or the approved system at all level & floor inclusive of all materials, labour, tool & tackles, and backing arrangements etc all complete as per direction of Enginer-in-Charge. (Load Bearing Solution for floor upto 200 Kg/opening)Backing materials details are as follows-8mm Dia ISI TMT Bar (spacing @ 200mm c/c) with Anti Corrosive Paint (Red oxide) (including charges of drilling, fixing in position, painting, grouting but excluding cost of renforcing bar), Consumption of reinforcement - 5.3 kg/Sqm.GI Welded wire net of 30 sqmm Mesh should placed over Rebar structure.Mineral Wool of 64 Kg/cum density, 50 mm thick to be placed over GI welded wire net. |
| 93 | Supply & Application of FISCHER FiAM or equivalent Intumescent Firestop Sealant around metallic Services periphery of MS Pipes / GI duct / PVC Conduit upto 25mm passing through floor to provide up to 2 hours insulation and integrity in accordance to UL EU, IS 12458 standard. Application thickness 6 mm with annular space 15mm. PVC Conduit upto 25mm dia / GI Duct / Metallic Pipe upto 250mm - As per UL EU Standard.To be applied in accordance with the detailed instructions or the approved system at all level & floor inclusive of all materials, labour, tool & tackles, and backing arrangements etc all complete as per direction of Enginer-in-Charge. |
| 94 | Supply and application of Fire Barrier Joint SEALANT system UFS310 / FiGM or equivalent around Insulated HVAC Duct with minimum 2 hours fire rating when tested in accordance with ASTM E 1966 standards / UL - EU for fire in floor & wall openings made of concrete / Block work / Dry wall. The Joint sealant shall be a flexible material to accomadate the movement upto 15%.The sealant to be applied at 16mm thickness as per the recommendation of manufacturer. The cost shall include support system or other miscellaneous items etc. To be applied in accordance with the detailed instructions or the approved system at all level & floor inclusive of all materials, labour, tool & tackles, and backing arrangements etc all complete as per direction of Enginer-in-Charge. |
| 95 | Sealing of Wall Penetration (Medium & Large cutout) by Supply and installation of Fire resistant Mineral Wool Board system painted with Fischer RFS640 or equivalent with minimum 2 hours fire rating when tested in accordance with UL 1479, IS 12458 standards, for fire rated horizontal openings in walls made of concrete, masonry, fire rated gypsum partition, after passing service lines like Cable,Cable trays, Bus Duct or Metal pipes, PVC pipes, insulated HVAC Duct etc. The fire resistant board system shall comprise of a mineral wool board coated with an ablative coating of 3.2mm wet flim thickness on both sides (Consumption of paint @ 7.1 Litre/Sqm. for both sides). The mineral wool board shall be of min.140 kg/m3 density. All peripherial contact of pipes, cables, HVAC ducts shall be sealed with a joint filler FiAM intumescent sealant (For metal pipes, upto 25 mm PVC pipes, Cables)/ (FiGM/UFS310) intumescent sealant (For insulated HVAC Duct)/FiPWE2 intumescent graphite based synthetic wrap strip (For above 50 mm dia PVC pipes) (Cost of sealent & pipe wrap to be paid seperately). To be installed in accordance with the detailed instructions or the approved system at all level & floor inclusive of all materials, labour, tool & tackles, and backing arrangements etc all complete excluding cost of joint filler FiAM/(FiGM/UFS310)/FiPWE2 intumescent sealant as per direction of Enginer-in-Charge. |
| 96 | Supplying, fitting & fixing of Fire Escape Route Floor plan of size 450x600 mm as per design drawing approved by the Engineer-in- charge made of the Photoluminuscent vinyl sheetpasted on 4mm thick ACP Sheet coverdand with 4mm thick toughened glass to be fixed on wall with necassary studs complite in all respect. |
| 97 | Supplying, fitting & fixing of Signage for Fire Escape and other symbols of size 300x150mm or any size approved by the Engineer-in-Charge as per relevant I.S. Code 9457-2005/I,S Code 12349-1988/I.S.Code13716 complete in all respect. |
| 98 | Supply and fitting in position the signages “FIRE ORDER” contain following matter on 3 mm thick Opaque PVC foam board of computerised cut. PVC non-reflective self adhesive vinyle painted foam board of size 1200x1000mm.ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION. EVACUATE THE OCCUPANTS BY USING FIRE EXIT AND ASSEMBLE AT ASSEMBLE POINTS. BE CALM AND DO NOT GETPANIC ,WALK DO NOT RUN IF POSSIBLE TRY TO EXTINGUISH FIRE BY USING NEAREST/ SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. |
| 99 | Inspection of entire hydrant network at least once in a month and submit report to PWD for any leakage or damage of hydrant / landing valves or any other type of valves and instruments (water pipe lines etc.) for taking further course of action to ensure proper functionality of the installed fire protection system.i) Whole Fire Hydrant and Sprinkler System.---1 Job. Please Enable Macros to View BoQ information |