| 1 | Schedule 'A' B/R |
| 2 | Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre depth for foundation, etc., or not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth for shafts, cesspits, manholes, pier holes, etc., and getting out in loose/soft soil, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Removing excavated soil not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Material & Labour for Hard-core of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply only Moorum/red bajri, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Material & Labour for forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing to required size, shape, etc. not exceeding 1.5 Metre high from base, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material & Labour for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material & Labour for Pre-cast cement concrete block masonry (Type C-1, 1:3:6 (20mm aggregate) in with solid blocks, exc. 10 cm in width and setting in Cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Material & Labour for rendering 15mm thick on concrete surfaces in cement mortar 1:4 and even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material & Labour for 10mm thick rendering in Cement Mortar 1:6 to concrete surfaces trowelled to even & smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Material & Labour for preparing surfaces plastered or un-plastered new surface of walls applying two coats of oil bound distemper over a coat of primer over layer of 3mm smooth Putty finish as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. Note: - After painting, cleaning of all floors, glass & Furniture by own arrangement. |
| 13 | Material & Labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm per litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of smooth putty all as per the manufacturer’s instructions, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply & Fixing for factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick galvanized steel frame (30mm x 18mm) 2 Nos, sliding sash (30mm x 18mm) 2nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate excludes cost of glass and includes all other connected accessories) area not exceeding 2.00 sqm each fixed from ground floor to any height of floors, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply & Fixing 7mm thick aluminium grills of make \\"Deco-grill\\" model DG 104 surrounded by aluminium 'C' channel and size of opening 75mm x 75mm all as specified and directed fixed from ground floor to any height of floors, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & Fixing 2nd class HW plain chowkhats and framed, rebated on the solid rounded or chamfered put together with glue pinned at joints, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & Fixing 35mm thick Flush Shutter, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/ frame to match commercial type on both side, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply & Fixing 5mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply & Fixing 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & Fixing 150mm long Extruded Aluminium alloy handles, fabricated type, and anodised, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply & Fixing 150mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply & Fixing 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply & Fixing 140mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material & Labour for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in Providing precast cement concrete in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weathering’s, throating etc. and setting in mortar complete with joints to match set in cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material & Labour for Mild CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge. |
| 26 | -ditto- all as per item No.24 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Dismantling/ Demolition of brick work or stone masonry or RCC Pre cast Jali & Jafari built in cement mortar including all quoins, arches, pillars, etc., complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material & Labour for Cement concrete of Nominal Mix of M-20 (1:1.5:3) by volume of 12.5mm graded course aggregate, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply & Fixing Glass dividing strips, 3mm thick having width of 28mm, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Material & Labour for 10mm thick vitrified tile of area exceeding not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15mm thick Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 31 | Material & Labour for 10mm thick vitrified tile of area exceeding not exceeding 0.36 sqm in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match over mortar 15mm thick Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply only liquid water proofing compound, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Material & Labour for Mild steel, plain, black sheet 1.60mm thick in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Material & Labour for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints over red oxide zinc chrome primer, complete all as specified and directed by Engineer-in-Charge. |
| 35 | Providing and fixing individual stainless steel (SS 304 grade) letters of approved font and size, made out of minimum 2mm thick sheet, laser cut, with brushed/mirror finish, including necessary SS studs, spacers, screws and fixing accessories, fixed to steel gate/ACP panel surface at required height and alignment, complete all as specified and as directed by Engineer-in-charge.Items includes marking, drilling, fixing with proper template, maintaining uniform spacing and level, and ensuring minimum 15-20mm projection from background surface. Edges to be smooth and finish free from defects. All fixing to be concealed from front side.The rate shall include cost of all materials, fabrication, polishing, transportation, labour, tools & plants and scaffolding if required for complete installation, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Demolition of reinforced cement concrete in any description and any position, including removing of demolished materials from work site, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Demolition of cement concrete in any description and any position, not otherwise specifically provide for including removing of demolished materials from work site, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed by Engineer-in-Charge. |
| 39 | Material & Labour for RCC nominal mix Type B-0, 1:2:4 Type B-1 using 20mm graded stone aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 40 | Material & Labour for RCC nominal mix Type B-0, 1:2:4 Type B-1 (using 20mm graded stone agg) as in Beams and alike, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Material & Labour for RCC nominal mix Type B-0 1:2:4 Type B-1 using 20mm graded stone aggregate, as in Columns, pillars, piers, posts and struts, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Use and waste of formwork to the sides of concrete footing, base of columns, plinth beams and similar work for vertical or to batter rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge. |
| 43 | Use and waste of formwork to sides and soffits of beams, bands and the like for rough finished surface of concrete, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Use and waste of formwork to the sides of rectangular columns for rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge. |
| 45 | Removing excavated soft rock exceeding 500 Metre but not exceeding 1.50 km and depositing outside MoD land where directed, complete all as specified and directed by Engineer-in-Charge. |
| 46 | Material & Labour for 100mm thick Plain Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base of floors, complete all as specified and directed by Engineer-in-Charge. |
| 47 | Material & Labour for Porbandar stone masonry, well bonded, bedded and solidly hearted built in Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 48 | Material and labour for glazed ceramic coloured tiles 300 x 450 x 7 to 8mm thick, first quality, as on skirting, dados, walls etc., set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 10mm thick rendering in cement mortar 1:3, complete all as specified and directed by Engineer-in-Charge. |
| 49 | Material & Labour for 20mm thick granite (of any type) work (table rubbed and polished) for steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm screed bed of cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge. |
| 50 | Material & Labour for 20mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 10mm backing coat of cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge. |
| 51 | Schedule 'A' E/M |
| 52 | Taking down carefully copper /aluminium point wiring (light, fan, socket or power point) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good distribution surfaces of walls, floors, etc., complete all as specified and directed by Engineer-in-Charge. |
| 53 | Taking down electric connections and taking down old unserviceable MCB SPN/SP/TPN/MS, Meter Box, DB's etc., of any capacity, complete all as specified and directed by Engineer-in-Charge. |
| 54 | Taking down unserviceable sub main wiring of any size and including PVC conduit and accessories & removing from site, complete all as specified and directed by Engineer-in-Charge. |
| 55 | Material & Labour for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 1.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- |
| 56 | One light point / fan point controlled by one, one way switch |
| 57 | One 3 pin 6 Amps socket outlet on same board |
| 58 | One 3 pin 6 Amps socket outlet on independent board. |
| 59 | Material & Labour for Point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multi-strand copper conductor FRLS cable 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply & fixing modular switch 1 way, 16 Amps, 1 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply & fixing modular socket, 6/16 Amps, 2/3 pin combined 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply & fixing modular switch 1 way, 6 Amps, 1 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply & fixing modular socket, 6 Amps, 2/3 pin combined 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. |
| 64 | Supply & fixing ceiling rose, surface Bakelite, 65 x 17 mm three terminals (ISI Marked), complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supply & Fixing wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply & Fixing in replacement of Smart motion LED Luminaires recessed/surface mounted 15 watt 6500K system efficiency having smart motion sense radius 4.5 meter, not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, complete all as specified and directed by Engineer-in-Charge. Note : Cutting of wall of appropriate size of fan and making good in cement 1:3 or cement concrete 1:2:4 type B-1 as depth of cut required and finishing properly to match the surfaces to fix the Exhaust fan is inclusive job in each of item. |
| 68 | Supply & Fixing Sheet metal enclosure (factory made) double door for distribution board (when MCB's are to be used) Single pole neutral 240 V, 4 ways with 200 Amp rated bus bar connection with suitable size of thimbles, complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and Neutral current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 71 | Material & Labour for sub main wiring with two single core 2 x 4 Sqmm PVC (FRLS) insulated multi-stranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 2.5 Sqmm single core single strand copper conductor as continuous earth wire in green colour connected to common earth dolly, complete all as specified and directed by Engineer-in-Charge.Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit. |
| 72 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltr, complete all as specified and directed by Engineer-in-Charge.Make: Blue star/Voltas/ Usha Please Enable Macros to View BoQ information |
| 73 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltr, complete all as specified and directed by Engineer-in-Charge.Make: Blue star/Voltas/ Usha Please Enable Macros to View BoQ information |