| 1 | Schedule 'A' |
| 2 | Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as specified and as directed. |
| 3 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Excavation over areas not exc 1.5m deep and getting out in soft and loose soil and removing the excavated material/soil upto a distance of 50m complete all as specified and directed. |
| 5 | ditto as per items no. 03 but for each additional 1.5m or part thereof in depth beyond the first 1.5m upto 3.0 m depth complete all as specified. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soft/loose soil complete all as specified and as directed. |
| 7 | Removing excavated material/soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 8 | M & L for PCC 1:4:8 Type D2 (Nominal mix) (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed.(Note:- using dimapur sand) |
| 9 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 10 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:4) complete all as specified and directed. |
| 11 | M & L for brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed. |
| 12 | M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed.Note : (i) WPC will be measured and paid separately (ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account. |
| 13 | M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed. |
| 14 | Supply only intergral water proofing compound complete all as specified and directed. |
| 15 | M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 16 | M&L for preparation of surfaces plastered or unplastered new surface on wall and applying two coats of white washing complete all as specified and directed. |
| 17 | M&L for PCC in cement concrete type B-1 ,1:2:4 (using 20 mm graded aggregate) as in coping complete all as specified and directed. |
| 18 | M&L for 25 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified. |
| 19 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand) |
| 20 | M&L hardcore of gauge n exc 63mm, broken stone or boulders deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface completed all as specified and directed. |
| 21 | M&L for 75 mm thick cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed by the Engineer-in-Charge. |
| 22 | M&L for 100 mm thick cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed by the Engineer-in-Charge. |
| 23 | M&L for 100 mm thick cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed by the Engineer-in-Charge |
| 24 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 25 | S&F Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile including 10mm thick cement mortar backing in CM (1:4) as backing coat to receive tiles complete all as specified and directed. |
| 26 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed in CM 1:3 complete all as specified and directed. |
| 27 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out in soft and loose soil complete all as specified and directed. |
| 28 | M & L for PCC 1:3:6 Type C2 (Nominal mix) (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed.(Note:- using dimapur sand) |
| 29 | S&F Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified. |
| 30 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.56mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws as specified. |
| 31 | M&L for structural steel work in Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Grade E-250) quality-A complete all as specified and as directed. |
| 32 | S&F Mild steel Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc conforming to Fe 290-W (Grade E-165) quality-A complete all as specified and as directed. |
| 33 | S&F steel work in tubular or square trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A) complete all as specified and directed. |
| 34 | S&F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde-E-250 quality-A) complete all as specified and as directed. |
| 35 | S&F rotational moulded polyethylene water storage tank, ISI marked, 500 litres capacity of multilayered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including all necessary inlet/outlet connections complete all as specified in SSR Part-I and as directed. |
| 36 | S&F 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210 g m s) complete all as specified and directed. |
| 37 | M&L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 38 | M&L for RCC 1:2:4 Type B1 nominal mix (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; basesfor columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 39 | M&L for RCC (Nominal Mix) Type B1, 1:2:4(using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 40 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 41 | M&L for TMT bars 8 to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 42 | Ditto as per items No 40.00 here-in-above but 5mm and over upto & incl 10mm dia in stirrups, spaces and binders complete all as specified and directed. |
| 43 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rough finished surface of concrete complete all as specified and directed. |
| 44 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping), fair finished surface of concrete complete all as specified and directed. |
| 45 | Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and as directed. |
| 46 | Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified and as directed. |
| 47 | S&F butt hinges, 100mm extruded aluminum alloy with galvanized mild steel hinges pin anodised and fixed type B-21 complete all as specified and directed. |
| 48 | S&F 150 mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed. |
| 49 | S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 50 | S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 51 | S&F 15mm bore bib taps, cast copper alloy, chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed. |
| 52 | S&F Angle stop valve of PTMT of any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 53 | S&F Pillar taps, 15mm dia cast copper alloy, with capstan heads, chromium plated, but fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 54 | S&F Soap dish, CP, white, approximate size 160x 160x90mm Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engr-in- Charge. |
| 55 | S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 56 | S&F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 57 | S&F in Gun-metal (ISI marked), globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20mm bore and fixed complete all as specified and directed. |
| 58 | S&F PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and directed. |
| 59 | S&F PVC SWR pipes 75 mm bore single socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and directed. |
| 60 | S&F 110mm bore PVC (SWR) bends complete all as specified and directed. |
| 61 | S&F 75mm bore PVC (SWR) bends complete all as specified and directed. |
| 62 | S&F PVC (SWR), junction single, (Single T) equal or unequal 110mm dia with access door complete all as specified and directed. |
| 63 | S&F PVC (SWR), junction single, (Single T) equal or unequal 75mm dia with access door complete all as specified and directed. |
| 64 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including setting and jointing with solvent cement complete all as specified and directed. |
| 65 | S&F 75mm dia PVC (SWR) Multi floor trap, plain with grating including setting and jointing with solvent cement complete all as specified and directed. |
| 66 | S&F PVC (SWR) reducer for 110mm bore pipe complete all as specified and directed. |
| 67 | M&L for PVC (SWR) vent cowl of bore 75mm complete all as specified and directed. |
| 68 | S&F PVC (SWR) WC connector with lip ring 110 mm. complete all as specified and directed. |
| 69 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 70 | S&F vitreous china wash basin white, flat back of size 450x300mm including 32mm dia PVC waste pipe CP brass waste coupling 32 mm dia , pair of MS angle brackets or MS fastener/ bolts for fixing arrangements 450mm long pvc connection with PVC nut and washer complete all as specified and directed. |
| 71 | S&F PVC connection 15 mm x 450 mm including brass check nut at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed. |
| 72 | M&L for Vitreous china urinal half stall type, white with grating and union for discharge pipe incl providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal back in cement ; fixing automatic flushing cistern with brackets, waste coupling (half or full threaded) 32 mm bore suitable for urinal, flush pipe, waste pipe, grating and union for discharge pipe complete all as specified and directed. |
| 73 | S&F in repair Vitreous China Squatting pan, \\"Orissa\\" pattern, size 580 x 440 mm white with integral foot rests and 10 litres PVC capacity valve less, Syphonic action type, Flushing cistern, low level, white with inlet, ball valve, float and handle including brackets (SLIM LINE or equivalent) including PVC Flush pipe 32 mm dia., and setting the trap and pan in lime concrete 1:2:5 minimum 150 mm thick all round and finished just below level of rim of pan to receive the floor finishing complete all as specified and directed. |
| 74 | M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick set jointed with grey cement and pigments and pointed in neat cement slurry in floors including 20mm thick sreed bed in CM 1:4 complete all as specified and directed. |
| 75 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in lintel upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, facing courses, parapets and railing upto 60 cm in height , coping, kneelers, apex stones, bed plates, kerbs, surface channel not provided for in item 4028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 76 | M&L for cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 77 | M&L for Precast cement concrete type B1 1:2:4 (Nominal mix) using 20mm graded crushed stone aggregate as in cover slab, set in cement mortar 1:6 complete all as specified and as directed. |
| 78 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed. |
| 79 | S& F reinforced concrete pipes class NP-2 laid and jointed complete with collars as directed by engineer in charge for the following dia (a) 450 mm |
| 80 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed)One light point controlled by one, one way switch |
| 81 | One ceiling/exhaust fan point controlled by one, one way switch |
| 82 | One socket outlet 5 Amps 5 pin on independent board |
| 83 | One socket outlet 5 Amps 5 pin on same board with other switches |
| 84 | All as per item No. 79.00 here in before but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed. |
| 85 | S&F modular switch piano, 6 Amps, single pole, one way complete all as specified and directed. |
| 86 | S&F modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. |
| 87 | Supply and fixing modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed. |
| 88 | S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 89 | S&F modular switch piano, 16 Amps, single pole, one way complete all as specified and directed. |
| 90 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed. |
| 91 | S&F MCB single pole and neutral 40 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 92 | S&F MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 93 | S&F PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250mm x 200mm x 50 mm deep medium quality ISI marked complete all as specified and directed. |
| 94 | S&F LED light fitting 1x20 Watt , 220 V , AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 95 | Supply and Fixing ceiling fans complete with blades, down rods including electronic regulator and remote accessories , 230 V, 1200 mm sweep. Min air deleivery 210 CFM with service value 6.00 BEE . Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 96 | S&F metal exhaust fan AC single phase 230 volts of size 380mm sweep with louvre complete fixed and opening of wall with suitable MS bolts, grouted to wall and connecting up including provision of cable from connector to fan with flexible cable 24/0.2mm with copper conductor and necessary fitting complete all as specified and directed. |
| 97 | S&F building security light fitting new generation energy saving & environmental friendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP-66 high power LED light 25 watt including suitable size of wall bracket and connecting complete all as specified and directed. |
| 98 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed. |
| 99 | M&L for Drilling and tapping cast iron / ductlile iron water mains (in position) for branch connections of the internal dia 20mm complete all as specified and directed. |
| 100 | S&F gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of bore 20mm complete all as specified and directed. |
| 101 | M&L for laying steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for 20 mm dia bore complete all as specified and directed. |
| 102 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.) |
| 103 | Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable complete all as specified and directed. |
| 104 | Supply, laying, Jointing and testing in repair of LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |
| 105 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed. (Note: Earth strip beyond 7.5 m length will be measured & paid separately) Please Enable Macros to View BoQ information |