| 1 | Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc.Complete all as specified and as directed. |
| 2 | M&L for rendering 05 mm thick cement plaster with cement mortar(1:4) on fair faces mixed with water proofing compound as per manufactures instruction over and including 10 mm thick backing coat in cement mortar (1:4) of brick work or concrete surfaces and finished even and smooth without using extra cement (Note : water proofing treatment (Water proofing will be measured and paid separately).Complete all as specified and as directed. |
| 3 | M&L for rendering 15 mm thick cement plaster with cement mortar(1:6)on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement.Complete all as specified and as directed. |
| 4 | M&L for rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement.Complete all as specified and as directed. |
| 5 | Supply only liquid water proofing compound .Complete all as specified and as directed. |
| 6 | M&L Perparatrion of newly plastered surfaces of walls and applying two coat of acrlic emulsion distemper over one coat of primer all as speicfied and directed. .Complete all as specified and as directed. |
| 7 | M&L Perparatrion of old plastered surfaces of walls and applying one coat of acrylic emulsion distemper.Complete all as specified and as directed. |
| 8 | M&L for preparation of new surfaces of wall and apply two coat of cement base paint including one coat of cement primer. Complete all as specified and as directed. |
| 9 | M&L for preparation complete removal of exising treatment of old surfaces and apply two coat of cement base paint to walls surface including one coat of cement base primer.Complete all as specified and as directed. |
| 10 | M&L for applyoing 3mm thick wall care putty on wall all as specified and directed |
| 11 | M&L for applyoing 3mm thick wall care putty on ceiling all as specified and directed |
| 12 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demoltion complete all as specified. |
| 13 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store andd rubbish off the premises.Complete all as specified and as directed. |
| 14 | M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4.Complete all as specified and directed. |
| 15 | M&L for glazed ceramic tiles vertical surfaces 600/300/450x300x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the surface including rendering 10mm thick cement plaster on fair face of brick work in cement mortar 1:3 as in backing coat for wall tile.Complete all as specified and directed. |
| 16 | Vitrified light shade Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface ncluding 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed. completer all as specified and directed |
| 17 | Vitrified light shade Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface as skirting complete all as specified and directed. completer all as specified and directed |
| 18 | M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and smooth with using extra cement complete all as specified. |
| 19 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each.Complete all as specified and directed. |
| 20 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) nexc 1.50 sqm complete all as specified and directed. |
| 21 | Taking down of shutter of any description exc 1 sqm and n exc 2 sqm all as specified and directed |
| 22 | M&L for refixing of shutter on same opening of any description exc 1 sqm and n exc 2 sqm all as specified and directed |
| 23 | S&F Anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge |
| 24 | S&F Anodised aluminium powder coated (minimum thickness of powder coating 50 micron) door shutters,aluminium section weighing 0.55 kg/ m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. Complete all as specified and directed. |
| 25 | S&F Anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engineer-in-Charge |
| 26 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors,windows, ventilators and Partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gaske etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charg |
| 27 | S&F Floor door stopper 140 mm overall length of cover plate of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in bottom body of door complete all as specified and directed |
| 28 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed.Complete all as specified and directed. |
| 29 | S&F Aluminium (extruded section) body Door closer hydraulically regulated,designation No. 1 universal type,suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed all as specified and directed |
| 30 | S&F Aluminium Mortice lock, of 4 levers vertical type, size 100 mm.Complete all as specified and directed. |
| 31 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified |
| 32 | S&F 3 mm Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane .Complete all as specified and directed. |
| 33 | S&F in repairs Galvanised steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed.Complete all as specified and directed. |
| 34 | S&F Sheet glass 5.5 mm thick for aluminium doors/windows, partitions automatic doors and similar work including cutting to shape, drilling holes required Securing glass in metal frames.Complete all as specified and directed. |
| 35 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.Complete all as specified and directed. |
| 36 | Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.Complete all as specified and directed. |
| 37 | S&F in repairs curtain rail ,20 mm dia anodised aluminium alloy ,cromium plated fixed with braket.Complete all as specified and directed. |
| 38 | S&F 75 mm butt hinges, meium weight cold rolled mild steel. |
| 39 | S&F Aluminium handles cast type anodised of size 150mm long ISI marked |
| 40 | S&F Aluminium anodised barrel tower bolt 200 mm, extruded section. |
| 41 | S&F aluminium anodised sliding door bolts round nuckle with hasp and stapple extruded section or cast aluminium alloy 300 mm long complete all as specified. |
| 42 | S&F figured glass sheet, 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane. |
| 43 | M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide premier.Complete all as specified and directed. |
| 44 | M&L for preparation of old steel and iron surfaces exceeding 10 cms width or girth and applying one coat of synthetic enamel paint.Complete all as specified and directed. |
| 45 | Providing cement concrete type C-1, 1:3:6 ( using 20mm graded stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight).Complete all as specified and directed. |
| 46 | S&F Rotational moulded polyethylene water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc all as specified and directed |
| 47 | S&Fin repair ball valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball 20mm dia bore. |
| 48 | S&F ball valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball 20mm dia bore. |
| 49 | S&F stop valves cast copper alloy serwed down high pressure , 15 dia bore fixed |
| 50 | S&F stop valves cast copper alloy serwed down high pressure with crutch or butterfly handle 20mm dia bore fixed |
| 51 | Cast iron floor trap dia meter of out let 100 mm, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed |
| 52 | S&F Vitreous china wash down water closet pan (Pedestal pattern), white (excluding finxing bolts, flushing cistern and flush pipe) .(excluding flushing cistern & flush pipe) complete in all respect all as specified and as directed by Engr-in-Charge |
| 53 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 54 | S&F Vitreous China urinals, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified and directed by Engr-in-Charge |
| 55 | Vitreous china, wash hand basin (WHB) flat back size 580x450mm including tap, waste fittings brass, chromium plated for glazed ware, basin etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, including pillar tap& brackets, 32 mm waste couplig & pipe all as spd & directed. |
| 56 | S&F Toilet paper holder, vitreous china, box type fixed to wall with chromium plated (CP) brass screws.Complete all as specified and directed. |
| 57 | S&F PVC 10 ltr valveless, syphonic action type, flushing cistern, low level white with inlet ball valve, float and handle including brackets.Complete all as specified and directed. |
| 58 | S&F PVC connection 15 mm size with PTMT nuts 450 mm long. |
| 59 | S&F Aluminium anodised towel rail 20mm dia 'D' type 60 cm long between flanges . |
| 60 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms all as specified and directed |
| 61 | S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) all as specified and directed |
| 62 | S&F Mild steel galvanized steel tubing 20 mm dia bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors.Complete all as specified and directed. |
| 63 | S&F Mild steel galvanized steel tubing15 mm dia bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors Complete all as specified and directed. |
| 64 | S&F 15 mm bore CP stop valves fancy type with long shank and cup (Concealed type) , cast copper alloy with crutch or butter fly handle, high pressure, screwed down, screwed both ends for iron pipe or for brass ferrule all as specified |
| 65 | S&F 15mm bore Bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified. |
| 66 | S&F PVC cowls 100mm fixed in repairs all as specified directed. |
| 67 | M&L for PVC (SWR) gully trap 125x110 mm setiing in jointing with solvent cement all as specified and directed |
| 68 | S&F cast iron nahani trap with grating including jointing to wast pipe fixed in cement concrete type B-1 (1:2:4) of 75 mm bore complete all as specified |
| 69 | S&F 600x450mm bevelled edge mirror selected quality glass mounted on 6mm thick AC bld of board and mounting with aluminium channel of size 10x10mm and fixed complete to wall fixed.Complete all as specified and directed. |
| 70 | S&F 110mm bore PVC SWR pipes single socket in any length with rubber joints fixed in wall etc all as specified and directed. |
| 71 | S&F in replairs PVC SWR bends any radius 110 mm bore all as specified. |
| 72 | Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 73 | S&F 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing all as specified and directed by Engr-in-Charge |
| 74 | M&L for anodised aluminium snap grid frame work for false ceiling with Hangers 6mm dia . GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40mm long and fixing 4mm non asbestos fibre cement building boards fixed or laid/or inserted to timber.Complete all as specified and directed. |
| 75 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engr-In-Charge. |
| 76 | All as per item 75 above here but plain sheets for ridge.. |
| 77 | Rolled mild steel section as in main and cross beams, hip and jack,rafters, purlins, where connected to common, rafters and running rails and guiders for sliding doors: fixed with angle cleats or other connecting platesconforming to grade Fe410-W (Gde E-250) all as specified |
| 78 | S&F mild steel joist channel angle or tee sections fixed independently without connected plates etc of grade fe-410-0 or fe-310-0.Complete all as specified and directed. |
| 79 | Demolition of brick work or stone masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, all as specified . |
| 80 | M&L Brickwork with fly ash bricks old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4.Complete all as specified and directed. |
| 81 | M&L 18/19 mm Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work.Complete all as specified and directed. |
| 82 | M&L 12 mm Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work.Complete all as specified and directed. |
| 83 | Excavation in trenches n exc 1.5 m wide and n exc 1.5 m deep and getting out in hard/dense soil for foundation etc, or for shafts, wells, cess pits, manholes, pier holes etc and for sewage lines n exc 10 Sqm on plan all as specified. |
| 84 | M&L for cement concrete (Type D2) 1:4:8 in foundations, filling and mass concrete complete all as specified and directed. |
| 85 | Dampproof course 50 micron thick polythene over coat of blown bitumen 85/25 grade @ 1.50 kg /per Sqm over 40mm thick PCC 1:2:3 type B0 with WPC in proportion to horizontal or vertical surfaces including necessary formwork as specified and directed |
| 86 | M&L for ATT, treating the top surface of filled earth at the rate of 5 ltrs of emulsion per square meter of surface area complete all as specified and directed |
| 87 | Brick work with fly ash brick, (old size bricks) straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6.all as spedf dierected. |
| 88 | M&L for PCC 1:2:4 tye C-1, 20 mm graded stone aggregate in bed blocks,cills, plinth course and coping complete all as specified and directed. |
| 89 | M&L for 75 mm thick cement concrete type B-2, 1:2:4 using 40 mm graded aggregated as in sub floor, all as spd & directed by Engr-in- Charge |
| 90 | M&L RCC Type M-25 ( Design mix, 20 mm graded aggregate) for plinth band Foundations, including rafts, footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete.Complete all as specified and directed. |
| 91 | M&L RCC Type M-25 (Design mix, 20 mm graded aggregate) aggregate) for columns, pillars, piers, post &struts all as spd and directed. |
| 92 | M&L RCC Type M-25 (Design mix, 20 mm graded aggregate) aggregate) for beams, cantilevers, bressummers, lintels over 1.50 m span all as spd and directed. |
| 93 | M&L RCC Type M-25 (Design mix, 20 mm graded aggregate) aggregate) for roof slab supported on walls,,beams and columns in floors, roofs , landing and similar work cement concrete all as spd and directed. |
| 94 | M&L reinforcement cement concrete (M-25 Design Mix) (20mm graded stone aggregatge) for Chajjas/Balcony/Landing work if any all as per specified. |
| 95 | M&L TMT bars 8 mm dia and over, cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.9mm dia.Complete all as specified and directed. |
| 96 | M&L TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.9mm dia.Complete all as specified and directed. |
| 97 | M&L TMT bars 6mm to 5 mm dia and over upto and including 10mm dia in stirrup, spaces and binders cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.9mm dia. |
| 98 | M&L For Formwork to Rough finished flat surfaces of finishedconcretesides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. |
| 99 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors andbeams, etc. |
| 100 | M&L Formwork rough finished flat to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping).Complete all as specified and directed. |
| 101 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but not exc10cm widero.Complete all as specified and directed. |
| 102 | M&L Formwork rough finished flat to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including sup- ports, overhangs, etc. complete all as specified. |
| 103 | Cutting into existing manholes for connecting new drains, making good to pipe (150 dia) and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required |
| 104 | M&L for PCC (1:3:6) type C2 (using 40 mm graded stone) aggregate as in concrete bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed |
| 105 | M&L for 150 mm bore (internal dia) reinforced concrete pipe, class NP-2 with collars laid in trenches and jointed on concrete bed to required slope jointed and plasted complete all as specified and as directed .(Concrete bed shall be measure and paid separately |
| 106 | Surface excavation in soft and loose soil n.exc 30 cm deep and averaging 15 cm and getting out all as specified and directed by Engineer-in-Charge |
| 107 | Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed |
| 108 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed. |
| 109 | M&L 50 mm Sand filling under floors or in foundation similar works complete all as specified and directed. |
| 110 | S&F Steel rolling shutters (thickness of laths 1.25 mm) , with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type all as Sepcified and directed by Engr-in-Charge |
| 111 | S&F Safety lever locks mild steel with 4 lever for rolling shutters complete all as specified and directed |
| 112 | M&L for concealed point wiring for One light/fan point controlled by one switch 5 Amps using 1.5 Sqmm PVC insulated sheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100 Volts grade, ISI marked, drawn in to PVC conduit pipe including all accessories as bend,tee,junction boxes elbows etc inc pressed steel terminal sunken boxes of size 1.2mm covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws and unsheathed copper conductor stranded cable(FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly including taking down od unserviceable point wiring if any found at site and nothing will be paid extra and and rate included in quated rate. |
| 113 | All as per Item No 112.00 above but One 3 pin socket outlet 5 Amps on Independent board |
| 114 | All as per Item No 112.00 above but One 3 pin socket outlet 5 Amps on same board |
| 115 | All as per Item No 112.00 above but One bell point controlled by one bell push |
| 116 | All as per item No 112.00 but with 2.5 sq mm PVC insulated copper conductor cable incl 2.5 sq mm PVC copper conductor used as earth wire for power point on independent board |
| 117 | S&F modular switch, one way, 6Amps, one module complete all as specified. |
| 118 | S&F modular switch, one way, 16Amps, one module complete all as specified. |
| 119 | S&F modular socket outlet, 6Amps, 2 and 3 pin combined two modules complete all as specified. |
| 120 | S&F modular socket outlet, 6Amps/ 16 Amps, 2 and 3 pin combined two modules complete all as specified. |
| 121 | S&F modular fan regulator step type, 120 Watt, two modules complete all as specified. |
| 122 | S&F modular Bell push, 6 Amps, one module complete all as specified. |
| 123 | M&L for Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 250 volts AC ISI marked,complete all as specified and directed. |
| 124 | S&F in repar Modular metal flush box 3 module |
| 125 | S&F in repair Modular metal flush box 4 module |
| 126 | S&F in repair Modular metal flush box 6/8 module |
| 127 | S&F in repair Modular white cover plate with frame 3 module |
| 128 | S&F in repair Modular white cover plate with frame 4 module |
| 129 | S&F in reapir Modular white cover plate with frame 6 module |
| 130 | S&F in repair Modular white cover plate with frame 8 module |
| 131 | M&L for new concealed Sub main wiring using two single core PVC insulated cable(FRLS) 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable (FRLS)using as earth wire and drawing into PVC conduit including taking down of old if any complete all as specified and directed. Note- One run of PVC conduit, 03 run of 6 sq mm PVC copper wire measured as one Unit complete all as specified and directed. |
| 132 | M&L for new Sub main wiring using two single core PVC insulated cable FRLS 4 sqmm copper conductor multi stranded and 4 sqmm copper conductor insulated cable (FRLS)using as earth wire and drawing into PVC Casing and Caping complete all as specified and directed .Note- One run of PVC casing caping , 03 run of 4 sq mm PVC copper wire measured as one Unit complete all as specified and directed. |
| 133 | S&F in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet steel),RAL 9003, Powder coated dust and vermin proof, VTPN 6 way with 200 Amps rated copper bus bar double metal door protection, neutral bar,earth bar, with provision of 4 pole MCCB 63/100 as incomer and SP/TP/TPN MCBs as outgoing complete all as spd and directed Make - L&T Cat No DBVTL006DD. |
| 134 | S&F 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. complete all as spd and directed |
| 135 | S&F in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 415 volts complete all as spd and directed . |
| 136 | S&F in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar single door protection, neutral bar,earth bar, single pole and neutral 250 volts complete all as spd and directed . |
| 137 | All as per ser item No 136 here-in-before but SPN 4 way 240 volts double door type . |
| 138 | M&L for MCB SPN 63 Amps 240 V C curve complete all as spd and directed . |
| 139 | S&F SPN 40 Amps 240V ,50 Hz ,breaking capacity 10 KA,\\" C \\" series. Including taking down unsvericeable. |
| 140 | All as per ser item No 139 here-in-before but MCB triple pole & neutral 415 volt C curve 10 KA 63 Amps capacity |
| 141 | M&L for MCB single pole 5 to 40 Amps 10KA 230 V complete all as specified and directed . |
| 142 | S&F in replacement of single pole and neutral enclouser with a two pin and earth plug and socket complete with one MCB single pole 20 Amps |
| 143 | M&L for Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed by the Engineer -in-charge . |
| 144 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr in Charge. |
| 145 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 146 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 147 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. |
| 148 | Supply & fix wall mounted fans AC single phase 230/ 240 V of size 400 mm sweep with louver complete all as specified and directed. |
| 149 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary of capacity 2TR ,5 star rating.complete all as specified and as directed. |
| 150 | Supply and fix Voltage stabilizer for automatic operation, copper wound, single phase naturally air cooled indoor type & designed for input variation between 150 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.complete all as specified and as directed. |
| 151 | Excavation in trenches in Soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying pipe lines not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level .complete all as specified and as directed. |
| 152 | Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.complete all as specified and as directed. |
| 153 | Returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil.complete all as specified and as directed. |
| 154 | Material and labour for sand cushioning for U/G cable 8 cm before laying the cable and 15cm after laying and stretching the cable.complete all as specified and as directed. |
| 155 | Material and labour for fly ash bricks well burnt old size designation 75 laid dry flat for protection of cable.complete all as specified and as directed. |
| 156 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete with excavation, sand cushioning, brick laying, removing and returning filling complete all as specified and as directed. Please Enable Macros to View BoQ information |