| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make: Polycab/ Finolex/ L&K) |
| 2 | Group A |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Make: Polycab/ Finolex/ L&K) |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Make: Polycab/ Finolex/ L&T) |
| 5 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 6 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 7 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 8 | 2 X6sq. mm + 1 X 6 sq. mm earth wire |
| 9 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 10 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required Make-L&K(Entice model)/LEGRAND-(Mylinc model )/ABB-(Tvisha white/IVIE model) |
| 11 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make-L&K(Entice model)/LEGRAND-(Mylinc model )/ABB-(Tvisha white/IVIE model) |
| 12 | Supplying & fixing suitable size GI/PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. (Make- L& K/ABB/LEGRAND /INDOASEAN) |
| 13 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without\ MCB/RCCB/Isolator) (Make- L&K/ABB/LEGRAND /INDOASEAN) |
| 14 | 4 way (4 + 12), Double door |
| 15 | 8 way (4 + 24), Double door |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: L&K/ABB/Legrand/Schneider) |
| 17 | Single Pole MCB |
| 18 | FP MCB 40/63 A |
| 19 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (Make: Wipro/ Philipse/CG) |
| 20 | 36 Watt |
| 21 | Brush Less Direct Current (BLDC) Fan without Remote: Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make: Atomberg/Usha/Crompton) |
| 22 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 23 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 24 | Supplying and fixing of Decorative Wall Light/Wall Lamp ,Bulb Base : B22 | Synthetic Finish Product Dimensions 7.3L x 3.9W x 9.1H Centimeters(Philips) (Make: Crompton/Wipro/Philips) |
| 25 | Supplying and fixing of 3W LED, 2 star Base ,B22 bulb. Crompton Cat No: LED3WNDFWB2SCDL (Make: Crompton/Wipro/Philips) |
| 26 | Supplying and fixing of 9 W LED bulb, 2 star Base ,B22 bulb. Crompton Cat No: LED9WNDFWB2SCDL (Make: Crompton/Wipro/Philips) |
| 27 | Supplying and fixing of 230VAC 1Ph. 250 mm exhaust Fan with sweep feature. INDOASIAN Cat No: 698502 (Make: Usha / Crompton / Orient/INDOASIAN) |
| 28 | Supplying and fixing of 230VAC 1Ph. 300 mm exhaust Fan with sweep feature. (Make: Usha / Crompton / Orient) |
| 29 | Providing,installation, fixing,Connecting and Testing of Calling Bell INDOASIAN Cat No: 800144 Make: (INDOASIAN / Crompton / Anchor) |
| 30 | Providing,installation, fixing,Connecting and Testing of Mirror Light. (Make: Wipro/ Philipse/CG) |
| 31 | Supply and Installation of Solarion Eclipse Round IP65 Gate Lamp (Plastic with B22 Holder) Crompton Cat No: GTLMP ECLRND-WH (Make: Philipse/ Wipro/Crompton) |
| 32 | Supplying, installing and testing of Three phase Kwh meter with LCD display(1P LCD Meter 5-30A ) L&T Cat No: WR301BC4D20 (Make: L&K/Schneider/Secure) |
| 33 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Make: Crompton/Wipro/Philips) |
| 34 | 50 watt |
| 35 | 100 watt |
| 36 | LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (Make: Crompton/Wipro/Philips) |
| 37 | 36 watt |
| 38 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Make: Crompton/Wipro/Philips) |
| 39 | 120 watt |
| 40 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses,connections, earthing etc. as required. (Make:L&K/Legrand/Schneider) |
| 41 | 63 A TPN |
| 42 | Supply and fixing of SMC Three Phase Meter Box |
| 43 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Make- L&K/ABB/LEGRAND /INDOASEAN/Schneider) |
| 44 | 5/6 A switch |
| 45 | 2 way 5/6 A switch |
| 46 | 15/16 A switch |
| 47 | 3 pin 5/6 A socket outlet |
| 48 | 6 pin 15/16 A socket outlet |
| 49 | Telephone socket outlet |
| 50 | TV antenna socket outlet |
| 51 | Bell push |
| 52 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess/Surface etc. as required. (Make- L&K/ABB/LEGRAND /INDOASEAN/Schneider) |
| 53 | 1 or 2 Module (75mmX75mm) |
| 54 | 3 Module (100mmX75mm) |
| 55 | 4 Module (125mmX75mm) |
| 56 | 6 Module (200mmX75mm) |
| 57 | 8 Module (125mmX125mm) |
| 58 | 12 Module (200mmX150mm |
| 59 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.(Make- L&K/ABB/LEGRAND /INDOASEAN/Schneider) |
| 60 | 1 or 2 Module |
| 61 | 3 Module |
| 62 | 4 Module |
| 63 | 6 Module |
| 64 | 8 Module |
| 65 | 12 Module |
| 66 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(Make:Anchor/LEGRAND /INDOASEAN) |
| 67 | Supplying and fixing brass batten/ angle holder including connection etc. as required. (Make:Anchor/LEGRAND /INDOASEAN) |
| 68 | Supplying and fixing PVC batten/ angle holder includingconnections etc. as required.(Make:Anchor/LEGRAND /INDOASEAN) |
| 69 | Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade,oiling including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required. |
| 70 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.(Make- L&K/ABB/LEGRAND /Schneider) |
| 71 | 32 A TP&N |
| 72 | 63 A TP&N |
| 73 | 100 A TP&N |
| 74 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make- L&K/ABB/LEGRAND /Schneider) |
| 75 | 100 A, 16 KA,TPMCCB |
| 76 | 125 A, 16 KA,TPMCCB |
| 77 | 250 A, 35 KA,TPMCCB |
| 78 | 100 A,30KA,FPMCCB |
| 79 | 125 A,36KA,FPMCCB |
| 80 | Supplying ,Installation , Testing and commissioning of 2 Module 25A Motor Starter (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 81 | Supplying ,Installation , Testing and commissioning of SP 25A Modular MCB 'C' Curve (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 82 | Supplying ,Installation , Testing and commissioning of Hotel KeyCard Switch (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 83 | Supplying ,Installation , Testing and commissioning of 25A 1 Way switch with indicator (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 84 | Supplying ,Installation , Testing and commissioning of 25A 3pin Socket (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 85 | Supplying ,Installation , Testing and commissioning of 6A 3pin Plug Top (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 86 | Supplying, Installation , Testing and commissioning of 16A 3pin Plug Top (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 87 | Supplying, installing and testing of Single phase Kwh meter with LCD display(1P LCD Meter 5-30A ) (Make: L&K/Schneider/Secure) |
| 88 | Supply and installation of 63A HRC Fuse in the existing main switch /feeder pilar (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 89 | Supply and installation of 100A HRC Fuse in the existing main switch /feeder pilar (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 90 | Supply and installation of 125A HRC Fuse in the existing main switch /feeder pilar (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 91 | Supply and installation of 160A HRC Fuse in the existing main switch /feeder pilar (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 92 | Supply and installation of 250A HRC Fuse in the existing main switch /feeder pilar (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 93 | Supply and installation of 400A HRC Fuse in the existing main switch /feeder pilar (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 94 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Make: Polycab/Gloster/KEI) |
| 95 | 4C X 10 sq.mm |
| 96 | 3.5C X 50 sq.mm |
| 97 | 3.5C X 70 sq.mm |
| 98 | 3.5C X 95 sq.mm |
| 99 | Supply and installation of Analog Time switch (With Battery Backup) (Model: 3mod DIN Daily) 3P Module, 24 hours program, Programmable every 15 min, backup of 100hrs., Current capacity 16A, with 1 change over (1 CO) (Make: L&K/ABB/LEGRAND /INDOASEAN) |
| 100 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 101 | 3½ X 50 sq. mm (35mm) |
| 102 | 3½ X 70 sq. mm (38mm) |
| 103 | 3½ X 95 sq. mm (45mm) |
| 104 | Providing services for day to day maintenance, upkeep, Breakdown maintenace,Preventive maintenance and attending complaints of complete internal and external electrical installations including manpower and all work assigned by Engineer-Incharge of all Residential building & Guest House within Institute campus, pathway and parcel area lights, panels, feeder pillar etc, on all days including Sundays and holidays etc as required in daily, and 365 Days where each shall be of 8 hour duration). |
| 105 | Electrician - 01 No |
| 106 | Khallasi/Helpher - 01 No |
| 107 | Supplying and fixing of 230V AC 1Ph, 400mm, 900 rpm wall Fan Make : Usha/ Crompton/ Orient |
| 108 | Supplying and fixing of 230VAC 1Ph. 1400mm dia Ceiling Fan (High Speed). (Make: Usha / Crompton / Orient) |
| 109 | Servicing of DBs duly opening the top cover checking the circuits, tigheting the screws, applying tape wherever required and making propoer dressing etc complete. 8 Way SPN DB |
| 110 | Servicing of DBs duly opening the top cover checking the circuits, tigheting the screws, applying tape wherever required and making propoer dressing etc complete. 12 Way SPN DB. |
| 111 | Servicing of DBs duly opening the top cover checking the circuits, tigheting the screws, applying tape wherever required and making propoer dressing etc complete. 8 Way TPN DB. |
| 112 | Servicing of DBs duly opening the top cover checking the circuits, tigheting the screws, applying tape wherever required and making propoer dressing etc complete. 12 Way TPN DB. |
| 113 | Supply and fixing of Capacitor for table /cabin/ pedestal/ceiling/exhaust fan complete with alignment of shaft and tested. |
| 114 | Servicing of LT Panels duly opening the top cover checking the circuits, tigheting the screws, applying tape wherever required and making propoer dressing etc complete. |
| 115 | Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 116 | 3 output(1output per phase) and suitable for three phase supply |
| 117 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 118 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run). |
| 119 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 120 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Please Enable Macros to View BoQ information |