| 1 | Relay effectiveness testing by Secondey injection set of Earth Lekage with test Certificate of 6.6 kv Indoor Panels |
| 2 | Relay effectiveness testing by primary injection set of CTs/Over current with test Certificate of 6.6 KV Indoor Panels |
| 3 | Relay effectiveness testing by Secondey injection set of Earth Fault with test Certificate of 6.6 KV Indoor Panels |
| 4 | Testing of Earth pit with test certificate |
| 5 | Testing of Insulason test with test certificate of 6.6 KV Indoor Panels |
| 6 | High Prasor(HV) set Braker with test Certificate of 6.6 KV Indoor Panels |
| 7 | Testing of Dielectric Strength Test of Insulating Oil ,Acidity Test of Insulating oil and Flash point of Insulating oil with test Certificate of 6.6 kv Indoor Panels |
| 8 | Testing of Dielectric Strength Test of Insulating Oil ,Acidity Test of Insulating oil and Flash point of Insulating oil with test Certificate of 20 MVA 100 kva ,40 kva Transformer |
| 9 | High Prasor(HV) set Braker and Alarm & Trip device test with test Certificate of 20 MVA 100 kva 40 kva Transformer |
| 10 | Testing of Insulation Resistance Test and High Prasor(HV) set with test certificate of 90 sq mm PVC Double Armoured Aluminium cable. |
| 11 | Testing of Overhead line Insulason test with test certificate6.6 KV 3 PHASE OVERHEAD LINE FROM 33 kv sub station sudamdih TO Main Coloney Sub station aprox 4.5 Km Panal No 09 |
| 12 | Testing of Overhead line High Prasor(HV) set with test certificate 6.6 KV 3 PHASE OVERHEAD LINE FROM 33 kv sub station sudamdih TO Main Coloney Sub station aprox 4.5 Km Panal No 09 |
| 13 | Testing of Overhead line Insulason test with test certificate 6.6 KV 3 PHASE OVERHEAD LINE FROM 33 kv sub station sudamdih TO River site Sub station aprox 2.5 Km Panal No 04 |
| 14 | Testing of Overhead line High Prasor(HV) set with test certificate 6.6 KV 3 PHASE OVERHEAD LINE FROM 33 kv sub station sudamdih TO River Site Sub station aprox 3.5 Km Panal No 04 |
| 15 | Testing of Overhead line Insulason test with test certificate6.6 KV 3 PHASE OVERHEAD LINE FROM 33 kv sub station sudamdih TO River site Sub station aprox 3 Km Panal No 27 |
| 16 | Testing of Overhead line High Prasor(HV) set with test certificate6.6 KV 3 PHASE OVERHEAD LINE FROM 33 kv sub station sudamdih TO River Site Sub station aprox 3 Km Panal No 27 |
| 17 | Relay effectiveness testing by primary injection set of CTs/Over current with test Certificate of 33 KV Indoor Panels |
| 18 | Relay effectiveness testing by Secondey injection set of Earth Fault with test Certificate of 33 KV Indoor Panels |
| 19 | Testing of Insulason test with test certificate of 33 KV Indoor Panels |
| 20 | High Prasor(HV) set Braker with test Certificate of 33 KV Indoor Panels |
| 21 | Testing of Dielectric Strength Test of Insulating Oil ,Acidity Test of Insulating oil and Flash point of Insulating oil with test Certificate of 33 kv Indoor Panels |
| 22 | DGA testing of 20 MVA, 33 KV/6.6 KV with test certificate |
| 23 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |