| 1 | Civil Work |
| 2 | Site Clearence |
| 3 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish,lead upto 50 m and lift upto 1.5 m.All kinds of soil.(D.S.R.2023/2.28.1) |
| 4 | Layout of building and making reference pillars etc. complete with all respect as per instruction of |
| 5 | engineer-in-charge. (CMR) |
| 6 | Earth Work |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m,disposed earth to be levelled and neatly |
| 8 | dressed.All kinds of soil (D.S.R.2023/2.6.1) |
| 9 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.All kinds of soil. (D.S.R.2023/2.8.1) |
| 10 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (D.S.R.2023/2.27) |
| 11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (D.S.R.2023/2.25) |
| 12 | Concrete work |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). (D.S.R.2023/4.1.6) |
| 14 | R.C.C work |
| 15 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). (D.S.R.2023/5.1.2) |
| 16 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). (D.S.R.2023/5.2.2) |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo Mechanically Treated bars. (D.S.R.2023/5.22.6) |
| 18 | Form work |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 20 | Foundations, footings, bases of columns, etc. for mass concrete. (D.S.R.2023/5.9.1) |
| 21 | Columns, Pillars, Piers, Abutments, Posts and Struts. (D.S.R.2023/5.9.6) |
| 22 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick. (D.S.R.2023/5.9.21) |
| 23 | Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick.(D.S.R.2023/5.9.20) |
| 24 | Brick work |
| 25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand). (D.S.R.2023/6.4.2) |
| 26 | Finishing work |
| 27 | CEMENT PLASTER (IN COARSE SAND) |
| 28 | 15 mm cement plaster on rough side of single or half brick wall of mix: :1:6 (1 cement: 6 coarse sand). (D.S.R.2023/13.5.2) |
| 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (D.S.R.2023/13.80) |
| 30 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (D.S.R.2023/13.48.1) |
| 31 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 32 | 12.5 mm thick tapered edge gypsum moisture resistant board (D.S.R.2023/12.45.3) |
| 33 | Flooring |
| 34 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 35 | Glazed vitrified floor tiles polished finish Size of Tile 600x1200 mm (D.S.R.2023/11.41A.2.2) |
| 36 | Library Area |
| 37 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 38 | Size of Tile 1000x1000 mm. (D.S.R.2023/11.48.4) |
| 39 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 40 | Granite stone slab colour black, Cherry/Ruby red . Area of slab over 0.50 sqm. (D.S.R.2023/8.2.2.2) |
| 41 | Anti- Termite Treatment |
| 42 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% . (D.S.R.2023/2.34.1) |
| 43 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration(D.S.R.2023/2.35.2) |
| 44 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration(D.S.R.2023/2.35.3.1) |
| 45 | Treatment for foundation and Plinth level using chemical emulsion @5 liters per Sq.M. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration ( CMR ) |
| 46 | Door/Window |
| 47 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 48 | Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R3 series with frame (55 mm & above)x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre). (D.S.R.2023/9.147.F1.1) |
| 49 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 50 | Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles.Using R3 series with frame (55 mm & above ) x (45 mm & above) & sash (55 mm & above) x (65 mm & above). (Height upto 1.8 metre) (D.S.R.2023/9.147.E1.2) |
| 51 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows |
| 52 | 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).(D.S.R.2023/9.7.7.2) |
| 53 | Weather Silicon sealant (D.S.R.2023/8646) |
| 54 | TOILET HE/SHE |
| 55 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 56 | Glazed Vitrified tiles Matt/Antiskid finish of size 600x600 mm (D.S.R.2023/11.41A.3.1 ) |
| 57 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 58 | Size of Tile 600x600 mm (D.S.R.2023/11.47.2 ) |
| 59 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 60 | Size of Tile 600x600 mm. (D.S.R.2023/11.48.2) |
| 61 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge |
| 62 | Extruded section profile size 48x40 mm (D.S.R.2023/9.117.1) |
| 63 | Bathrrom |
| 64 | Providing and fixing to existing door frames. 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). (D.S.R.2023/9.118.1) |
| 65 | Bathroom |
| 66 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 67 | Fixed window / ventilator with mullion / transom.Using R3 series with frame (55 mm & above ) x (45 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 2.5 meter ) (D.S.R.2023/9.147.C2.3) |
| 68 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm (D.S.R.2023/17.32.4) |
| 69 | He / She Toilet |
| 70 | Sanitary Fittings: |
| 71 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (D.S.R.2023/17.78) |
| 72 | He / She Toilet |
| 73 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (D.S.R.2023/17.80) |
| 74 | He Toilet |
| 75 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. (D.S.R.2023/17.7A) |
| 76 | He / She Toilet |
| 77 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 . 15mm nominal bore (D.S.R.2023/18.53.1) |
| 78 | Basin |
| 79 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore. (D.S.R.2023/18.51.1) |
| 80 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.(D.S.R.2023/17.22) |
| 81 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.(D.S.R.2023/17.22A) |
| 82 | Basin |
| 83 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(D.S.R.2023/18.48) |
| 84 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore.(D.S.R.2023/18.18.3) |
| 85 | Water supply & Drainage |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 87 | 25 mm nominal dia Pipes (D.S.R.2023/18.8.3) |
| 88 | He / She Toilet |
| 89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 90 | 40 mm nominal dia Pipes (D.S.R.2023/18.9.5) |
| 91 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 92 | 110 mm diameter (D.S.R.2023/12.41.2) |
| 93 | OTHER ITEMS: |
| 94 | Add for Fire Fighting Down Comer System ( CPWD / PAR 2023 / 1.5.1) |
| 95 | Complete Built up Area |
| 96 | Supplying, Installation, testing and commissioning of LAN system comprising of core switches &L2 switches with 10 G, 10 giga SFP modules, Wifi access points, WIFI controller, network management software, Racks, CAT 6A cable, patch panels, OFC etc. (CPWD / PAR 2023 / 6.16.1) |
| 97 | Supplying, installation, testing and commissioning of IP based CCTV system for building security comprising of PTZ/ fixed camera, cabling, recording, display system and hardware software support - for indoor purpose only. (CPWD / PAR 2023 / 6.10.1) |
| 98 | Furniture Total As per Annexure - A ( Total 129 Items ) , Make - Geeken |
| 99 | Computers as per specs attached in Annexure B |
| 100 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 101 | Center Skylight |
| 102 | (D.S.R.2023/25.8) |
| 103 | Air Conditioning System |
| 104 | ( details as per Annexure -I attached ) |
| 105 | Total of 2 Pc 4.0 TR Cassette Ac and 1 Pc 1.0 TR Hiwall Split Ac , Complete with accessories & installtion |
| 106 | DEVELOPMENT OF SITE |
| 107 | Horticulture operations including 300mm earth filling , grassing , tree plantations, shrubs and potted plants etc. (CPWD PAR 2023/5.9.1) |
| 108 | Rain water harvesting (RWH) (CPWD PAR 2023/5.6) |
| 109 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. .(D.S.R.2023/16.68) |
| 110 | External Sewerage(CPWD PAR 2023/5.3) |
| 111 | Boundary Wall with 1500mm high wall & 600mm high MS grill including 2100mm high steel gates at every 100 metres . |
| 112 | with brickwork structure with RCC column of size 300 x 300 mm@ 3Mtr C/c & RCC plinth Beam of size 300 x 300 at ground level and coping . (CPWD PAR 2023/5.8.1) |
| 113 | Supplying, installation, testing and commissioning of silent type dg sets, AMF panel, bus ducting/ cables from DG set to essential panels,synchronising panel where required, DG set enclosure room sound insulation/ ventillation/smoke exhaust as required, earthing of DG set system, control cabling fuel tank/piping, DG set exhaust piping/exhaust chimney as per CPCB norms, civil works connected with DG sets including foundation as required.(CPWD PAR 2023/6.3.1) |
| 114 | Supplying, Installation,testing and comissioning of grid interactive roof top solar photo voltaic power generation system including space frame.(CPWD PAR 2023/6.8.1) |
| 115 | Add 12.5% for electrification works Please Enable Macros to View BoQ information |