| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In all kind of soil upto 1.5m depth |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In all kind of soil upto 1.5m to 3.0m. depth |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In all kind of soil upto 3.0m to 4.5m. depth |
| 4 | Providing and laying in position cement concrete of specified grade -All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).(Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)(Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (FOR COLUMN ) |
| 7 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 8 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 9 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.(Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 10 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 11 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 12 | Providing & fixing 75mm dia vent pipes. |
| 13 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 14 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 15 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -2.5- Circular shape 450mm internal diameter |
| 16 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks class-150 |
| 17 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 18 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors.(Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 20 | 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) |
| 21 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (FOR RAFT/ FOOTING)(Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 22 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floorWith Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 23 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete. All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum. All works upto plinth level. (Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 24 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete. All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum. All works above plinth level upto floor V level(Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) (Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)(Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 28 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 30 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:-30mm thick including ISI marked Stainless Steel butt hinges with necessary screws.(Kit-Ply, Green Ply, Century or As per Direction of The Engineer-in-Charge.) |
| 31 | Extra for cuttting rebate in flush door shutters (Total area of the shutter to be measured.)(Kit-Ply, Green Ply, Century or As per Direction of The Engineer-in-Charge.) |
| 32 | Providing and fixing ISI marked 35 mm flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters with one side decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick (Kit-Ply, Green Ply, Century or As per Direction of The Engineer-in-Charge.) |
| 33 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 34 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood |
| 35 | Mild steel or iron work of small sizes and sections such and holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Fabrication of hold fast for door chaukhats and windows. |
| 36 | Mild steel or iron work of small sizes and sections such and holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Fabrication of Grill and Staircase Railling. |
| 37 | Providing and fixing fly and Mosquito proof stainless steel grade 304 wire mesh gaugewith 0.5 mm dia wire and 1.4 mm wire aperture |
| 38 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia |
| 39 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (Tata, JSW, SAIL, Jindal or As per Direction of The Engineer-in-Charge) |
| 40 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) (Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 41 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20mm square bar |
| 42 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. |
| 43 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia |
| 44 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 45 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit) with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 46 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of : 100 mm dia |
| 47 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp. |
| 48 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm dia. |
| 49 | Supply of submersible pump of make KSB 2.0 HP with control panel, support wire etc. complete. |
| 50 | Providing 2 core PVC insulated submersible cable from pump panel to submersible pump |
| 51 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore.(Tata, Jindal, JSW or as per Direction of The Engineer-in-Charge.) |
| 52 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) |
| 53 | Supply of 100mm dia Johnson screen. |
| 54 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 55 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 56 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 57 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 58 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 59 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 Coarse sand (Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 60 | 12 mm cement plaster in single coat on FAIR side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 Coarse sand (Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 61 | 40 mm thick Cement concrete floor with cement approved coarse sand and 2cm. Graded approved stone ballast laid in planels finished with 3mm (1/8\\") floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified over and including 8 cm. (3\\") local sand and brick ballast 4 cm. gause in proportion of 1:4:8 and removing any giving then a uniform finish,including supply of all materials, labour, T&P etc. required for proper completion of the work. But without base concrete.(Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 62 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING] (Kajaria, Somany, AGL, Orient, Nitco or As per Direction of The Engineer-in-Charge.) |
| 63 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN SKIRTING] (Kajaria, Somany, AGL, Orient, Nitco or As per Direction of The Engineer-in-Charge.) |
| 64 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. [IN FLOORING] |
| 65 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [IN SKIRTING] |
| 66 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour and shade Area of slab upto 0.50 sqm |
| 67 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete.(Kajaria, Somany, AGL, Orient, Nitco or As per Direction of The Engineer-in-Charge.) |
| 68 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.(Asian, Burger, Nerolac, Birla or as per Direction of The Engineer-in-Charge.) |
| 69 | Two coat Wax or French polishing new wood work with approved ready made wax polish or approved French polish after rubbing down with sand paper, including supply of all material, labour and tools & plants etc required for proper completion of the work. |
| 70 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.(Asian, Burger, Nerolac, Birla or as per Direction of The Engineer-in-Charge.) |
| 71 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (Asian, Burger, Nerolac, Birla or as per Direction of The Engineer-in-Charge.) |
| 72 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . |
| 73 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(Birla white, Wonder, Burger, Asian, J.K. Cement or as per Direction of The Engineer-in-Charge.) |
| 74 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes. (Birla white, Wonder, Burger, Asian, J.K. Cement or as per Direction of The Engineer-in-Charge.) |
| 75 | Providing and fixing bright /matt finished Stainless Steel sliding door bolt of approved quality & make with necessary screws etc all complete. 250x16 mm |
| 76 | Providing and fixing bright /matt finished Stainless Steel tower bolt of approved quality & make with necessary screws etc all complete. 250x10 mm |
| 77 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125mm |
| 78 | Providing and fixing stainless steel hanging floor door stopper with necessary screws etc. complete. Twin rubber stoper |
| 79 | Providing and Fixing of Door silencer including necessary screws etc complete |
| 80 | Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 81 | Chequerred precast cement concrete tiles 20 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 82 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm). (Asian, Burger, Nerolac, Birla or as per Direction of The Engineer-in-Charge.) |
| 83 | Supply and filling of cinder in sunken in portion of building including breaking into required sizes including supply of all material, labour T&P required for proper completion of the work. |
| 84 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 85 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK |
| 86 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: |
| 87 | Providing, assembling and supplying visionglass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm |
| 88 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. |
| 89 | Reinforcement cement concrete work in RCC culvert slab with 1:2:4 (1 cement : 2 coarse sand and 4 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 90 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 91 | Providing, laying, spreading and compacting stone aggregates of 22.4-53 mm sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. |
| 92 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer |
| 93 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) |
| 94 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. |
| 95 | 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) (Ultratech, Ambuja & J.K. Cement or As per direction of The Engineer-in-Charge) |
| 96 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 97 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 98 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 99 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 100 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 101 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 102 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/ Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests (Jaguar, Hindware, Parryware, Cera as per Direction of The Engineer-in-Charge.) |
| 103 | Providing and fixing white glazed earthen wate (European type) W.C. Pan 580mm dia,(10 ltr) C.I. Flushing Cistern complete with G.I. Pull chain,M.S.Bracket of Engineer-in-Charge.(Standered size) (Jaguar, Hindware, Parryware, Cera as per Direction of The Engineer-in-Charge.) |
| 104 | Providing and fixing white glazed earthen wate (European type) W.C. Pan 580mm dia,(10 ltr) C.I. Flushing Cistern complete with G.I. Pull chain,M.S.Bracket of Engineer-in-Charge.(Standered size)(Jaguar, Hindware, Parryware, Cera as per Direction of The Engineer-in-Charge.) |
| 105 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.(Jaguar, Hindware, Parryware, Cera as per Direction of The Engineer-in-Charge.) |
| 106 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia(Polycab, Supreme, Astral, AKG, Apollo or as per Direction of The Engineer-in-Charge.) |
| 107 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 108 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 109 | Providing and fixing PTMT Bottle Trap for Wash basin and sink Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms |
| 110 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 111 | Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 112 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 113 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 114 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 115 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter |
| 116 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore |
| 117 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm |
| 118 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 /90 mm dia |
| 119 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm |
| 120 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 121 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes (Polycab, Supreme, Astral, AKG, Apollo or as per Direction of The Engineer-in-Charge.) |
| 123 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (Polycab, Supreme, Astral, AKG, Apollo or as per Direction of The Engineer-in-Charge.) |
| 124 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 20 mm nominal outer dia Pipes (Polycab, Supreme, Astral, AKG, Apollo or as per Direction of The Engineer-in-Charge.) |
| 125 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 25 mm nominal outer dia Pipes (Polycab, Supreme, Astral, AKG, Apollo or as per Direction of The Engineer-in-Charge.) |
| 126 | Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore |
| 127 | Providing and fixing brass stop cock of approved quality. 20 mm nominal bore |
| 128 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or as per Direction of The Engineer-in-Charge.]. |
| 129 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. Double socketed pipes. 110mm dia P.V.C. pipe(Polycab, Supreme, Astral, AKG, Apollo or as per Direction of The Engineer-in-Charge.) |
| 130 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. Double socketed pipes. 90mm dia P.V.C. pipe(Polycab, Supreme, Astral, AKG, Apollo or as per Direction of The Engineer-in-Charge.) |
| 131 | Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. P-Trap type Floor Trap 110 x 90 mm (Polycab, Supreme, Astral, AKG, Apollo or as per Direction of The Engineer-in-Charge.) |
| 132 | Providing and fixing terminal guard. a) 110mm |
| 133 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 110mm bend |
| 134 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 90 mm bend |
| 135 | Coupler 110mm |
| 136 | Coupler 90mm |
| 137 | Single tee with door 90x90x90 mm |
| 138 | Single tee with door 110x110x110 mm |
| 139 | Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore |
| 140 | Providing and fixing clean out plug 110 mm dia. |
| 141 | S/F of upvc SWR Pipe Type -B confirming to IS -13592 incluiding jointing the pipes with rubber ring lubricant and UPVC SWR Cuplar confirming to IS 14735 also inluiding excavation of treches cutting of walls and holes and repairing of walls , floors and refilling the trenches as before cut including cost of other fittings such as door band, T and YT including supply of all materials labour and t&p required for prper complition of the work. 160 mm. dia. |
| 142 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mm diameter |
| 143 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1.50 m to 3.00 m depth Pipes 80 mm to 300 mm diameter |
| 144 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter |
| 145 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth 1.5 to 3.00 meter |
| 146 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes |
| 147 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250 mm. dia. RCC Pipes |
| 148 | Providing and laying cement concrete 1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design.150 mm. dia. |
| 149 | Providing and laying cement concrete 1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design. 250 mm. dia. |
| 150 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class-150 (i) For Sewer Line |
| 151 | Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class-150 |
| 152 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 153 | Providing & fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work) 80mm nominal bore.(Tata, Jindal, JSW or as per Direction of The Engineer-in-Charge.) |
| 154 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 65mm nominal bore.(Tata, Jindal, JSW or as per Direction of The Engineer-in-Charge.) |
| 155 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 25mm dia nominal outer dia pipes (Tata, Jindal, JSW or as per Direction of The Engineer-in-Charge.) |
| 156 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 65mm nominal bore. |
| 157 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 25mm dia nominal bore |
| 158 | Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class-150 |
| 159 | Plantation of Permanenet trees: Providing and stacking of of Cuphea chinensis of ht. 20-30 cm full of branches and healthyfoliage in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. |
| 160 | Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. |
| 161 | Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 162 | Providing and stacking of Tectona grandis (Teak) of height 150-165 cm. in big polybags ofsize 25 cm as per direction of the officer-in-charge |
| 163 | Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm.in big poly bags of size 25 cm as per direction of the officer-in-charge.v |
| 164 | Providing, stacking and Displaying Brassia Variegated having ht. 30 cm To 45 cm, well developed with fresh and healthy foliage in 25 cm size of Earthen pot / Plastic pot and as per direction of the officer-in-charge |
| 165 | Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags ofsize 25 cm as per direction of the officer-in-charge. |
| 166 | Plantation of Shrubs in flower bed: Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge. |
| 167 | Providing and stacking of Hibiscus variegated of height 60-75 cm. with 8-10 branches andhealthy variegated foliage in cement pots of size 35 cm as per direction of the officer-incharge. |
| 168 | Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165 cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-incharge. |
| 169 | Providing and stacking of Calliandra hybrida of height 75-90 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. |
| 170 | Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. |
| 171 | Providing and Displaying of Spathiphyllum (peace lily), having 15 cm to 25 cm ht. blooming stag with fresh & healthy foliage well developed in 15 cm of Earthen pot/plastic pot as per direction of officer-in-charge. |
| 172 | Providing and Displaying Marigold jaffri orange/yellow/Russet colour well developed with fresh & healthy foliage with 40 to 50 flowers in bloom specimen plant 60 to 75 cm ht in 25 cmEarthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 173 | Half brick circular tree guard in bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete: With common burnt clay F.P.S. (non modular) bricks of class designation 5.0 |
| 174 | ELECTRICAL WORKSWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B (Light Point) |
| 175 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B (Fan Point) |
| 176 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 177 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required(Call Bell point) |
| 178 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 179 | Inverter Wiring point for Light/fan/Plug with 1.5 mm copper wire |
| 180 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 181 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 182 | Supply and fixing 3 pin, 5 Amp ceiling rose on the existing junction box including connection etc as required .(Excluding GST) |
| 183 | Supply and fixing brass batten / angle holder including connection etc as required |
| 184 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 185 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 186 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. |
| 187 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 188 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 x 10 sq.mm. + 1 x 10 sq.mm. Earth wire |
| 189 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 4 x 16 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 190 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 191 | Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole |
| 192 | Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 193 | Supply and fixing of 40 Amp. DP MCB (10KA) CAT-A |
| 194 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) CAT-A |
| 195 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 196 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 197 | S&F of 63 Amp. 415 V metal clad TP HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. CAT B |
| 198 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 4 way (4 + 12), Double door |
| 199 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 12 way Double door |
| 200 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 201 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 202 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 203 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power conFRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)18-22 Watt |
| 204 | Supply & fixing of water tight oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity / transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hr Continuous Operation, Complete in All respect. compelete in all respect (1200 system lumens, >120 Lm/W, PF>0.95, CRI >70, >300V over voltage protection, 4 KV internal Surge Protection, metal housing with 5 years warrantee) |
| 205 | LED Down lighter (SMD Type) (System lumenefficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 12 to 15 watt |
| 206 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).90 Watt |
| 207 | Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 208 | Supply and fixing hexagonal/RoundG.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm& brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
| 209 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properly etc. complete as required. |
| 210 | Supply of 300 mm Fresh Air Fan |
| 211 | Supply of 450 mm sweep Exhaust Fan |
| 212 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 213 | Supply and fixing of 10 Watt LED Bulb |
| 214 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. FOR 2 Pair |
| 215 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 216 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. FOR Telephone socket outlet |
| 217 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.TV antenna socket outlet |
| 218 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. SIZE -75mm X 75 mm X 60mm Deep |
| 219 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm X 75 mm) |
| 220 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. 16 sq. mm 4 core (FOR EACH RESIDENCE ) |
| 221 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. 400 sq. mm X 3,1/2 CORE (TRANSFORMER TO MAIN PANEL) |
| 222 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. SIZE-400 X 3,1/2 CORE |
| 223 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.SIZE 16 X4 SQ MM |
| 224 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required/I.(FOR ROAD CROSSING) AND CABLE DUCT |
| 225 | Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type.Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only. INCOMING MCCB 400 AMP-1 NO AND OUT GOING MCCB 200 AMP -1 NO ,100 AMP-2 NO AND 63 AMP -1 NO |
| 226 | SUPPLY AND FIXING OF 400 Amps ,4 pol on load Changeover switch approved make (L & T/ Havells /equiblants) on angle iron stand with fastner and making Electric connection . |
| 227 | Supplying, installation by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket steel fasteners, connecting to earthing system etc as required. |
| 228 | Supplying, installation, testing and commissioning of following capacity TPN tap off box/ plug-in box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing over head bus bar system complete with TPN disconnector FSU and HRC fuese connectionn earthing etc as requred 100 amp |
| 229 | Providing and fixing MV Danger Notice Plate of 200 mm x 150 mm made of mild steel at least 2 mm thick and vitreous enameled white on both side and with inspiratin in single red colour on front side as required. |
| 230 | Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. |
| 231 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality |
| 232 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B (Light Point) |
| 233 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B (Fan Point) |
| 234 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 235 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required(Call Bell point) |
| 236 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group B |
| 237 | Inverter Wiring point for Light/fan/Plug with 1.5 mm copper wire (Excluding GST) |
| 238 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 239 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 240 | Supply and fixing 3 pin, 5 Amp ceiling rose on the existing junction box including connection etc as required .(Excluding GST) |
| 241 | Supply and fixing brass batten / angle holder including connection etc as required |
| 242 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 243 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 244 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. |
| 245 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 246 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 2 x 10 sq.mm. + 1 x 10 sq.mm. Earth wire |
| 247 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 4 x 16 sq.mm. + 2 x 6 sq.mm. Earth wire |
| 248 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 249 | Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole |
| 250 | Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 251 | Supply and fixing of 40 Amp. DP MCB (10KA) CAT-A |
| 252 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) CAT-A |
| 253 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 254 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 255 | S&F of 63 Amp. 415 V metal clad TP HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. CAT B |
| 256 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 4 way (4 + 12), Double door |
| 257 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 8way Double door |
| 258 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 259 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 260 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 261 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power conFRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)18-22 Watt |
| 262 | Supply & fixing of water tight oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity / transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hr Continuous Operation, Complete in All respect. compelete in all respect (1200 system lumens, >120 Lm/W, PF>0.95, CRI >70, >300V over voltage protection, 4 KV internal Surge Protection, metal housing with 5 years warrantee) |
| 263 | LED Down lighter (SMD Type) (System lumenefficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 12 to 15 watt |
| 264 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).90 Watt |
| 265 | Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 266 | Supply and fixing hexagonal/RoundG.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm& brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
| 267 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properly etc. complete as required. |
| 268 | Supply of 300 mm Fresh Air Fan |
| 269 | Supply of 450 mm sweep Exhaust Fan |
| 270 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 271 | Supply and fixing of 10 Watt LED Bulb |
| 272 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. FOR 2 Pair |
| 273 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 274 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. FOR Telephone socket outlet |
| 275 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.TV antenna socket outlet |
| 276 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. SIZE -75mm X 75 mm X 60mm Deep |
| 277 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm X 75 mm) |
| 278 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. 10 sq. mm 4 core (FOR EACH RESIDENCE ) |
| 279 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. 400 sq. mm X 3,1/2 CORE (TRANSFORMER TO MAIN PANEL) |
| 280 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. SIZE-400 X 3,1/2 CORE |
| 281 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.SIZE 10 X4 SQ MM |
| 282 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required/I.(FOR ROAD CROSSING) AND CABLE DUCT |
| 283 | Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type.Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only. INCOMING MCCB 400 AMP-1 NO AND OUT GOING MCCB 200 AMP -1 NO ,100 AMP-2 NO AND 63 AMP -1 NO |
| 284 | SUPPLY AND FIXING OF 400 Amps ,4 pol on load Changeover switch approved make (L & T/ Havells /equiblants) on angle iron stand with fastner and making Electric connection . |
| 285 | Supplying, installation by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket steel fasteners, connecting to earthing system etc as required. |
| 286 | Providing and fixing MV Danger Notice Plate of 200 mm x 150 mm made of mild steel at least 2 mm thick and vitreous enameled white on both side and with inspiratin in single red colour on front side as required. |
| 287 | Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. |
| 288 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality |
| 289 | FIRE FIGHTING SYSTEM(type-4 residence) |
| 290 | SITC of M.S Black Pipe \\"C\\" Class (IS:1239/3589 Including Cutting, welding etc. & providing suitable flanges alongwith necessary fittings viz. bends, tees, reducers etc. & anti-corrosive treatment. 100 mm dia. |
| 291 | SITC of M.S Black Pipe \\"C\\" Class (IS:1239/3589 Including Cutting, welding etc. & providing suitable flanges alongwith necessary fittings viz. bends, tees, reducers etc. & anti-corrosive treatment.80 mm dia. |
| 292 | SITC of First aid Hose reel drum with 20 mm dia, 30 m long rubber pipe shut off nozzle, 25 mm dia., gate valve complete conforming to IS: 884/444. |
| 293 | SITC of Single headed Hydrant Flanged bend 63 mm dia. GM/SS oblique pattern landing valve complete with blank Cap and.(Inside the Building) |
| 294 | SITC of Single headed Hydrant Flanged bend 63 mm dia. GM/SS oblique pattern landing valve complete with blank Cap and.(Outsite the Building) |
| 295 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S. Pipe |
| 296 | SITC of RRL Hose PIPE 63 mm dia x 15 m long complete with GM/SS coupling conforming to IS: 636. |
| 297 | SITC of GM/SS Branch Pipe & Nozzle IS: 903. |
| 298 | SITC of Hose Box of 18 SWG M.S Sheet with glass fronted door to accommodate 2 nos. RRL Hose & 1 nos. GM/SS Branch Pipe with nozzel.Complete in all respect |
| 299 | SITC of cast iron Single + double flanged Non Return Valve complete with nuts, bolts and washers conforming to IS 5312.(1) 100 mm dia. |
| 300 | SITC of C.I double flanged Butterfly Valve complete with nuts, bolts & washers etc. conforming IS 780.(1) 100 mm dia. |
| 301 | Providing & fixing of pressure switch in M.S. pipeline including connection etc. as required. |
| 302 | SITC of Pressure Gauge. |
| 303 | Providing & Fixing of Cubical type floor mounted fire pump control panel febricated from 16 gauge MS Sheet duly powder coated finish of approved shadea. 40 amp 3 pole MCB 50 Hz with breaking capacity 10 kw.b. One volt meter (0-500 Volt) with selector switch.c. One set including lamp. |
| 304 | SITC of Electrical Driven Terrace Pump Confirming to IS 12469:2019 suitable for automatic operation & consisting of following 35 m. Head with 450 LPM Complete in all respect complete work as per required |
| 305 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 306 | Supply & fixing of CO2 type fire extinguisher, 4.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 307 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 308 | SITC of Over head Zincalum Water tank for Terrace Tank 10000 Ltr Capacity (5000x2) Complete in all respect (TSI Steels make) |
| 309 | Supply & fixing of Fire Bucket 4 + Stand Complete in all respect |
| 310 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 311 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. |
| 312 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 313 | Supply of shock treatment chart (under I.E. Rules) |
| 314 | Supply and laying of 2000×1000×2.5mm thickness checkered Electrical rubber matting of tested quality. |
| 315 | FIRE ALARM SYSTEMSupplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 316 | Supplying & laying 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 317 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 318 | SITC of Manual Call point Break Glass type housed in MS sheet, including connection |
| 319 | SITC of Electronic LMT Hooter, housed in MS housing suitable for wall mounting/ceiling, including making connection |
| 320 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 321 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. 16 sq. mm 4 core |
| 322 | SITC of M.S Black Pipe \\"C\\" Class (IS:1239/3589 Including Cutting, welding etc. & providing suitable flanges alongwith necessary fittings viz. bends, tees, reducers etc. & anti-corrosive treatment. 100 mm dia. |
| 323 | SITC of M.S Black Pipe \\"C\\" Class (IS:1239/3589 Including Cutting, welding etc. & providing suitable flanges alongwith necessary fittings viz. bends, tees, reducers etc. & anti-corrosive treatment. 80 mm dia. |
| 324 | SITC of First aid Hose reel drum with 20 mm dia, 30 m long rubber pipe shut off nozzle, 25 mm dia., gate valve complete conforming to IS: 884/444. |
| 325 | SITC of Single headed Hydrant Flanged bend 63 mm dia. GM/SS oblique pattern landing valve complete with blank Cap and.(Inside the Building) |
| 326 | SITC of Single headed Hydrant Flanged bend 63 mm dia. GM/SS oblique pattern landing valve complete with blank Cap and.(Outsite the Building) |
| 327 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S. Pipe |
| 328 | SITC of RRL Hose PIPE 63 mm dia x 15 m long complete with GM/SS coupling conforming to IS: 636. |
| 329 | SITC of GM/SS Branch Pipe & Nozzle IS: 903. |
| 330 | SITC of Hose Box of 18 SWG M.S Sheet with glass fronted door to accommodate 2 nos. RRL Hose & 1 nos. GM/SS Branch Pipe with nozzel.Complete in all respect |
| 331 | SITC of cast iron Single + double flanged Non Return Valve complete with nuts, bolts and washers conforming to IS 5312.(1) 100 mm dia. |
| 332 | SITC of C.I double flanged Butterfly Valve complete with nuts, bolts & washers etc. conforming IS 780.(1) 100 mm dia. |
| 333 | Providing & fixing of pressure switch in M.S. pipeline including connection etc. as required. |
| 334 | SITC of Pressure Gauge. |
| 335 | Providing & Fixing of Cubical type floor mounted fire pump control panel febricated from 16 gauge MS Sheet duly powder coated finish of approved shadea. 40 amp 3 pole MCB 50 Hz with breaking capacity 10 kw.b. One volt meter (0-500 Volt) with selector switch.c. One set including lamp. |
| 336 | SITC of Electrical Driven Terrace Pump Confirming to IS 12469:2019 suitable for automatic operation & consisting of following 35 m. Head with 450 LPM Complete in all respect complete work as per required |
| 337 | Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 338 | Supply & fixing of CO2 type fire extinguisher, 4.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 339 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 340 | SITC of Over head Zincalum Water tank for Terrace Tank 10000 Ltr Capacity (5000x2) Complete in all respect (TSI Steels make) |
| 341 | Supply & fixing of Fire Bucket 4 + Stand Complete in all respect |
| 342 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 343 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. |
| 344 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 345 | Supply of shock treatment chart (under I.E. Rules) |
| 346 | Supply and laying of 2000×1000×2.5mm thickness checkered Electrical rubber matting of tested quality. |
| 347 | FIRE ALARM SYSTEM |
| 348 | Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 349 | Supplying & laying 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 350 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 351 | SITC of Manual Call point Break Glass type housed in MS sheet, including connection |
| 352 | SITC of Electronic LMT Hooter, housed in MS housing suitable for wall mounting/ceiling, including making connection |
| 353 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 354 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. 16 sq. mm 4 core (FOR EACH RESIDENCE ) |
| 355 | External Electrification Work Supply and fixing of 8 mtr. G.I. Octagonal pole of approved make (top dia 70 mm, Bottom dia 135 mm & Base plate 16 mm thick) having 3 mm, thickness with single arm bracket length of 1 mtr. length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T & P complete in all respect. |
| 356 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughend glass/ UV stabilized PC Cover and lenses suitable for 75 Watt. to 90 Watt and Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect including lABOUR 9000-10800 system lumens, High Power LED with lenses, 120 Lm/W, PF>0.95, THD <10% at full load, CRI >70,, Potted driver Set in Metal housing (Not Circuitory) Phase to phase Protection at 440V & >300V auto cut and re-start feature, with warrantee 5 years,CAT-AAA |
| 357 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. CABLE SIZE-6 SQ MM X 2 CORE |
| 358 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. CABLE SIZE-16 SQ MM X 3 ,1/2 core for main panel to feeder panel |
| 359 | Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 OUT PUT SUITABLE FOR THREE PHASE SUPPLY |
| 360 | S/F of DP MCB (6-32) AMP complete in all respect. CAT-A |
| 361 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 362 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required. |
| 363 | Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing as required. |
| 364 | S/W of 2C × 2.5Sq mm Cu conductor filexible wire in existing pole complete in all respect. |
| 365 | S/F of 40 Amp 4 way heavy duty cadmium plated copper conector with end plate complete in all respects. |
| 366 | BOQ LIFTLIFT FOR 8 PASSANGER(5 STOP + 5 RUN ) |
| 367 | Supplying, Installation, Testing & Commissioning of following capacity 8 NO passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:-(i) Speed-1 MPS(ii) Floors-5 (G+4)(iii) Travel -17 Meters (approx.)(iv) Stops & opening- 5 stops and 5 openings(v) Controller: A.C. variable voltage & variable frequency(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required.vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.(xi) Type of doors(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish).(b) Landing doors: stainless steel scratch proof .(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.(xiii)Voice announcement system in the car tomaintenance free batteries as required.(vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.(x) The car flooring should be strong to take the rated load without any deformation or damage and antiskid as approved by engineer-in-charge.(xi) Type of doors:-(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish).(b) Landing doors: stainless steel scratch proof .(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.(xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.(xv) In case of failure of ARD or other electronic |
| 368 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. CABLE SIZE-16 SQ MM X 3 ,1/2 core for main panel to feeder panel |
| 369 | S/F of DP MCB (6-32) AMP complete in all respect. CAT-A |
| 370 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. |
| 371 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required. |
| 372 | D.G. SETSupplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:(A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.(B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level sets as required (EXCLUDING GST) |
| 373 | (C) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thickM.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.(I) AMF Panel: |
| 374 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by enginer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor with clamps etc. 25 Sq mmx 3,1/2 core |
| 375 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 376 | Providing and fixing 25 mm X 5 mm G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 377 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. FOR SIZE-25 X 3,1/2 CORE AL CABLE Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail