| 1 | CIVIL WORK |
| 2 | Excavation of foundation in ordinary soil within 50m initial lead and 1.5m initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge. |
| 3 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. ` |
| 4 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. In depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only) |
| 5 | P.C.C (1:4:8) with 40 mm size Crosser broken hard granite metal with cost of all labour & materials. |
| 6 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying |
| 7 | Rigid smooth centring and shuttering for R.C.C. works including false work and dismantling then after casting including cost of materials all complete. |
| 8 | R.C.C. work of M-25 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying |
| 9 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. |
| 10 | Solid C.C Block masonry work having crushing strength not less than 75 kg/sqcm of size 300 mm x 200 mm x 150 mm in cement mortar(1:4) in fdn. and plinth. (per cum) |
| 11 | Brick masonary using Flyash bricks in CM (1:6) in Super-Structure with cost of all labour and materials, etc complete.(230x110x80) |
| 12 | Providing and applying 16 mm thick cement plaster in 1:6 (cement:sand) to masonry or concrete surfaces, including surface preparation, wetting, and finishing to proper line, level, and smoothness, complete with curing for at least 7 days; the rate includes cost of all materials, labour, T&P, scaffolding, transportation, and all incidental charges as per specification and direction of the Engineer-in-Charge. |
| 13 | Providing and applying 12 mm thick cement plaster in 1:6 (cement:sand) to masonry or concrete surfaces, including surface preparation, wetting, and finishing to proper line, level, and smoothness, complete with curing for at least 7 days; the rate includes cost of all materials, labour, T&P, scaffolding, transportation, and all incidental charges as per specification and direction of the Engineer-in-Charge. |
| 14 | Providing and applying 6 mm thick cement plaster in 1:4 (cement:sand) to concrete surfaces, including cleaning and proper surface preparation with necessary roughening, application to required line, level, and smooth finish, and curing for at least 7 days; the rate includes cost of all materials, labour, tools and plants (T&P), scaffolding, and all incidental charges complete as per specification and direction of the Engineer-in-Charge |
| 15 | Providing, fitting and fixing Vitrified tile in floor of size 600x600 mm of approved make conforming to IS: 13755 laid on 20 mm thick cement mortar 1:4 (1 cement: 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-In-Charge |
| 16 | Skirting :- Dadoes - Supplying, fitting & fixing of Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 of size 60cm x 60cm coloured/printed series in dadoes, skirting and risers of steps of laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 17 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) over 100mm bed of dry brick ballast 40 mm nominal size well rammed, consolidated and grouted and fine sand and finishing the top smooth in proper slop including all complete |
| 18 | Supplying ,Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface at all elevations including all material & labour complete at all floors and all heights as per the direction of Engineer-In-Charge . |
| 19 | Supplying ,Providing & applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, including all material labour complete at all floors and all heights. (External Surface)at all elevations as per the direction of Engineer-In-Charge . |
| 20 | Providing and applying two coats of plastic emulsion paint of approved shade and make to interior plastered wall surfaces, including thorough surface preparation such as cleaning, minor repairs, and application of primer where required, to achieve a smooth and uniform finish; the rate includes cost and conveyance of all materials, labour charges, tools and plants (T&P), and all incidental expenses complete as per specification and direction of the Engineer-in-Charge. |
| 21 | GI Steel work in built up (round, square or rectangular hollow tubes) trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 22 | GCI Sheet - For Door and Shutter |
| 23 | Labour for Fixing G. C. I Sheet (Roof Sheeting) |
| 24 | Providing and applying one coat of approved primer to iron/steel surfaces, including thorough surface preparation by cleaning, scraping, and removal of rust, dust, oil, and other foreign matter to ensure proper adhesion, complete with uniform application to required finish; the rate includes cost of all materials, labour, tools and plants (T&P), and all incidental charges as per specification and direction of the Engineer-in-Charge. |
| 25 | Painting two coats with Synthetic Enamel paint to all surface |
| 26 | ELECTRICAL WORK |
| 27 | Point wiring in PVC conduit with Modular type Switch: Recessed/Surface wiring to Light Point / Fan Point / Exhaust Fan Point / Call Bell point with 1.5 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non- metallic PVC flexible conduit with 5 Amp. 250 Volt. modular type Switch of ISI marked and ceiling rose of ISI marked mounted on Modular box with cover of suitable size , 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard ). Group - A |
| 28 | Group - B |
| 29 | Group - C |
| 30 | Power Plug wiring in PVC conduit (2 x 4sq.mm): Recessed/Surface wiring for power plug with 2 x 4 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non- metallic PVC flexible conduit along with 1 x 2.5sq.mm. FR PVC insulated single core multistrand copper conductor for loop earthing as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.5) (For AC) |
| 31 | Supply and fixing of 25 Amp. Modular A. C. Starter Switch with 4 way Modular Plate and 4\\" x 4\\" Modular Board etc.complete with transportation, T&P and labour charges as per the direction of the Engineer-in-Charge. (For Air-Conditioner)(Make - Finolex / L&T / Anchor / Havels) |
| 32 | Supplying and fixing of suitable modular box deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3pin 15 / 16 amps socket outlet and 15 / 16 amps modular type switch, connection, painting etc as required. as per the direction of the Engineer-in-Charge. (make: Havells/Finolex/Anchor) |
| 33 | Circuit / Sub-Main wiring in PVC conduit (2 x 1.5sq.mm + 1 x 1.5sq.mm): Recessed/ Surface wiring to Sub-Main in 2 x 1.5 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694 / 1990 with 20 mm dia non- metallic heavy duty PVC flexible conduit 1.6mm along with 1 x 1.5sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.8.1) |
| 34 | Circuit / Sub-Main wiring in PVC conduit (2 x 2.5sq.mm + 1 x 1.5sq.mm): Recessed wiring to Sub-Main in 2 x 2.5 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694 / 1990 with 20 mm dia non- metallic heavy duty PVC flexible conduit 1.6mm along with 1 x 1.5sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.8.2) |
| 35 | Circuit / Sub-Main wiring in PVC conduit (2 x 4sq.mm + 1 x 1.5sq.mm): Recessed/Surface wiring to Sub-Main in 2 x 1.5 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694 / 1990 with 20 mm dia non- metallic heavy duty PVC flexible conduit 1.6mm along with 1 x 1.5sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.8.1) |
| 36 | Circuit / Sub-Main wiring in PVC conduit (2 x 6sq.mm + 1 x 2.5sq.mm): Recessed/Surface wiring to Sub-Main in 2 x 6 sq.mm. FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694 / 1990 with 25 mm dia non- metallic heavy duty PVC flexible conduit 1.6mm along with 1 x 2.5sq.mm. FR PVC insulated single core multistrand copper conductor as earth wire as required as per the direction of the Engineer-in-Charge. (Make of wire - Finolex / L&T / Anchor / Havels / V Guard) (SR Sl. No.1.8.4) |
| 37 | S/F SP MCB DB: Supply and fixing of the following way single pole and neutral, sheet steel, MCB dustribution board 250 Volts on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dib bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing as required as per the direction of the Engineer-in-Charge. (But without MCB/RCCB/Isolator) (SR Sl. No.2.3).B) 4 way, Single door (SR Sl. No. 2.3.2) |
| 38 | S/F \\"B\\" SERIES, SP MCB : Supply and fixing of 5 Amp to 32 Amp rating 240 Volts \\"B\\" searies Miniature Circuit Braacker (MCB) for lighting and otherr loads of the following poles in the existing MCB DB ISI marked comple with connections, testing and commissioning etc. as required as per the direction of the Engineer-in-Charge. (SR Sl. No.2.6).A) Single Pole (SP) (SR Sl. No.2.6.1) |
| 39 | Supply and fixing of following rating two pole [ phase and neutral) 230 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required as per the direction of the Engineer-in-charge |
| 40 | G.I. earth pipe electrode with salt and charcoals: Earthing with G.I. earth pipe 3 Mtrs. Long 40mm dia of ISI marked including accessories and providing masonary enclosure with cover plant having locking arrangement and watering pipe etc. as per the direction of the Engineer-in-Charge. (with Charcoal and salt) (SR Sl. No. 3.2) |
| 41 | S/L No.6 SWG G.I. Wire in ground: Supply and laying of No.6 SWG G.I wire ISI Marked at 0.5 meter below ground level for conductor eath electrode including soldering etc. as required as per the direction of the Engineer-in-Charge. (SR Sl. No. 3.8) (For 2 no. Earthing) |
| 42 | Supplying and fixing of TV antenna socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required. |
| 43 | Supply and stringing of 10 Sq.mm twin core PVC insulated PVC sheathed aluminum wire support with No.10 G.I. wire and binding wire including cost of materials, labour, T&P and transportation etc. complete as per direction of the Engineer-in-Charge. |
| 44 | SITC of Main Switches: Supply, installation, Testing and Commissioning of Main Switches IS- 13940 Part-III / 1983) of following capacity on existing surface / wall mounting and complete with HRC Fuse lionks, interconnections, earthing, etc. as required as per the direction of the Engineer-in-Charge. (Make- SEIMENS/ HPL / L&T / Anchor / Havels /C&S/ RK)(SR Sl. No.2.15). A) 140 Amp D.P Main Switches. (SR Sl No.2.15.1) |
| 45 | Supply and fixing of Baton integrated 20 Watt. LED Batten Tube Light intergral sleek extrudedmpolycabonate LED Channel with white acrylic cover etc. complete with transportation, T&P and labour chares as per direction of the Engineer-in-Charge. (MAKE: BAJAJ / HAVELLS / CROMPTON / PHILLIPS) Please Enable Macros to View BoQ information |