| 1 | Earth work in excavation in foundation in dry ordinary soil for building work including lift up to 1.5 m and lead up to 30 m and including back filling,Watering and ramming of excavated earth into the trenches or into the space between the structure the sides of foundation trenches or into the plinth with removal and disposal or surplus earth as directed by the engineer-in-charge up to a distance of 30 m from the foundation trenches required for proper completion of work. |
| 2 | Providing and laying Cement concrete M-10 (1:3:6) with A-20 including cost of all material, labour, mechanical mixing & vibration T&P etc. required for proper completion of work as directed by engineer-in-charge. |
| 3 | Providing and laying First class (M-150) Brick work in 1:4 CM with coarse sand F.M. more than 2.50 including all labour, material, T&P etc required for proper completion of work as directed by engineer-in-charge. |
| 4 | Providing and Fixing Centering and shuttering of R.C.C. work including cost of all material, labour and T&P required for proper completion of work for slab, lintels, sun shades, columns & walls etc. as directed by engineer-in-charge. |
| 5 | Providing and laying Reinforced Cement concrete M-20 (1:1.5:3) with A-20 including cost of all material, labour, mechanical mixing & vibration T&P etc. required for proper completion of work as directed by engineer-in-charge. |
| 6 | Providing and Laying cement coarse sand Plaster in 1:4 cement mortar with coarse sand F.M. more than 2.50 including cost of all material, labour and T&P etc complete. |
| 7 | Providing and Laying of two coats of approved quality Enamel Paint to give an even shade on doors and windows with cost of all material, labour, T&P and taxes etc required for proper completion of work as directed by engineer-in-charge. |
| 8 | Providing and Laying of two coats of approved quality water proof cement paint (All Weather Coat) including wall putty of 2 coats, primering over wall putty on new surface to give an even shade on walls with cost of all material,labour, T&P and taxes etc required for proper completion of work as directed by engineer-in-charge. |
| 9 | Providing & injection chemical emulsion for constructional anti termite treatment with drilling holes at junction of floors with wall & pillars,the application of chemical shall be as per relevant IS.Code and the rate of chemical shall also be as provided in the IS. Code including Quarterly inspection and provided required treatment for one year .required for proper completion of work As directed by the Engineer-in-charge/sqm |
| 10 | Supplying and Fixing of 3.8 cm country wood part panelled Door and window shutter including fixing of wooden cleats and stoppers and i/c fixing and adjustment of higes bolts locks handels springs fittings with necessary screw to be supplied etc complete in all respect as per directed by engineer-in-charge. |
| 11 | Providing and Fixing Teak wood work in frames of doors , windows, cleastory and other frames , wrought frames and fix in position etc required for proper completion of work As directed by the Engineer-in-charge. |
| 12 | Providing and laying 2.5 cm thick plain cement concrete floor with cement, approved sand and 2 cm graded approved stone grit, laid in panels finished with 3 mm floating coat of neat cement and marble dust including 8 cm thick base concrete consisting of brick ballast and fine sand & cement in prop. 12:6:1 including supply of all material ,labour and T&P etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 13 | Providing and Fixing Wiring Point for light with 1.5 sqmm fresh P.V.C. insulated multistrand single core copper conducted cable in PVC conduit pipe concealed in wall complete with 14 SWG copper earth continuity wire ,GP BOX, Modular type switches & celling rose/angle/batten holder on 3mm thickphenolic laminated backlite sheet etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 14 | Providing and Fixing Wiring Point for Fan/fresh air fan with 1.5 sqmm fresh P.V.C. insulated multistrand single core copper conducted cable in PVC conduit pipe concealed in wall complete with 14 SWG copper earth continuity wire ,Modular type switches & celling rose/angle/batten holder on 3mm thick phenolic laminated backlite sheet etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 15 | Providing and Fixing Wiring Point for Plug with 1.5 sqmm fresh P.V.C. insulated multistrand single core copper conducted cable in PVC conduit pipe concealed in wall complete with 14 SWG copper earth continuity wire ,Modular type switches & celling rose/angle/batten holder on 3mm thick phenolic laminated backlite sheet etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 16 | Providing and Fixing Wiring Point for Call bell with 1.5 sqmm fresh P.V.C. insulated multistrand single core copper conducted cable in PVC conduit pipe concealed in wall complete with 14 SWG copper earth continuity wire ,Modular type switches & celling rose/angle/batten holder on 3mm thick phenolic laminated backlite sheet etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 17 | Providing and Fixing Wiring Point for exhaust fan with 1.5 sqmm fresh P.V.C. insulated multistrand single core copper conducted cable in PVC conduit pipe concealed in wall complete with 14 SWG copper earth continuity wire ,Modular type switches & celling rose/angle/batten holder on 3mm thick phenolic laminated backlite sheet etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 18 | Supplying and wiring of submain with 2 no 4 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conducted cable in 20 mm dia heavy guage PVC conduit with 01 no 2.5 sq. mm. multistrand copper conducted cable As earth continuity wire drawn in conduit etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 19 | Supplying and fixing of 6 A to 32 A ratings, DP MCB, “C” curve, 10 kA breaking capacity i/c all material, labour T&P etc required for proper complition of work As directed by the Engineer-in-charge. |
| 20 | Supplying and fixing following rating double pole 240 V isolator in the existing MCB DB complete with connections testing and commisioning etc. required for proper complition of work As directed by the Engineer-in-charge.63(A) |
| 21 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. equired for proper complition of work As directed by the Engineer-in-charge. (But without MCB/RCCB/Isolator) |
| 22 | Providing & fixing water closet squatting pan (Indian Type W.C. pan ) with 100 mm sand cast iron p or s trap , 10 litre low level white PVC flushing cistern with manually control device with all fittings etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 23 | Providing and fixing 40mm dia P.V.C. waste pipe for sink and wash basin i/c P.V.C. waste fitting etc. required for proper complition of work As directed by the Engineer-in-charge. |
| 24 | Providing & fixing white vitreous china flat back wash basin of size 630x450mm including making all connections etc required for proper complition of work As directed by the Engineer-in-charge. |
| 25 | Providing & fixing brass long body bib Cock of approved quality including making all connections etc required for proper complition of work As directed by the Engineer-in-charge. |
| 26 | Providing & fixing PTMT Pillar cock of approved quality including making all connections etc required for proper complition of work As directed by the Engineer-in-charge. |
| 27 | Providing & fixing stainless steel kitchen sink with all fitings and making good the wall wherever required for proper complition of work As directed by the Engineer-in-charge. |
| 28 | Providing & fixing ball valve (Brass) of approved quality including making all connections etc required for proper complition of work As directed by the Engineer-in-charge. |
| 29 | Providing & fixing C.P. Brass angle valve for basin mixer and geyser points of approved quality including making all connections etc required for proper complition of work As directed by the Engineer-in-charge. |
| 30 | Providing & fixing C.P. Brass shower rose with 15 or 20 mm inlet including making all connections etc required for proper complition of work As directed by the Engineer-in-charge. |
| 31 | Providing & fixing fly proof galvanised M.S. wire gauge to window and clerestory windows using galvanised M.S. gauge with average width of aperture 1.4mm in both direction with wire of 0.63mm dia. (with 2nd class teak wood beading) etc required for proper complition of work As directed by the Engineer-in-charge. |
| 32 | Providing & Placing on terrace (at all floor levels) polythylene water storage tank ISI:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for Tank etc required for proper complition of work As directed by the Engineer-in-charge. |
| 33 | Providing and fixing CPVC pipes (20 mm) for hot and cold water supply including all fittings complete in all respect as per directed by engineer-in-charge. |
| 34 | Providing and fixing CPVC pipes (100 mm) for hot and cold water supply including all fittings complete in all respect as per directed by engineer-in-charge. |
| 35 | Providing and laying Reinforcement in cutting, bending, binding, welding and placing in Position inculiding cost of all material, labour and T&P etc. required for proper completion of work as per directed by engineer-in-charge. |
| 36 | Earth work in filling in ordinary soil including ramming and dressing the surface to the required levels and slopes including excavation , loading ,unloading , manual compaction and lead beyond 200 m. and upto 1.00 km. etc. required for proper completion of work as per directed by engineer-in-charge. excluding royalty. |
| 37 | Providing & Laying brick coba 12mm thick bat 7.50 cm Thick with gap of 15mm to each other ,over 20mm thick base of cemnt coarse sand mortar (1:4) mixed with water proofing compound spreading cement slurry mixed with arclic CC water proofing compound filled gap of cob and top of coba mortar mixed with w.p.c in 1:4 sand mortar finished smooth & top mashed false aquare 30x30 cm and side wall parapet shall be monolythic plaster wall upto 30cm ht. and junction and corner shall be rounded by brick ballast C.C sand masonary coba with top finished plaster mixed with acetic w.p.c @ 2%by wt.and including s/o all labour , material T&P complete for completion of work as per directed by engineer-in-charge. |
| 38 | Supply and fixing M.S. or iron work of small sizes and section such as M.S. grills/ stair case/ railing/ gates/trusher/racks etc. including supply of steel bolts, nuts wastage etc. and their fixing required for proper complition of work as per directed by engineer-in-charge. |
| 39 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. etc. required for proper completion of work as per directed by engineer-in-charge. Please Enable Macros to View BoQ information |