| 1 | Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 3 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in Roof, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and as directed. |
| 4 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 5 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja, floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 6 | M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 7 | M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 8 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 9 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 10 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 11 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 12 | M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 13 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 200Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 14 | M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 15 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 16 | Complete removal of existing treatment & levelling of wall/ceiling surface existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface complete all as specified and as directed. |
| 17 | M&L for preparation of new plastered surfaces of wall and ceiling and applying two or more coats of acrylic distemper 1st quality (ready mixed) having VOC content less than 50 gms/ltrs of required shade and colour complete as per manufacturer's specification over a coat of 1mm(average) thick wall care putty complete all as specified and directed. |
| 18 | M&L for preparation of newly plastered surfaces of walls and applying Two or more coats of 100% Premium exterior acrylic emulsion paint of required shade, having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all specified and as directed. |
| 19 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 20 | M&L for applying two component structural grade Shorter Chan Nano Base and Catalyst based polymer modified reinstatement mortar, where local spalling has taken place or shuttering is not possible. The mortar can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimum compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadiene emulsion for use as a bonding aid and gauging liquid for cementitious system to be mixed with cement slurry before the application of modified polymer mortar. The bonding agent should have minimum compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimum flexural strength 6.5N/mm2 upto 25 mm average thickness complete all as specified and as directed. Note : Surface area shall be measured and paid for each 6mm thick layer |
| 21 | M&L for applying a coat of Nano technology based water proofing compound (1 part powder: 1 part liquid), of desired consistency with nylon brush @ 5 sqm/kg coverage over vertical/horizontal surface of RCC roof and parapet complete all as specified and as directed. |
| 22 | M&L for applying Nanotechnology based Anti-corrosive with high strength carbon Fiber based shorter chain Epoxy coating (Bond Coat) of finest quality, high strength, high penetration, durable, UV resistant, high scratch/ impact resistant, bacteria resistant and thermally stable, Semi transparent, mixed in proportion (4 Base : 1 Hardner) in required consistency @ 8 sqm/kg over the entire prepared surfaces of roof/parapet/sunken floor complete all as specified and as directed.Note : 1. Rate shall include for making surface clean, dust free, dry, and free of wax, grease, oil, loose or peeling particle, and other foreign materials.2. During application ambient temperature is preferred. Frost, fog, or damp conditions should be avoided. |
| 23 | M&L for applying two coats of Nanotechnology based water-based one pack epoxy based Nano barrier coat, durable, highly water repellent, UV resistant, fungus/ algae/ bacteria resistant, thermally insulating and elastomeric including high capillary pressure resistance, anti-bacterial, low VOC, UV resistance, high coverage area @ 6.5 sqm/kg in each coat complete all as specified and as directed.Note : 1. Rate shall include for making surface clean, dust free, dry, and free of wax, grease, oil, loose or peeling particle, and other foreign materials.2. During application ambient temperature is preferred. Frost, fog, or damp conditions should be avoided. |
| 24 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm complete all as specified and as directed.Note - Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces |
| 25 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and as directed. Note - Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces. |
| 26 | Taking down shutter of any description exc 1 Sqm n exc 2 Sqm each and refixing in the same opening after necessary repairs complete all as specified and as directed. |
| 27 | S & F factory made solid PVC door frame of size 40mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 28 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. Please Enable Macros to View BoQ information |
| 29 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. Please Enable Macros to View BoQ information |