| 1 | Distribution wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/RR Kabel/Havells/Polycab/Gloster) in 19 mm bore, 3 mm thick polythene pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of ROMA Urban as approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC |
| 2 | (i) Average run 9 mtr |
| 3 | Distribution wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/RR Kabel/Havells/Polycab/Gloster) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Legrand: Myrius/Arterior or equivalent model of ROMA Urban as approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC |
| 4 | (i) On Board |
| 5 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 6 | 12 module |
| 7 | 6 module |
| 8 | Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required. |
| 9 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 10 | Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 11 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 12 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 13 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket [Make-(Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 14 | Fixing of cabin/wall bracket fan on wall/ceiling, S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length with wooden base on wall and complete with all fixing accessories incl. interconnection as per direction by EIC |
| 15 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter |
| 16 | 23 cm (9\\") |
| 17 | Fixing only Ceiling light fittings on wall /ceiling by screws etc. |
| 18 | Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required. |
| 19 | Supplying & Fixing 240 V AC/DC superior type Multitune (min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board incl. S&F HW board |
| 20 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.. |
| 21 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (L&T/Anchor) & necy. connections |
| 22 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket [Make-(Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C], without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 23 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/RR Kabel / Havells / Polycab/Gloster) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. |
| 24 | i) 3 x 22/0.3 (1.5 sqmm) |
| 25 | ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) as ECC |
| 26 | iii) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
| 27 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 28 | a) 20 mm size |
| 29 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 30 | a)1.5 sq mm |
| 31 | b) 2.5 sq mm |
| 32 | c) 4 sqmm |
| 33 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 34 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 35 | Fixing only lamp |
| 36 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/Ceiling. |
| 37 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD with powder-coated pressure Die-cast Aluminium with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy ≥ 110 lm/Watt (Make:- Signify/Crompton/Wipro) |
| 38 | 12 - 15 Watt |
| 39 | Supplying and delivery of LED Industrial Batten light made of CRCASheet Body (Thickness ≥ 0.50 mm) and construction as per relevantIS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt (Make: Signify / Crompton / Wipro) |
| 40 | Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification |
| 41 | Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 140 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient/ USHA ) |
| 42 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient/ USHA ) |
| 43 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient/ USHA ) |
| 44 | Supply & delivery of 11W LED mirror light with aluminium die cast and poly carbonate diffuser, having Colour temparature (CCT) -4000K , Luminous efficiency - 110 lumen/watt (Make- Philips ( Signify) 31165 or equivalent model of Wipro as approved by E.I.C) |
| 45 | Supply & Delivery of 9 watt LED bulb (Make-Philips Eye pro/wipro eq) |
| 46 | Supply, Delivery & Installation of 10 ltr (4/5 star rated) Geyser (Make: Venus Lyra 10R/ AO Smith SAS 10 / VGuard Pebble Shine Plus ) |
| 47 | Disconnection & dismantling existing old Electrical installation, Switchboard, wiring, Electrical fitting/fixtures etc with owns tools & takles incl. mending good damages and clearing/removing from the site & handed over to the authority or as directed by EIC. |
| 48 | Add 18% GST |
| 49 | Add 1% LWC Please Enable Macros to View BoQ information |