| 1 | M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (if required), complete all as per specified and as directed by Engineer-in-Charge. |
| 2 | Ditto as per Item No. 01, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge. |
| 3 | Ditto as per Item No. 01, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge. |
| 4 | Ditto as per Item No. 01, but for One 3/5 pin socket outlet, 15 Amps, independent board, with wires 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge. |
| 5 | Ditto as per item No. 01, but for one light point controlled by two way switch with 1.5 sqmm copper wire |
| 6 | S&F in repair switch Piano type two way 5 amp 230 volts complete all as specified and as directed. |
| 7 | S&F in repair switch bell push flush type 5 amp 230 volts complete all as specified and as directed. |
| 8 | S&F in repair Switch Piano flush type single pole one way 5 amp 230 v complete all as specified and directed. |
| 9 | S&F in repair socket outlet 2 in 1 , 5 pin, 5 amp complete all as specified and directed. |
| 10 | S&F in repair Switch Piano flush type single pole one way 15 amp 230 v complete all as specified and directed. |
| 11 | S&F in repair socket outlet 2 in 1 , 6 pin,5 and 15 amp complete all as specified and directed. |
| 12 | S&F in repair ceiling rose surface type Bakelite 65x50 mm three terminals complete all as specified and directed. |
| 13 | S&F in repair stepped type electronic fan regulator flushType complete all as specified and directed. |
| 14 | S&F in repair lamp holder , PVC /Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-charge. |
| 15 | S&F in repair box type Switch socket combination 2 in 1, 3/5 pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 16 | S&F in repair box type Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 17 | M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and including PVC concealed conduit and conduit accessories accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (as/if requred), complete all as per specified and as directed by Engineer-in-Charge. |
| 18 | Ditto as per Item No. 17, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge. |
| 19 | Ditto as per Item No. 17, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge. |
| 20 | Ditto as per Item No. 17, but for One 3/5 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge. |
| 21 | S&F in repair Modular switch , one way, 10 amps, 1 module 230 v complete all as specified and directed at site. |
| 22 | S&F in repair Modular switch , one way, 16 amps, 1 module 230 v complete all as specified and directed at site. |
| 23 | S&F in repair socket outlet,modular type ,multipurpose,multipin, 6/10 amps,1 module, 230 v complete as per direction by engr in charge |
| 24 | S&F in repair socket outlet,modular type ,multipurpose,multipin, 6/10/16/20 amps ,two module, 230 v complete as per direction by engr in charge |
| 25 | S&F in repair modular type fan regulator,two module, 230 v complete all as specified and directed at site. |
| 26 | S&F in repair modular bell push 6 Amps 230 volts complete all as specified and as directed. |
| 27 | S&F in repair call bell Ding-Dong AC, 230 volts single pole complete all as specified and as directed. |
| 28 | S&F in-repair of modular cover plate (white) with frame, 1-module, inclding back ms plate complete all as specified and as directed by Engineer-in-charge. |
| 29 | S&F in-repair of modular cover plate (white) with frame, 2-module, inclding back ms plate complete all as specified and as directed by Engineer-in-charge. |
| 30 | S&F in-repair of modular cover plate (white) with frame, 3-module, inclding back ms plate complete all as specified and as directed by Engineer-in-charge. |
| 31 | S&F in-repair of modular cover plate (white) with frame, 4-module, inclding back ms plate complete all as specified and as directed by Engineer-in-charge. |
| 32 | S&F in-repair of modular cover plate (white) with frame, 6-module, inclding back ms plate complete all as specified and as directed by Engineer-in-charge. |
| 33 | S&F in-repair of modular cover plate (white) with frame, 8-module, inclding back ms plate complete all as specified and as directed by Engineer-in-charge. |
| 34 | S&F in-repair of modular cover plate (white) with frame, 12-module, inclding back ms plate complete all as specified and as directed by Engineer-in-charge. |
| 35 | S&F in repair surface and wall mounted LED batten fitting energy efficient fittings 20 watt complete inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100 Volts grade all as specified and directed. |
| 36 | S & F in repair surface and wall mounted LED batten fitting energy efficient fittings 10 watt complete inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100 Volts grade all as specified and directed. |
| 37 | Supply and fix LED warm/cool Lamps 10 w B 22 base 3 star rating suitable for batten holder complete all as specified and as directed by Engineer-in-charge. |
| 38 | S&F Blanking Plates for covering of MCCB DB open space complete all as specified and directed. |
| 39 | S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 40 | S&F in repair for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area & one run of 6.0 sqmm as earth continuity conductor drawn through & including PVC casing-caping medium grade complete all as specified and as directed. |
| 41 | Ditto as per ser item No 40, but 2x 4 sqmm for Phase and Neutral and 1x 4 sqmm for earth wire |
| 42 | S&F in repair MCB DB TPN 4 way with metal door suitable for Provision of incomer MCB and outgoing MCB's complete all as specified and as directed. |
| 43 | S&F in repair MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 44 | S&F in repair MCB DB SPN 4 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. |
| 45 | S&F in repair MCB SPN 240 volt 32 Amps 'C' Series 10 KA complete all as specified and directed. |
| 46 | S&F in repair MCB SPN 240 volt 40 Amps 'C' Series 10 KA complete all as specified and directed. |
| 47 | S&F in repair MCB FP 240 volt 63 Amps 'C' Series 10 KA complete all as specified and directed. |
| 48 | S&F in repair MCB SP 240 volt 6 to 32 Amps 'C' Series 10 KA complete all as specified and directed. |
| 49 | Supply and fix in repair factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket of 20 amps capacity complete all as specified and directed. |
| 50 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.Note : Old unsv ceiling fan will be deposited to MES store yard |
| 51 | Supply and fix exhaust fan, steel body AC Single Phase, 230 V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed.Note : making of suitable size hole will be considered in quoated rate. Old unsv exhaust fan will be deposited to MES store yard. |
| 52 | S&F in repair Capacitor 2.5 MFD epoxy filled type copper wound complete all as specified and directed. |
| 53 | S&F in repair Capacitor 3.15 MFD epoxy filled type copper wound complete all as specified and directed. |
| 54 | S&F in-repair of surface mounted PVC box of size 100 mm x 100 mm and 50 mm deep, complete all as specified and as directed by Engineer-in-charge. |
| 55 | S&F in-repair of surface mounted PVC box of size 100 mm x 175 mm and 50 mm deep, complete all as specified and as directed by Engineer-in-charge. |
| 56 | S&F in-repair of surface mounted PVC box of size 200 mm x 150 mm and 50 mm deep, complete all as specified and as directed by Engineer-in-charge. |
| 57 | Supply and fix in repair electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 ltr,BEE 5 star rated complete with all accessories such as safety valve,thermostate,NRV,connection pipe,wall fastner etc complete all as specified and directed.Note : Old unsv ceiling fan will be deposited to MES store yard Please Enable Macros to View BoQ information |
| 58 | Supply and fix in repair electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 ltr,BEE 5 star rated complete with all accessories such as safety valve,thermostate,NRV,connection pipe,wall fastner etc complete all as specified and directed.Note : Old unsv ceiling fan will be deposited to MES store yard Please Enable Macros to View BoQ information |