| 1 | Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no. WG-DM/PW, 1.8.1 | Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no. WG-DM/PW, 1.8.1 |
| 2 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW, 1.7.18 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW, 1.7.18 |
| 3 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW, 1.7.19 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW, 1.7.19 |
| 4 | Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WGPW/CW, 1.7.25 | Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WGPW/CW, 1.7.25 |
| 5 | Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW, 1.7.20 | Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW, 1.7.20 |
| 6 | Supplying and erecting modular type (two module) electronic dimmer 600/650W on provided plate and box with wiring connections complete., 1.6.21 | Supplying and erecting modular type (two module) electronic dimmer 600/650W on provided plate and box with wiring connections complete., 1.6.21 |
| 7 | Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete., 1.6.1 | Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete., 1.6.1 |
| 8 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter on provided plate and box with wiring connections complete, 1.6.10 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter on provided plate and box with wiring connections complete, 1.6.10 |
| 9 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete, 1.6.2 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete, 1.6.2 |
| 10 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete, 1.6.11 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete, 1.6.11 |
| 11 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module complete, 1.6.32 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module complete, 1.6.32 |
| 12 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module complete, 1.6.28 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module complete, 1.6.28 |
| 13 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module complete, 1.6.27 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module complete, 1.6.27 |
| 14 | Supplying and erecting modular type buzzer 220/250V on provided plate and box with wiring connections complete , 1.6.19 | Supplying and erecting modular type buzzer 220/250V on provided plate and box with wiring connections complete , 1.6.19 |
| 15 | Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW, 1.3.6 | Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW, 1.3.6 |
| 16 | Supplying & erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW, 1.3.7 | Supplying & erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW, 1.3.7 |
| 17 | Supplying & erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW, 1.3.8 | Supplying & erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW, 1.3.8 |
| 18 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification no. WG-MA/CON., 1.2.8 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification no. WG-MA/CON., 1.2.8 |
| 19 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no SW-MCB, 5.3.13 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no SW-MCB, 5.3.13 |
| 20 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB., 5.6.3 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB., 5.6.3 |
| 21 | Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB, 5.3.3 | Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB, 5.3.3 |
| 22 | Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC., 1.1.10 | Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC., 1.1.10 |
| 23 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 8 ways (8 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB, 5.4.10 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 8 ways (8 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB, 5.4.10 |
| 24 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation, 2.9.13 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation, 2.9.13 |
| 25 | Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF, 2.9.14 | Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF, 2.9.14 |
| 26 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB, 5.4.9 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB, 5.4.9 |
| 27 | Supplying, erecting & marking DP MCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB, 5.3.9 | Supplying, erecting & marking DP MCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB, 5.3.9 |
| 28 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control, , LPP | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control, , LPP |