| 1 | Providing Led fittings and Air conditioners in various places of Periodontics Department |
| 2 | OD343367/2025-2026:Supply, Conveyance, installation, testing and commissioning of 3000 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) (MR2612). and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. Colour of light as specified at site. |
| 3 | OD345303/2025-2026:Supply, conveyance, installation, testing and commissioning of 1800 lumen round/ square surface mount fitting made of diecast aluminum, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea. and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. Colour of light as specified at site. |
| 4 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 5 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 6 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 7 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 8 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 9 | OD345300/2025-2026:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming io IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc 2 Tr 5 star single phase Inverter type split AC unit with comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. |
| 10 | OD343370/2025-2026:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value(>5) rated inverter type 1.5 TR 5 star Hi-wall split air conditioner unit complying to IS: 1391: 1992 (Part-I & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerant gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumidifying. c. Air Circulating. d. Filtering including providing wireless remote control unit, 3 meter copper refrigerant piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . |
| 11 | OD345301/2025-2026:Supply and providing 5KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and output range of 210-240V |
| 12 | OD343381/2025-2026:Supply and Fixing of 4 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V |
| 13 | 90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm |
| 14 | OD343379/2025-2026:Supply and providing of 22gauge soft drawn copper pipe 1/2"/ equivalent size as suction pipe including insulation suitable rubber seal from sleev and giving connection etc. as required. |
| 15 | OD343380/2025-2026:Supply and providing of 22gauge soft drawn copper pipe 1/4"/ equivalent size as discharge pipe including insulation suitable rubber seal from sleev and giving connection etc. as required. |
| 16 | OD343378/2025-2026:Supply and installation of Drain Pipe 25mm |
| 17 | OD345443/2025-2026:Charges for dismantling the existing EI, complete, making good the damages of walls and conveying the dismantled materials to section store |
| 18 | OD345444/2025-2026:Supply and fabrication conveyance and installation of angle iron frame work Please Enable Macros to View BoQ information |