| 1 | Dismantling for wall and ceiling board (fiber, pulp insulation) or insulation boards/ slabs/ blankets any description and thickness in any position incl cover fillets complete all as specified and directed. |
| 2 | M&L for factory made second class soft wood wooden battens kiln dried spruce or pine profiled lumber, not less than 12mm thick, length 3000 mm & width 110-120 mm insert each other with male and female grooves fixed with nails to timber frame work as in wall/ceiling panelling, shelves etc including dismantling old wall/ceiling board any type and applying under coating and finishing coats of wood polishing complete all as specified and directed (Make-Beliy Ruchey or its equivalent as directed by Engr-in-Charge) |
| 3 | Dismantling timber scantling under 40 Sqcm on flats, rails, posts, rafter, purlins etc.in unframed work complete all as specified and directed. |
| 4 | M&L for second class soft wood, plain fillets, square or rectangular in section of area exc 13 and n exc 25 Sqcm, clean sawn, secured with nails or brands complete all as specified and directed. |
| 5 | M&L for first class softwood moulding as in cornices, rails etc Sectional area not exc 6 sqcm complete all as specified & directed |
| 6 | M&L second class soft wood, plain fillets, square or rectangular in section of area exc 3 and n exc 6 Sqcm, clean sawn, secured with nails or brands as in lipping complete all as specified and directed. |
| 7 | Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc. |
| 8 | Material and labour for point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5 sqmm incl 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earth wire ( green in clour) and connected to common earthing with PVC heavy duty casing caping/PVC conduit ISI marked conceiled in wooden panelling as rquired at site along with MS/SS modular sunken boxes of size as required at site along with modular cover frame amd cover plate for fixing swiches , sockets regulators incl accessories and making good the disturbed surfaces of wall/ ceiling etc for the following : - |
| 9 | One light point/ one fan point/ Bell Point controlled by one way switch |
| 10 | One 3 pin switch socket outlet, 5 Amp independent |
| 11 | One 3 in socket socket outlet 5 Amps on same board |
| 12 | Supply and fix modular switch piano flush type 6 Amps one module complete all as specified and directed |
| 13 | Supply and fix modular bell push 6 Amps one module complete all as specified and directed |
| 14 | Supply and fix modular socket 6 Amp 2/3 pin 02 module complete all as specified & directed |
| 15 | S & fix Ceiling rose 3 terminal flush type 6 Amps,250 volts AC ISI marked |
| 16 | S&F modular batten holder 230 volt complete all as specified and directed . |
| 17 | M&L for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy duty ISI marked /heavy duty conduit ISI marked as required at site alongwith with modular cover plate and cover frame of suitable size as required at site incl all accessories accessories with 2.5 Sq mm FRLS PVC insulated unsheathed copper conductor cable as earth wire ( green in colour ) and connected to common earth all as specified. |
| 18 | S & F in repair Modular socket 6/16 Amps 02 module complete all as specified and directed. |
| 19 | S & F in repair Modular switch 15/16 Amps 01 module complete all as specified and directed. |
| 20 | Supply & fixing surface /wall mounted light fitting pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 20 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. |
| 21 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed |
| 22 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 23 | Supply and Fixing LED bulb of 15 watt complete all as specified and directed. |
| 24 | M&L for calling bell AC 230 volt , 50 Hz complete all as specified and directed. |
| 25 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed. |
| 26 | Taking down old u/s submain wiring of any sizes with conduits/PVC casing and caping complete all as specified & directed. |
| 27 | M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 4 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 4 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed.Note :1. Two run of main copper conductor 4 sqmm size , one run of 4 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length .2. Proper colour coding shall be maintained as per IS code. |
| 28 | S&F in replacing distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface incl making good of surface complete all as specified and directed |
| 29 | Supply and fix in repairs of SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 30 | Supply and fix in repairs 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, with connection testing and commissioning complete all as specified and directed. |
| 31 | S&F in replace warm white/ white LED luminaire 600X600 mm,35/36 watt,220V recessed type lumen output >= 122 lumen per watts , THD < 10% environmental friendly , new generation , aesthetically designed , ultra modern with high brightness SMD LEDs as light source incl inbuilt drivers with high efficiency PMMA diffuser soft glare free light warm white complete suitable for roof ceiling including connecting up with three core flexible copper conductor of suitable size all as specified and directed. |
| 32 | S&F in repairs 1100 volts grade heavy duty cable PVC insulated aluminium conductor ,served with inner sheathing of PVC tape and overall PVC sheathed in service connections two core of size 16 sq mm flat or circular complete all as specified and directed |
| 33 | M&L for earthing complete with galvanized steel earth plate electrode60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0 mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified and directed. |
| 34 | Deduct Credit for Demolished/Dismantled material Rs (-) 5,130.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule)Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'. Please Enable Macros to View BoQ information |