|
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil DSR Code No. 2.8.1 |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. DSR Code No. 2.25(a) |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR Code No. 2.27 |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). DSR Code No. 4.1.10 |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement:1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 4.1.2 |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 4.1.3 |
| 7 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 4.2.2 |
| 8 | Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) DSR Code No. 4.5.1 |
| 9 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. DSR Code No. 4.12 |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR Code No. 5.1.2 |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources):DSR Code No. 5.2.2 |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 5.3 |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.1) Foundations, footings, bases of columns, etc. for mass concrete DSR Code No. 5.9.1 |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.3) Suspended floors, roofs, landings, balconies and access platform. DSR Code No. 5.9.3 |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.5) Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR Code No. 5.9.5 |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.6) Columns, Pillars, Piers, Abutments, Posts and Struts. DSR Code No. 5.9.6 |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR Code No. 5.22.6 |
| 18 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.DSR Code No. 5.30 |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (6.1.2) Cement mortar 1:6 (1 cement : 6 coarse sand). DSR Code No. 6.1.2 |
| 20 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (6.4.2) Cement mortar 1:6 (1 cement : 6 coarse sand) DSR Code No. 6.4.2 |
| 21 | Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (NSI), Ref. CSI No. (6.18) SOR 23-24 |
| 22 | Same as in item 6.18 above but in super structure for 230 mm thick wall. (NSI), Ref. CSI No. (6.19) SOR 23-24 |
| 23 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). 12mm thick commercial ply conforming to IS : 1328 BWR type DSR Code No. 9.140.1 |
| 24 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. (9.51.1) With 12mm mildsteel U beading DSR Code No. 9.51.2 |
| 25 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR Code No. 10.1 |
| 26 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. DSR Code No. 10.29.2 |
| 27 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (10.30.1) 4.0 mm thick glass panes. DSR Code No. 10.30.1 |
| 28 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (10.30.2) 5.5 mm thick glass panes DSR Code No. 10.30.2 |
| 29 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.DSR Code No. 11.2 |
| 30 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (11.3.1) 40 mm thick with 20 mm nominal size stone aggregate DSR Code No. 11.3.1 |
| 31 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors 40 mm wide and 4 mm thick . DSR Code No. 11.13.1 |
| 32 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR Code No. 11.37 |
| 33 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. DSR Code No. 12.50 |
| 34 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 1.00 mm thick with zinc coating not less than 275 gm/m².. DSR Code No. 12.1.1 |
| 35 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. DSR Code No. 12.8 |
| 36 | 12 mm cement plaster of mix : (13.4.1) 1:4 (1 cement: 4 coarse sand) DSR Code No. 13.4.1 |
| 37 | 12 mm cement plaster of mix : (13.4.2) 1:6 (1 cement: 6 coarse sand) DSR Code No. 13.4.2 |
| 38 | Neat cement punning. DSR Code No. 13.18 |
| 39 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats)DSR Code No. 13.81.1 |
| 40 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre :)DSR Code No. 13.41.1 |
| 41 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) : DSR Code No. 13.46.1 |
| 42 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coats on existing cement paint surface applied @ 1.67 ltr/10 sqm. DSR Code No. 13.111.1 |
| 43 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture:DSR Code No. 13.62.1 |
| 44 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old workDSR Code No. 13.99.1 |
| 45 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. completeDSR Code No. 13.88 |
| 46 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR Code No. 13.80 |
| 47 | Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.Ordinary cement finish using ordinary cement DSR Code No. 13.19.1 |
| 48 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Door chowkhats DSR Code No. 14.2.1 |
| 49 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Window chowkhats DSR Code No. 14.2.2 |
| 50 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (15.2.1) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). DSR Code No. 15.2.1 |
| 51 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (15.7.1) In Cement mortar. DSR Code No. 15.7.4 |
| 52 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below DSR Code No. 15.12.1 |
| 53 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos Cement sheet DSR Code No. 15.28.2 |
| 54 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DSR Code No. 15.60 |
| 55 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. DSR Code No. 16.91.2 |
| 56 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps DSR Code No. 17.7.3 |
| 57 | Providing and fixing white vitreous china water closet squatting pan (Indian type) Orissa pattern W.C. pan of size 580x440 mm : DSR Code No. 17.13.2 |
| 58 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.: DSR Code No. 17.15 |
| 59 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete 10 litre capacity - White.DSR Code No. 17.18.1 |
| 60 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (17.28.1) Semi rigid pipe (17.28.1.1) 32 mm dia DSR Code No. 17.28.1.1 |
| 61 | Providing and fixing 100 mm sand cast Iron grating for gully trap. DSR Code No. 17.29 |
| 62 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR Code No. 17.31 |
| 63 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. DSR Code No. 17.33 |
| 64 | Providing and fixing CP brass toilet paper holderDSR Code No. 17.34.1 |
| 65 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (17.73.1) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms DSR Code No. 17.73.1 |
| 66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (18.7.3) 25 mm nominal dia Pipes DSR Code No. 18.7.3 |
| 67 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (18.7.5) 40 mm nominal dia Pipes DSR Code No. 18.7.5 |
| 68 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.1) 15 mm nominal dia Pipes DSR Code No. 18.8.1 |
| 69 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.2) 20 mm nominal dia Pipes DSR Code No. 18.8.2 |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.3) 25 mm nominal dia Pipes DSR Code No. 18.8.3 |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.4) 32 mm nominal dia Pipes DSR Code No. 18.8.4 |
| 72 | Providing and fixing brass bib cock of approved quality : (18.15.1) 15 mm dia nominal bore DSR Code No. 18.15.1 |
| 73 | Providing and fixing brass stop cock of approved quality : (18.16.1) 15 mm dia nominal bore DSR Code No. 18.16.1 |
| 74 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (18.18.2) 20 mm dia nominal bore DSR Code No. 18.18.2 |
| 75 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (18.18.3) 25 mm dia nominal bore DSR Code No. 18.18.3 |
| 76 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : (18.19.1) 25 mm nominal bore (18.19.1.1) Horizontal. DSR Code No. 18.19.1.1 |
| 77 | Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21.1) 30 cm length (18.21.1.1) 15 mm nominal bore DSR Code No. 18.21.1.1 |
| 78 | Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21.1) 30 cm length (18.21.1.2) 20 mm nominal bore DSR Code No. 18.21.1.2 |
| 79 | Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21.2) 45 cm length (18.21.2.1) 15 mm nominal bore DSR Code No. 18.21.2.1 |
| 80 | Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21.2) 45 cm length (18.21.2.2) 20 mm nominal bore DSR Code No. 18.21.2.2 |
| 81 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : (18.47.1) 15 mm nominal bore DSR Code No. 18.47.1 |
| 82 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : (18.47.2) 20 mm nominal bore DSR Code No. 18.47.2 |
| 83 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : (18.47.3) 25 mm nominal bore DSR Code No. 18.47.3 |
| 84 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. DSR Code No. 18.48 |
| 85 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (18.50.1) 15 mm nominal bore DSR Code No. 18.50.1 |
| 86 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. (18.53.1) 15 mm nominal bore DSR Code No. 18.53.1 |
| 87 | Applying BIRLA PUTTY or equivalent putty on previousaly bila putty smoothen surface over one cost of water base cement primer of ICI or equivalent brand for smoothining and leveling of the surface as per requirement and direction of E/I including cost of all material , labour and T&P required for proper completion of work. NSI SOR 2023-24 CSI No. 13.21 |
| 88 | Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. NSI SOR 2023-24 CSI No. 28.38 |
| 89 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light fitting including tube on surface complete in all respect. NSI Ref. UPPWD SOR 2018 1413 (CAT-AA) |
| 90 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C E&M -1.10.3 |
| 91 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. E&M-1.14.4 |
| 92 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,10kA \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. E&M 2.10.1 |
| 93 | Supplying and drawing following 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. E&M -1.17.12 |
| 94 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet. E&M -1.24.4 |
| 95 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet. E&M -1.24.5 |
| 96 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps E&M 2.12.2 |
| 97 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door. E&M -2.4.1 |
| 98 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. E&M- 1.12 |
| 99 | Supply, installation, testing and commission of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Earthing etc complete as required (DSR 19.1 (E&M 2022) |
| 100 | Hire Charges for light crane with operator & fuel (Ch 16, 16.21) (CSI No. Chapter-2 SL No. 21 (C) + 10% CP Old SOR 2023) |
| 101 | Providing and fixing of 110 mm dia PVC pipe 6 Kg/ Sq.cm for with special such as Tee, bend,socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. NSI Old SOR 2023-24 CSI NO 26.17 |