| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil |
| 3 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed for lead up to 25 meter from cutting edge in All kinds of soil. |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying cement concrete in Protection walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size.) |
| 7 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete. |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improveworkability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level |
| 9 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improveworkability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used asper design mix is content considered payable or recoverable separately All works above plinth level upto floor V level |
| 10 | Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein. |
| 11 | Reinforcement for RCC works including straightening, cutting, bending, placing in position and binding all complete all work up to plinth level and above plinth level , Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 12 | Centering and shuttering including strutting, propping, etc and removal of form work for foundations , footings ,bases of columns etc. |
| 13 | Centering and shuttering including strutting, propping, etc and removal of form work for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 14 | Centering and shuttering including strutting, propping, etc. and removal of form work for columns, pillars, piers etc. |
| 15 | Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms. |
| 16 | Centering and shuttering including strutting, propping, etc and removal of form for Weather shades, chajjas, corbels etc. including edges |
| 17 | Centering and shuttering including strutting, propping, etc and removal of form for Stairs (excluding landings) except spiral staircases. |
| 18 | Centering and shuttering including strutting, propping, etc and removal of form work for lintels, beams, girders, bressumers and cantilevers all complete. |
| 19 | Centering and shuttering including strutting, propping, etc and removal of form for edges of slabs.(under 20 cm). |
| 20 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 21 | Brick work with common burnt clay (Non-Modular) bricks of class designation 7.5 in foundation and plinth including curing complete in Cement mortar 1:6 ( 1 cement : 6 coarse sand). |
| 22 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 23 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement: 3 coarse sand). |
| 24 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 25 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 26 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1:6 ( 1 cement : 6 fine sand ) |
| 27 | 6mm cement plaster to ceiling of mix 1 : 3 (1 cement: 3 fine sand) |
| 28 | 15mm Cement plaster finished with a floating coat of neat cement of mix 1 : 3 ( 1 cement : 3 fine sand) (septic tank/sump tank). |
| 29 | Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections |
| 30 | Making of Groove 12mmx10mm between brick and RCC |
| 31 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 32 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) including curing complete, but excluding the cost of nosing of steps etc.complete, 40mm thick with 20 mm nominal size stone aggregate. |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of tile 60x60cm. |
| 34 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.Size of tile 600x600 mm |
| 35 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.In all colours, shades, except White, Ivory, Fume Red Brown. |
| 36 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 300x450mm as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 37 | Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete. |
| 38 | Extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. |
| 39 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 40 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 41 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood. |
| 42 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size). |
| 43 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws (35mm thick) |
| 44 | Providing & fixing glazed shutters for doors , windows and clerestory windows using 10 Kg / Sqm. (4 mm thick) float glass panes, incl. ISI marked M.S pressed butt hinges bright finished off required size with necessary screws 35 mm thick of Second class deodar wood |
| 45 | Providing and fixing glass panes , with wooden fillets wherever : Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) |
| 46 | Providing and fixing wire gauze shutters 35 mm thick using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class deodar wood |
| 47 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc |
| 48 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 300 x 16 mm |
| 49 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 250 x 16 mm |
| 50 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm |
| 51 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm |
| 52 | Providing and fixing Aluminium hanging floor door stopper ISI marked anodized (anodic coating not less than grade AC 10 as per IS 1868 ) tranparent or dyed to required colour or shade with nuts and screws etc. complete twin rubber stopper. |
| 53 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 125mm |
| 54 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 100mm |
| 55 | Providing and fixing bright finished brass hard drawn hooks and eyes 150 mm |
| 56 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 57 | Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) .Medium shade using 50% white cement and 50% ordinary cement. |
| 58 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 59 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 60 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 61 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 62 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer, |
| 63 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 64 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 65 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 66 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 67 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 68 | Providing and fixing C.P. fittings of approved brand Kerovit. Cere, Hindwre or equivalent. C P bib cock long nose |
| 69 | C P bib cock short body |
| 70 | C P angle valve |
| 71 | PVC connection |
| 72 | C P Towel rod |
| 73 | CP Towel Ring |
| 74 | PVC waste pipe with Coupling |
| 75 | CP Grating |
| 76 | Soap Dish |
| 77 | Steel shelf |
| 78 | Shower with arm |
| 79 | Health Fauset Jet |
| 80 | S S Sink size 610x460mm bowl depth 200mm |
| 81 | Ball Valve 25mm CPVC |
| 82 | Ball Valve 32mm CPVC |
| 83 | Tank nipple 25 mm dia |
| 84 | providing n fixing of wash basin with ci bracket 15 mm cp piller cock incl 32mm brass waste pipe incl painting of fitting and brackets cutting and making basin size 630x450 |
| 85 | Providing n fixing of white viterious china pedistal for washbasin |
| 86 | Providing n fixing white vitreous china pedistal type water closet european type WC pan with seat and lid 10 ltr with pvc flushing tank incl flushing pipe with manually controlled complete |
| 87 | Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C. pan) with seat and lid with C.P. brass hinges and rubber buffers, 10 liter low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm overflow pipe with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:18.68.1 White vitreous china dual purpose WC pan with white solidplastic seat lid with white vitreous china flushing cistern andC.P. flush bend |
| 88 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively. |
| 89 | Providing and fixing of 1HP motor for water suppy in water storage tank complete fittings |
| 90 | Providing, fixing and commissioning of submersible borewell including fixing of motor (complete job with 32mm bore pipe under the ground and 20mm outlet pipe . |
| 91 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 20mm nominal outer dia pipes. |
| 92 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25mm nominal outer dia pipes. |
| 93 | Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 20mm nominal outer dia pipes. |
| 94 | Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 25mm nominal outer dia pipes. |
| 95 | External work including trenching, refilling etc. 25mm nominal outer dia pipes |
| 96 | External work including trenching, refilling etc. 32mm nominal outer dia pipes |
| 97 | External work including trenching, refilling etc. 40mm nominal outer dia pipes |
| 98 | Providing and fixing on wall face unplasticized rigid PVC pipe conforming to IS 13592 type A incl jionting with seal ring of pipe 150 mm dia Pipe |
| 99 | 150 mm dia PVc plain bend |
| 100 | 110 mm dia pipe |
| 101 | 110 mm dia PVc plain bend |
| 102 | 110mm dia PVc door bend |
| 103 | 110mm dia Tee |
| 104 | PVC Pipe 75mm dia |
| 105 | Pvc Floor Trap 75 mm |
| 106 | PVC door bend 75 mm |
| 107 | PVC Plain bend 75 mm |
| 108 | 75mm dia Tee |
| 109 | 110mm dia Collar. |
| 110 | 110mm dia P-Trap |
| 111 | 110mm PVC Prince Cliff |
| 112 | 110mm x 80mm dia Reducer |
| 113 | 110mm 45 deg Bend |
| 114 | 110mm dia PVC Cowel Caps |
| 115 | Brick MANHOLE (1.5x1.5') with PVC cover |
| 116 | Brick MANHOLE (2' x2' ) with PVC cover |
| 117 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 118 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Coupler 110mm. |
| 119 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Single tee with door 110x110x110 mm. |
| 120 | Providing & fixing PVC pipes 6 kg/ cm2 pressure excluding PVC fittings, jointing with adhesive/ seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion of approved make Supreme/ Finolex/ Astral or equivalent. 110mm |
| 121 | Providing & fixing PVC pipes 6 kg/ cm2 pressure excluding PVC fittings, jointing with adhesive/ seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion of approved make Supreme/ Finolex/ Astral or equivalent. 80mm |
| 122 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. White Agaria Marble Stone 18mm |
| 123 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 124 | Providing and fixing un-plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length. |
| 125 | Providing and fixing CP Neeple. |
| 126 | Providing and fixing C.P Cup. |
| 127 | Providing and fixing CP Grating. |
| 128 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. Rectangular shape 453x357 mm |
| 129 | Providing and fixing soil, waste and vent pipes : 100 mm dia, Sand cast iron S and S pipe as per IS:1729 |
| 130 | Providing and fixing Ball Valve (brass) of approved quality,high or low pressure with plastic floats complete. 25 mm |
| 131 | Providing and fixing Ball Valve (brass) of approved quality,high or low pressure with plastic floats complete. 20 mm |
| 132 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin-charge.With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 133 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 134 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 135 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 136 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 137 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 138 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 139 | Disposal of surplus earth for average lead of 1.0 Km. |
| 140 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. 40 mm thick with 20mm nominal size stone aggregate. complete (drain flooring) |
| 141 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 180 x 150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 142 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 143 | Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design: Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating |
| 144 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti termite treatment. Treatment of soil under existing floors using chemical emulsion (Chlorophriphos/Lindane E.C. 20% with 1% concentration) @ one litre per hole, 300mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floor: |
| 145 | Dewatering for underground water that accumulates due to seepage and other unforeseen reasons using a 2 HP motor pump |
| 146 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge: 1:4:8 or richer mix (i/c equivalent design mix) |
| 147 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 148 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In mud mortar |
| 149 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below |
| 150 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead : Of sectional area 40 sqcm. and above. |
| 151 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet |
| 152 | Disposal of unserviceable material Lime, moorum, building rubbish for average lead of 1.0 Km. |
| 153 | Carriage of material by mechanical transportation. Sand average lead 20 Km |
| 154 | Stone aggregate 40mm and above Av. Lead 20.0 Km By M.T. |
| 155 | Stone agregate below 40mm. average Lead 20.0 Km By mechenical means. |
| 156 | Bricks, average Lead 5 Km By mechenical means. |
| 157 | Deduction of brick Please Enable Macros to View BoQ information |