| Sl. No. | Item Description |
| 1 | Taking down all existing roof treatment incl wire brushing and washing down with water cleaning loose dust etc from surfaces of RCC roof incl flashing and juntion of parapet complete all as specified and as directed by Engineer -in-Charge. |
| 2 | M&L of cutting out cracks to V-section in existing roofs or terracing , cleaning out ,wetting ,grouting with cement and sand slurry 1:3 complete all as specified and as directed by Engineer -in-Charge. |
| 3 | M&L Average 25mm thk Cement concrete type B-0, 1:2:4 (Using 12.5mm graded stone aggregate) as in levelling course/padding complete all as specified and as directed by Engineer -in-Charge. |
| 4 | M&L 10 mm thick plaster in CM (1:3) mixed with waterproofing compound on padding layer for roof treatment complete all as specified and as directed by Engineer -in-Charge. (Note :- WPC shall be measured and paid seperately on supply only.) |
| 5 | Supply only liquid waterproofing compound complete all as specified and as directed by Engineer -in-Charge. |
| 6 | M & L for applying roof treatment on top of roof with APP modified membrane (minimum 3mm thick) weight not less than 3.00 kg /sqm and reinforced with non-woven polyster reinforcement with thermal insulation with polythene finish on upper side of membrane ,laid by torch application method with overlaps 150mm on length side and100mm on the width side as per manufactures instructions over a coat of approved cold applied bituminous oil based primer @300gm/sqm and applying two coats of aluminium paint 0.20lit/sqm complete all as specified and as directed by Engineer -in-Charge. |
| 7 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed by Engineer -in-Charge. |
| 8 | Dismantling wall tiling including cement mortar bedding (but not backing), rubbish off the premises complete all as specified and as directed by Engineer -in-Charge. |
| 9 | M&L 16-18 mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer -in-Charge. |
| 10 | Moulding to Granite(single or double) slab including rounding off edges for 20 mm thick slabs including grinding and polishing complete all as specified and as directed by Engineer -in-Charge. |
| 11 | Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick CM 1:4 bedding layer laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engineer -in-Charge. |
| 12 | M&L for Machine cut kota stone slab 20-25 mm thick in riser of step ,skirting, dado,vertical partition and pillar laid over cement screed etc, piece machine polished laid over and jointed in cement slurry and pointed in grey cement and pigment to match the colour of slab,10mm thick rendering as in backing coat for skirting/dado in CM (1:3) with on wall surfaces complete all as specified and as directed by Engineer -in-Charge. |
| 13 | S&F Coloured Vitrified tiles 10 mm thick (square / rectangular) polished area of each tiles n exc 0.36 sqm in floors & skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match in light shade including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer -in-Charge. |
| 14 | M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding .06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match , over 15mm thick screed bed in CM 1:6 all as specified and as directed by Engineer -in-Charge. |
| 15 | M&L Glazed ceramic coloured designer tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 0ver 10mm thick plaster in cement mortar (1:3) complete all as specified and as directed by Engineer -in-Charge. |
| 16 | Demolition of brick work/stone masonry built in cement mortar of any description all as specified and as directed by Engineer -in-Charge. |
| 17 | M&L brickwork with old size flyash bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed by Engineer -in-Charge. |
| 18 | Taking down Doors chowkat or frame n exc 1.5 Sqm but with shutters (without taking off shutters from the frames) and removing out of site complete all as specified and as directed by Engineer -in-Charge. |
| 19 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm complete all as specified and as directed by Engineer -in-Charge. |
| 20 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed by Engineer -in-Charge. |
| 21 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer -in-Charge. |
| 22 | S&F Pressed steel frames for doors size 125 mm X60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engineer -in-Charge. |
| 23 | M&L PCC type B0, 1:2:4 (12.5 mm graded aggregate) filling in door and frames, any size, single or double rebated, including arrangements complete all as specified and as directed by Engineer -in-Charge. |
| 24 | M&L applying one coat of black bituminus paint on Surfaces of any description wood,steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth complete all as specified and as directed by Engineer -in-Charge. |
| 25 | S&F factory made 35mm thick 2nd class hard wood glzed & skeleton door shutters,open rebated and prepared to recieve gauge etc(without sash bars) edgs of framing plain, chamfered or etc,size of members of shutters as specified in SSR Pt-I, Sec-8 Clause 8.20 (a) without sash bar etc complete all as specified and as directed by Engineer -in-Charge. |
| 26 | S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (any number of Panel) with lock rail and panel of 12 mm thick veneered particle board with commercial veneering on both faces,. The size of rail and styles as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer -in-Charge. |
| 27 | S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staples or with second class hard wood beadings in any type of door as per complete all as specified and as directed by Engineer -in-Charge. |
| 28 | S&F 300mm , ordinary rat tail rod pattern springs including roller and roller plate fixed etc with screw/ welding etc as required at site complete all as specified and as directed by Engineer -in-Charge. |
| 29 | M&L preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed all as specified and as directed by Engineer -in-Charge. |
| 30 | M&L preparation of old treated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed by Engineer -in-Charge. |
| 31 | S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed 150mm complete all as specified and as directed by Engineer -in-Charge. |
| 32 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 250 mm long complete all as specified and as directed by Engineer -in-Charge. |
| 33 | S&F in Aluminium handles, cast type, anodised 150mm long complete all as specified and directed all as specified and as directed by Engineer -in-Charge. |
| 34 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, 140 mm with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engineer -in-Charge. |
| 35 | S & F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed by Engineer -in-Charge. |
| 36 | S&F in repairs SS Curtain Rod Decorative pattern as approved and complete all as specified and as directed by Engineer -in-Charge. |
| 37 | S&F in repairs SS Curtain Rod Bracket decorative type complete all as specified and as directed by Engineer -in-Charge. |
| 38 | Dismantling exc 500 and n exc 1000 ltr water tank removing to store complete all as specified and as directed by Engineer -in-Charge. |
| 39 | S&F 1000ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with 20mm ball/float valve complete all as specified and as directed by Engineer -in-Charge. |
| 40 | Taking down steel tubing and connections including cleaning for refixing or removal to store of 15 mm dia complete all as specified and as directed by Engineer -in-Charge. |
| 41 | Taking down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by Engineer -in-Charge. |
| 42 | Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass cpvc fittings and cutting grooves, filled with CM1:6 complete all as specified and as directed by Engineer -in-Charge. |
| 43 | Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fittings and cutting grooves, filled with CM1:6 complete all as specified and as directed by Engineer -in-Charge. |
| 44 | Demolition of cement concrete (un-reinforced) in any position not otherwise specifically provided complete all as specified and as directed by Engineer -in-Charge. |
| 45 | M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection all as specified and as directed by Engineer -in-Charge. |
| 46 | Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade A complete all as specified and as directed by Engineer -in-Charge. |
| 47 | Taking down cement plaster on brick/stone or concrete surfaces including racking out joints, hacking for key,scrubbing down with water to receive plaster including necessary all scaffolding complete all as specified and as directed by Engineer -in-Charge. |
| 48 | M&L for rendering 10mm thick on fair faces of brick/stone work or concrete surfaces in CM 1:6 finishing the surface even and even smooth without using extra cement complete all as specified and as directed by Engineer -in-Charge. |
| 49 | M&L 15 mm thick rendering in in two layers 5mm thick inCM 1:4,over 10mm thick cement plaster in CM 1:6 on fair face of brick work/Stone or concrete surface to be finished even and smooth without using extra cement Including WPC compound 3% by weight of cement.(Note :a) Intergial WPC Compound shall be used in second layer,b) Intergial WPC shall be paid seperately on supply only complete all as specified and as directed by Engineer -in-Charge. |
| 50 | M&L for rendering 5 mm thick in CM 1:3 on ceiling to be finished complete all as specified and as directed by Engineer -in-Charge. |
| 51 | Preparation of newly plastered surfaces of wall incl sweeping clean with brush to remove loose dust, sand, etc and applying two coats of heavy duty waterproofing coat (Dr Fixit Wounderproof-1 or equivalent) by mixing water @ 25-30% to make slurry coating and allow 4 to 6 hrs time for drying up of first coat before application of second coat in perpendicular direction of first coat and further left to dry for 4 hrs complete all as specified and as directed by Engineer -in-Charge. |
| 52 | M&L preparation of newly plastered surfaces of walls for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed by Engineer -in-Charge. |
| 53 | M&L for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper including one coat of suiatable primer including 1mm thick wall care putty on wall etc complete all as specified and as directed by Engineer -in-Charge. |
| 54 | M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer -in-Charge. |
| 55 | Material and labour for complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc, the area of application should be cleaned thoroughly, remove all dirt, dust and uneven elements from the surface by washing and scraping and all the unevenness in the surface should be corrected by filling the exterior wallcare putty, surface should be sanded down with fine grade sand paper for smoothness and applying one coat of exterior primer and 02 coats of Exterior Weather Coat Emulsion Paint of white or tinted shade(any colour) as per manufacturer instruction complete all as specified and as directed by Engineer -in-Charge. |
| 56 | Complete Removal of existing treatment on ceiling and applying two coats of white wash a complete all as specified and as directed by Engineer -in-Charge. |
| 57 | Complete Removal of existing treatment on wall and applying two coats of oil bond distemper including one coat of suiatable primer and 1 mm putty complete all as specified and as directed by Engineer -in-Charge. |
| 58 | S&F in repair Vitreous china wash basin, white , flat back , size 550 x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets fixed in repairs complete all as specified and as directed by Engineer -in-Charge. |
| 59 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors/wall complete all as specified and as directed by Engineer -in-Charge. |
| 60 | S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors/wall complete all as specified and as directed by Engineer -in-Charge. |
| 61 | S&F 110mm PVC (SWR) single T equal or unequal complete all as specified and as directed by Engineer -in-Charge. |
| 62 | S&F in repairs PVC(SWR) bend any radius, 110 mm dia complete all as specified and as directed by Engineer -in-Charge. |
| 63 | S&F in repairs PVC(SWR) bend any radius, 75 mm dia complete all as specified and as directed by Engineer -in-Charge. |
| 64 | S&F in repairs PVC(SWR) Tee any radius, 75 mm dia complete all as specified and as directed by Engineer -in-Charge. |
| 65 | S&F in repairs 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent complete all as specified and as directed by Engineer -in-Charge. |
| 66 | S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and as directed by Engineer -in-Charge. |
| 67 | S&F fancy type CP bib taps, 15 mm bore with crutch or , screwed down, fixed as in repairs complete all as specified and as directed by Engineer -in-Charge. |
| 68 | S&F in repairs Pillar taps 15 mm dia, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe/cpvc pipe and fixed complete all as specified and as directed by Engineer -in-Charge. |
| 69 | S&F in repairs angle cock chromium plated with long shank and cup (concealed type) 15 mm dia screwed down, high pressure with crutch or butter fly handle, screwed both ends, fixed as in repairs. complete all as specified and as directed by Engineer -in-Charge. |
| 70 | S&F in repairs Brass CP wall Mixer for mixing hot & Cold water screwed down for iron pipe/CPVC pipe and fixed.make and joint with adhesive , taflon tape complete all as specified and as directed by Engineer -in-Charge. |
| 71 | S&F in repairs corner glass shelf 300mm and as selected,complete all as specified and as directed by Engineer -in-Charge. |
| 72 | S&F in repairs glass shelf 300mm as selected,complete all as specified and as directed by Engineer -in-Charge. |
| 73 | S&F in repairs Vitreous China wash down water closet pan (pedestal pattern) with 'P' or 'S' trap, white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed by Engineer -in-Charge. |
| 74 | S & F plastic water closet seat for pedestal pan,black(coloured) closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device and complete all as specified and as directed by Engineer -in-Charge. |
| 75 | S&F Stop cock two way 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed all ends for iron pipe or for unions and taking down old stop cock complete all as specified and as directed by Engineer -in-Charge.. |
| 76 | S&F CP Health Faucet with 1.50mtr tube & Hook any description including flexible attachment complete all as specified and as directed by Engineer -in-Charge. |
| 77 | S&F Waste fittings,32mm brass , chromium plated for glazed ware sinks , basins , etc. with long screwed shanks and fly -nuts , flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer -in-Charge. |
| 78 | S&F in repairs 32 mm bore PVC waste pipe with fittings of approved make suitable for WHB, Urinals etc complete all as specified and as directed by Engineer -in-Charge. |
| 79 | S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed by Engineer -in-Charge. |
| 80 | S&F 15 mm bore Chromium plated shower roses with or without swivel joints, any size, including fixing to steel/cpvc pipe or union in repairs complete all as specified and as directed by Engineer -in-Charge. |
| 81 | S&F Tubular towel rail, brass CP 20mm dia, D type, 60cm long between flanges in repairs complete all as specified and as directed by Engineer -in-Charge. |
| 82 | S&F in repairs 600 mm x 450 mm bevelled edge mirror of selected quality glass,mounted on 6mm thick. AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cap washers complete all as specified and as directed by Engineer -in-Charge. |
| 83 | S/F in repairs PVC valveless syphonic action type ,flushing cistern Low level white,with,with inlet ball valve ,float and handle 10 Ltr capacity including brackets complete all as specified and as directed by Engineer -in-Charge. |
| 84 | Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying epoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and as directed by Engineer -in-Charge. |
| 85 | Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and as directed by Engineer -in-Charge. |
| 86 | Removing excavated materials to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m from starting point all as specified and as directed by Engineer -in-Charge. |
| 87 | Demolition and breaking up sewage drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar (Internal dia of pipe in 200 mm) complete all as specified and as directed by the Engineer-in-Charge. |
| 88 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and as directed by Engineer -in-Charge. |
| 89 | S&F DWCPE (SN8) pipes, nominal dia 200 mm laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer instructions complete all as specified and as directed by Engr-in-Charge |
| 90 | M&L for cement concrete bedding against the sides of pipes after they are laid to 200 mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and as directed by Engineer -in-Charge.NOTE :- Pipe shall be measured and paid separately).as in repairs. |
| 91 | Demolition for reinforcement cement concrete complete all as specified and as directed by Engineer -in-Charge. |
| 92 | M&L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate in cover slabs including necessary form work etc for manholes covers set in CM 1:4 complete all as specified and as directed by Engineer -in-Charge. (reinforcement measured seperately) |
| 93 | M&L for TMT bars 6 to 8mm dia and over cut to length bent to shape required including bending and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified and as directed by Engineer -in-Charge. |
| 94 | M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer -in-Charge. |
| 95 | M&L 75mm thick PCC type C-2, 1:3:6 (40mm graded stone aggt) as in path, hard standing, parking floors, etc., complete all as specified and as directed by Engineer -in-Charge. |
| 96 | Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed by Engineer -in-Charge. |
| 97 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),including making joints with or without grooves(thickness of joints except at sharp curve shall not to more than 5 mm ), including making drainage opening wherever required complete all as specified and as directed by Engineer -in-Charge. |
| 98 | M&L PCC type B1, 1:2:4 (20 mm graded aggregate) filling in sides of kerb stone complete all as specified and as directed by Engineer -in-Charge. |
| 99 | S&F coloured aluminium anodised sliding window of 3 track, frame of section 92mm X 32mm X 1.47 mm or appropriate equivalent section and shutters of section 18 mm X 44 mmX 1.35 mm or appropriate equivalent section ,aluminium sections weighting 0.55 Kg/m, fixed with 4.80/5mm thick tinted glass with rubber gasket, handles, locking arrangement and SS wire mesh,aluminium powder coated any colour (powder coating not less than 50 micron) incl making good jambs, cills etc including taking down old iron window complete all as specified and directed by the Engr-in-Charge.Note : rate shall include all glazing/SS wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc all as specified and as directed by Engineer -in-Charge. |
| 100 | S&F in powder coated aluminium fixed louvered ventilator, frame of section 63.5mm X 38.1mm X 1.01 mm or appropriate equivalent section with 4 mm thick figured/frosted sheet glass with rubber gasket,Aluminium wire mesh, handles, locking arrangement etc incl making good jambs, cills etc and including taking down old iron ventilator complete all as specified and as directed by Engineer -in-Charge. |
| 101 | S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer -in-Charge. |
| 102 | Dismantling wrought iron or mild steel work of any description complete all as specified and as directed by Engineer -in-Charge. |
| 103 | M&L for preparation of new steel surfaces exc 10 cm in width or girth and applying 2 coats synthetic enamel paint over a coat of red primer all as specified and as directed by Engineer -in-Charge. |
| 104 | Dismantling boardings, any description, fixed in any position with screws complete all as specified and as directed by Engineer -in-Charge. |
| 105 | M & L 18/19mm thick Pre-laminated particle board, interior grade, prelamination one side with decorative choice lamination & other side balancing white lamination, fixed with nails as in cupboards / cabinets incl locking arrangement all as specified and as directed by Engineer -in-Charge. |
| 106 | S&F 18/19 mm wide 6 mm thick lipping on veneered particle/pre-laminated particle as in cupboard shutter and shelves complete all as specified and as directed by Engineer -in-Charge. |
| 107 | S&F in repairs 2nd class hardwood plain fillet square rectangular in section wrought sawn secured with screws exc 13 & n exc 25 sqcm in section complete all as specified and as directed by Engineer-In-Charge.. |
| 108 | S&F75 mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed,tupe C21 all as specified and as directed by Engineer -in-Charge. |
| 109 | S&F Extruded aluminium alloy handles 100mm long, fabricated type, anodised. Complete all as specified and as directed by Engineer -in-Charge. |
| 110 | S&F Aluminium anodised 75mm hasp and staple ,safety type with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed by Engineer -in-Charge. |
| 111 | S&F in repairs stainless steel sink with draining board made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, including bedding in cement mortar to dwarf walls , or cast iron and cantilever brackets, connecting union to waste pipe upto sqm each, overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete including removing existing sink complete all as specified and as directed by Engineer -in-Charge. |
| 112 | M&L for 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing compound @ 3% of cement in bottom of sunken floors complete all as specified and as directed by Engineer -in-Charge. |
| 113 | M&L Cleaning vertical and horizontal surfaces of sunken slab using wire brushing followed by sanding with emery paper for loose materials/dust and applying two coats of epoxy resin component (Dr. Fixit DAMPGUARD or equivalent) solution/mix using nylon brush pouring Base part in appropriate container followed by the Hardner part and mix thoroughly to attain homogeneous smooth paste and dilute the mixed compound with water in ratio 1 part Base: 1 part Hardner: 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/final coat) incl curing treated surface for 24 hrs complete incl applying evenly a coat of blown bitumen @ 1.5kg/sqm over entire treated surfaces incl spout holesbefore filling lean concrete complete all as specified and as directed by Engineer -in-Charge. |
| 114 | M&L 15mm thick rendering in cement plaster 1:3 with WPC on bottom and side walls of sunken floor incl finished even and smooth w/o using extra cement complete all as specified and as directed by Engineer -in-Charge. |
| 115 | M&L filling PCC type E-2 1:5:10 (40 mm graded stone aggr) as in sunken floor after applying appropriate treatment to side walls complete all as specified and as directed by Engineer -in-Charge. |
| 116 | M & L filling dry and clean sand in trenches for cable 8 cm deep below and 15 cm above for cable cushioning complete all as specified and directed by Engr in Charge |
| 117 | Supplying and laying un-reinforced precast concrete cable cover, LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-In-charge. |
| 118 | M & L for XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 25 sqmm 4 core size laid in trenches under floor/roads/hard standing along poles etc complete all as specified and directed by Engr in Charge. |
| 119 | Supply and fixing GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking down old unserviceable GI pipe complete all as specified and directed by Engr-in-Charge . |
| 120 | Taking up/down GI tubing and connections 20mm size of pipes including all fittings complete all as specified and as directed by Engineer -in-Charge. |
| 121 | Taking up/down GI tubing and connections 25mm size of pipes including all fittings complete all as specified and as directed by Engineer -in-Charge. |
| 122 | S&F tube GI medium grade 20mm dia with all fittings laid in trenches complete all as specified and as directed by Engineer -in-Charge. |
| 123 | S&F tube GI medium grade 25mm dia with all fittings laid in trenches complete all as specified and as directed by Engineer -in-Charge. |
| 124 | S&F gun metal valvs with iron wheel head ,screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and as directed by Engineer -in-Charge. |
| 125 | Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr in Charge |
| 126 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and as directed by Engineer -in-Charge. |
| 127 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed by Engineer -in-Charge. |
| 128 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed by Engineer -in-Charge. |
| 129 | Taking down ceiling fan/ Exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and as directed by Engineer -in-Charge. |
| 130 | M & L for Point wiring for One light point controlled by one, one way switch 5 Amps using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and as directed by Engineer -in-Charge. |
| 131 | Description all as per item No 130 here in before but using One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator complete all as specified and as directed by Engineer -in-Charge. |
| 132 | Description all as per item No 130 here in before but using One light point controlled by one, two way switch 5 Amps complete all as specified and as directed by Engineer -in-Charge. |
| 133 | Description all as per item No 130 here in before but using One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed by Engineer -in-Charge. |
| 134 | Description all as per item No 130 here in before but using One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad complete all as specified and as directed by Engineer -in-Charge. |
| 135 | Description all as per item No 130 here in before but using One bell point controlled by one, bell switch 5 Amps complete all as specified and as directed by Engineer -in-Charge. |
| 136 | Description all as per item No 130 here in before but using 4.0 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 4.0 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (power point) complete all as specified and as directed by Engineer -in-Charge. |
| 137 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and,cutting chases for concealed water,tubing or concealed conduit wiring,,etc., and making good, cutting not,exc 10 cm girth ®(stone massonary) complete all as specified and as directed by Engineer -in-Charge. |
| 138 | S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and as directed by Engineer -in-Charge. |
| 139 | S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified all as specified and as directed by Engineer -in-Charge. |
| 140 | S & F for modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified and as directed by Engineer -in-Charge. |
| 141 | S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified all as specified and as directed by Engineer -in-Charge. |
| 142 | S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified all as specified and as directed by Engineer -in-Charge. |
| 143 | S & F for modular step type fan regulator (BLDC) 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed by Engineer -in-Charge. |
| 144 | S & F for Bell push modular 6 Amps single module complete all as specified and as directed by Engineer -in-Charge. |
| 145 | S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed all as specified and as directed by Engineer -in-Charge. |
| 146 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed by Engineer -in-Charge. |
| 147 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed by Engineer -in-Charge. |
| 148 | S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engineer -in-Charge. |
| 149 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engineer -in-Charge. |
| 150 | S & F for MCB Tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer -in-Charge. |
| 151 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer -in-Charge. |
| 152 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer -in-Charge. |
| 153 | S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC) with out remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and as directed by Engineer -in-Charge. |
| 154 | S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed by Engineer -in-Charge. |
| 155 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed by Engineer -in-Charge. Make :- Make Bajaj Cat part No BCLAB 20W WH LED P, Wipro Cat part No LL20-281-XXX065-ALI or its equvalent in Philips, Havells complete all as specified and as directed by Engineer -in-Charge. |
| 156 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make :- Bajaj Cat part No ENXT P 24L WH CR PC SD (Edge plus series) or its equvalent in Philips, Wipro complete all as specified and as directed by Engineer -in-Charge. |
| 157 | S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as specified and as directed by Engineer -in-Charge. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted). |
| 158 | Taking down of solar water heater o up to 200 ltr from roof of bldg with all acessories complete including fabrication work , after roof treatment refixing the solar water heater 200 ltr on the roof of bldg with fabrication work complete all as specified and as directed by Engineer -in-Charge. |
| 159 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and as directed by Engineer -in-Charge. |
| 160 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted complete all as specified and as directed by Engineer -in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |