| 1 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: .1 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 meters lead : 15.39.1 Upto 10 mm thick |
| 4 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. 15.23.1 For thickness of tiles 10 mm to 25 mm |
| 6 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding holdfasts in cement concrete blocks of size 15x10x10cm with cement concrete 1:3:6 (1 cement :3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meters lead: Door chowkhats |
| 7 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding holdfasts in cement concrete blocks of size 15x10x10cm with cement concrete 1:3:6 (1 cement :3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meters lead: Windows |
| 8 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.21.1 With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 9 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Particle Board 12mm thick Pre-laminated particle board with decorative lamination on both sides,Grade I Type II IS : 12823 marked |
| 10 | Providing and fixing shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood |
| 11 | Applying primer coat with ready mixe pink or grey primer of approved brand and manufacture on wood work. |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 13 | Providing and fixing wpc charcoal panelling louves in walls including carriage complete Job complete job (NSI) |
| 14 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 15 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 16 | Finishing walls with Acrylic smooth exterior paint of required shade: Old work (two or more coats applied @ 1.67 liters/10sqm on existing cement paint surface) |
| 17 | Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade |
| 18 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 19 | Polishing on wood work with readymade wax polish of approved brand and manufacture on old work. |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications old work |
| 21 | 12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand) |
| 22 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 23 | Renewing glass panes, with putty and nails wherever necessary includingraking out old putty :14.6.1 Float glass panes of thickness 4.0 mm(weight not less than10kg/sqm) |
| 24 | Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc. This includes testing of joints complete as per direction of the Engineer-in-charge: 2532 (32mm OD) |
| 25 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 18.2.1 W.C. pan with ISI marked white solid plastic seat and lid. |
| 26 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. |
| 27 | Providing and fixing waste for sink or wash basin including P .V .C. waste fittings complete. Flaxible Pipe 40 mm |
| 28 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm |
| 29 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 30 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge. |
| 31 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 32 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 33 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 34 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 35 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 36 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 37 | Providing and fixing surface mounted 18/20 watt LED Tube fitting 4 feet long (NSI) |
| 38 | Providing and fixing12watt LED Bulb (NSI) |
| 39 | Supplying and drwaing 2x2.5sqmmm FRLS pvc insulated copper single core cable (NSI) |
| 40 | Supplying and Fixing of single phase self priming water including connectors 1HP (NSI) |
| 41 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete : |
| 42 | Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm |
| 43 | Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete :.1 300x10 mm |
| 44 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 45 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 46 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. 11.50.1 In colour such as White, Ivory, Grey, Fume Red Brown |
| 47 | Providing and fixing UV stabilized fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts and nuts 8mm dia. G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-violet stabilizer in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS: 10192 and IS: 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 12.22.1 2mm thick corrugated (2.5\\" or 4.2\\" or 6\\") or step-down (2\\" or 3\\" or 6\\") as specified. |
| 48 | Chequerred terrazzo tiles 22mm thick with graded marble chips of size upto 6mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, polishing and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Ordinary cement without any pigment. |
| 49 | Regrading terracing of mud phaska covered with tiles or bricks, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement: 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 meters lead. |
| 50 | Providing and fixing of Cupboard along with pannels ( Readymade Almirah ) of approved quality Complete job (NSI) |
| 51 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 52 | Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigmentsetc. complete Size of tile 600x600 mm |
| 53 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) 22.3.1 With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) |
| 54 | Providing and fixing wooden flooring 8mm thick. Complete job NSI |
| 55 | Providing and fixing Wiring of light for fan point. (NSI) |
| 56 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel platedbrackets1 20 mm dia ( heavy type) |
| 57 | Providing and fixing 250 GSM curtain (NSI) |
| 58 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches forfoundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts,wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres:.1 All kinds of soil : |
| 59 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 60 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 61 | Carriage of material by mechanical transport from source to the site of work including loading/unloading and stakcing complete. |
| 62 | Sand for an av. 80 Kms disntace. |
| 63 | Bajree for an av. 20 Kms disntace. Please Enable Macros to View BoQ information |