| 1 | M&L one coats of cement base paint, white or tinted on old wall surface including preparation of surface including necessary scaffolding, trestles, ladders, cradles etc upto 12m height for necessary for execution of work and protective measures, removing of nails, making good holes, cracks etc, work in patches etc, spreading and removing coveings to doors, windows, floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. Complete all as specified and directed. |
| 2 | M&L two coats of cement base paint, white or tinted on old wall surface including preparation of surface including necessary scaffolding, trestles, ladders, cradles etc upto 12m height for necessary for execution of work and protective measures, removing of nails, making good holes, cracks etc, work in patches etc, spreading and removing coveings to doors, windows, floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. Complete all as specified and directed. |
| 3 | M&L one coats of acrylic Distemper, white or tinted on old wall surface including necessary scaffolding, trestles, ladders, cradles etc for necessary execution of work and protective measures and removing of nails, making good holes, cracks etc, work in patches etc spreading and removing to doors, windows floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. Complete all as specified and directed. |
| 4 | M&L two coats of acrylic Distemper, white or tinted on old wall surface including over a coat of 1mm thick wall care putty and including necessary scaffolding, trestles, ladders, cradles etc for necessary execution of work and protective measures and removing of nails, making good holes, cracks etc, work in patches etc spreading and removing to doors, windows floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy Complete all as specified and directed. |
| 5 | M & L for preparation of old plastered or unplastered surfaces of walls including cornices, pillasters, etc and applying one coat of white wash on wall including necessary scaffolding, trestles, ladders, cradles etc upto 12m height for necessary for execution of work and protective measures, removing of nails, making good holes, cracks etc, work in patches etc, spreading and removing coveings to doors, windows, floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. Complete all as specified and directed. |
| 6 | M & L for preparation of old plastered or unplastered surfaces of ceilings including cornices, etc and applying one coat of white wash including necessary scaffolding, trestles, ladders, cradles etc for necessary execution of work and protective measures, removing of nails, making good holes, cracks etc, work in patches etc, spreading and removing coveings to doors, windows, floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. Complete all as specified and directed. |
| 7 | M & L for preparation of old painted wooden surfaces of any description, not otherwise described, exceeding 10cm in width or girth and applying one finishing coat of synthetic enamel paint on wooden surfaces including removing of nails, making good holes, cracks etc, work in patches. etc spreading and removing to doors, windows floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. complete all as specified and directed. |
| 8 | M & L for preparation of old painted steel and iron surfaces of any description exceeding 10 cm in width or girth and applying one finishing coat of synthetic enamel paint on steel surfaces including removing of nails, making good holes, cracks etc, work in patches etc spreading and removing to doors, windows floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. complete all as specified and directed. |
| 9 | M & L for rendering 10 mm thick in CM 1:6 on brick Work or concrete surface incl taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and as directed |
| 10 | M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as on ceiling incl taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and as directed |
| 11 | M & L for rendering 15 mm thick in CM 1:4 on other than fair faces of brick Work or concrete surface incl taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and as directed |
| 12 | M&L two coats of Distemper oil emulsion, white or tinted on new wall surface including over a coat of 1mm thick wall care putty and including necessary scaffolding, trestles, ladders, cradles etc upto 10m height for necessary for execution of work and protective measures, work in patches etc spreading and removing to doors, windows floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy Complete all as specified and directed. |
| 13 | M & L for preparation of new plastered or unplastered surfaces of ceilings including cornices, etc and applying three finishing coat of white wash necessary scaffolding, trestles, ladders, cradles etc upto 10m height for necessary for execution of work and protective measures and removing of nails, making good holes, cracks etc, work in patches etc spreading and removing to doors, windows floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. Complete all as specified and directed. |
| 14 | M&L two coats of cement base paint, white or tinted on new wall surface including preparation of surface including necessary scaffolding, trestles, ladders, cradles etc upto 12m height for necessary for execution of work and protective measures, removing of nails, making good holes, cracks etc, work in patches etc, spreading and removing coveings to doors, windows, floors, fitings etc to protect them from splashes, washing floors cleaning glass, joinery, electric fittings, wiring etc of drops and splashes and leaving premises, clean and tidy. Complete all as specified and directed. |
| 15 | S&F Sheet glass 3.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq.m in each pane including hacking out old broken glass (any thicknesss, size,quality or description) from metal frame inlcuding punching or drilling out old glazing pins/spring clips & providing & fixing new ones including necessary scaffolding, trestles, ladders, cradles etc upto 12m height for necessary for execution of work and protective measures Complete all as specified and directed. |
| 16 | S&F Figured glass 3.0mm thick, pin head type & glazing with oil putty in squares n exc 0.5 sq.m in each pane including hacking out old broken glass (any thicknesss, size,quality or description) from metal frame inlcuding punching or drilling out old glazing pins/spring clips & providing & fixing new ones including necessary scaffolding, trestles, ladders, cradles etc upto 12m height for necessary for execution of work and protective measures Complete all as specified and directed. |
| 17 | S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples. |
| 18 | Taking down shutters of any description exc 1 sqm and nexc 2 sqm each. |
| 19 | S&F 35mm thick flush shutter, solid core construction, with block board core and plywood face panels, commerical type on both side Complete all as specified and directed. |
| 20 | M & L 35 mm thick glazed and skeleton shutters made of 2nd class hard wood, open rebated and prepared to receive glass gauge edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc for window, ventilator shutters, etc. as specified in SSR Part I, Section 8 clause 8.24(b) and fitted to chowkhat complete all as specified and directed . |
| 21 | S&F 150mm Aluminium anodised, barrel tower bolts of extruded section and fixed Complete all as specified and directed. |
| 22 | S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed Complete all as specified and directed. |
| 23 | S&F 150mm Extruded aluminium alloy handles, fabricated type, anodised. |
| 24 | S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor Complete all as specified and directed. |
| 25 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 26 | Applying two coats of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of pink primer Complete all as specified and directed. |
| 27 | Taking down Chowkats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) |
| 28 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing Complete all as specified and directed. |
| 29 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 30 | S&F 100mm butt hinges, aluminium extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 Complete all as specified and directed. |
| 31 | S&F Coloured Glazed ceramic tiles in vertical surfaces 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM (1:3) on fair face of brick or concrete surface incl dismantling of tiles and taking out backing coat Complete all as specified and directed. |
| 32 | S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM(1:4) incl dismantling of tiles and taking out backing coat Complete all as specified and directed. Please Enable Macros to View BoQ information |