| 1 | Schedule-A |
| 2 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge. |
| 3 | M&L for 75mm thick plain cement concrete type B2 1:2:4 (40 mm graded stone aggregate) laid in alternate pannel for floor, path and hardstanding all as specified and directed by Engr-in-Charge. |
| 4 | M&L for 25 mm thick wearproof topping using metallic floor hardner as per manufacturer's instructions, as specified (incorporating an approved metalic floor hardner), laid on concrete floors and pavings and path, and finished even and smooth (except metallic hardner) all as specified and directed by Engr-in-Charge. (Note Metallic hardner and glass strips are measured and paid seperately). |
| 5 | Supply only Metallic floor hardener complete all as specified and as directed by Engr-in-Charge. |
| 6 | Supply only 22 mm wide and 3 mm thick glass dividing strips as laid in floor all as specified and directed by Engr-in-Charge. |
| 7 | Dismantling of brick work built in cement mortar including all quions, arches, pillars, etc. completed all as specified and as directed |
| 8 | M&L for Brick work with sub class B bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 completed all as specified and as directed |
| 9 | All as item No 7 here in before but using old serviceable bricks retrieved from dismantling. |
| 10 | Taking down cement plaster, any description on brick walls or on concrete surfaces including racking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. |
| 11 | M&L for rendering 15 mm thick on fare faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement all as specified |
| 12 | M&L for rendering 10 mm thick on stone surfaces or surface other than fair face of brick work or other side of lathing in cement mortar 1:6 finished even and smooth without using extra cement all as specified |
| 13 | M&L for rendering 5mm thick in cement motar 1:3 on ceiling like chhaja, roof projection facia etc on concrete surfaces, finished fair & even without using extra cement completed all as specified and as directed |
| 14 | M&L for preparing of new plastered surface of walls, applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489 : 2004 Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied & .90 ltre/10 Sqm as directed by Engr-in-Charge (Note- work will be strictly executed by mechanised means/tools as required for smart periodical services) |
| 15 | Preparing Newly Plastered Surfaces of WALLS and applying TWO COATS of DISTEMPER OIL EMULSION (OIL BOUND WASHABLE DISTEMPER) over a Coat of CHALK WHITING, complete all as specified and as directed. by Engineer-in-Charge. |
| 16 | M&L for prepraing new surface of plaster on ceiling and applying two coat of white wash complete all as specified and directed by Engr-in-Charge |
| 17 | M&L complete removal of existing treatment plastered surfaces of walls and corneces and applying two coat of exterior emulsion paint over one coat of priming coat in camouflage pattern all as specified and directed by Engneer-in-charge. |
| 18 | M&L for prepraing old surface of plaster, washing rubbing down and stopping of painted surfaces on wall and applying two coat of cement base paint complete all as specified and directed by Engr-in-Charge |
| 19 | M&L preparing old distempered surfaces of wall by complete removal of existing treatment and applying two coat of oil emulsion distemper over Birla / JK wall putty 3mm thick complete all as specified and as directed. |
| 20 | M&L for prepraing old surface of plaster, washing rubbing down and stopping of painted surfaces on ceiling and applying two coat of white wash complete all as specified and directed by Engr-in-Charge |
| 21 | Taking down mild steel door shutter exc 4 Sqm n exc 15 Sqm each taking down exc hole fast and fixed with new hold fast in PCC 1:1/2:3 with hardener and wellding with column reinforcement and other and two door shutter including all necessary scaffolding and mechanicla arangement all as directed by Engr-in- Charge. |
| 22 | S&F 1.25mm mild steel, plain black sheet hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; waters tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required and directed. |
| 23 | Taking down Chowkhats or frames not exc. 1.5 sqm each but with shutters (without taking off shutters from the frames) complete all as specified and as directed |
| 24 | Taking down Chowkhats or frames exc. 1.5 sqm but not exc 4.0 Sqm each but with shutters (without taking off shutters from the frames) complete all as specified and as directed |
| 25 | S&F anodised aluminium frame powder coated (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified |
| 26 | S&F powder coated anodised aluminium window and ventilator shutters on any colour (Thickness of powder coating not less than 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified |
| 27 | M&L for 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each pane |
| 28 | S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples |
| 29 | M&L for 5 mm thick aluminium composite sheet, exterior grade fixed betdween aluminium section with and including snap fitting aluminium clips of polyster powder coated alongwith rubber fgasket, complete all as specified and directed by Engr-in-charge |
| 30 | M&L, for 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on both side with decorative choice laminations fixed between aluminium section with and including snap fitting aluminium clips of polyester powder coated along with the glass with rubber gasket, complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F 30mm thick factory made flush door shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides all as specified and directed by Engr-in-Charge. |
| 32 | S&F butt hinges medium weight MS cold rolled 100mm long complete all as specified and as directed by Engr-in-Charge. |
| 33 | S&F 150 mm long aluminium anodised barrel tower bolt to extruded section and fixed complete all as specified and as directed by Engr-in-Charge. |
| 34 | S&F 150 mm aluminium handle, cast type anodised complete all as specified and as directed by Engr-in-Charge. |
| 35 | S&F 250 mm long aluminum alloy, anodised, sliding door bolt long whith hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixidng bolts and siliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed by Engr-in-Charge. |
| 36 | M&L for prepration of new or previously untreated wood surfaces, of any description, not otherwise described, over 10 cm width or girth applying a coat of pink primer over two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 37 | M&L for prepration of old wood surfaces, of any description, not otherwise described, over 10 cm width or girth applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L Preparation new or previously untreated steel surface of any description, over 10 cm in width or girth, one coat of red oxide zinc chrome primer over applying two coat synthetic enamel (ordinary tint) paint all as specified and directed by Engr-in-charge. |
| 39 | M&L Preparation old painted steel surface of any description, over 10 cm in width or girth, applying two coat synthetic enamel (ordinary tint) paint all as specified and directed by Engr-in-charge. |
| 40 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel/allmn frame glazed with putty or fixed with wooden /almn beads etc.completed all as specified and as directed |
| 41 | Dismantling of asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by Engr-in-Charge. |
| 42 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed by Engr-in-Charge. |
| 43 | M&L 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with ‘L’ or ‘J’ type cranked hook bolts all as specified and directed by Engr-in-Charge. |
| 44 | M&L asbestos cement 6mm thick in two pieces adjustable plain ridge fixed with 'L' or 'J' type hook bolts complete all as specified and as directed by Engr-in-Charge. |
| 45 | S&F 0.5 mm thick pre coated thick galvalume aluminium zink coated GI based corrougated steel sheeting of any colour having tansile strength of 550 MPA as in roof covering/glading to wall fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. |
| 46 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, crample joints and similar works etc fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. |
| 47 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specidfied and directed by Engr-in-Charge. |
| 48 | S&F 8 to 10mm thick densified reqular edged eco friendly light weight calcium silicate false ceiling tiles size 600x600mm including main 'T' runner of size 24x38mm made from 0.33 mm sheet hot deep galvanized steel section making good existing frame without disterbing the other false ceiling with all as directed by Engr-in-Charge. |
| 49 | S&F in repair 8 to 10mm thick densifed regular edged eco friendly light weight calcium silicate false ceiling tiles size 600x600mm without disterbing the other false ceiling and making good existing frame with all as specified and directed by Engr-in-Charge. |
| 50 | M&L for plain cement concrete 75 mm thick type C2, 1:3:6 using (40 mm graded aggregate ) as in plinth protection path finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.. |
| 51 | S&F in repair 110 mm bore PVC ( SWR) single socketed in any length with rubber ring joints fixed to walls/floor complete as specified including flat iron clamps 25x3mm complete all as specified including taking out old damaged PVC rain water pipes complete all as specified and as directed by Engr-in-Charge. |
| 52 | All as per item No.50 but for 75 mm bore. |
| 53 | S&F PVC (SWR) bends of any radius for 110 mm bore complete all as specified and directed. |
| 54 | S&F PVC (SWR) bends of any radius for 75 mm bore complete all as specified and directed. |
| 55 | Taking down steel rolling shutter of size exc 3.00 Sqm and n exc 12 sqm and refixing the same after greasing of MS spring and side guide making and functional after overhaling complete all as specified and as directed by Engr-in-Charge. (Note : Supply of material to be measured seperately) |
| 56 | Supply only MS pipe medium grade of dia upto 40 mm including cutting and fixing, drilling, welding for rolling shutter all as directed |
| 57 | Supply only spring of high carbon spring 30mm dia drilling, welding for rolling shutter all as directed. |
| 58 | Supply only steel rolling shutter strips made out of 1.25mm MS sheet including and reavting including one coat of primer and two coat of synthetic enamail paint all as directed Engr-in-Charge. |
| 59 | Supply only safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed by Engr-in-Charge. |
| 60 | Running welding in repairs Thickness of metal to be welded n exc 6mm complete all as specified and as directed by Engr-in-Charge. |
| 61 | Running welding in repairs Thickness of metal to be welded Exc 6 mm butn exc 9mm complete all as specified and as directed by Engr-in-Charge. |
| 62 | S & F 50mm thick ceiling insulation of glass wool material Sheet consisting of intertwined and flexible glass fibers of width 1.2m with refractoriness temp 800-1400°C Density 16~48kg/m³ fixed at a hight upto 15 mtr with necessery scaffolding and safety arrangement complete all as specified and directed by Engr-in-Charge |
| 63 | S&F Raisco Nylon Green Uv-Stabilized Anti Bird/ Garden net 25 Mm Hole color-green material- nylon Ultraviolet protected nets complete all as specified and as directed by the Engineer-in-Charge |
| 64 | Providing and fixing factory made uPVG white colour Sliding window Three track area not exc 2.0 sqm made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 65 | M&L washed stone grit plaster on exterior walls in two layers under layer 12mm cement plaster 1:4 (1cement 4coarse sand) furrowingthe under layer with scratching tool applying cement slurry @ 3kg/sqm top layer 15mm cement plaster 1:1/2:2 ( 1white cement 1/2 coarse sand : 2 stone chipping coloured 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing & washing the top layer with brushes & water to expose the stone chipping and taking down old grit plaster complete all as specified pattern decided by Engr-in-Charge.(payment for providing grooves shall be made separately).Note:- Top layer of shade be of white cement using colouring pigment & stone chipping of desired colour as approved. |
| 66 | Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 67 | M&L for pre cast Kerb stone with plain fair faces 300x150x300 mm depth of PCC 1:1 ½ :3 of shape as approved incl all excavation, embedding in ground and removing surplus spoil upto 50 Mtr distance completed all as specified and as directed by Engr-in-Charge. |
| 68 | Taking out the existing paver blocks of any size and set and jointed again in the same position after cleaning of grass and other vegitation etc all as directed and specified by Engr-in-Charge. |
| 69 | S&F 2mm thick Linoleum covering, plain coloured, laid dry in floors including stretching, cutting and fitting complete all as specified and directed |
| 70 | Dismantling of mild steel work of any description not other wise provided of complete all as specified and as directed by Engr-in-Charge. |
| 71 | M&L for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410 W (Gde-E-250) quality-A complete all as specified and as directed by Engr-in-Charge. |
| 72 | S&F for MS as in posts, gate (ornamental type) and struts in fencing angle including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing with mesh etc including all necessary drilling bolting or riveting etc and similar work confirming to Fe-290 (Gde-E-165 quality-B. Note:-Posts/struts of angle iron made to shape shall be welded to existing angle iron bracket of security wall, contractor shall make his own arrangement for welding for boundary wall by using gen sets or any alternative arrangement all as specified and directed by Engr-in-Charge. |
| 73 | M&L for Steel work in tubular trusses, pillars and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and as directed by Engr-in-Charge. |
| 74 | M&L Cement concrete 75 mm thick type C-2, 1:3:6 (40mm graded aggregate) mass concrete as in sub base complete all as specified and as directed |
| 75 | M&L Chequered cement concrete tiles (vibrator made) 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over 15 mm thick screed bed in CM (1:4) finished with cloured cement to match the shed of the slab |
| 76 | M&L for 60 mm Machine pressed pre casted pressed cement concrete interlocking paver blocks with grey cement and no pigment of any shape and size conforming to IS- 15658-2006, strength not less than M-35 grouted with clean dry fine sand including 25mm thick sand cushioning all as directed by Engr-in-charge. |
| 77 | M&L for 100mm thick Cement concrete 1:2:4, type B-2 using 40 mm graded stone aggregate as in path finished even smooth with broom finished without using extra cement, laid in alternate panels with 8mm wide full depth joints duly filled with sealing compound Gde-A complete all as specified and directed by Engr-in-Charge. |
| 78 | M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in as in coping cill, rounded or chamffered on edges complete all as specified and directed by Engr in Charge. |
| 79 | Cleaning of open drains having inner girth width upto 0.60m and depth upto 1.2 mtr by removing mud, sludege silt, garbage, debries, sludge, vegitation etc and 1 mtr both side of drain also clear as vegitation and levelling the earth work and removing debrish by manually or machanically from out of MoD land complete all as specified and directed by Engr-in-Charge |
| 80 | Removing existing roof treatment and preparing surface to the entire satisfaction of Engineer-in-Charge/ GE including taking down existing plaster, cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc flushing at junction of parapets complete and removing the same to he places where directed by Engineer-in-Charge |
| 81 | M&L for 40mm thick cement concrete type B0, 1:2:4 (20 mm graded aggregate) as in floor/roof including waterproofing compound including finishing cement concrete using extra cement |
| 82 | M&L Providing cement concrete type B 1:2:4 (12.5mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 83 | M&L for rendering 15mm thick on fair faces of brick and concrete surface in CM 1:4 mixed with WPC finished even and smooth without using extra cement all as specified (WPC will be measured and paid separately) |
| 84 | M&L apply evenly a priming coat with bituminous primer at 4 kg per 10 sqm |
| 85 | M&L APP based polymeric membrane minimum weighing 3kg/sqm minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application with overlapping 150mm complete all as specified |
| 86 | M&L preparation of surface and applying two coat of aluminium paint on APP membrane, over 10 cm in width or girth not otherwise described complete all as specified and as directed |
| 87 | Supply only Liquid water proofing compound of approved quality |
| 88 | Note :- The amount of Rs 102880.00 against Schedule of Credit on Srl Page 146 shall be deducted from the total amount quoted against Sch 'A' Please Enable Macros to View BoQ information |