| 1 | Labour for Chipping of concrete surface before taking up Plastering work.(for laying tiles)In ground floor including roof.Upto 150 mm thick |
| 2 | Dismantling artificial stone flooring upto 50 mm.thick by carefully chiselling without damaging the base and removing rubbish as directed within alead of 75 m.a) In ground floor including roof. |
| 3 | 1st floor |
| 4 | 2nd floor |
| 5 | 3rd floor |
| 6 | Stripping off worn out plaster and raking outjoints of walls, celings etc. upto any height and in any floor including removing rubbish within alead of 75m as directed. |
| 7 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof. |
| 8 | 2nd floor |
| 9 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separatelyUpto area 2.5 Sq.m |
| 10 | Taking out door and window shutters and rehanging the same with old fittings With new iron screws. |
| 11 | SE approved rate Applying 2 coats of Acrylic Polymer Modified Paint(Equivalent to MASTER CRETE M81 of choksey or similar specified product) having bonding properties for specific use of bonding between old concrete and new concrete or disimilar cementiciaous material by mixing in proportion (1 liquid : 1 cement) as per manufacture's specification. |
| 12 | SE approved rate Applying 2 coats of component of 2 coats component Non-Toxic Epoxy Resin Based Paint (Equivalent to TECHOXY-3 of Choksey or similar spefic product) having waterproofing properties and also can be applied in specific case of damp condition on concrete or plastered surface by mixing in proportion by weight 1 part 1 :1 Part 2:1 part water) or as per manufacture's specification for water proofing layer in water tank etc. |
| 13 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.Tor steel/Mild Steelground floor |
| 14 | 1st floor |
| 15 | 2nd floor |
| 16 | Welding in M.S. structural work with gas or electric. Tack weld |
| 17 | Supplying. preparing and placement of ready mix non shrink cementious microconcrete having no metalic aggregate or chlorides for repairing and \iackting of damaged R.C.C.members. |
| 18 | Supplying and application of chemicalfor rebar anchoring by using ETA approved/Or seismic criteriain rebarconnection, Including drilling hole to the required depth by rotary hammer drill,cleaning with brush& jet of clean air, IPlllng resin and hardener using serrated nozzle to eliminate mixing error and In a voldlessmanner Includingchargesfor all tools & plants. Applicationto be \\"0: designedfor rebars as per ECZ/TR023or relevant tested and accepted design IS guidelinesand the design document to be furnished by the manufacturer.The chemicalshould have ETAapprovalfor seismic criteriaof rebarfixing which should be furnished by manu/Octurer. The installation and the setting instructionsshould be strictly followed as per manufacturer'sspecificationsas approved by EICprior to drilling. The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement in |
| 19 | Guniting concrete surface with cement mortar (25 mm nominal thick) applied with compressor after cleaning surface and spraying with epoxy complete as per Technical specification. |
| 20 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy. |
| 21 | Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1. |
| 22 | Applying epoxy mortar ( 10 mm nominal thick) over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical specification |
| 23 | Wood work in door and window frame fitted and fixed in position completeincluding a protective coat of painting at the contact surface of the frameexluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum shouldbe correted upto three decimals). |
| 24 | 1st floor |
| 25 | 2nd floor |
| 26 | 3rd floor |
| 27 | 4th floor |
| 28 | Cutting holes and subsequent mending gooddamages.a) Diameter upto 150 mm. In brick work [Cement-4.0 Kg/Mtr] for fixing grill |
| 29 | M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25%for each addl. floor above 4th floor)Grill weighing above 16 Kg./sq.mtr and above (1sr floor) |
| 30 | 2nd floor |
| 31 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes. Pakur Variety (ground floor) |
| 32 | 1st floor |
| 33 | 2nd floor |
| 34 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominalsize) excluding shuttering and reinforcement,if any, in gound floor as perrelevant IS codes.Pakur variety (ground floor) |
| 35 | 1st floor |
| 36 | 2nd floor |
| 37 | 3rd floor |
| 38 | Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts)[Non-modular sizes for tiles with Water Absorption (av.) ≤0.08 %] in floor, skirting etc. set in 20 mm thick sand cementmortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thickcement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm ofWhite cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tileswith warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction ofEngineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5mm thick) |
| 39 | 2nd floor |
| 40 | 3rd floor |
| 41 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007and testing shall be made in accordance with IS:13630 [Non- modular sizes fortiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance:Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area ofbuilding e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. setin 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side oftiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqmbelow mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make asdirected and removal of wax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finish complete includingthe cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be supplied by the contractor) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength >1500 N |
| 42 | 1st floor |
| 43 | 2nd floor |
| 44 | 3rd floor |
| 45 | Supplying,fitting & fixing granite slab 15mm to 18mm thick infloor, lobby, stair, landing and treads etc. over 20mm (avg)thick base of cement morter (1:2) laid with white cement slurry@ 4.40Kg per Square meter before placing of granite andjointed with white cement slurry @ 2.0 Kg per square meterwith necessary pigments and complete as per direction ofEngineer-in-charge including cost of all materials, abours,curing and roughening of concrete surface complete.In ground floorb) Area of each Granite slab 0.6 to 1.0 Square meter. Source of granite : available outside of west bengal physical properties of granite shall comferm to is 14223 (part - 1):2023 |
| 46 | 1st floor |
| 47 | 2nd floor |
| 48 | 3rd floor |
| 49 | Supplying, fitting & fixing granite tiles 10mm to 12mm. thickin columns, wall, facia etc. with polymerised adhesive and epoxy grout pointing including making suitable arrangements to hold thestones properly by brass / copper hooks including pointing in cement ortar (1:2) (1 white cement : 2 marble dust) withadmixture of pigment matching the stone shades all completeas per direction of the Engineer-in-charge including cost of allmaterials, labours, scaffolding, staging ,curing androughening of concrete surface complete. [Using cement slurry at back side of tiles@ 4.4 kg/sq.m &white cement slurry for joint filling @ 1.8 kg/sq.m]Area of each Granite slab 0.6 to 1.0 Square meter. Source of granite : available outside of west bengal physical properties of granite shall comferm to is 14223 (part - 1):2023. Area of each granite slab upto 0.2 sqm |
| 50 | 1st floor |
| 51 | 2nd floor |
| 52 | 3rd floor |
| 53 | Cutting joints of existing floor and wall (Granite /Marble / Tiles etc. by 3 mm wide and 7 mm deep asnd filling the joints with 100 % stain free, chemical and temperature resistant, anti- bacterial and anti fungal epoxy grout with approved manufacturer to match etc. |
| 54 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortarincluding rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement 20 mm thick plaster (1st floor) |
| 55 | 2nd floor |
| 56 | 3rd floor |
| 57 | With 1:4 cement 10 mm thick plaster (1st floor) |
| 58 | 2nd floor |
| 59 | Reconstructing brick chulla with ½ old and ½ new 1st class bricks in limemortar (1:2) and 20mm thick (1:2) surki beaten plaster and renewal ofgrating and cheeks (overall measurement notless than 0.5 cu m) |
| 60 | Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory madesolid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S.frame shall have cost of steel primers of approved make and manufacture, M.S.frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70mm width out of which 50 mm shall be flat and 20 mm shall be apered in 45degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheetout of which 75 mm shall be flat and 20 mm tapered in 45 degree on the innerside to form top & bottom rail and 115 mm wide PVC sheet out of which 75mmshall be flat and 20 mm shall be tapered on both sides to form lock rail. Top,bottom and lock rails shall be provided either side of the panel with 10 mm (5mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom railsheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined togetherwith solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which isto be stuck on the interior side of the “C” channel using PVC solvent adhesiveetc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge.ground floor |
| 61 | 1st floor |
| 62 | 2nd floor |
| 63 | Removing old scales, blisters etc. of interior surface of walls,ceiling byscraping etc. and preparing smooth and even surface with rendering orcement mortar (1:2) (as necessary), to make the surface suitable forreceiving distemper. (Payment against this item will be made only whenthis has been done on the specific direction of the Engineer-in-charge). |
| 64 | Rendering the surface of walls and ceiling with white cement basedwall putty of approved make and brand(1.5mm thick) |
| 65 | Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer's specification andas per direction of the EIC. In Ground Floor One CoatWater based interior grade Acrylic Primer |
| 66 | Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) :(Two coats) Luxury Quality |
| 67 | Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 68 | Priming one coat on timber or plastered surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 69 | Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc. includingusing of approved putty etc. on the surface, if necessary : On timber or plastered surface with super hi gloss :Two coats (with any shade except white) |
| 70 | On steel or other metal surface :Two coats (white in shade) |
| 71 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. |
| 72 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark.100mm. X 50mm. X 1.25mm. |
| 73 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flatbent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) asper direction. (Cost of concrete will be paid separately)40mm X 6mm, 125mm Length |
| 74 | Anodised aluminium barrel / tower / socket bolt (full covered) of approvedmanufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:150mm long x 10mm dia. bolt. |
| 75 | Anodised aliminium D-type handle of approved quality manufactured fromextruded section conforming to I.S. specification (I.S. 230/72) fitted and fixedcomplete:150 mm grip x 10 mm dia rod. |
| 76 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. |
| 77 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized(with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding &casement windows, partitions, formed of basic sections of any ISIembossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work). In 10-12 Micron thickness Annodizing filmI)Natural white2- track sliding window COLOUREDBottom frame |
| 78 | top & side frame |
| 79 | Shutter for all track sliding window.Bottom & top |
| 80 | Style side member |
| 81 | Interlock member |
| 82 | Fixed partitions.(Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.)Top, Bottom, Side |
| 83 | Intermediate member |
| 84 | glazing clip |
| 85 | Louverded Windowtop & bottom side |
| 86 | Louverded section |
| 87 | Cleat angle |
| 88 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.For sliding windows T' shaped EPDM gasket for frames. |
| 89 | U' shaped EPDM gasket for frames. |
| 90 | Supplying PVC rollers for sliding windows as per direction of Engineerin charge. |
| 91 | Supplying maruti lock (100mm) |
| 92 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.4mm thick coloured / tinted / smoke glass. |
| 93 | Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminium sections for the following units:-Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shapeand size, drilling and aligning of window shutter frame fitted with in builtlocking arrangements, sliding rollers and other necessary fittings, fixture,adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column,beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass asper drawing, specification and direction of EIC.The rate includes the hire charge of all tools and plants, including acidental charges, adhesive, joineries such as screw, cleat angle etc. butexcluding the cost of extruded aluminium sections, glass, neoprene /EPDM gasket, locking arrangement and rollers.2 track sliding window.1st floor |
| 94 | 2nd floor |
| 95 | Louvered window |
| 96 | Grinding to marble / mosaic floor including remaining stone,if necessary, after cutting with manual labour / machine,where necessary |
| 97 | S & P works Cleaning glazed tiles with acid. |
| 98 | Dismantling Orissa pattern W.C. including taking out of base concrete, ifnecessary, complete. |
| 99 | Dismantling urinal. |
| 100 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreouschina ware of approved make complete in position with necessary bolts,nuts etc.With 'P' trap (with vent) |
| 101 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in whitevitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete.470 mm X 280 mm X 340 mm |
| 102 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make withnecessary fixing materials and clamps complete. Polythene Flush Pipe |
| 103 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming toI.S. specification with P.V.C. fittings complete,C.I. brackets including twocoats of painting to bracket etc. |
| 104 | supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.Anglo Indian Plastic (hallow type) white |
| 105 | Supplying, fitting & fixing Centrifugally Cast (spun) iron soil,waste waterand rain water (Hubless) pipe epoxy coated inside & outside conformingto I.S. 15905 / 2011 with bobbins, nails etc. including making holes in thewall, floor etc. and cutting trenches etc. in any floor through masonryconcrete, if necessary, and mending good damages with necessary jointingmaterials and painting two coats to the exposed surface with approvedpaint complete. (Measurement will be made along the center line of thetotal pipe line in fitted condition including specials,payment for specials &Painting will however be paid seperately).100 mm internal |
| 106 | Supplying, fitting & fixing Centrifugally Cast (spun) iron (Hubless) double branch equal without door conforming to I.S. 15905 / 2011 including alljoining materials but excluding coupling. 100mm dia |
| 107 | Supplying,fitting and fixing Centrifugally Cast (spun) iron (Hubless)composite 88 degree 'T -Y' single branch conforming to I.S. 15905 / 2011including all joining materials but excluding coupling. (Coupling to bepaid seperately). 100mm |
| 108 | Supplying, fitting & fixing Centrifugally Cast (spun) iron (Hubless) bendwith door conforming to I.S. 15905 / 2011 including all joining materialsbut excluding coupling. 100mm |
| 109 | Supplying, fitting & fixing Centrifugally Cast (spun) iron vent cowlconforming to I.S. 15905 / 2011 including all joining materials butexcluding coupling. 100mm |
| 110 | Dismantling wash basin with brackets with or without waste fittings. |
| 111 | Wash basin vitreous china of approved make (without fittings)supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.550 mm X 400 mm size |
| 112 | Supplying, fitting and fixing Waste fittings complete.C.P. over brass 32mm |
| 113 | Supplying, fitting and fixing pillar cock of approved make.PTMT Pillar Cock - 15 mm. (Prayag or equivalent). |
| 114 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR whiteflexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.450 mm long |
| 115 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps.900 mm long |
| 116 | Supplying, fitting and fixing bib cock or stop cock.e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent)15 mm |
| 117 | Supplying, fitting and fixing alloy iron with brass spindle bib cock/stop cock of approved brand and make, spray painted and tested to 21 kgper sq. cm. stop cock 15mm |
| 118 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessaryaccessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc. fitted withholder bats clamps, including cutting pipes, making threads, fitting, fixingetc. complete in all respect including cost of all necessary fittings asrequired,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separatepayment will be made for accesories, specials. Payment for painting willbe made seperately) For Exposed Work 15 mm dia. medium light quality |
| 119 | Sub Total |
| 120 | GST @ 18% |
| 121 | Cess @ 1% Please Enable Macros to View BoQ information |