| 1 | Taking down existing tarfelt including tiles, lime concrete & screed bed complete from roof surfaces including parapets and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed. |
| 2 | M&L for 15mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, and water proofing compound @ 3% finished even and smooth without using extra cement complete all as specified and as directed. (NOTE : Polymeric membrane shall be measured and paid separately under relevant item of this Schedule 'A'). complete all as specified and as directed. |
| 3 | M & L for cleaning the newly plastered surfaces of concrete with wire brushes and applying water proofing treatment as under :- (i) Apply one coat of bituminous primer @ 0.10 kg/Sq.M (ii) Providing and laying by torch application method APP polymeric modified bituminous water proofing membrane with non woven polyester mat as reinforcement membrane minimum 3mm thick with bituminous plain finish on upper side weighing not less than 3.0Kg/Sqm procured from any of the approved manufactures |
| 4 | S & F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors ladders; framed balusters, walk ways, railings, framework of water tanks and similar workconforming to Fe.290.Gde-E-165 |
| 5 | S&F for Hard drawn steel wire fabric cut to lengths, bent to shape required andtying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement |
| 6 | M&L for Demolition of (unreinforced) cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 7 | M&L for cement concrete 25mm thick type B1 1:2:4 at top surface using 20mm graded aggregates, complete all as specified and directed |
| 8 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6, complete all as specified and as directed. |
| 9 | M&L for Glazed colour ceramic tiles as in vertical surface (350x 250x 7 mm/ 450X 350X 7mm thick) set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering cement mortar 10mm thick for fixing tile in dado/skirting in CM 1:3, complete all as specified and as directed. |
| 10 | Material and Labour for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed or bedding layer of mortar 10mm thick for laying floor finishes in cement mortar 1:6, complete all as specified and as directed. |
| 11 | Demolition of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 12 | Cutting through brick wall for holes and making good disturb portion in CM (1:3).Exc half brick thick wall but not exc one brick thick wall. |
| 13 | M&L for PVC floor trap plain with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).75mm dia |
| 14 | M&L for PVC Nahani trap plain with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).75mm dia |
| 15 | S&F in repair 10 litre capacity PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length , brackets complete all as specified and as directed |
| 16 | Supply and fixing Vitreous China, semi-pedestal pattern (Anglo-Indian Type) white including pedestal pan and trap, connection to drain (or out going pipe) and to flushing pipe, antisiphonage pipe, etc (excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 17 | Dismantling of cast iron (Internal dia of pipe in 100 mm ) or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and as directed. |
| 18 | S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall. |
| 19 | S&F 110mm dia PVC SWR bends of any radius with access door complete all as specified and as directed |
| 20 | S&F 110mm dia PVC (SWR) junction single 'T' equal or unequal with access door Complete all as specified and as directed. |
| 21 | S&F 110mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal with access door Complete all as specified and as directed. |
| 22 | M& L for cement concrete 75mm thick type C-2, 1:3:6 (using 40mm graded stone aggregate) in plinth protection including necessary formwork complete all as specified and as directed. |
| 23 | Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key scrubbing down water etc and removing materials from site of work complete all as directed. |
| 24 | M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) mixed with water proofing compound in top layer @2% by the weight of cement or as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed.Note : Integral water proofing compund shall be measured and paid separtely. |
| 25 | Supply only integral water proofing compound complete all as specified and as directed. |
| 26 | M & L for 15 mm thick rendering in CM (1:6) finished even and smooth without using extra cement to wall complete all as directed. |
| 27 | M&L for 5mm thick plaster rendering on fair faces of concrete surfaces as in ceiling in CM(1:3) finished even and smooth (without using extra cement) complete all as specified and as directed. |
| 28 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. ( Note :- Shade shall be approved by Engr-in-Charge) |
| 29 | M&L for preparing of new surfaces of walls and applying two coats of oil emulsion distemper on the same after Chalk whiting, on plastered surfaces, prepara-tory to distempering on internal wall surfaces, all complete as specified and directed. |
| 30 | M & L for three coats of white wash on newly plastered surface of ceiling including necessary surface preparation, complete all as specified and directed |
| 31 | M&L for preparation of old decorated plastered surfaces of internal wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of oil emulsion distermper complete all as specified and directed. |
| 32 | M&L for preparation of old decorated plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of white wash complete in ceiling all as specified and directed. |
| 33 | M&L for Formwork in repairs to flat surface of fascia complete all as specified and directed. |
| 34 | M&L for Reinforced cement concrete (nominal mix) with Type B1 1:2:4 (20 mm graded aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like, complete all as specified and directed. |
| 35 | Materials and labour for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint (first quality), complete all as specified and as directed. |
| 36 | All as per item No. 35.00 here-in-before, but on steel surfaces. |
| 37 | Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials from site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed |
| 38 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall including all cutting chasing and making good with matching specification, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth duly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick hylam laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed by Engr-in-Charge at site for the following : (a) One light/ Fan /Exhaust point controlled by one way switch. |
| 39 | All as per item No 38 here-in-before but for one light point controled by one two way switch on the same board with other switches or independent all as specified and directed. |
| 40 | All as per item No 38 here-in-before but for one bell point controled by one bell push on the same board with other switches or independent all as specified and directed. |
| 41 | All as per item No 38 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed. |
| 42 | All as per Item No 38 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed. |
| 43 | All as per item No 38 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed |
| 44 | M&L for sub main wiring with 2 run of single core 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of required size alongwith accessories on roof/walls/ ceiling etc including one run of 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 6.0 Sqmm single core cable, one run of 6.0 Sqmm earth wire and one run of PVC conduit/ casing capping shall be measured as one run length |
| 45 | Supply and fix modular Switch single pole, one way 5 Amp complete all as specified and directed. |
| 46 | Supply and fix modular Switch single pole, two way 5 Amp complete all as specified and directed. |
| 47 | Supply and fix bell push, modular type, 6 Amps, complete all as specified and directed. |
| 48 | Supply and fix modular Switch single pole, one way 15 Amp complete all as specified and directed. |
| 49 | Supply and fix modular Socket 5 Amps, 230 volts, complete all as specified and as directed. |
| 50 | Supply and fix modular socket, 16 amps complete all as specified and directed. |
| 51 | Supply and fix modular fan regulator 2 module complete all as specified and directed. |
| 52 | S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. |
| 53 | Fixing only ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. (Serviceable ceiling rose obtained shall be reused) |
| 54 | S&F modular white cover plate with frame of 1 Module complete all as specified and directed. |
| 55 | S&F modular white cover plate with frame of 3 module complete all as specified and directed. |
| 56 | S&F modular white cover plate with frame of 6 module complete all as specified and directed. |
| 57 | S&F modular white cover plate with frame of 8 module complete all as specified and directed. |
| 58 | S&F Metal flush box of 1 module complete all as specified and directed. |
| 59 | S&F Metal flush box of 3 module complete all as specified and as directed. |
| 60 | S&F Metal flush box of 6 / 8 module complete all as specified and as directed. |
| 61 | Supply and fixing LED lights fitting 4 feet 20 watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 62 | Fixing only LED lights fitting 4 feet 20 watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. (Serviceable LED lights obtained shall be reused) |
| 63 | Supply and fixing LED lights fitting 2 feet 10 watt 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 64 | Fixing only LED lights fitting 2 feet 10 watt 220 V, AC decorative box type / Bulk head type LED fitting including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. (Serviceable LED lights obtained shall be reused) |
| 65 | Supply and fixing of Bulk head fitting poly carbonate main body with Opal diffuser suitable with 10 W LED complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 66 | Supply and fixing of Bulk head fitting poly carbonate main body with Opal diffuser suitable with 10 W LED complete all as specified and as directed. Please Enable Macros to View BoQ information |